Anda di halaman 1dari 80

CALCULO DE FACTOR DE CHRISTIANSEN (Fn)

n =SUMA(n^1.852) n^2,852 F(n)=sum(n^1,852)/n^2,852


0 0 0 0
1 1.000 1 1
2 4.610 7.220 0.639
3 12.259 22.948 0.534
4 25.292 52.128 0.485
5 44.993 98.506 0.457
6 72.607 165.687 0.438
7 109.346 257.170 0.425
8 156.392 376.368 0.416
9 214.905 526.623 0.408
10 286.027 711.214 0.402
11 370.878 933.366 0.397
12 470.566 1196.258 0.393
13 586.184 1503.026 0.390
14 718.810 1856.766 0.387
15 869.512 2260.540 0.385
16 1039.349 2717.379 0.382
17 1229.365 3230.281 0.381
18 1440.600 3802.219 0.379
19 1674.081 4436.140 0.377
20 1930.829 5134.966 0.376
21 2211.857 5901.595 0.375
22 2518.171 6738.907 0.374
23 2850.770 7649.760 0.373
24 3210.644 8636.991 0.372
25 3598.781 9703.422 0.371
26 4016.160 10851.855 0.370
27 4463.756 12085.078 0.369
28 4942.536 13405.861 0.369
29 5453.466 14816.959 0.368
30 5997.503 16321.115 0.367
31 6575.602 17921.0541 0.367
32 7188.711 19619.491 0.366
33 7837.775 21419.127 0.366
34 8523.735 23322.649 0.365
35 9247.528 25332.734 0.365
36 10010.085 27452.047 0.365
37 10812.334 29683.241 0.364
38 11655.202 32028.959 0.364
39 12539.608 34491.832 0.364
40 13466.470 37074.482 0.363
41 14436.702 39779.522 0.363
42 15451.215 42609.553 0.363
43 16510.917 45567.168 0.362
44 17616.711 48654.950 0.362
45 18769.499 51875.475 0.362
46 19970.180 55231.309 0.362
47 21219.648 58725.009 0.361
48 22518.797 62359.124 0.361
49 23868.515 66136.197 0.361
50 25269.690 70058.761 0.361
51 26723.207 74129.341 0.360
52 28229.946 78350.457 0.360
53 29790.788 82724.620 0.360
54 31406.609 87254.333 0.360
55 33078.284 91942.094 0.360
56 34806.683 96790.393 0.360
57 36592.678 101801.714 0.359
58 38437.136 106978.533 0.359
59 40340.921 112323.321 0.359
60 42304.897 117838.544 0.359
61 44329.924 123526.657 0.359
62 46416.861 129390.115 0.359
63 48566.565 135431.362 0.359
64 50779.891 141652.840 0.358
65 53057.691 148056.982 0.358
66 55400.815 154646.218 0.358
67 57810.113 161422.971 0.358
68 60286.432 168389.660 0.358
69 62830.616 175548.696 0.358
70 65443.509 182902.487 0.358
71 68125.951 190453.435 0.358
72 70878.784 198203.938 0.358
73 73702.844 206156.388 0.358
74 76598.968 214313.172 0.357
75 79567.990 222676.673 0.357
76 82610.744 231249.267 0.357
77 85728.060 240033.329 0.357
78 88920.768 249031.226 0.357
79 92189.696 258245.323 0.357
80 95535.671 267677.978 0.357
81 98959.517 277331.547 0.357
82 102462.058 287208.380 0.357
83 106044.116 297310.823 0.357
84 109706.512 307641.219 0.357
85 113450.063 318201.906 0.357
86 117275.589 328995.216 0.356
87 121183.905 340023.480 0.356
88 125175.826 351289.024 0.356
89 129252.165 362794.170 0.356
90 133413.734 374541.234 0.356
91 137661.344 386532.531 0.356
92 141995.805 398770.372 0.356
93 146417.924 411257.063 0.356
94 150928.508 423994.906 0.356
95 155528.363 436986.200 0.356
96 160218.292 450233.242 0.356
97 164999.100 463738.322 0.356
98 169871.587 477503.729 0.356
99 174836.554 491531.749 0.356
100 179894.800 505824.662 0.356
101 185047.125 520384.746 0.356
102 190294.323 535214.277 0.356
103 195637.193 550315.525 0.356
103 200980.062 550315.525 0.365
105 206516.655 581342.242 0.355
106 212151.298 597272.237 0.355
107 217884.784 613483.002 0.355
108 223717.903 629976.792 0.355
109 229651.443 646755.860 0.355
110 235686.192 663822.453 0.355
111 241822.938 681178.819 0.355
112 248062.467 698827.200 0.355
113 254405.563 716769.836 0.355
114 260853.010 735008.965 0.355
115 267405.591 753546.819 0.355
116 274064.088 772385.630 0.355
117 280829.281 791527.627 0.355
118 287701.951 810975.034 0.355
119 294682.876 830730.076 0.355
120 301772.834 850794.970 0.355
121 308972.602 871171.935 0.355
122 316282.956 891863.185 0.355
123 323704.671 912870.931 0.355
124 331238.521 934197.382 0.355
125 338885.279 955844.746 0.355
126 346645.717 977815.224 0.355
127 354520.607 1000111.019 0.354
128 362510.719 1022734.328 0.354
129 370616.822 1045687.349 0.354
130 378839.686 1068972.273 0.354
SISTEMA DE RIEGO POR GOTEO

