Anda di halaman 1dari 35

Parameter Kerja Gas Turbine

General Parameter (Alstom’s GT26 - ISO 2314 : 1989)

No. Parameter Satuan Standar


1 Load MW 300
2 Frequency Hz 50
3 Turbin Speed RPM 3000
4 Compressor Inlet Pressure Kpa 100
5 Compressor Inlet Temperature o
C 20
6 Exhaust Temperature o
C 615
7 Ambient Temperature o
C 30
8 Site Barometer atm 1
9 Flue Flow kg/s 11
10 Net Heating Value (Natural Gas ) kcal/kg 9722.3 - 12222.32
11 Fuel Temperature o
C 185

Inspeksi Dampak Lingkungan

No. Parameter Satuan Standar Gas

1 Kebisingan dB 85
2 NOx emissions mg/Nm^3 320
3 SO2 emissions mg/Nm^3 150
4 Total Partikulat mg/Nm^3 30
5 Opasitas % -
Hasil Pengujian Rekomendasi

Standar Minyak Hasil Pengujian Rekomendasi

85
450
650
100
20
Generator Section

Load Test
Load Percentage %
No Parameter 25 50
1 Daya
2 Arus
3 Tegangan
4 Faktor Daya
5 Frekwensi
6 Temp. Bearing

Parallel Synchronous Mode


Load Share Test
No Parameter
Generator 1 Generator 2
1 Cos Phi
2 Frekwensi
3 Daya
4 Arus
5 Tegangan

Sistem Proteksi
Load Percentage %
No Parameter
25 50
1 Sistem Interlock
2 Over Speed Protection
3 Under Speed Protection
4 Over Frequency Protection
5 Under Frequency Protection
6 Over Heat Frequency

Peralatan Dukung

No Coolant System Measure Satuan


1 Level Tank Coolant ft
2 Pressure Tank Coolant Bar
3 Temperature Outlet Tank Coolant K

No Voltage Regulator Measure Satuan


1 Mode Auto/Manual
2 Supply Input V
3 Power Consumtion W
4 Signal Input Hz
5 Relay Capacity VA
5 Ambient Temperature K

No Exitation System Measure Satuan


1 Im mA
2 E0 V
3 Isc A
4 Zs Ohm
5 Xs Ohm
6 Diode Baik/Tidak
7 Sikat Arang Baik/Tidak
8 Rheostat Baik/Tidak
erator Section

Load Percentage %
75 100 110
Satuan
MW
Ampere
Voltage
cos phi
Hz
K

Load Shift Test


Satuan
Generator 1 Generator 2
-
Hz
MW
A
V

Load Percentage %
Keadaan
75 100 110
Baik / Tidak
Baik / Tidak
Baik / Tidak
Baik / Tidak
Baik / Tidak
Baik / Tidak

Parallel Generator Diagram


Exitation System Diagram
Fuel Sect
Tanggal Pemeriksaan :

Hasil Pemeriksaan
No. Peralatan
Ada/Sesuai Tidak Ada/Tidak Sesuai
1 Bunker
2 Sum tank
3 Pembumian
4 Katup
5 Regulator
6 Filter
7 Control Level
8 Alat Pengukuran
9 Piping
10 Venting
11 Stasiun gas
12 Fuel treatment
13 Fuel skid
14 Inhibitor
Fuel Section

No Parameter Unit standar


Keterangan Kondisi
1 Kapasitas Bunker Liter
2 Resistansi Grounding W
3 Tekanan suction pompa kg/cm2
4 Tekanan discarge pompa kg/cm2
5 Tegangan pompa V
6 Arus pompa A
7 Kapasitas Sumtank m3
Hasil Pemeriksaan Keterangan
Aux. Componenet Section

SISTEM AIR PENDINGIN (WATER COOLING SYSTEM)

No. Parameter Satuan Standar

1 Tangki Air Pendingin


Tekanan kPa
Level cm

Temperature C
o

2 Katup

Tekanan Inlet kPa

Tekanan Outlet kPa

3 Relief Valve

Tekanan Inlet kPa

Tekanan Outlet kPa

4 Regulator

Tegangan Volt

5 Control Level
Level cm
6 Ventilating
Tekanan kPa
7 Radiator
Temperature Inlet o
C
Temperature Outlet o
C
Tekanan Inlet kPa
Tekanan Outlet kPa
8 Cooling Air Fan
Putaran RPM
Tekanan kPa
Temperature C
o

