CAP 437 6th Edition CAP 437 7th Edition More demanding MD Applicability to new build Applicability to existing

ew build Applicability to existing installations


requirement / reference requirement / reference Less demanding LD installations / vessels / vessels – including refurbishments

“CAP 437 – Standards for Offshore Helicopter Landing Areas”

Chapter 3, Section 3 – 5
Helideck Structural Design
Chapter 3, Section 3 – 5 N/A All new build helidecks Existing installations will be
Helideck Structural Design Review of Sections 3-5 to completed on or after 15 periodically re-assessed against
ensure they reflect the November 2013 latest best practice in 7th edition.
structural design guidance
presented in ISO 19901-3
published in December
2010.

Chapter 4 Section 2. Chapter 4, Section 2, Applicable to all new builds All existing helidecks with a D-value
Paragraph 2.4. The whole Paragraph 2.4. The whole MD - to comply with with a certificated D-value of 15.00 m or greater should display
number D-value painted in number D-value painted in update of Annex 14 15.00m or more completed on whole number D-values around the
three locations around the three locations around the Volume II (now or after 15 November 2013. perimeter which are at least 90 cm
helideck should be a helideck should be a scheduled for November For D-values less than high. For D-values less than
minimum character height of minimum character height of 2013) 15.00m the D-value character 15.00m the D-value character
60 cm 90 cm for D-values height may remain at (not less height may remain at 60 cm.
>15.00m. than) 60 cm. Characters should be increased at
the next convenient opportunity but
by no later than 15 November 2013.

Chapter 4 Section 3, Para 4 Chapter 4 Section 3, Para 4 All new build helidecks are A letter to industry will be circulated
and new Appendix E. Formal and final specification for MD strongly encouraged to utilise around end of 2Q 2012
draft specification now TD/PM circle and ‘H’ lighting lighting systems consisting of encouraging existing installations
published for TD/PM circle systems presented in Safety green perimeter lights, yellow on the UKCS to provide, within a 5-
and ‘H’ lighting systems. Now Appendix C (effectively Recommendation circle and green “H” that are year period, improved lighting
presented as an alternative replacing draft Appendix E). 2011-053 from AAIB fully compliant with the schemes consisting of green
to traditional deck mounted Recommendation to replace report 1/2011 into the G- detailed and final specification perimeter lights, yellow circle and
floodlighting systems existing floodlighting with REDU accident (Central laid out in Appendix C. green “H” – in compliance with
TD/PM circle and ‘H’ lighting North Sea) in February Surface mounted helideck Appendix C. Any deck-mounted
systems for the take-off, 2009 refers floodlights may be provided floodlighting systems already
approach and landing. for on-deck operations such present around the helideck may be
CAP 437 6th Edition CAP 437 7th Edition More demanding MD Applicability to new build Applicability to existing installations
requirement / reference requirement / reference Less demanding LD installations / vessels / vessels – including refurbishments

Floodlights may be retained as refuelling and passenger retained as a source of illumination


for on-deck operations such handling on installations for on-deck operations and as a
as refuelling and/or as a where the cultural lighting back-up to the new lighting scheme
back-up to the new lighting from other sources is typically and/or redeployed for other uses;
scheme. low. but should not be switched on for
take-off and landing.

Chapter 5, Section 2.6 and Chapter 5, Section 2.6 and LD – to take advantage Designers of new build Where systems are refurbished an
2.10 Foam concentrates 2.10 Foam concentrates of introduction of level C installations now have a opportunity arises for existing
applied through a Fixed applied through a Fixed foams in Annex 14 choice to provide level B installations perhaps to make use of
Monitor System (FMS) or a Monitor System (FMS) or a Volume I. foams requiring an application more effective performance level C
DIFFS should meet a DIFFS should meet rate of 6.0 litres per square concentrates. For existing NUIs
performance level B standard performance level B or level metre per minute or level C further options such as CAFS may
C standard foams requiring an application be utilised. Appendix E letter to
rate of 3.75 litres per square industry of 1 July 2011 refers.
metre per minute.

Chapter 5, Section 2 Chapter 5, Section 2. New MD Systems installed on new The objective should be assessed
Para 11. A DIFFS should builds completed on or after for all existing installations and
No detailed performance meet a performance 15 November 2013 should vessels that utilise a DIFFS. Duty
specification for the delivery objective to ensure that meet the minimum holders may be required to
pattern (minimum there is sufficient overlap of performance objectives. demonstrate ‘fitness for purpose’ to
application) from each the individual nozzles to a competent organisation.
component nozzle of a DIFF achieve an average
system prescribed. theoretical distribution over
the entire landing area with
no portion of the helideck
falling below two thirds of
the specified rate.

Existing installations and vessels


Chapter 5, Section 4. 9Kg of Chapter 5, Section 4. LD New build installations and should select dry powder and
halogenated hydrocarbon or Standards mirrored from 6th vessels should select dry gaseous agents for optimum
18Kg of CO2 complementary edition except prescribed powder and gaseous agents effectiveness. Agents discharging at
agent should be provided minimum application rate is for optimum effectiveness. rates prescribed by 6th edition will
CAP 437 6th Edition CAP 437 7th Edition More demanding MD Applicability to new build Applicability to existing installations
requirement / reference requirement / reference Less demanding LD installations / vessels / vessels – including refurbishments

from 1 or 2 extinguishers. replaced with a requirement usually be acceptable.


to select for “optimum
effectiveness”

Chapter 5, Section 5. For Chapter 5, Section 5. For


existing NUIs reference to new build NUIs an FMS is MD New build NUIs should select Existing installations should provide
UKOOA Guidelines, 5th not recommended. DIFFS is DIFFS that incorporate a retrofit solutions in accordance with
edition. For new builds the preferred solution with a method of fire detection and CAA letter of 1 July 2011. CAA
serious consideration for the method of fire detection/ are configured to avoid letter is reproduced at Appendix D.
selection and provision of a configured to avoid spurious spurious activation. Cut-off for compliance by 30 June
foam DIFFS. activation. 2014 for higher intensity NUI
helidecks and by 30 June 2017 for
standard and lower intensity NUI
helidecks.

