Bulletin 836T

Pressure Controls
Style T Pressure Controls - Copper Alloy Bellows

Style T— Type 1,4& 13 Style T— Type 1,4& 13


With Pilot Light Option With Pilot Light and 5-Pin Mini-Receptacle

Style T With Copper Alloy Bellows® — S.P.D.T. 2-Circuit Contact Block


Pressure Specifications Enclosure Type
Type 7 & 9 and
Adjustable Maximum psi Type 1, 4 & 13
Adjustable 4&136
Differential psi
Operating Range Occasional
(Approximate Line Catalog Catalog
psi Surge
Mid-Range Values) Pressure Number * Number *
Pressure @
30" Hg Vac. to 35 2 to 7 80 90 836T-T251J 836T-T251 E
6 to 75 3 to 15 200 220 836T-T252J 836T-T252E
12 to 150 6 to 30 350 450 836T-T253J 836T-T253E
20 to 300 10 to 55 600 750 836T-T254J 836T-T254E
40 to 450 20 to 90 900 1200 836T-T255J 836T-T255E
60 to 650 30 to 125 1300 1600 836T-T256J 836T-T256E

Style T With Copper Alloy Bellows0 — D.P.D.T. 4-Circuit Contact Block


Pressure Specifications Enclosure Type
Type 7 & 9 and
Adjustable Maximum psi Type 1, 4 & 13
Adjustable 4&130
Differential psi
Operating Range Occasional
(Approximate Line Catalog Catalog
psi Surge
Mid-Range Values) Pressure Number * Number *
Pressure ©
30" Hg Vac. to 35 2.2 to 7 80 90 836T-T251JX40 836T-T251EX40
6 to 75 4.5 to 15 200 220 836T-T252JX40 836T-T252EX40
12 to 150 9 to 30 350 450 836T-T253JX40 836T-T253EX40
20 to 300 15 to 55 600 750 836T-T254JX40 836T-T254EX40
40 to 450 30 to 90 900 1200 836T-T255JX40 836T-T255EX40
60 to 650 45 to 125 1300 1600 836T-T256JX40 836T-T256EX40

O Copper alloy bellows may be used on water or air, and other liquids or gases not corrosive to this alloy.
@ Transients (pulses) can occur in a system prior to reaching a steady-state condition. Surge pressures within published values generated
during start-up or shut-down of a machine or system, not exceeding 8 times in a 24 hour period, are negligible.
© The combined Type 7&9 and 4&13 Hazardous Gas and Dust service enclosure is supplied with special gasket and O-ring seal to
diminish/exclude moisture, fluids, and dust from entering the enclosure. Enclosures rated 7&9 only are not designed to restrict moisture from
entering the enclosure, which is common to outdoor service.

16-12 * Prices - Consult Sales Office or price list Allen-Bradley


Bulletin 836T
Pressure Controls
Technical Data

Mounting Without Removing Cover Temperature Range Contacts


Bulletin 836T controls can be mounted The temperature range at +32° F (0° C) or Bulletin 836T controls feature 2-circuit and
without removing the front cover. This below is based on the absence of freezing 4-circuit contact blocks for added control
helps prevent foreign materials from en- moisture, water, or other fluids that may circuit flexibility.
tering the opened enclosure during the in- solidify and impede the operation of the Two-circuit contact blocks have one nor-
terval between mounting and wiring of the control. Temperature ratings: mally open contact and one normally
control. closed contact and may be arranged for
Operating: -22°F to +150°F single pole double throw operation or sep-
Factory Set Pressure Controls (-30°C to +66°C) arate circuit operation having the same
Allen-Bradley will factory set pressure Storage: -22°F to +200°F polarity.
controls to customer specified values. See (-30 °C to +93 °C) Four-circuit contact blocks may be ar-
Factory Set Pressure Controls, page ranged for double pole double throw op-
16-25. eration or separate circuit operation hav-
ing the same polarity.

