2. Work principle
(I) Electromagnetic vibration install: The seed puts on the material plate, to
be helix.
(2) In helix trough rise seed, fall from the fall exit. Projects through the
photo electricity transformation area lo the silicon photoelectric generator
on his the electric current change, obtains the photo electricity after the
pulsation enlargement reshaping lo count the pulsation, sends in the
microcomputer 10 control counts the display circuit.
(3) Count display action by microchip control, count signal enters microchip
from the outside center fracture, in microchip finish the number processing
and storage. The microchip control numerical code tube position chooses
signal 74LSI38 to carry on the position to the digital tube to elect. Microchip
change to read signal TXD put to74LSI64, then move to LED display. We can
read from the LED display screen.
(4) Pre-set stop action by microchip control too, when the number is the
same as pre-set number, stop work, off microchip cut outside, so stop work,
LED show the pre-set number.
(5) Pre- value and Electric circuit check, press set button, the digital tube
demonstrated cuts the establishment environment, by “up, down, left,
right” button (“up, down” add and reduces number, “left, right” set
number the displacement in position) finish press set button, Promotes the
establishment environment, the digital tube show 00000u The user may
examine the set number, press look button。Examined the function to be
able to the user formerly numerical code tube demonstration automatic
5. LBD display 6. Hopper 7.Up, Down, Left, Right button 8.Set button
4. Zero: when display screen has number, press “zero” button. Display
screen will show “00000”.
6. Speed set: it has 1-7 for setting, to set the count speed. I is slowest, 7 is
Quickest, you can change it by different sample.
Instrument whole operation: Installs the instrument, put the sample to the
sample plate, put a container in the exit, set the count number,
press ”count” button, you can set the count speed, when count number to
the set number, the instrument stop work automatic 0 When the second
operation,press ”zero “ button.
1. Count sample: Because mixes in the seed sample also able to form the
projection in the light pipe to count, so the sample please don’t have mixes.
2. Choose the suitable plate. Because of the correct count requests seed in
a line, fall in turn, fall a grain to have a projection, counts I grain. If plates
track widths are big, two grains of or two grain of above seeds, but forms a
projection on the light pipe, the mistake counts is only 1 grain.
4. Does when willfully counts, the pre-placed value should be bigger than
counts the value.
6. If the machine doesn’t work normal the pressed key does not work and
so on please restarts.
6. Instrument maintenance
1. The starting machine numerical code tube is not bright: check the plug,
the electric wire, the switch and the fuse.
4. Exit obstruction, the sample is wide than 4mmor to long: take out the
plate then use 2 wooden sliver removes.
7. Technicalspecification
3. Count speed: >= 1000 /3min (this is in 2if you want fast you can change
to 3-7)
4. Count number range: 1-99999 LED display read direct.
12. Action: Pre- value Setting, Electric circuit correction automatic, willfully
counts, Pre- value stop automatic.