5000iPS
CHAPTER IV UPGRADE
CONTENTS
1. UPGRADE CONCEPT.................................................................................................. 1-1
1.1. General ...................................................................................................................................1-1
1.2. Upgrade Notice .......................................................................................................................1-1
2. HARDWARE UPGRADE.............................................................................................. 2-1
2.1 General ...................................................................................................................................2-1
2.2 Wrist Strap Connection ...........................................................................................................2-1
2.3 Hardware Upgrade Notice ......................................................................................................2-2
3. SOFTWARE LICENSE UPGRADE .............................................................................. 3-1
3.1 General ...................................................................................................................................3-1
3.2 Software License Upgrade......................................................................................................3-1
APPENDIX 1. 5000S/IP HYBRID UPGRADE................................................APPENDIX1-1
A1.1. General .................................................................................................................APPENDIX1-1
1. UPGRADE CONCEPT
1.1. General
The 5000iPS can upgrade the channel, redundancy, interface, and auxiliary function by
hardware configuration change and software license upgrade.
When you perform the upgrade, it is recommended to contact NEC to make your upgrade
plan.
2. HARDWARE UPGRADE
2.1 General
Before the upgrade operation, it is recommended to read carefully SAFETY
INFORMATION.
NOTE: Even if turning off the power supply, some modules keep hot surface.
Procedure 2-1
1. Wear an Antistatic Wrist Strap, and check that metal plate contacts to the skin
exactly.
2. Connect the other end to the Earth Bonding Point (EBP)in the side of the MDP
section.
EBP
3. Especially noted that, even if using an Antistatic Wrist Strap, take care that do NOT
touch the electrical device on the printed circuit boards.
This operation is equivalent to replace, therefore, some change procedure refers the
mounting portion of CHAPTER III MAINTENANCE- 9.4 Replacement Procedure.
NOTE: The upgrading procedures with cable routing must be operated with turning OFF the re-
lated Power Supply switch for safety of the operation. The procedure No. means in ex-
ample that "C-III-S-9" as "Chapter III MAINTENANCE - Section 9".
3.1 General
Some functions need the software license to become active. And some upgrade procedures
need the hardware addition and software license upgrade.
Procedure 3-1
1. Expand the S/W License Setup from the LCT menu.
2. Select the Import License Key from the S/W License Setup sub menu.
6. Click OK button.
7. Click OK button.
8. Confirm that the Import License Key window performed at the step-3 described
above is updated correctly.
Note When License assignment change is needed, operate the procedure in accordance
with Chapter III MAINTENANCE - Section 8.2.3 Software License Key
Information.
A1.1. General
The 5000S in service can be upgraded to 5000S TRP + 5000iPS MDP configuration or
5000S / IP Hybrid configuration explained in Chapter I GENERAL Appendix 1.
And, some upgrading operations need the technical skill of the NEC maintenance
engineers. When needed, contact NEC.