2-Circuit Contact Ratings — NEMA A600 (ICS 2-125)


AC DC
Maximum Amperes Continuous Voltamperes Maximum Ampere
AC Voltage Make Break Carrying Current Make Break Voltage
120 60 6.00 10 7200 720 115-125 0.4
240 30 3.00 10 7200 720 230-250 0.2
480 15 1.50 10 7200 720 550-600 0.1
600 12 1.20 10 7200 720 —

IEC 337-1

Maximum Maximum Rated Operational Current


Operational Utilization Continuous Make Break
Category Volts
Voltage Ue Current Ith
10
Ue
120-600 AC
-3E^
7200VA
-3E-
720VA
AC600 AC-11 10 72-1 20 AC 60A 720VA
10 24-72 AC 60A 10A
DC600 DC-11 — 11 5-600 DC 50VA 50VA

4-Circuit Contact Ratings — NEMA B150 (ICS 2-125)


AC DC
Maximum Amperes Continuous Carrying Voltamperes Maximum
Ampere
AC Voltage Make Break Current Make Break Voltage
120 30 3.00 5 3600 360 115-120 0.33
240 27.5 2.80 5 6600 660 230-240 0.17

IEC 337-1
Maximum Maximum Rated Operational Current
Operational Utilization Continuous Make Break
Category Volts
Voltage Ue Current Ith
5
Ue
72- 120 AC
-3E-30A
^3t>
360VA
AC150 AC-11
5 24-72 AC 30A 5A
DC150 DC-11 — 11 5-240 DC 40VA 40VA

Note: NEMA does not rate contacts to switch low voltage and current. Bulletin 836T Style T and D Pressure Controls are supplied
with silver contacts. The devices are designed to deliver high force snap action to the contacts. This provides exceptional contact
fidelity at 24V DC I/O card current level entry when the integrity of the enclosure is maintained.

Allen-Bradley
16-8
Bulletin 836T
Pressure Controls
Ordering Information

Ordering Bulletin 836T Pressure Controls


When ordering Bulletin 836T Pressure Controls, consider the following:
• Device Style • Occasional Surge Pressure
• Adjustable Operating Range • Pressure Media
• Adjustable Differential • Enclosure Type
• Maximum Line Pressure • Pressure Connection

How to Order
Step 1: Basic Device —
Select a catalog number for the basic device See pages 16-12 thru 16-17.
Step 2: Modifications —
If required, add the appropriate modification
suffix code(s) to the catalog number of the basic device. . See pages 16-18 and 16-19.
Step 3: Accessories —
If required, select appropriate accessories Seepage 16-23.
Step 4: Factory Options —
Factory Set Pressure Controls See page 16-25.

Catalog Number Explanation (Example)


Note: Catalog number must not include blank spaces.

836T- T 25 1 J X40 X15

Bulletin Number Modification to basic operator


selected from Modifications table.
Add suffix codes in descending order.
(Optional. See pages 16-18 and 16-19.'

Style of Device:
T= Pressure Control
D= Pressure Difference Control Contact Block Type:
2-Circuit Contact Block (Standard)
4-Circuit Contact Block (when X40 is specified)

Operator Type:
Copper Alloy Bellows Letter-Enclosure Type:
Type 316 Stainless Steel Bellows J = 1, 4 & 13 Industrial Use
Piston With or Without Seal E = 7 & 9 a n d 4 & 1 3 Combined
Hazardous Locations

Pressure Specifications:
Adjustable Operating Range
Adjustable Differential
Maximum/Minimum Line Pressure
Max. Occasional Surge Pressure
See SpecificationsTables

Allen-Bradley 16-11
Bulletin 836T
Pressure Controls
Technical Data

Pressure Control Selection


The selection table below is an overview of the five types of Bulletin 836T Pressure Controls Allen-Bradley offers. Each type of control
is suitable for use on many types of applications. Pressure ranges, pressure connections, enclosure types and the compatibility of
the actuator with different types of pressure media are given to assist in the selection of which type of control to use.