CUADRO No.1: CALCULO DE HF SEGÚN HAZEN & WILLIAMS

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM


A CABEZAL
A-B 36.00 150 133

HIDRAULICA DE TUBERIAS
CUADRO No.2: CALCULO DE DIAMETRO SEGÚN CAUDAL Y VELOCIDAD
CAUDAL-M3/HR Q-LPS VELOCIDAD-M/S DIAM. INT-MM DIAM.INT REAL
3.50 0.97 1.5 28.73 28.80
9.00 2.50 1.5 46.07 46.20
15.00 4.17 1.5 59.47 59.80
21.00 5.83 1.5 70.37 71.20
31.00 8.61 1.5 85.49 85.60
46.00 12.78 1.5 104.14 104.60
75.00 20.83 1.5 132.98 133.00
98.00 27.22 1.5 152.01 152.00
154.00 42.78 1.5 190.55 190.20
240.00 66.67 1.5 237.88 237.60
380.00 105.56 1.5 299.33 299.60
MODELO

C F VEL(M/S) HFRICCION-M

150 1 0.72

DIA NOM-C5
32
50
63
75
90
110
140
160
200
250
315
CALCULO HIDRAULICO TUBERIA DISTRIBUIDORA DE DOS DIAMETROS

Q q
QT-D d
A B C
LAB LBC
----- LT -----

LOTE
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 33.41 64.309 104.6 36 150 0.365 1.1 0.24


A-B 3.22
B-C 31.74 61.09355 104.6 34 150 0.366 1.0 0.21
b-c 31.74 61.09355 104.6 34 150 0.366 1.0 0.21
HF TOTAL 0.24
TOPO = -1.28

1 B-C A-B
LONGITUD 61.09 3.22
CAUDAL 31.74 1.67

LOTE
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.60 99.00 85.6 55 150 0.36 1.4 0.73


A-B 86.13
B-C 3.72 12.87 85.6 7 150 0.426 0.2 0.00
b-c 3.72 12.87 46.2 7 150 0.426 0.6 0.05
HF TOTAL 0.78
TOPO = -0.50

1/8 B-C A-B


LONGITUD 12.87 86.13
CAUDAL 3.72 24.88

LOTE 20

PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 37.76 130.5 85.6 73 150 0.358 1.8 1.59


A-B 62.5
B-C 19.68 68 85.6 38 150 0.364 0.9 0.25
b-c 19.68 68 71.2 38 150 0.364 1.4 0.62
HF TOTAL 1.96
-1.85

LOTE 20

384494708.xls04/18/201880
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 37.76 130.5 104.6 72.5 150 0.358 1.2 0.60


