Anda di halaman 1dari 4

Dania Air Control System Factory

P.O. Box 60479 Riyadh 11545 K.S.A.


ROUND
DIFFUSERS
Tel. No. 01 453-6181 / 453-6072 Fax No. 01 453-6385
Email: dania@sunaid.com.sa
Dania Air Control System Factory
P.O. Box 60479 Riyadh 11545 K.S.A.
Tel. No. 01 453-6181 / 453-6072 Fax No. 01 453-6385
Email: dania@sunaid.com.sa

ROUND DIFFUSERS

PRODUCT FEATURES

Model : RD
Round Diffusers with Fixed Patterns
RD Supply Diffusers are recommended for heating,
ventilating and cooling. Equipped with flush cores for
matching architectural requirements for flush appearance.
Fixed air pattern with wide performance range, all accessory
adjustment easily made w/o disturbing ceiling or removing
diffuser. Duct rings for mounting furnished as standard.
Diffuser outer shell fasten directly to duct ring with concealed
fasteners.

SUPPLY DIFFUSER :
With No. 5 Butterfly Damper.

RETURN DIFFUSER :
WithOUT Damper.

MATERIALS
ALUMINUM pressed formed as standard up to 20” Ø.

FINISH
Standard RAL9016 or RAL 9010 White Powder Coated
finished.

Listed Sizes : (Quick Guide )

Diameter
Cores CFM Range NC Level
(in)
6 2 60 - 200 10 - 30
8 2 105 - 280 10 - 30 HOW TO ORDER :
10 3 165 - 490 10 - 30 • TYPE
• LISTED SIZE
12 3 235 - 705 10 - 30 • FINISH
14 3 320 - 750 11 - 30
16 3 420 - 1100 15 - 30
18 3 530 - 1420 15 - 30
20 3 655 - 1750 15 - 30

Page 1
IMPORTANT NOTICE : DANIA Reserves the Rights to alteration. Designs are subject to change without prior notice.
Dania Air Control System Factory
P.O. Box 60479 Riyadh 11545 K.S.A.
Tel. No. 01 453-6181 / 453-6072 Fax No. 01 453-6385
Email: dania@sunaid.com.sa

ENGINEERING PERFORMANCE

ENGINEERING PERFORMANCE DATA


Neck
Neck Neck Velocity 300 400 500 600 700 800 900 1000 1200 1400 1600
Size Area (fpm)
(in.) (sq.ft.) Velocity Pressure
(Inches W.G.) .006 .010 .016 .023 .031 040 .051 .063 .090 .122 .160
Flow rate ,CFM 60 80 100 120 140 160 180 200 235 275 315
6” 0.196 Radius of diff. Ft. 1-2-3 2-2-4 2-3-5 2-4-6 3-4-7 3-5-8 4-5-9 4-6-10 7-7-11 6-5-13 6-10-15
NC - - - 14 19 23 26 30 35 40 44

Flow rate ,CFM 105 140 175 210 245 280 315 350 420 490 560
8” 0.349 Radius of diff. Ft. 1-2-3 2-4-6 3-4-7 4-5-9 4-6-10 5-7-11 5-8-13 6-9-14 7-11-17 8-13-20 10-14-23
NC - - 15 21 26 31 34 37 44 48 53’

Flow rate ,CFM 165 220 270 330 380 435 490 545 655 765 870
10” 0.545 Radius of diff. Ft. 2-3-4 3-4-7 3-5-8 4-6-10 5-7-11 5-8-13 6-9-15 7-10-16 8-12-20 10-14-23 11-16-26
NC - - 11 17 21 26 30 33 39 44 48

Flow rate ,CFM 235 315 390 470 550 630 705 785 940 1100 1255
12” 0.785 Radius of diff. Ft. 2-3-4 3-5-8 4-6-10 5-7-12 6-8-13 6-10-15 7-11-17 8-12-19 8-12-19 10-14-23 11-17-27
NC - - 11 17 22 26 30 33 39 45 49