Bulletin Number 836T 836T 836T 836T


Type 31 6 Stainless Piston Type Without Piston Type
Actuator Type Copper Alloy Bellows
Steel Bellows Seal With Seal
30" Hg Vac. to 30" Hg Vac. to
Adjustable Operating Ranges 40 to 5000 psi 80 to 5000 psi
650 psi 375 psi
Adjustable Differentials 2 to 125 psi 2 to 90 psi 20 to 650 psi 40 to 650 psi
Maximum Line Pressures 1300 psi 600 psi — —
Occasional Surge Pressures 1600 psi 600 psi 15,000 psi 15, 000 psi
Pressure Media
Air
• •
Water
• •
Hydraulic Fluids
• • • •
Liquids:
Corrosive O •
Non-Corrosive
• •
Gases:
Corrosive O •
Non-Corrosive
• •
Enclosures
Type1,4& 13
• • • •
Type? & 9 and 4 & 13
• • • •
Pipe Connections
1/4" N. RTF. Female 3/8" N.P.T.F. Female 3/8" N.P.T.F. Female
Pipe Thread Pipe Thread Pipe Thread
SAE 7/1 6-20 UNF-2B SAE 7/1 6-20 UNF-2B SAE 7/1 6-20 UNF-2B
Thread O-ring 1/4" N.P.T.F. Female Thread O-ring Thread O-ring
Standard Pressure Connection
Boss Seal Pipe Thread Boss Seal Boss Seal
SAE9/16-18UNF-2B SAE9/16-18UNF-2B SAE9/16-18UNF-2B
Thread O-ring Thread O-ring Thread O-ring
Boss Seal Boss Seal Boss Seal

O Corrosive liquids and gases must be compatible with Type 316 Stainless Steel Bellows.

Note: Pressure Difference Controls are supplied with either copper alloy or stainless steel bellows. See Ordering Information on page
16-11 for details.

16-10 Allen-Bradley
Bulletin 836T
Pressure Controls
Modifications

Ordering Modifications
Modifications are ordered by adding the appropriate modification suffix code to the catalog number of the basic device. Add suffix
codes to the catalog number in descending order.

Modifications
Item Description Suffix Code #

Metric Electrical Entry BS 20mm thread. S60


Conduit Hub Pg 13.5 thread. S70
Bellows and fittings specially prepared for oxygen and nitrous oxide ser-
Oxygen / Nitrous Oxide vice. Devices tested with pure oxygen, bellows plugged for protection X2
Service from contamination, and warning tag applied to avert contamination.
Range and differential adjustments are factory sealed. Price includes
Tamper Resistant Setting X4
factory setting charge.
SAE 7/16-20 UNF Thread Female SAE straight thread O-ring seal designed to prevent leaks and
O-ring Boss Seal minimize loss of hydraulic fluids. Not available on stainless steel X16
(Bellows Type Pressure
bellows.
Control)
SAE 9/16-18 UNF Thread Female SAE straight thread O-ring seal designed to prevent leaks and
O-ring Boss Seal minimize loss of hydraulic fluids. Not available on stainless steel X17
(Bellows Type Pressure bellows.
Control)
SAE 7/16-20 UNF Thread Female SAE straight thread O-ring seal designed to prevent leaks and
O-ring Boss Seal minimize loss of hydraulic fluids. Use on applications with a pressure
X6
(Piston Type Pressure range of 1000 to 5000 psi. Not available on Catalog Numbers
Control) 836T-T300J or 836T-T350J.
SAE 9/16-18 UNF Thread Female SAE straight thread O-ring seal designed to prevent leaks and
O-ring Boss Seal minimize loss of hydraulic fluids. Use on applications with a pressure X7
(Piston Type Pressure
range of 550 to 5000 psi.
Control)
A high intensity neon pilot light for 120V AC, 60 Hz applications is avail-
Neon Pilot Light 120V AC able and can be wired for ON or OFF operation. The current rating is X9
1 .OmA. Not available on Type 7 & 9 enclosed devices.
A high intensity LED 24V DC pilot light is available to meet the require-
LED Pilot Light 24V DC ments of the automotive, machine tool builders and other industries. The
X15
current rating is 22mA and can be wired for ON or OFF operation. Not
available on Type 7 & 9 enclosed devices.
Special Diaphragm
Diaphragm is made of Viton® and Nomex fabric. Required when phos-
Assembly
phate ester base and other adverse hydraulic fluids are present. Use on X25
(Piston Type Pressure
Catalog Number 836T-T300 through 836T-T303 series controls.
Control)
Special Diaphragm and Diaphragm is made of Viton® and Nomex fabric, O-ring is made of
O-ring Assembly Viton®. Required when phosphate ester base and other adverse hy-
X26
(Piston Type Pressure draulic fluids are present. Use on Catalog Number 836T-T350, -T351,
Control) -T352, -T353 and -T400 series controls.
Operator Indicator for Viewed through a window in the cover. Indicates when operation of the
X28
Piston Type Controls control occurs. Standard feature on Bulletin 836T bellows controls.
Special enclosure gaskets made of Viton® are available for applications
where the standard gasket materials are not fluid compatible. Viton® is
Viton® Enclosure Gaskets generally specified by the user for use with existing and newly developed X29
coolants and hydraulic fluids to maintain enclosure integrity.
Note: Viton® enclosure gaskets are often used with Special Diaphragm
Assemblies (X25 or X26). See description above.

