Anda di halaman 1dari 10

Compressor and Gas Turbine

Technology Seminar
(CGTS)
Siemens Oil & Gas

Driver Options

Copyright © Siemens AG 2008. All rights reserved.


String Competence in Energy

Siemens Energy has


global capability to
design, manufacture,
assemble, test,
install and service a
unique variety of
compressor solutions
for Oil & Gas
applications

Copyright © Siemens AG 2008. All rights reserved.


Page 2 May 2008 Energy Sector
String Competence in Energy

Oil & Gas Solutions

Oil and Gas fields LNG On-site power Systems integration


ƒ Gas /oil separation ƒ Propane ƒ Gas turbine ƒ Turbo-
ƒ Export (platform) ƒ MCR Gensets Compressors
– Simple cycle
ƒ Gas gathering ƒ Flash gas ƒ Reciprocating
– Combined cycle
ƒ Gas lift compressors
ƒ Boil-off gas ƒ Steam turbine
ƒ Gas injection ƒ Gas Turbines
ƒ Fuel gas gensets
ƒ Water injection ƒ Steam Turbines
ƒ E-LNG ƒ Mobile power
ƒ Recompression ƒ Pumps
ƒ Gas treatment ƒ Generators
ƒ Gas transmission ƒ Electric motors
ƒ Oil transmission – variable speed
– fixed speed
ƒ Natural gas storage
ƒ Process
ƒ Oil storage
packages
Copyright © Siemens AG 2008. All rights reserved.
Page 3 May 2008 Energy Sector
String Competence in Energy

Copyright © Siemens AG 2008. All rights reserved.


Page 4 May 2008 Energy Sector
Steam Turbine Portfolio

Figures in net MW
SST-9000 1,900
SST-8000 1,100
SST-6000 1,200
SST-5000 700
SST-4000 300
SST-3000 250
SST-1000 200
SST-900 150
Oil & Gas
SST-800 150
SST-700 130
SST-600 100
SST-500 85
SST-400 65
SST-300 50
SST-200 10
SST-100 9
SST-050 3
KK&K 0,45 - 5 Copyright © Siemens AG 2008. All rights reserved.
Page 5 May 2008 Energy Sector
Electric Motors Portfolio

Low Voltage Motors up to 1000 Medium Voltage Motors up to 100


kW MW

Medium Voltage Converters up to 100


Low Voltage Converters up to 1200 MVA
kW

Copyright © Siemens AG 2008. All rights reserved.


Page 6 May 2008 Energy Sector
Electric Motors Portfolio

H-compact H-compact Series H-modyn Special


IEC PLUS 1R.5/S.5 IEC, ANEMA motors
IEC, ANEMA IEC
200 - 3000 kW 1000 - 7000 kW 7000 - 10000 kW 7000 - 50000 kW 2000 - 100000 kW
1340 – 9390 HP 9390 – 67000HP

2 - 11 kV 3.3 - 13.2 kV 3.3 - 13.2 kV 6 - 13.2 kV 690 V - 13.2 kV


2 - 12 pole 2 - 12 pole 4 - 24 pole 2 - 12 pole
Squirrel cage
Squirrel cage Squirrel cage Squirrel cage Squirrel cage synchronous
slip ring rotor Synchronous
Cast iron housing Cast iron-/ Synchronous
with cooling ribs Steel housing,
cooler assembly Cast iron-/ Example:
IP55 Base frame,
IP23, IP55, WP II Steel housing, Highspeed
Water cooling
cooler assembly compressor
IP55, WP II drive
IP55, WP II
ANEMA
150 - 2500 HP
ANEMA
0.2 – 11 kV 200 - 10000 HP
2 - 16 pole
0.2 - 13.8 kV
Squirrel cage 2 - 16 pole
Retrofit
Cast iron housing Squirrel cage
with cooling ribs • Existing motors
Cast iron housing with standard
IP55/TEFC windings
cooler assembly
• May be operated
ODP, WP I, WP II, with sine-wave filter
TEAAC/TEWAC (GM150(IGBT) only)

Copyright © Siemens AG 2008. All rights reserved.


Page 7 May 2008 Energy Sector
Gas Turbines Portfolio

Copyright © Siemens AG 2008. All rights reserved.


Page 8 May 2008 Energy Sector
Starting a Compressor String

VSDS EM

Copyright © Siemens AG 2008. All rights reserved.


Page 9 May 2008 Energy Sector
Disclaimer

This document contains forward-looking statements and information – that is, statements related to future, not past,
events. These statements may be identified either orally or in writing by words as “expects”, “anticipates”, “intends”,
“plans”, “believes”, “seeks”, “estimates”, “will” or words of similar meaning. Such statements are based on our current
expectations and certain assumptions, and are, therefore, subject to certain risks and uncertainties. A variety of
factors, many of which are beyond Siemens’ control, affect its operations, performance, business strategy and results
and could cause the actual results, performance or achievements of Siemens worldwide to be materially different from
any future results, performance or achievements that may be expressed or implied by such forward-looking
statements. For us, particular uncertainties arise, among others, from changes in general economic and business
conditions, changes in currency exchange rates and interest rates, introduction of competing products or technologies
by other companies, lack of acceptance of new products or services by customers targeted by Siemens worldwide,
changes in business strategy and various other factors. More detailed information about certain of these factors is
contained in Siemens’ filings with the SEC, which are available on the Siemens website, www.siemens.com and on
the SEC’s website, www.sec.gov. Should one or more of these risks or uncertainties materialize, or should underlying
assumptions prove incorrect, actual results may vary materially from those described in the relevant forward-looking
statement as anticipated, believed, estimated, expected, intended, planned or projected. Siemens does not intend or
assume any obligation to update or revise these forward-looking statements in light of developments which differ from
those anticipated.

Trademarks mentioned in this document are the property of Siemens AG, it's affiliates or their respective owners.

Copyright © Siemens AG 2008. All rights reserved.


Page 10 May 2008 Energy Sector