Chapter 5, Section 9. PPE Chapter 5. Section 9. PPE N/A New build installations should Existing installations should review
prescribed to include a selection to be “appropriate” select appropriate Personal provision of Personal Protective
recommendation for at least in accordance with HSE Protective Equipment on the Equipment against HSE PPEWR
two positive pressure BA requirements PPEWR and basis of HSE PPEWR and and PUWER.
sets. PUWER. PUWER.

Chapter 6, Section 3. HMS


Chapter 6, Section 3. to measure several new Helideck Motion Systems to HMS software upgrades to ensure
Helideck movement. HMS parameters including MD measure and report new all the required landing limit
operational landing limits to significant heave rate, parameters landing limits and parameters can be measured and
measure P/R/H helideck inclination (new in future to adopt the MSI. reported. Failure to upgrade could
parameters to be reported lead to imposition of severe
on pre-flight weather restrictions
reports).

Chapter 9, Section 2 – Chapter 9, Section 2 – MD – to comply with Applicable to all new builds Applicable to all existing vessels
obstacle protected surfaces. obstacle protected surfaces. update of Annex 14 with a certificated D-value of with a certificated D-value of
Volume II (now 16.00m or less completed on 16.00m or less in so-far as they are
Essential objects around Essential objects for scheduled for adoption or after 15 November 2013. required to review the obstacle
CAP 437 6th Edition CAP 437 7th Edition More demanding MD Applicability to new build Applicability to existing installations
requirement / reference requirement / reference Less demanding LD installations / vessels / vessels – including refurbishments

210° sector should not helidecks with a D-value of in 2013) environment to remove, lower or
exceed 25 cm ADL (Para 16.00m or less should not mitigate as far as practical any
2.2.2) exceed 5 cm in the OFS objects that exceed 5 cm ADL.
(Para 2.2.2) Objects, whether or not essential
that exist >25 cm ADL for any
shipboard heliport (regardless of D-
value) should be removed at the
earliest opportunity. Actions to be
completed by no later than 15
November 2013.

Chapter 9 Section 3. Figure Chapter 9, Section 2, Figure Applicable to all new builds All existing shipboard heliports with
2. The whole number D- 2. The whole number D- with a certificated D-value of a D-value 15.00 m or greater should
value painted in three value painted in three MD - to comply with 15.00m or more completed on display whole number D-values
locations around the helideck locations around the update of Annex 14 or after 15 November 2013. around the perimeter which are at
should be a minimum helideck should be a Volume II (now For D-values less than least 90 cm high. For D-values less
character height of 60 cm minimum character height of scheduled for 2013) 15.00m the D-value character than 15.00m the D-value character
90 cm for D-values height may remain at (not less height may remain at 60 cm.
>15.00m. than) 60 cm. Characters should be increased at
the next convenient opportunity but
by no later than 15 November 2013.

Chapter 10, Section 2. Chapter 10, Section 2 N/A To be applied to all new build N/A
Helicopter Winching Areas Helicopter Winching Areas platforms with immediate
on Wind Turbines. Surface of on Wind Turbines. Surface effect.
the platform in 2.1.9 of the platform in 2.1.9 with
“essentially flat”. 2% slope to prevent pooling
of liquids.

Chapter 10, Section 2, Chapter 10, Section 2, MD To be applied to all new build To be repainted at the next
Paragraph 2.3.1 and Figure Paragraph 2.3.1 and Figure platforms with immediate scheduled repaint.
2. Safety zone grey all other 2. Safety zone green, effect.
areas yellow. access route grey and
CAP 437 6th Edition CAP 437 7th Edition More demanding MD Applicability to new build Applicability to existing installations
requirement / reference requirement / reference Less demanding LD installations / vessels / vessels – including refurbishments

winching area platform


yellow.

Chapter 10, Section 2, Chapter 10, Section 2, MD To be applied to all new build Providing the existing arrangement
Paragraph 2.3.4 initial Paragraph 2.3.4 revised platforms once the trails have is proven satisfactory (based on an
specification for heli-hoist specification for heli-hoist been completed and suitable actual operational assessment)
status light based on light in status light pending in- products become there is no need to change the light
other sectors. service trials. commercially available. until, subject to review and
replacement at the next
maintenance cycle.

Chapter 10, Section 2, Chapter 10, Section 2, LD No fixed red obstruction light Where a fixed red low intensity
Paragraph 2.3.5. Paragraph 2.3.5. is required for new build obstruction light is fitted on an
Requirement for a low Requirement for a low platforms. existing platform this may be
intensity fixed red obstruction intensity fixed red retained. However, there would be
light. obstruction light is removed. no penalty imposed on a platform
where the light subsequently goes
unserviceable or is removed.

Disclaimer: This document is not intended to record every difference between CAP 437, Edition 6 and Edition 7, but is intended only to highlight
areas of significant change.