<s> Registered DuPont Trademark.

16-18 * Prices - Consult Sales Office or price list Allen-Bradley


Bulletin 836T
Pressure Controls
Modifications

Ordering Modifications (cont'd)


Modifications are ordered by adding the appropriate modification suffix code to the catalog number of the basic device. Add suffix
codes to the catalog number in descending order.

Modifications
Item Description Suffix Code
*
5-Pin Mini-Type
Select the desired pin wiring configuration from the diagrams on See pages 16-20 thru 16-22.
Receptacle No
pages 16-20 thru 16-22. Rated at 8A 600V.
Pilot Light
5-Pin Mini-Type Select the desired pin wiring, pilot light wiring, and voltage from the
Receptacle With diagrams on pages 1 6-20 thru 1 6-22. Includes receptacle and pilot See pages 16-20 thru 16-22.
Prewired Pilot Light light. Rated at 8A 600V.
Select desired pin wiring configuration from the diagrams on pages
1 6-20 thru 1 6-22. Add number "1 " to the Suffix Number immediate-
5-Pin
ly following the letter "X". Example: "X19" becomes "X119".
Micro-Connect
Rated at 3A 300V. See pages 16-20 thru 16-22.
Receptacle Without
Pin/Wiring Code: 1 - Red with White Tracer, 2 - Red,
Pilot Light
3 - Green (Gnd), 4 - Red with Yellow Tracer, 5 - Red with Black
Tracer.
Select the desired pin wiring configuration and pilot light (X9 or
X15, see above for specifications) from the diagrams on pages
5-Pin 1 6-20 thru 1 6-22. Add number "1 " to the Suffix Number immediate-
Micro-Connect ly after the first letter "X". Example: "X21 X9" becomes "X121 X9".
See pages 16-20 thru 16-22.
Receptacle With Rated at 3A 300V.
Prewired Pilot Light Pin/Wiring Code: 1 - Red with White Tracer, 2 - Red,
3 - Green (Gnd), 4 - Red with Yellow Tracer, 5 - Red with Black
Tracer.
Additional Optional
Receptacles and Consult your nearest Allen-Bradley sales office for assistance.
Wiring

Cross Reference Table - Wiring Diagram/Suffix Code (See pages 16-20 thru 16-22)
Pilot Light Contact Reference Bulletin
Receptacle Wiring Suffix Pilot Light Suffix
Configuration 802M Wiring
X19 None None J1
X20 None None J9
X21 X9O© N.C. J1
X21 X15®€> N.C. J1
X22 X9O© N.O. J1
X22 X15©© N.O. J1
X23 X90© N.C. J9
X23 X150© N.C. J9
X24 X9O© N.O. J9
X24 X150© N.O. J9
X81 X9O None None
X81 X15© None None

