LEGAL INFORMATION
By accepting this certain document of ZTE CORPORATION you agree to the following terms. If you do
not agree to the following terms, please notice that you are not allowed to use this document.
Copyright © 2015 ZTE CORPORATION. Any rights not expressly granted herein are reserved. This
document contains proprietary information of ZTE CORPORATION. Any reproduction, transfer,
distribution, use or disclosure of this document or any portion of this document, in any form by any
means, without the prior written consent of ZTE CORPORATION is prohibited.
are registered trademarks of ZTE CORPORATION. ZTE’s company name, logo and product
names referenced herein are either trademarks or registered trademarks of ZTE CORPORATION.
Other product and company names mentioned herein may be trademarks or trade names of their
respective owners. Without the prior written consent of ZTE CORPORATION or the third party owner
thereof, anyone’s access to this document should not be construed as granting, by implication,
estoppel or otherwise, any license or right to use any marks appearing in the document.
The design of this product complies with requirements of environmental protection and personal
security. This product shall be stored, used or discarded in accordance with product manual, relevant
contract or laws and regulations in relevant country (countries).
This document is provided “as is” and “as available”. Information contained in this document is subject
to continuous update without further notice due to improvement and update of ZTE CORPORATION’s
products and technologies.
ZTE CORPORATION
Address: NO. 55
Hi-tech Road South
ShenZhen
P.R.China
518057
Website: http://dms.zte.com.cn
Email: TSM.Aftersales@zte.com.cn
ZXMW NR8250 Quick Installation & Commissioning Guide
1 Overview
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 1(5)
ZXMW NR8250 Quick Installation & Commissioning Guide
Crystal-connector Grounding
Wire punchdown tool Hex wrench
crimper resistance tester
Start
IDU Installation
ODU Installation
Power cable
Protective grounding cable
Cable Installation
IF cable
Signal cable
Antenna Adjustment
Installation Check
Power- on/off
Commissioning
End
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 3(7)
ZXMW NR8250 Quick Installation & Commissioning Guide
2 Pre-installation Check
SN Check Point Picture Check Key Point
Equipment List:
According to when unpacking
Check the case of equipment list
1 installation None inventory goods, microwave
parts devices delivery when IDU,
ODU, and is Antenna separate
packaging
Under the
BLVD port is available and
secondary
2 current equipment meet
electric power
Microwave power combined.
supply
3 Equipment Installation
Caution:
For antennas larger than 1.2m, reinforcing poles are needed for windproof.
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 5(9)
ZXMW NR8250 Quick Installation & Commissioning Guide
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 7(11)
ZXMW NR8250 Quick Installation & Commissioning Guide
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 9(13)
ZXMW NR8250 Quick Installation & Commissioning Guide
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 11(15)
ZXMW NR8250 Quick Installation & Commissioning Guide
1 X_IN X_OUT
2 X_OUT X_IN
XPIC Cross-Connect
RMUC (Slot 5) RMUC(Slot 6) RMUC(Slot 7) RMUC(Slot 8)
Cable No.
1 X_IN - X_OUT -
2 X_OUT - X_IN -
3 - X_IN - X_OUT
4 - X_OUT - X_IN
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 13(17)
ZXMW NR8250 Quick Installation & Commissioning Guide
4 Antenna Adjustment
Vertical polarization.
The polarization arrow on the feeder source is aligned with the mark "V" on the
antenna.
Picture Note
Horizontal polarization:
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 15(19)
ZXMW NR8250 Quick Installation & Commissioning Guide
The polarization arrow on the feeder source is aligned with the mark "H" on the
antenna.
Step
Note:
The horizontal polarization adjustment uses the same method as the vertical polarization
adjustment. Users can perform adjustment in accordance with the actual requirement.
If the fine adjustment range is not big enough, users can change the position of the
anti-falling angle steel and continue the adjustment. The U-type clamp must be used
to fix the bracket in adjusting the anti-falling angle steel position.
Step
ii. Loosen the nut on the U-type clamp and the fixing screw above the reinforcing
pole.
iii. Use hand to push the antenna or reinforcing pole gently, and adjust the
antenna azimuth around the pole.
Caution:
During the adjustment, be very careful not to make the clamp fall from the anti-falling angle
steel lest any accident might occur.
2. In accordance with the circuit design, determine the antenna azimuth through
visualization or a compass, and adjust the antenna azimuth.
3. After the adjustment is completed, fasten all components that are loosened.
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 17(21)
ZXMW NR8250 Quick Installation & Commissioning Guide
Step
3. Adjust the antenna downtilt, and fasten the downtilt fine-adjustment nut tightly.
5 Installation Check
SN Checking Items Result
The antenna, combiner, ODU installation bracket and ODU are within the
lightning rod's protection range. The protection angle of the antenna's lightning □Pass
1
rod must be less than 45°. In areas with high mountains or frequent □Fail
thunderstorm, the protection angle must be less than 30°.
