R0, 06-04-2018
2
# Angle d(mm) d(m) d M*d/ Sd2
1 90 603 0.603 0.36 18899
2 78.75 591 0.591 0.35 18535
3 78.75 591 0.591 0.35 18535
4 67.5 557 0.557 0.31 17460
5 67.5 557 0.557 0.31 17460
6 56.25 501 0.501 0.25 15714
7 56.25 501 0.501 0.25 15714
8 45 426 0.426 0.18 13363
9 45 426 0.426 0.18 13363
10 33.75 335 0.335 0.11 10499
11 33.75 335 0.335 0.11 10499
12 22.5 231 0.231 0.05 7232
13 22.5 231 0.231 0.05 7232
14 11.25 118 0.118 0.01 3687
15 11.25 118 0.118 0.01 3687
16 0 0 0.000 0.00 0
17 0 0 0.000 0.00 0
18 11.25 118 0.118 0.01 3687
19 11.25 118 0.118 0.01 3687
20 22.5 231 0.231 0.05 7232
21 22.5 231 0.231 0.05 7232
22 33.75 335 0.335 0.11 10499
23 33.75 335 0.335 0.11 10499
24 45 426 0.426 0.18 13363
25 45 426 0.426 0.18 13363
26 56.25 501 0.501 0.25 15714
27 56.25 501 0.501 0.25 15714
28 67.5 557 0.557 0.31 17460
29 67.5 557 0.557 0.31 17460
30 78.75 591 0.591 0.35 18535
31 78.75 591 0.591 0.35 18535
32 90 603 0.603 0.36 18899
Σd2 5.81
Bending moment corresponding to Vu (Mu) = 64918.75 N-mm As per Cl. 4.9.9, ANSI/TIA-222-G
Design shear strength of anchor rod (Rnv) = 159043.5 N As per Cl. 4.9.9, ANSI/TIA-222-G
Design flexural strength of anchor rod (Rnm) = 1004563.02 N As per Cl. 4.9.9, ANSI/TIA-222-G
Interaction = 0.89
17RIT-139_Ooredoo_Monopoles (30m MF30T2-STR) Calculations
R0, 06-04-2018
Base plate check with stiffener as per "Rectangular uniformly loaded plate"
Maximum tension force in Anchor bolt = 18898.599 Kg 41.7 kips
No. of bolts = 32 Nos. 32 Nos
Diameter of pole at bottom = 1115 mm 43.90 in
PCD = 1205 mm 47.44 in
Base plate outer dia = 1295 mm 50.98 in
Base plate Thickness = 20 mm 0.79 in
Fy of plate = 240 Mpa 34.81 Kip/sq. in
Fy of Shaft = 350 Mpa 50.76 Kip/sq. in
Bending stress on the wall of the pole due to stiffener (considering Tee beam effect)
Radius of the pole bottom, R = 557.5 mm 21.95 in
Thickness of the pole, t = 8.0 mm 0.31 in
a = 36.0 mm 1.42 in
Z = 11151 mm^3 0.680 in3
Mgusset = 3.55 Kips-in Note: Max. of Mx, My considered for stress checking
fbpolewall = 11.7 Mpa 1.70 Kip/sq. in
Shaft utilization due to stiffener force = 0.033
Shaft utilization due to bending (from Report) = 0.728
Total utilization = 0.761
< 1.0 Hence safe