O 120V AC neon glow pilot light, current rating is 1.0 milliamps, nominal.
© 24V DC LED pilot light, current rating is 22 milliamps, nominal.
© In the diagrams shown on pages 16-20 thru 16-22, the pilot lights are wired across the terminals and in series with the load. Pilot light is "OFF"
when the load is energized, "ON" when the load is de-energized. For simultaneous energization of the load and pilot light, or other optional
wiring configurations, consult your nearest Allen-Bradley Sales Office.
O Bulletin 836T Suffix "X81" Wiring - Load and pilot light simultaneously energize when contacts displace (contact terminals 3 and 4 close) at a
predetermined pressure setting.

Allen-Bradley # Prices - Consult Sales Office or price list 16-19


Bulletin 836T
Pressure Controls
Dimension Drawings

Approximate Dimensions and Shipping Weights


Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
3.5 2
•<
Type 4 & 13 (88.9) ' (63 .5) -*
3.5 ^ . 2.78 .
2.72 >~ 1.16
(2) (88.9)
(69.1) (29.4 -

c
(70.6)
0.27 Dia.
(6.7)
-+ 2.72
(69.1)
^- 2.5 ,.
~ (63.5)
co\ 'A
i

Mtg. Holes
X
^L- > *
ri i 0.53 Dia.
(13.5) f
CTBR.
r \\
272
<
\5
• \
n yi ;
r~ <s>
(69.1) 0.54 D a. 2.72 I 72 0.86 I
(13.5
. |CTBF
3,
•. t (69.1)
( J3.7) (21-8) t
i •
? uA-*3-
OT r ~\, I1 (?)
V2-14 /" ^
N.P.T.F. V4-18
N.P.T.F.
20mm
Pg13.5 ft
V2-14
/ I
1.72 0.86
N.P.T.F.
20mm \ \ Y
(43.7) (21.8)

Approximate Shipping Weight 3-1/2 Ibs. (1.6 kg)


Pg 13.5
^
/4-18
%>.T.F.
Approximate Shipping Weight 4 Ibs. (1.8 kg)

Catalog A Catalog A A Catalog A


Number Catalog Number Dimensions Number Dimensions
Number Dimensions Dimensions
836T-T251J 6.75 836T-T254J 7 8.63 8.63
(171) 836T-T255J (178)
836T-D450J (219) 836T-D460J
836T-T260J (219)
7.19
836T-T250J 836T-T256J
6.5 (183) 836T-D451J 8.31 8.5
836T-T251J 836T-D462J
(165) 7.38 836T-D452J (211) (216)
836T-T252J 836T-T262J
836T-T253J (187)
836T-T261J 7.31 9.5 10.06
836T-T263J 836T-D453J 836T-D463J
(186) (241) (256)

3.5 4 2.78 „ Bellows and Piston Type


(2) -*
(88.9) (70.6)
0.27Dia.
2.72 , 2.5 _, 6.38
(6.7) (63.5)
Mtg. -(69.1) ' (162.1)
Holes »mJ e^£
n
s

I
sT
* ^
2.72
(69.1) 0.53 Dia
(13.5)
1 ' CTBR. 8 63
•• (178)
(219.2)
V2-14
N.P.T.F. ,1 ^ Drain
20mm
Pg13.5 T ^ 1
/8-27
N.P.T.F.
T] CC :,
.44 Dia.
(11.2)0
Mtg. Holes ± rrn