A-B 23.49
B-C 30.96 107.01 104.6 59.45 150 0.359 1.0 0.34
b-c 30.96 107.01 85.6 59.45 150 0.359 1.5 0.91
HF TOTAL 1.17
TOPO = -1.85

0.18 A-B B-C


LONGITUD 23.49 107.01
CAUDAL 6.7968 30.96

LOTE 7

PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.60 99 85.6 55 150 0.36 1.4 0.73


A-B 7.94 27.5
B-C 20.66 71.5 85.6 40 150 0.363 1.0 0.29
b-c 20.66 71.5 71.2 40 150 0.363 1.4 0.71
HF TOTAL 1.15
-1.15

LOTE 7
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.60 99 85.6 55 150 0.36 1.4 0.73


A-B 27.72
B-C 20.59 71.28 85.6 40 150 0.363 1.0 0.29
b-c 20.59 71.28 71.2 40 150 0.363 1.4 0.70
HF TOTAL 1.14
TOPO = -1.15

5/7 B-C A-B


LONGITUD 71.28 27.72
CAUDAL 20.59 8.01

384494708.xls04/18/201880
Q-GOTERO 0.4 lph
Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 64.309 m
Area/Valvula 0.84 has
Q/valvula 18.58 m3/hr

33.41

Q-GOTERO 0.4 lph


Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 99 m
Area/Valvula 1.29 has
Q/valvula 28.60 m3/hr

Q-GOTERO 0.4 lph


Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 130.5 m
Area/Valvula 1.70 has
Q/valvula 37.70 m3/hr

37.76

384494708.xls04/18/201880
Q-GOTERO 0.4 lph
Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 130.5 m
Area/Valvula 1.70 has
Q/valvula 37.70 m3/hr

37.76

Q-GOTERO 0.4 lph


Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 99 m
Area/Valvula 1.29 has
Q/valvula 28.60 m3/hr

Q-GOTERO 0.4 lph


Dh 1.8 m
Dg 0.1 m
CAP. RIEGO 2.222 mm/hr
Long. Lateral 130 m
Long-Distribuidora 99 m
Area/Valvula 1.29 has
Q/valvula 28.60 m3/hr

384494708.xls04/18/201880
SISTEMA DE RIEGO POR GOTEO MODELO

CUADRO No.2: PERDIDAS POR FRICCION RED DE TUBERIAS: SEGUN HAZEN&WILLIAMS

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM C F VEL(M/S) HFRICCION-M COTA-MSNM DIF.COTA-M DIF.PRES-M PRES.DINAMICA.-M
A CABEZAL 31.00 12.69
A-B 100.00 146 152 150 1 1.53 1.85 29.50 1.50 0.35 12.35
B-C' 75.00 136 133 150 1 1.50 1.93 27.60 1.90 0.03 12.31
C'-D' 75.00 106 133 150 1 1.50 1.51 26.50 1.10 0.41 11.91
D'-E' 75.00 124 133 150 1 1.50 1.76 25.40 1.10 0.66 11.24
E'-F' 25.00 45 85.6 150 0.374 1.21 0.27 25.00 0.40 -0.13 11.38
F'-G' 20.00 75 71.2 150 0.365 1.40 0.71 24.00 1.00 -0.29 11.67
G'-H' 0.37 100 13.5 140 0.365 0.72 2.17 23.50 0.50 1.67 10.00
TOTAL 10.19 7.50 (*)

ALTURA DINAMICA TOTAL POTENCIA DE BOMBEO (HPB)


CAUDAL(M3/HR) ADT (M) EFB (%) HPB
CABEZAL DE CONTROL (M) 8.00 100.00 30.46 0.75 15.04
TOPOGRAFIA (M) -7.50
FRICCION RED HF (M) 10.19 POTENCIA DE MOTOR (HPM)
HPB EFM(%) HPM
VALVULA DE CONTROL (M) 2.00 15.04 0.85 17.70
ACCESORIOS DE LA RED(M) 5.00
GOTEO(M) 10.00 ELAB.: ING. P.ARTEAGA C. CIP. 40697
MARGEN SEG. (10%) 2.77
CARGA TOTAL (M.C.A) 30.46
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 1
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.84 153.00 85.6 85 150 0.357 1.4 1.13