Flow rate ,CFM 320 425 530 635 745 850 955 1060 1270 1490 1695
14” 1.07 Radius of diff. Ft. 3-4-5 4-6-10 5-8-12 6-9-15 7-11-17 8-12-20 9-14-22 10-15-24 12-18-29 14-21-34 16-24-29
NC - 11 18 23 28 32 36 40 46 51 55

Flow rate ,CFM 420 560 700 840 980 1120 1260 1400 1680 1960 2240
16” 1.40 Radius of diff. Ft. 3-5-6 5-7-11 6-9-14 7-10-16 8-12-19 9-14-22 10-15-24 11-17-27 14-20-33 16-24-38 18-27-43
NC - - 16 22 27 31 35 39 44 49 53

Flow rate ,CFM 530 710 885 1060 1240 1420 1590 1770 2120 2480 2830
18” 1.77 Radius of diff. Ft. 3-5-7 5-7-12 6-9-15 7-11-18 9-13-21 10-15-24 11-17-27 12-19-30 15-22-36 17-26-42 20-30-48
NC - - 15 21 26 30 34 37 43 48 52

Flow rate ,CFM 655 875 1100 1310 1530 1750 1970 2190 2610 3060 3500
20” 2.18 Radius of diff. Ft. 4-6-7 6-8-13 7-10-17 8-12-20 10-14-23 11-17-27 12-19-30 14-21-33 16-25-40 19-29-36 22-33-53
NC - - 16 21 26 30 34 38 43 48 52

BALANCING DATA

To Determine CFM :
1. Position the Tip as shown and a take minimum of 6 readings around the
perimeter of the diffuser.
2. Average the measured velocities.
3. Select proper Ak from Table Below using diffuser size.
4. Determine CFM by the following equation :
CFM=Ak x AVERAGE VELOCITY

Listed Size 6” 8” 10” 12” 14” 16” 18” 20”


AK Outlet Area 0.14 .25 .39 0.54 0.7 0.91 1.1 1.5

• Minimum radii of diffusion are to a terminal velocity (VT) All pressures are in inches of water. To obtain velocity
of 150 fpm, middle to 100 fpm and 75 fpm. If the pressure (PV) , subtract the static pressure (PS) at the
diffuser is mounted on an exposed duct, multiply the radii head of the column from the total pressure (PT)
of diffusion shown by 0.70.

• The NC values are based on a room absorption of 10 db,


12
re 10- watts. Values shown are for horizontal pattern,
add 1 db for vertical pattern. The NC data in the
performance table are only for outlets.

Page 2
IMPORTANT NOTICE : DANIA Reserves the Rights to alteration. Designs are subject to change without prior notice.
Dania Air Control System Factory
P.O. Box 60479 Riyadh 11545 K.S.A.
Tel. No. 01 453-6181 / 453-6072 Fax No. 01 453-6385
Email: dania@sunaid.com.sa

DIMENSIONS & ACCESSORIES

Overall Ceiling
Neck Size Neck Size
Face Size Opening
D+E
(in.) (mm) (mm)
(mm) (mm)
6” 142 mm 328 mm 278 mm 52 mm
8” 192 mm 428 mm 378 mm 60 mm
10” 247 mm 533 mm 483 mm 81 mm
12” 290 mm 552 mm 502 mm 95 mm
14” 348 mm 698 mm 648 mm 102 mm
16” 400 mm 806 mm 749 mm 114 mm
18” 451 mm 876 mm 826 mm 127 mm
20” 501 mm 953 mm 895 mm 133 mm

NO. 5 DAMPER (for SUPPLY DIFFUSER)


A butterfly damper that provides simple, easy and economical
control of air volume. Friction pivots on heavy – gauge metal
blades, keep blades at desired setting. Can be mounted directly
on diffuser. Fully adjustable by opening diffuser face. Steel
Construction baked –black painted finish.

Page 3
IMPORTANT NOTICE : DANIA Reserves the Rights to alteration. Designs are subject to change without prior notice.

Anda mungkin juga menyukai