3
/8-1 8
J ! I I j Qty.2
SL\ . / ,l.
(9.5 )
N.P.T F.
1.7 2 T I tiT 1.38
(3 i.1)
N
>-
E3i-^
0.86 .50 -*. k t
(43 7) (21.8) ' .84
(12.7)
(71 1)
2.80 4.69
Approximate Shipping Weight 3-1/2 Ibs. (1.6 kg) ; - 5, 5
(141 .0)
(21.3) —-
Typ.
(119.1)
_ 1.69
(42.9)
2.69
(68.3)
V-14N.P.T. .-.Si
Conduit Connection -_^
i
Catalog Number
t
jf ITffl SM\
P
836T-T300J 836T-T350J .88 ———^-i—j— -_J
V8"-27 N.P.T. -
836T-T301J 836T-T351J (22.4) r
•69 Oil Drain Connection ©i
836T-T302J 836T-T352J (17.5) Plugged When " :
// r©i
"
836T-T303J 836T-T353J Not in Use V'-18 N.P.T.F
836T-T400J
Approximate Shipping Weight 9 Ibs. (4.0 kg)

16-26 Allen-Bradley
Bulletin 836T
Pressure Controls
Technical Data

Control Setting — Style T Pressure Controls


Allen-Bradley controls are designed for ease of setting to help minimize installation time. Standard pressure controls shipped from
the factory are set at the maximum operating range and minimum differential. By using a pressure gauge and following these simple
directions, the control can be set to the specific requirements for each application. See Figure 5.
STEP 1 - Adjust Trip Setting Figure 5
The trip setting is controlled by the operat- Trip and Reset Adjustment for Pressure Controls
ing range adjustment screw and is ad-
justed externally. After loosening the lock Operating Range
nut, the trip setting is set by turning the op- Adjustment Screw
erating range adjustment screw counter- (Trip Pressure)
clockwise to lower the trip setting or clock-
wise to raise the trip setting. The approxi-
mate trip setting is shown on the indicating Locking Nut
scale. When the proper setting is reached,
simply tighten the lock nut.
Note: Turning the operating range adjust- Finger-Safe Contact Block Shield
ment screw will cause both the trip and re- Meets IEC529/IP2X&CSA
set settings to change in equal incre-
ments.
Differential Adjustment Screw
STEP 2 - Adjust Reset Setting
(Reset Pressure)
The reset setting is controlled by an inter-
nal differential adjustment screw. After re-
moving the front cover, the reset setting is
set by turning the differential adjustment
screw clockwise to increase the differen-
tial or counterclockwise to decrease the
differential.
Note: Adjusting the differential does not
affect the trip setting.

Indicating Scale
(Approximate Trip Setting)

UL CSA
File Number Guide Number File Number Class
Bulletin 836T E 14842 NKPZ LR1234 3211-03
E53048 (Haz. Loc.) NOWT LR1 1924 (Haz. Loc.) 3218-05
Hazardous Location Enclosure not CE compliant.

Allen-Bradley 16-5
Bulletin 836T
Pressure Controls
Product Overview

Description
Bulletin 836T Pressure Controls are con- friction-free mechanism provides consis- Bulletin 836T Pressure Controls are of-
trol circuit devices designed to meet the tent operation regardless of mounting fered in a variety of styles to fit a wide
traditional requirements of the transporta- position. Devices are designed to allow range of applications. The devices are
tion, machine tool, and other heavy duty easy adjustment of pressure settings. available with either a Type 1, 4 & 13, or
industries. Allen-Bradley Bulletin 836T 7 & 9 and 4 & 13 combined enclosure.
Pressure Controls can be used in pneu- Allen-Bradley Bulletin 836T Pressure They are available with 2-circuit or 4-cir-
matic and hydraulic applications. The dia- Controls are used in many types of ap- cuit contact blocks. Accessories and mod-
phragm and copper alloy bellows actua- plications with adjustable ranges from 30 ifications are available to tailor the devices
tors can be used with air, water, oil, vapor inches mercury vacuum to 5000 psi. They to meet most application requirements.
and other non-corrosive gases and liq- can be used to control pneumatic sys-
uids. Type 316 stainless steel bellows are tems, to maintain a pressure tank within a Applications
available for the more corrosive gases, va- preset and constant pressure range. They • Machine Tools
pors, and fluids. A rugged cast iron cylin- can be used to detect over-pressures of
der and hardened steel piston assembly is gases and liquids to prevent damage to • Machine Hydraulic Pressures
used for the higher pressure coolant and valuable equipment. Pressure controls • Material Clamping Fixtures
hydraulic oil applications. The controls can also detect low pressure to protect
equipment from loss of coolants and lu- • Lubricant and Coolant Pressures
feature snap action precision switches
equipped with silver contacts. A relatively brication. • Compactor Ram Pressures
• Air Compressors

