Itron’s latest-generation gas electronic volume converter (EVC) has been designed specifically for
diaphragm and small-range RPDs. Its compact size fits to the limited available space of small cabinets.
Corus Compact is compliant with all metrological requirements of MID (EN12405-1:2005+A2:2010) as
well as functional requirements of ARG 155-08 and CIG UNI TS11291. Data transmission to a central
system is achieved via an external GSM/GPRS modem, creating a remote reading solution that is both
simple and cost-effective.
Temperature probe
» Platinum PT1000 (1000 ohms at 0°C) SYSTEM OVERVIEW
probe Communication with Focus Compact installed in hazardous area
» Cable length: 2.5 m
Pressure transducer
HAZARDOUS AREA SAFE AREA
» Absolute pressure sensor with ranges:
• 0.7 - 2 bar absolute Meter Data Collection
Saturne - Alarm center
• 1.5 - 6 bar absolute Dashboard & Reports
RS-232
Field Work
Focus Management
Compact FDM Server
ATEX
Field Installer
FDM Mobile/Wincor
User Access Focus Compact ATEX GPRS Modem OPERATING PRINCIPLE
Read/write access to parameters and »» Installation possible in hazardous area The volume registered by the meter is
Corus Compact database are controlled »» User-friendly interface for simplified converted to reference conditions using
by: commissioning and handling that the following formula:
»» Access privilege defined according to includes Vb= Vm x Pm/Pb x Tb/Tm x Zb/Zm
user profile • Indicators (such as GSM reception Terminology
»» 6 different user profiles level) »» Vm unconverted volume registered by
»» 10 users maximum per user profile with • Diagnostic counters (such as GPRS the meter
at least 1 administrator data traffic) »» Vb converted volume in reference
• Alarms (such as SIM card issues) (base) conditions
Configuration software
»» Quad-band GSM/GPRS modem, »» Tm gas temperature in operating
Wincor software is used for local
communications through the optical port »» Five year battery life expectancy with conditions
of Corus Compact or its modem to: daily communication (GPRS) »» Tb reference (base) temperature
Technical Specifications
Corus Compact
Overall accuracy of the C Maximum Error < 0.5 % - Typical Error < 0.15%
factor
Power supply Battery with 5 years autonomy (battery version) in typical conditions
Temperature range Ambiant temperature: -25°C to +55°C
Gas temperature: -25°C to +70°C
Enclosure IP65 polycarbonate box
Volume input LF input (2 Hz max) with 1 anti-tampering input
Temperature sensor PT1000; (2.5 meters cable length)
External Pressure sensor Pressure ranges: 0.7 - 2 bar and 1.5 - 6 bar absolute
Outputs 2 Channels fully configurable as pulse or alarm
User Interface With graphic display
Communication RS232 port can be replaced by another port (RS485, radio,...)
ATEX approval Approval certificate from NMI T10388
ATEX approval II 1 G Ex ia IIA T3 ZELM 11 ATEX 0469X
71
93
149
119
Corus Compact
GRAPHIC DISPLAY
Possiblity to translate messages
Corus Focus
35
Compact Compact
display display Wall/pipe mounting kit
Volume pulse
Ex isolator or alarm
L 20 m
220 V AC
or 24 V DC
Volume pulse
Ex isolator or alarm
L 20 m
220 V AC
or 24 V DC
Create a more resourceful world. Visit itron.com to learn more. ITRON GmbH
Hardeckstraße 2
D-76185 Karlsruhe
Germany
Phone: +49-721 5981 0
Fax: +49-721 5981 189
While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness,
or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to
the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
© Copyright 2014, Itron. All rights reserved. GA-CORUSCOMPACT-05-EN-02-14