A-B 153.00
B-C 0.00 0.00 85.6 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -1.09

0 B-C A-B
LONGITUD 0.00 153.00
CAUDAL 0.00 28.84

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral NONSE
Long-Distribuidora 153
Area/Valvula 1.298
Q/valvula 28.84

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 2
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 18.66 230.00 71.2 124 150 0.355 1.3 1.85


A-B 230.00
B-C 0.00 0.00 71.2 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -1.45

0 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral VARIABL
Long-Distribuidora 230
Area/Valvula 0.840
Q/valvula 18.66

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 3
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 24.84 125.00 85.6 69 150 0.358 1.2 0.70


A-B 125.00
B-C 0.00 0.00 85.6 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -0.50

0 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral VARIABLE
Long-Distribuidora 125
Area/Valvula 1.118
Q/valvula 24.84

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 4
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 23.71 86.00 85.6 48 150 0.361 1.1 0.45


A-B 73.10
B-C 3.56 12.90 85.6 7 150 0.426 0.2 0.00
b-c 3.56 12.90 46.2 7 150 0.426 0.6 0.05
HF TOTAL 0.49
TOPO = -0.50

1/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral VARIABLE
Long-Distribuidora 86
Area/Valvula 1.067
Q/valvula 23.71

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 5
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 153.00
B-C 0.00 0.00 104.6 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -0.82

0 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 6
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 61.20
B-C 26.52 91.80 104.6 51 150 0.361 0.9 0.22
b-c 26.52 91.80 71.2 51 150 0.361 1.9 1.44
HF TOTAL 2.16
TOPO = -2.11

3/5 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 7
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 57.38
B-C 27.62 95.63 104.6 53 150 0.36 0.9 0.25
b-c 27.62 95.63 71.2 53 150 0.36 1.9 1.61
HF TOTAL 2.31
TOPO = -2.28

5/8 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 8
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.60 99.00 85.6 55 150 0.36 1.4 0.73


A-B 51.48
B-C 13.73 47.52 85.6 26 150 0.37 0.7 0.09
b-c 13.73 47.52 59.8 26 150 0.37 1.4 0.53
HF TOTAL 1.16
TOPO = -1.15

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 99
Area/Valvula 1.287
Q/valvula 28.60

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 9
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 15.60 54.00 71.2 30 150 0.368 1.1 0.32


A-B 30.00
B-C 6.93 24.00 71.2 13 150 0.39 0.5 0.03
b-c 6.93 24.00 46.2 13 150 0.39 1.1 0.28
HF TOTAL 0.57
TOPO = -0.58

4/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 54
Area/Valvula 0.702
Q/valvula 15.60

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 10
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 133 85 150 0.357 0.9 0.29


A-B 76.50
B-C 22.10 76.50 133 43 150 0.363 0.4 0.04
b-c 22.10 76.50 85.6 43 150 0.363 1.1 0.35
HF TOTAL 0.60
TOPO = -0.62

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 11
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 42.82 284.66 133 158 150 0.354 0.9 0.51


A-B 142.33
B-C 21.41 142.33 133 79 150 0.357 0.4 0.07
b-c 21.41 142.33 85.6 79 150 0.357 1.0 0.61
HF TOTAL 1.04
TOPO = 1.01

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral VARIABLE
Long-Distribuidora 284.66
Area/Valvula 1.927
Q/valvula 42.82

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 12
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 37.97 131.28 104.6 73 150 0.358 1.2 0.61


A-B 131.28
B-C 0.00 0.00 104.6 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -0.52

0 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 131.28
Area/Valvula 1.709
Q/valvula 37.97

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 13
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 133 85 150 0.357 0.9 0.29