Style T — Pressure Controls Style D — Pressure Difference Controls

Style T Style D
• Independently Adjustable Operating Range • Independently Adjustable System Difference Range
and Differential and Differential
• Single bellows or piston operation • Two bellows operation, one bellows connected to each system
Copper Alloy Bellows Copper Alloy Bellows
• 1/4" N.P.T.F. female pipe connection • 1/4" N.P.T.F. female pipe connection
• SAE 7/16-20 UNF-2B Thread O-ring Boss Seal • Adjustable System Difference Range - 1 to 70 psi
• SAE 9/16-18 UNF-2B Thread O-ring Boss Seal • Maximum Line Pressure - 600 psi
• Adjustable Operating Range - 30" Hg Vac. to 650 psi • Occasional Surge Pressure - 650 psi
• Maximum Line Pressure - 1300 psi
• Occasional Surge Pressure - 1600 psi
Type 316 Stainless Steel Bellows Type 316 Stainless Steel Bellows
• 1/4" N.P.T.F. female pipe connection • 1/4" N.P.T.F. female pipe connection
• Adjustable Operating Range - 30" Hg Vac. to 375 psi • Adjustable System Difference Range - 1 to 70 psi
• Maximum Line Pressure - 600 psi • Maximum Line Pressure - 500 psi
• Occasional Surge Pressure - 600 psi • Occasional Surge Pressure - 500 psi
Piston
• 3/8" N.P.T.F. female pipe connection
• SAE 7/16-20 UNF-2B Thread O-ring Boss Seal
• SAE 9/16-18 UNF-2B Thread O-ring Boss Seal
• Adjustable Operating Range - 40 to 5000 psi
• Occasional Surge Pressure - 15,000 psi

16-2 Allen-Bradley
NEMA Enclosures
Important

Specify the Correct Enclosure


for your Motor Controls
Type 1 Type 3R
General Purpose Rainproof
Surface Mounting

Type 1 enclosures are intended for indoor use primarily to provide a Type 3R enclosures are intended for outdoor use primarily to provide
degree of protection against contact with the enclosed equipment in a degree of protection against falling rain, and to be undamaged by
locations where unusual service conditions do not exist. The the formation of ice on the enclosure. They are designed to meet rod
enclosures are designed to meet the rod entry and rust-resistance entry, rain ➌, external icing ➋, and rust-resistance design tests. They
design tests. Enclosure is sheet steel, treated to resist corrosion. are not intended to provide protection against conditions such as dust,
internal condensation, or internal icing.
Type 1 Type 4
Flush Mounting Watertight
Stainless Steel

Type 4 enclosures are intended for indoor or outdoor use primarily


to provide a degree of protection against windblown dust and rain,
Type 1 Flush mounting enclosures for installation in machine frames splashing water, and hose-directed water; and to be undamaged by
and plaster wall. These enclosures are for similar applications and are the formation of ice on the enclosure. They are designed to meet
designed to meet the same tests as Type 1 surface mounting. hosedown, dust, and external icing tests ➋. They are not intended to
provide protection against conditions such as internal condensation
or internal icing.
Type 3 Type 4X
Rainproof Dusttight Non-Metallic,
Corrosion-Resistant
Type 3 enclosures are intended for outdoor use primarily to provide
a degree of protection against windblown dust, rain and sleet; and to
be undamaged by the formation of ice on the enclosure. They are
designed to meet rain ➊, external icing ➋, dust, and rust-resistance
design tests. They are not intended to provide protection against
conditions such as internal condensation or internal icing.