9 Motor
Arus Ampere
Tegangan Volt

SISTEM UDARA PENGABUT


No. Parameter Satuan Standar
1 Atomizing Air Compressor DC/AC
Tekanan Inlet kPa
Tekanan Outlet kPa
2 Sabuk Jalan
Tightness mm
3 Katup
Tekanan Inlet kPa
Tekanan Outlet kPa
4 Reliev Valve
Tekanan Inlet kPa
Tekanan Outlet kPa
7 Regulator
Tegangan Volt
9 Ventilating
Tekanan kPa
11 Piping
Conductivity S/m
Thickness mm
12 Sistem Kontrol Tekanan
Tekanan kPa
ection

Hasil Pengujian Rekomendasi


Hasil Pengujian Rekomendasi
Transformator Section

Item Descriptions Unit


Rated power MVA
1 At ONAN cooling MVA
At ONAF cooling MVA
2 Number of phases
3 Rated frequency Hz
4 Number of windings
5 Applicable standards
6 Single or 3 phase units
7 Type of transformer
core or
8 Type of core
shell
System maximum voltage for both
9
winding
HV kV
LV kV
Insulation type
10 Primary
Secondary
Power frequency withstand voltage,
primary:
11 Line kV
Neutral kV
Lighting impulse level, primary:
12 Line kVp
Neutral kVp
Power frequency withstand voltage,
13 kV
secondary:
14 Lighting impulse level, secondary: kVp
Rated Voltage - No load
15 Primary kV
Secondary kV
16 Tap changer
17 Tapping range
18 Permissible loading of neutral
Phase connections:
Primary winding
19
Secondary winding
Vector Group
Short circuit withstand fault level at
terminals of:
20 245kV busbars GVA
Low-voltage busbars GVA
21 Type of cooling
22 External cooling medium

Item Descriptions Unit


Service conditions
23
Altitude not exceeding m
23 o
Air temperature not exceeding
C
Air temperature
o
Maximum in any one day
C
24 o
Monthly average, of the hottest month
C
o
Yearly average
C
Winding temperature rise at CMR to IEC o
25
60076 C
Top oil temperature rise (average daily
ambient air temperature 32 C
o
CRM to IEC 60076
26 C
o
ONAN rating
C
Maximum hot spot temperature when o
27
loaded according to IEC 60354 C
28 Hot spot factor
Flux density in iron at normal voltage and
frequency and at normal ratio (no load)
29 Core Tesla
Yokes Tesla
Transformer suitable for full load rejection
30 yes/no
according to IEC
Magnetizing 60076
current (approx) at nominal
ratio and
- at 0.9 x nominal voltage A
31 - at 1.0 x nominal voltage A
- at 1.1 x nominal voltage A
- at 1.2 x nominal voltage A
Guaranteed Losses at nominal ratio
No load losses kW
32
Copper losses at CRM kW
Auxiliary losses at CRM (for fans) kW
Regulation at 75 C and nominal ratio
33 At unity power factor %
At 0.9 lagging power factor %
Impedance voltage at 75 C and CRM
between HV and LV Windings at tap:
Maximum tap
%
Primary/Secondary (HV/LV1)
34 Nominal tap
%
Primary/Secondary (HV/LV2)
Minimum tap
%
Primary/Secondary (LV1/LV2)