Waterproof and sealing handling must be performed for all outdoor connectors □Pass
3
and grounding clips in accordance with the specification. □Fail
The IF cable is not folded or twisted, and the shielding layer is not bare. After □Pass
4
the IF cable is led out of ODU, make the waterproof bend for it. □Fail
The cabinet's grounding cable, IDU's and ODU's grounding cable are □Pass
5
connected properly. □Fail
Start
End
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 19(23)
ZXMW NR8250 Quick Installation & Commissioning Guide
Start
Yes
Whether there is any Back up the data and implement
data to be backed up? performance statistics
No
Turn off the power cabinet
connected to the IDU
End
7 Commissioning
If the project has a DLD or LLD file, all date sources are from DLD or LLD file.
If the project is not DLD file, data sources, respectively from the DO, Link Summary,
and Service Planning Table.
Before commissioning, please check the connection of the E1 line impedance and
inserted board of impedance match, if not match, please refer to the Hardware
Installation Guide to complete the corresponding impedance E1 jump line.
In this document, the commissioning only contains basic wireless parameters and
IDU network configuration, other services configuration refer to Configuration Guide.
Please input the login IP in IE browser address bar, enter the login page.
1 The IP address is:192.168.X.16 or 192.254.X.16
Note: x represents the slot number of master RCU board, its value is 1 or 2.
Enter admin in User Name and Password, click LOGIN to log in to WEB LMT.
Initial configuration: Select Setup > System > Parameter. Configure Site ID/NE ID/Device IP
address/Subnet Mask/Default Gateway.
Sources of Data: Site ID and NE ID taken from Link Summary, Device IP address/Subnet
Mask/Default Gateway taken from Service Planning Table
Initial configuration: Select Setup > System > Time, configure Time Zone Management.
4
Select local time zone in Time Zone Management drop-down box.
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 21(25)
ZXMW NR8250 Quick Installation & Commissioning Guide
Summer Time Management: Enable the Summer Time, and sets the start time and end time
of the DST system.
Configuring Board: Select Setup > Shelf. The shelf and board configuration page is displayed.
Based on the physical boards actually inserted in Indoor Unit (IDU)'s slots, set the following
information for each Slot NO.: Board Type.
Sources of Data: DO Bills
Configuring the Connection Between NE and NMS: Select Setup > NMS. The NMS
6
configuration page is displayed.
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 23(27)
ZXMW NR8250 Quick Installation & Commissioning Guide
Transmission Unit Information: Select Radio Link > Basic Configuration. Select slot number
of the desired configuration in Transmission Unit Name. Set Name/Link ID in Transmission
Unit Information. click Apply.
Sources of Data: Service Planning Table and Link summary
RF Parameter Configuration: Ensure that the Current Tx frequency and Set Tx Frequency are
the same, and Current TX Power and Set Tx Power are the same.
Select frequency space in T/R Spacing. If select Other in T/R Spacing, you need set channel
frequency in RX Frequency Configuration.
Sources of Data: Link summary
Select Radio Link > Basic Configuration > RF Parameter Configuration, the RF
Parameter Configuration is displayed. Check whether Current RSL and both ends reception
level and the design of the Link Summary value consistent. (RSL should be 3 dB more or less
than the design value.)
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 25(29)
ZXMW NR8250 Quick Installation & Commissioning Guide
Check RMUX board panel lights, if the LINK light for the green normally on, shows that the link
is normal.
Select Radio Link >Neighbor NE, the Neighbor NE is displayed. Check the opposite end NE
information, and click the opposite end NE IP Address, If you can log in to the end of the IDU
equipment, it indicates that the link has been properly opened.
Check link XPI value for XPIC configuration. Follow customers’ requirements on XPI value
(normally not lower than 25).
Select Performance > XPIC > 15 Min, the XPIC 15minute Performance statistics is displayed.
Select slot number in Position and query date in Date, click Query.
If the link is invalid while configurations are correct, please use ETP-Debugger tool to collect
5
IDU information and feedback to troubleshooting staff of microwave product support team.
If the antenna is installed on the metal tower, the IF cable should be grounded at a
point about 1-2 m below the ODU, and then be grounded at a point 1.5 m before the
bent part where the cable is routed downwards along the tower. Before the IF cable
is led into the equipment room, the cable must also be grounded at a grounding
point.
If the IF cable is shorter than 20 m, it must be grounded at the first two grounding
points, as mentioned above.
If the IF cable is longer than 20 m but shorter than 60 m, it must be grounded at the
three grounding points, as mentioned above.
If the IF cable is longer than 60 m, an additional grounding point must be made for
every additional 20 m IF cable.
1. Select a proper position to install the grounding clip, and cut the IF cable sheath in
accordance with the grounding clip size. The following figure shows the structure of
the grounding clip.
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 27(31)
ZXMW NR8250 Quick Installation & Commissioning Guide
1. Grounding terminal 2. Grounding cable 3. IF cable 4. Grounding cable clamp spring 5. Outer copper wire of the IF
2. Route the down-lead of the grounding clip connected by the IF cable towards the
grounding network, and verify that the included angle between the grounding cable
and the IF cable must be not more than 15°.
3. Waterproof and seal the connection part between the grounding clip and the IF
cable in "1+3+3" mode, which involves one layer of PVC insulating tape, three
layers of waterproof cement, and three layers of insulating tape.
The waterproof handling tapes are wrapped on the connector until 3-5 cm below it.
step Picture Note
ZTE Confidential Proprietary © 2015 ZTE Corporation. All rights reserved. 29(33)