RADWIN SETUP DETAILS FOR (2.4 & 5.8) GHz Antennas and Details of
Software Up-Gradation
4. Password: admin
Page 3 of 17
6. Set to Give Soft Loop from Radwin Modem towards MPLS Router
Go to Maintenance---Loop back
Page 4 of 17
To Give Loop from BTS End towards MPLS Router Select Line LOOP in the BTS End
site and None in the Customer END
Page 5 of 17
To Give Loop from Customer End towards MPLS Router Select Reverse LOOP in the
Customer End site and None in the BTS END
Select the END you want to check the Tx Power or to change the Tx Power
Site1: The END from where we are installing the Link(e.g-BTS End)
Site2: The END which is the Remote End(e.g-Customer End)
Then Click on the Change Password if the Link is installed for the first time or if it is
asking for the Password
Press OK and the Again one POP UP will appear asking for YES/NO . Select YES
Page 11 of 17
If the PASSWORD is loaded Successfully then the SCREEN will be appearing like this.
The LINK PASSWORD has been successfully UPDATED as shown and Click on OK
then Press NEXT
To change the Frequency Select other from the Drop Down Link and change the
Frequency
Then Click on Next to Continue
Then the following Screen will be Appearing Select the Tx Clock as Transparent and
press NEXT to Continue
Then this Screen will APPER Press Finish to Complete the Link Set up
The Defaul Laptop IP Address will remain the same and set the Default Gateway of
laptop as shown
Defaut Gateways=IP Address of the modem which we can get from the Management
Option in the Configuration as shown above
Please give the Default Gateway of the REMOTE END first and then after completion of
UPGRADATION of the Remote End give the Default Gateway of the Near End(from
the END where you are LOGGED in)
Browse the SwUpd file from the Radwin 1.750 CD or Download the PATCH from the
RADWIN Site (through internet)
http://www.radwin.com/winlink-1000/1.790/Manager.Zip
http://www.radwin.com/winlink-1000/1.790/SwUpd.exe
Page 15 of 17
Give the IP Address SAME as the Default Gateway and Click on Next