Item Descriptions Unit


The short circuit level withstand of
35 kA/2s
10.5kV winding
36 Resistance voltage %max
Equivalent circuit zero sequence
37 ohms
impedance
Maximum current density in windings at
38 HV winding A/mm2
LV winding A/mm2
(b) General
1 Type of oil preservation system
Whether wheels, skid or flat bottom base
2
required
3 Whether anti-vibration pads required
4 Transformer noise acceptance level dB (A)
(c) Details of construction
1 Type of tank
2 Tank fully vacuum proof yes
Overall dimensions including bushings
Height mm
3
Depth mm
Width mm
Shipping Dimensions
Height mm
4
Depth mm
Width mm
Types of winding
5 HV
LV
Material of Insulation
6 HV windings
LV windings
7 Insulation of tapping connections
Insulation of:
8 Yoke bolts
Side plates
Winding connections blazed or crimped -
9 Specify material (Winding material and
Is
thefacility provided for adjustment of axial
joint material)
10 yes/no
pressure on windings
Thickness of transformer tank
11 Sides mm
Bottom mm
Material used for gaskets for oil tight
12
joints
Cover flange:
13
Level: Low/High

Item Descriptions Unit


Joint: WELDED/GASKET
(d) Radiators valves and fans
1 Number of radiators per transformer nos
Maximum rating of each radiator as
2 %
percentageof
Thickness ofradiator
total lossplates
at CRM
and/or cooling
3 mm
tubes
Valve type/material:
4 75mm and below
Above 75 mm
Equipment for ONAN cooling state a) or
b)
5
5 a) Radiator on main tank
b) Separate cooler bank
6 Number of cooling air blowers per
7 Speed of air blowers and air flow rpm m3/min
8 Rating of each air blower motor kW
(e) Oil volumes and weights
1 Total oil required including cooler system L
Volume of oil to fill transformer to above
2 L
the top yoke
3 Total volume of conservator L
Volume of oil in conservator between
4 L
highest and lowest visible
5 Weight of core
each and winding
oil cooler bankAssembly
complete kg
6 with oil if mounted separately from
Total weights of complete transformer, kg
7 transformer
including attached cooler, voltage kg
Weight
regulatingof transformer arranged
equipment, all fittingsfor
and oil
8 transport kg
(without oil)
(f) Transformer oil
IEC
1 Manufacture, type and class of oil 60296
Class II
Transformer parts
Brief description subject or
of transformer to parts
short-
(g)
circuit test
thereof subjected to short-circuit test for
1 yes/no
which short-circuit calculations are
(h) Transformer
available bushings 10.5kV
1 Manufacturer's
2 Rated normal voltage kV

Item Descriptions Unit


3 Minimum impulse withstand voltage kVp
Dry power frequency flashover voltage of
4 kV
bushings with all fittings
5 Insulating materials
6 Type of connection
Total creepage distance based on highest
7 mm/kV
system voltage
(k) Transformer bushing 220kV
1 Manufacturer's
2 Rated normal voltage kV
3 Minimum impulse withstand voltage kVP
Dry power frequency flashover voltage of
4 kV
bushings
Wet powerwith all fittings
frequency flashover voltage of
5 kV
bushings with all fittings
6 Insulating materials
7 Length overall mm
8 Weight of bushing complete with fittings kg
9 Electrostatic capacity of complate bushing pf
10 Materials of fittings Al
Total creepage distance based on nominal
11 mm/kV
system voltage
(i) Test
Routine tests according to IEC 60076 as
a
follows
Separatefor eachover
source unit voltage withstand
test
1 Primary kV
1
Secondary kV
Induced over voltage withstand test
Primary kV
2 Secondary kV
Test frequency Hz
Test duration min. 30
Patial discharge measurement:
Test voltage between line and neutral (at
central position)
U1= 3×Um/ 3=Um kV
3
U2= 1.5×Um/ 3 kV
Permissible partial discharges at U2 pC
test frequency Hz
Type test according to IEC 60076 as
b
follows (one unit)
Lighting impulse tests
1
Full wave

Item Descriptions Unit


Primary (line/neutral) kVp
Secondary (line/neutral) kVp
2 Temperature rise
Special tests according to IEC 60076 as
c
follows (one Unit)
1 Test of noise level dB (A)
Chopped wave tests
2 Primary kV
Secondary kV
3 Switching impulse tests kV
l Deviation from Tender Specification
(if necessary on extra sheet)
on