Type 4X enclosures are intended for indoor or outdoor use


primarily to provide a degree of protection against corrosion,
windblown dust and rain, splashing water, and hose-directed
water; and to be undamaged by the formation of ice on the
enclosure. They are designed to meet the hosedown, dust,
external icing ➋, and corrosion-resistance design tests. They are
not intended to provide protection against conditions such as
internal condensation or internal icing.

➊ Evaluation criteria: No water has entered enclosure during specified test.


➋ Evaluation criteria: Undamaged after ice buildup during specified test has melted (Note: Not required to be operable while ice-laden).
➌ Evaluation criteria: No water shall have reached live parts, insulation or mechanisms.

Important-8
NEMA Enclosures

ENCLOSURES
Refer to the brief descriptions below for the various types of enclosures NOTE: Enclosures do not normally protect devices against
offered by Allen-Bradley. See pages Important-11 and Important-12 conditions such as condensation, icing, corrosion or
for selection criteria. For definitions, descriptions and test criteria, contamination that may occur within the enclosure or enter via
see National Electrical Manufacturers Association (NEMA) Standards the conduit or unsealed openings. Users must make adequate
Publication No. 250. Also see individual product listings within the provisions to safeguard against such conditions and satisfy
Allen-Bradley catalog for available enclosure types and for any themselves that the equipment is properly protected.
additional information relating to these descriptions.

Type 6P
For Prolonged Submersion at a Limited Depth

Type 6P enclosures are intended for indoor or outdoor use


primarily to provide a degree of protection against the entry of
water during prolonged submersion at a limited depth; and to be
undamaged by the formation of ice on the enclosure. They are
designed to meet air pressure, external icing ➊, hosedown and
corrosion-resistance design tests. They are not intended to
provide protection against conditions such as internal
Type 7 & 9 Bolted Enclosure Type 7 & 9 Unilock Enclosure
for Hazardous Locations for Hazardous Locations condensation or internal icing.

Type 7 Type 12
For Hazardous Dusttight
Gas Locations Industrial Use

Type 7 enclosures are for indoor use in locations classified as


Class I, Groups C or D, as defined in the U.S. National Electrical
Code. Type 7 enclosures are designed to be capable of
withstanding the pressures resulting from an internal explosion of
specified gases, and contain such an explosion sufficiently that Type 12 enclosures are intended for indoor use primarily to
an explosive gas-air mixture existing in the atmosphere provide a degree of protection against dust, falling dirt, and
surrounding the enclosure will not be ignited. Enclosed heat dripping non-corrosive liquids. They are designed to meet drip ➋,
generating devices are designed not to cause external surfaces dust, and rust-resistance tests. They are not intended to provide
to reach temperatures capable of igniting explosive gas-air protection against conditions such as internal condensation.
mixtures in the surrounding atmosphere. Enclosures are
designed to meet explosion, hydrostatic, and temperature design
tests. Finish is a special corrosion-resistant, gray enamel. Type 13
Oiltight
Type 13 enclosures are intended for indoor use primarily to
Type 9 provide a degree of protection against dust, spraying of water, oil,
For Hazardous and noncorrosive coolant. They are designed to meet oil exclusion
Dust Locations and rust-resistance design tests. They are not intended to provide
protection against conditions such as internal condensation.
Type 9 enclosures are intended for indoor use in locations
classified as Class II, Groups E, F, or G, as defined in the U.S.
National Electrical Code. Type 9 enclosures are designed to be
capable of preventing the entrance of dust. Enclosed heat
generating devices are designed not to cause external surfaces
to reach temperatures capable of igniting or discoloring dust on
the enclosure or igniting dust-air mixtures in the surrounding
atmosphere. Enclosures are designed to meet dust penetration
and temperature design tests, and aging of gaskets. The outside
finish is a special corrosion-resistant gray enamel.

➊ Evaluation criteria: Undamaged after ice buildup during specified test has melted (Note: Not required to be operable while ice-laden).
➋ Evaluation criteria: No water has entered enclosure during specified test.

Continued on next page.

Important-9

Anda mungkin juga menyukai