Job Name/Location: Tag #:

Date: For: File Resubmit


PO No.: Approval Other
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)

ARUN192BTE4 (a) ARUN072BTE4
Multi V™ IV Heat Pump (b) ARUN121BTE4
16.0 Ton Outdoor Unit
Performance: Operating Range:
Cooling Mode: Cooling (˚F DB)** 14‐122
Nominal Capacity (Btu/h) 192,000 Heating (˚F WB) ‐13 ‐ 61
Power Input¹ (kW) 12.20
Unit Data:
Heating Mode: Refrigerant Type R410A
Nominal Capacity (Btu/h) 216,000 Refrigerant Control EEV
Power Input¹ (kW) 14.23 Max Number of Indoor Units³ 32
Sound Pressure⁴ dB(A) 61.8
Nominal Capacity is outside the scope of AHRI Standard 1230 and based on the following conditions:
Indoor: 80°F DB / 67°F WB Indoor: 70°F DB Net Unit Weight (a) + (b) (lbs) 430 + 540
Outdoor 95°F DB Outdoor 47°F DB / 43°F WB
: : Shipping Weight (a) + (b) (lbs) 452 + 573
Electrical: (a) ARUN072BTE4 (b) ARUN121BTE4 Communication Cable⁵ (No. x AWG) 2 x 18
Power Supply  (V/Hz/Ø) 208‐230/60/3 208‐230/60/3 Heat Exchanger Coating GoldFin™
MOP (A) 40 60
MCA (A) 25.3 40.3
Compressor:
Rated Amps (A) 21.0 33.4 Type HSS DC Scroll
Compressor A (A) 17.0 27.4 Quantity 2
Oil / Type PVE/FVC68D
Compressor B (A) ‐ ‐
Fan (A) 4.0 6.0 Fan:

Piping: (a) ARUN072BTE4 (b) ARUN121BTE4


Type Propeller
Quantity (a) + (b) 3
Refrigerant Charge (lbs) 16.9 23.6
Motor/Drive Brushless Digitally Controlled/Direct
Liquid Line² (in, OD) 3/8 1/2
Air Flow Rate (a) + (b) (CFM) 17,600
Vapor Line² (in, OD) 3/4 1‐1/8
Notes:
Standard Features: 1.For AHRI ra ngs, refer to the AHRI website h p://www.ahridirectory.org.
2.For main pipe segment size, refer to the LATS Mul  V tree diagram.
•HiPOR (high pressure oil return) 3.The combina on ra o must be between 50‐130%.
•Smart Oil Control 4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745 for the 
combination of outdoor units.
•Split Frame Defrost 5.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and 
•Night Quiet Opera on must comply with applicable local and national code.  Cables terminate at each frame.
6.Nominal data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and 
•Fault Detec on and Diagnosis a 0 ft level difference between outdoor and indoor units.  All capacities are net with a 
combination ratio between 95‐105%.
Required Accessories: 7.Power wiring cable size must comply with the applicable local and na onal code.  Cables 
terminate at each frame.
ARCNN21 (frame connector Y‐branch) 8.The voltage tolerance is ± 10%.

Optional Accessories:
Air Guide ‐ PRAGX2S0 (1), Air Guide ‐ PRAGX3S0 (2 required)
Low Ambient Baffle Kit ‐ ZLABKA01A (1), Low Ambient Baffle 
Kit ‐ ZLABKA03A (1)
**(‐9.9°F achieved only when all IDU's are operating in cooling mode.)

LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg‐vrf.com
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com SB‐MultiV_IV_HeatPump‐ARUN192BTE4‐01‐15 Page 1 of 2
Job Name/Location:
(a) ARUN072BTE4 Tag #:
ARUN192BTE4
Multi V™ IV Heat Pump (b) ARUN121BTE4 Date:
16.0 Ton Outdoor Unit PO No.:

LG Electronics USA, Inc. 1000 Sylvan Ave, Englewood Cliffs, NJ 07632/www.lg‐vrf.com
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com SB‐MultiV_IV_HeatPump‐ARUN192BTE4‐01‐15 Page 2 of 2