Data
100/60/60
70/42/42
100/60/60
3
50
3
IEC 60076
Three phase
Oil-immersed
core

245
10.5/10.5

Graded
Uniform

460
200

1050
400
50
125

230
10.5
On-Load (MR)
±8×1.25%
100%

Star
Star
Yny0yn0+d11

12
4
ONAN/ONAF
Air

Data
1000
40

38

36

27

IEC60076

IEC60076

IEC60076

118
< 1.2

1.7 max
1.7 max
Yes

0.3
0.5
2.6
6

50
330
8

0.34
4.5

≥ 18

≥ 18

≥ 36

Data
90
0.5
57
2.51
3.2

Conserator
Flat Bottom Base
No
70

Upper Flange Type


Yes

7500
6600
8500

3470
2600
7500

Interleaved
Helical

Pressboard
Pressboard
Pressboard

Pressboard
Pressboard
Crimped
yes

10
16
Nitrile Rubber

High

Data
Gasketed

14
7.1
1

Brass valve
Brass valve
a

6
590 304.2
1.1

56
46
5.5
2.289
73.3
580
162
100

Karamay 25#
Caltex or Shell/Viet
Nam

No
Nanjing Zhida
Electric Co., Ltd
24

Data
125
58
Porcelain
Non-Segregated
Phase
Busduct
31

Trench China
252
1050
460
460
Oil-paper ínsulation
4050
463
320
Al
31

460
50

460
50
200
30s

247
212
300
200

Data
1050
125
One unit

70

1155
75
950

N/A
Kalkulasi Performa Gas Turbine

P2/P1 = 15 Press. Ratio


k= 1.4 Sp. Ht. Rat.
cpo = 1.004 kJ/kg·K
R= 0.287 kJ/kg·K
mdot = 11 kg/s
nk = 0.85

STATE POINTS P [kPa] T [oC] T [K] v [m3/kg]


1 - Compressor In 100.00 20.00 293.15 0.8413
2 - Combustor In 1500.00 362.35 635.50 0.1216
3 - Turbine In 1500.00 1200.00 1473.15 0.2819
4 - Turbine Out 100.00 401.97 679.55 1.9503
5 - Compressor In 100.00 20.00 293.15 0.8413

Parameter Unjuk Kerja


PROCESSES hin [kJ/kg] hout [kJ/kg] Q [kW] W [kW]
Compressor 294.32 638.04 -3780.91
Combustor 638.04 1479.04 9251.01
Turbine 1479.04 682.27 8764.52
Low Temp HE 682.27 294.32 -4267.40

Efisiensi Unit
Efisiensi Thermal 32.95%
Efisiensi Kompresor 78.64%
Efisiensi Siklus 46.13%
Pv Diagram Brayton Cycle
1600.00

1400.00

1200.00

s [kJ/kg·K] 1000.00
Tekanan [kPa]

0.1000
800.00
0.0996
0.9437 600.00
0.9441
400.00
0.1000

200.00

0.00
0.0000 0.5000 1.0000 1.5000 2.0000 2.5000

Volume Spesifik [m3/kg]

Compres s or Combustor
Turbi ne Heat Exchanger

Ts Diagram Brayton Cycle


1400.00

1200.00

1000.00
Temperature [C]

800.00

600.00

400.00

200.00

0.00
0.0000 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000 0.9000 1.0000

Entropi [KJ/Kg.K]

Compres s or Combustor
Turbi ne Heat Exchanger
2 Combuster Chamber 3

Compressor Turbine

1 4
Heat Exchanger
2.0000 2.5000

nger

0.8000 0.9000 1.0000

nger
Turbine
Kalkulasi Kehandalan Gas Turbine Power Plan

Daya Terpasang Beban Min Beban Maks


Unit A 300 250 295

Pemakaian Bahan Bakar Nilai Satuan


Heat Rate 2500 Kcal/KWh
Nilai Kalor 5000 Kcal /Kg
SFC 0.5 Kg/KWh

Starting Unit Jumlah Periode


Start Failure 0 kali dlm 1 thn
Start Succed 1 kali dlm 1 thn
SFF 0.00 %

Jam Kinerja Unit Jumlah Satuan


Available Hours 7940 Jam
Service Hour 7000 Jam
Equivalent Seasonal Derated Hours 100 jam
Equvalent Maintenance Derated Hours 500 jam
Equivalent Forced Derated Hours 120 jam
Equivalent Planned Derated Hours 100 jam