A-B 153.00
B-C 0.00 0.00 133 0 150 #DIV/0! 0.0 #DIV/0!
b-c 0.00 0.00 0 0 150 #DIV/0! #DIV/0! #DIV/0!
HF TOTAL #DIV/0!
TOPO = -0.27

0 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 14
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 133 85 150 0.357 0.9 0.29


A-B 51.00
B-C 29.46 102.00 133 57 150 0.36 0.6 0.09
b-c 29.46 102.00 85.6 57 150 0.36 1.4 0.79
HF TOTAL 0.99
TOPO = -0.99

2/3 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 15
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 28.60 99.00 85.6 55 150 0.36 1.4 0.73


A-B 55.00
B-C 12.71 44.00 85.6 24 150 0.372 0.6 0.07
b-c 12.71 44.00 59.8 24 150 0.372 1.3 0.43
HF TOTAL 1.08
TOPO = -1.06

4/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 99
Area/Valvula 1.287
Q/valvula 28.60

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 16
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 15.60 54.00 71.2 30 150 0.368 1.1 0.32


A-B 23.14
B-C 8.91 30.86 71.2 17 150 0.381 0.6 0.07
b-c 8.91 30.86 46.2 17 150 0.381 1.5 0.56
HF TOTAL 0.81
TOPO = -0.81

4/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 54
Area/Valvula 0.702
Q/valvula 15.60

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 17
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 55.08
B-C 28.29 97.92 104.6 54 150 0.36 0.9 0.27
b-c 28.29 97.92 71.2 54 150 0.36 2.0 1.73
HF TOTAL 2.40
TOPO = -2.41

5/8 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 18
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 84.15
B-C 19.89 68.85 104.6 38 150 0.364 0.6 0.10
b-c 19.89 68.85 59.8 38 150 0.364 2.0 1.50
HF TOTAL 2.34
TOPO = -2.39

4/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 19
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 25.50
B-C 36.83 127.50 104.6 71 150 0.358 1.2 0.56
b-c 36.83 127.50 85.6 71 150 0.358 1.8 1.49
HF TOTAL 1.87
TOPO = -1.90

5/6 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 20
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 57.38
B-C 27.62 95.63 104.6 53 150 0.36 0.9 0.25
b-c 27.62 95.63 85.6 53 150 0.36 1.3 0.66
HF TOTAL 1.35
TOPO = -1.35

5/8 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 21
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 133 85 150 0.357 0.9 0.29


A-B 71.91
B-C 23.42 81.09 133 45 150 0.362 0.5 0.05
b-c 23.42 81.09 85.6 45 150 0.362 1.1 0.41
HF TOTAL 0.66
TOPO = -0.66

5/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 22
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 18.93 64.80 85.6 36 150 0.365 0.9 0.22


A-B 32.40
B-C 9.47 32.40 85.6 18 150 0.379 0.5 0.03
b-c 9.47 32.40 59.8 18 150 0.379 0.9 0.19
HF TOTAL 0.38
TOPO = -0.38

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 64.8
Area/Valvula 0.852
Q/valvula 18.93

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 23
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 18.93 66.10 85.6 37 150 0.364 0.9 0.23


A-B 33.05
B-C 9.47 33.05 85.6 18 150 0.379 0.5 0.03
b-c 9.47 33.05 59.8 18 150 0.379 0.9 0.19
HF TOTAL 0.38
TOPO = -0.37

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 66.1
Area/Valvula 0.852
Q/valvula 18.93

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 24
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 37.70 130.52 104.6 73 150 0.358 1.2 0.60


A-B 65.26
B-C 18.85 65.26 104.6 36 150 0.365 0.6 0.08
b-c 18.85 65.26 59.8 36 150 0.365 1.9 1.29
HF TOTAL 1.80
TOPO = -1.84

1/2 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 130.52
Area/Valvula 1.697
Q/valvula 37.70

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 25
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 45.90
B-C 30.94 107.10 104.6 60 150 0.359 1.0 0.34
b-c 30.94 107.10 85.6 60 150 0.359 1.5 0.91
HF TOTAL 1.50
TOPO = -1.51

5/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 26
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 133 85 150 0.357 0.9 0.29