Pembebanan Jumlah Satuan


Beban Rata-Rata 278.42 MW
Beban Puncak 295 MW
Faktor Pembebanan 94.38 %

Penggunaan Daya Jumlah Satuan


Beban Puncak 295 MW
Daya Terpasang 300 MW

Kapasitas Jumlah Satuan


Produksi Energi/Tahun 2,210,628 MWh
Daya Mampu/Tahun 2,628,000 MWh
Faktor Kapasitas 84.118 %

Data Finansial Tahunan Nilai Satuan


Harga Jual Ke PLN 1400 Rp/KWh
Laba Kotor 3,094,879,666,667 Rp/Tahun
Biaya Produksi 983 Rp/KWh
Laba Bersih 921,832,015,000 Rp/Tahun
Available Hour 7940 Jam
Equivalent Seasonal Derated Hours 100 Jam
Equvalent Maintenance Derated Hours 500 Jam
Equivalent Forced Derated Hours 60 Jam
Equivalent Planned Derated Hours 100 Jam
e Power Plant

Beban Maks Beban Avg. Satuan Waktu dalam 1 Tahun


295 278.42 MW 8760 Jam

Pembebanan Bulanan
Jan Feb Mar Apr Mei Jun Jul Aug Sep
268 270 255 269 290 295 295 287 287

Faktor Pembebanan Bulanan


Jan Feb Mar Apr Mei Jun Jul Aug Sep
90.85% 91.53% 86.44% 91.19% 98.31% 100.00% 100% 97.29% 97.29%

Faktor Ketersediaan
Jan Feb Mar Apr Mei Jun Jul Aug Sep
89.33% 90.00% 85.00% 89.67% 96.67% 98.33% 98% 95.67% 95.67%

Grafik Faktor Pembebanan dan Ketersediaan

120%

100%
Fa ktor Beba n Dan Keters edi a an (%)

80%

60%

40%

20%

0%
1 2 3 4 5 6 7 8 9 10

Bul a n

Summary Kehandalan Unit


Item Penjelasan
1 Realibility Tingkat seringnya unit mengalami gangguan
2 Availability Tingkat Ketersediaan / Kesiapan Unit
3 Capacity Faktor kapasitas daya listrik yang dapat dibangkitkan
4 Service Factor Faktor pelayanan ketika unit terhubung Grid
5 Load Factor Perbandingan besarnya beban rata-rata terhadap beban puncak
6 Starting Failure Persentase kegagalan penyalaan unit dalam setahun
7 Maintenance Faktor durasi gangguan keluaran unit untuk melakukan perawatan
8 Seasonal Outage Faktor durasi gangguan keluaran unit karena keadaan iklim/cuaca
9 Forced Outage Gangguan keluar paksa karena unit membutuhkan perbaikan mendadak
10 Planned Outage Faktor Durasi gangguan keluaran unit yang sudah direncanakan

Overall Status Pembangkit Unit A

0 1000 2000 3000 4000 5000 6000 7000 8000

Axis Title
Avg.
Okt Nov Des
255 275 295 278.42

Avg.
Okt Nov Des
86.44% 93.22% 100% 94.38%

Avg.
Okt Nov Des
85.00% 91.67% 98% 92.81%

an

Faktor
Pembebanan
Faktor
Ketersediaan

PLN
Standard

9 10 11 12

Status
Nilai Standar
EFOR 8.95% PLN 9% Baik
EAF 92.81% PLN 80% Baik
CF 84.12% PLN 60% Baik
SF 79.91% PLN 60% Baik
LF 94.38% PLN 60% Baik
SFF 0.00% Owner 30% Baik
MOF 5.71% Owner 10% Baik
SOF 1.14% Owner 5% Baik
FOF 1.37% Owner 5% Baik
POF 1.14% Owner 5% Baik

Layak Operasi

Equi va l ent Pl a nned Derated Hours


Equi va l ent Forced Derated Hours
Equva l ent Ma i ntena nce Derated Hours
Equi va l ent Seas ona l Derated Hours
Avai l a bl e Hour

7000 8000