A-B 131.58
B-C 6.19 21.42 133 12 150 0.395 0.1 0.00
b-c 6.19 21.42 46.2 12 150 0.395 1.0 0.20
HF TOTAL 0.49
TOPO = -0.50

1/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 27
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 91.80
B-C 17.68 61.20 104.6 34 150 0.366 0.6 0.07
b-c 17.68 61.20 71.2 34 150 0.366 1.2 0.46
HF TOTAL 1.33
TOPO = -1.32

2/5 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 28
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 87.21
B-C 19.00 65.79 104.6 37 150 0.365 0.6 0.09
b-c 19.00 65.79 59.8 37 150 0.365 1.9 1.32
HF TOTAL 2.17
TOPO = -2.20

3/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 29
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 22.10 76.50 71.2 43 150 0.363 1.5 0.86


A-B 68.85
B-C 2.21 7.65 71.2 4 150 0.484 0.2 0.00
b-c 2.21 7.65 28.8 4 150 0.484 0.9 0.13
HF TOTAL 0.99
TOPO = -0.94

1/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 76.5
Area/Valvula 0.995
Q/valvula 22.10

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 30
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 22.10 76.50 85.6 43 150 0.363 1.1 0.35


A-B 33.66
B-C 12.37 42.84 85.6 24 150 0.372 0.6 0.07
b-c 12.37 42.84 59.8 24 150 0.372 1.2 0.39
HF TOTAL 0.68
TOPO = -0.68

5/9 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 76.5
Area/Valvula 0.995
Q/valvula 22.10

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 31
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 130.05
B-C 6.63 22.95 104.6 13 150 0.392 0.2 0.00
b-c 6.63 22.95 71.2 13 150 0.392 0.5 0.03
HF TOTAL 0.96
TOPO = -0.83

1/7 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 32
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 44.20 153.00 104.6 85 150 0.357 1.4 0.94


A-B 134.64
B-C 5.30 18.36 104.6 10 150 0.402 0.2 0.00
b-c 5.30 18.36 46.2 10 150 0.402 0.9 0.13
HF TOTAL 1.07
TOPO = -1.06
.
1/8 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 0.4
Dh 1.8
Dg 0.1
CAP. RIEGO 2.222
Long. Lateral 130
Long-Distribuidora 153
Area/Valvula 1.989
Q/valvula 44.20

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE 32
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 0.40 100.00 14 50 120 0.425 0.7 3.26


A-B 88.00
B-C 0.40 100.00 14 50 120 0.354 0.7 2.71
b-c 0.40 100.00 28.8 50 150 0.361 0.2 0.05
HF TOTAL 0.60
TOPO = -1.06
.
1/8 B-C A-B

384494708.xls04/18/201880
Q-GOTERO 2
Dh 2
Dg 0.5
CAP. RIEGO 2.000
Long. Lateral 12
Long-Distribuidora 100
Area/Valvula 0.120
Q/valvula 2.40

384494708.xls04/18/201880
QT-D d
A B C
LAB LBC
----- LT -----

LOTE
PERDIDAS POR FRICCION RED DE TUBERIAS DE DOS DIAMETROS (EN SERIE):

TRAMO CAUDAL-M3/HR LONGITUD-M DIA. INTERIOR-MM n C F VEL(M/S) HFRICCION-M

A-C 2.80 12 44 6 150 0.425 0.5 0.04


A-B 0.60
B-C 0.40 100 14 50 120 0.354 0.7 2.71
b-c 0.40 100 14 50 120 0.354 0.7 2.71
HF TOTAL 0.04
TOPO = -1.28

1 B-C A-B
LONGITUD 11.40 0.60
CAUDAL 2.66 0.14

384494708.xls04/18/201880
Q-GOTERO 2
Dh 2
Dg 0.5
CAP. RIEGO 2.000
Long. Lateral 12
Long-Distribuidora 100
Area/Valvula 0.12
Q/valvula 2.40

2.8

384494708.xls04/18/201880

Anda mungkin juga menyukai