= Type tests of cating switch ace. To IEC 60129 for above mentioned eguirements = = OWNER may require its represetative(s) to alend some or all of the routine tests ace. to stme above TEC publications. t f i i E i i I i i Ring Main Ui Sesion 16343 ee snes 000 TSSUED FOR Jenene Oogo wera] yy ssuap FoR TENDER HEC mcmmenncconserranscroursa | AUTOUATICTRANGTIR ECG ALD os ENGINEERING CONSULTANTS GROUPS CONTENTS, SECTION 16415 AUTOMATIC TRANSFER SWITCHES age, PARTI GENERAL 2 LL Related Documents 2 12 Summary 2 13 Quality Assurance 2 14 Submitals a 155 Delivery, Storage and Handing 4 16 Instructions and Training on Operation and Maintenance PART? PRODUCTS 5 21 Manufactarers 5 22 Automatic Transfer Switch (ATS) 5 23° Enclosure 7 24 Testing 8 PART3 EXECUTION ° 3.41 Installation 9 32 Operational Testing 9 PARTI a 12 ECGUcK Muir ENGNEERING CONSULTANTS GROUPE. SECTION 16415 AUTOMATIC TRANSFER SWI GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contact, including General Conditions, Conditions of Particular Application and Division-1 Specification Sections, apply to this Section ‘SUMMARY, ‘This soeton covers the fumishing, the installing, and the placing in ‘operation ofthe Automatic Transfer Switch QUALITY ASSURANCE [Reference Standards Governing Standards: Except as modified oF supplemented herein, all ‘equipment and materials required in this setion including thet installation Shall conform tothe applicable requirements ofthe following standards, ‘Standards current atthe time of tender shall be use. [National Electrical Manufacturers Assocation NEMA No, ICS1_Industeal Contos and Systems ICS2 Industrial Control Devices, Controllers and Assembles ICS4 Terminal Blocks for Industrial Use ICS6 Enclosures for Industal Cont and Systems [National Fire Protection Associaton NEPA No, 10 National Eletrical Code 99 Standards for Health Care Facilites 110 Emergency and Standby Power Systems Underwriters Laboratories ne ‘ian em eon Pim 1621) ae 14 Lat 142 143 ECG MLD io. ULNo, 1008 Automatic Transfer Switches Installer’s Qualifications: The Contactor shall submit data showing that he as suvcessfully installed systems of the same type and design as specified herein, of that the Contractor has a firm contractual agreement ‘ith a subcontractor having not less than tn yours experience inthe design ‘snd installations of such system, Data shall include names and cation ofa least two installation he or his referenced subcontractors has istalled such stems. The references shall indicate type and design of each system and ‘ertication that each systems has performed satisfactorily ir the manner {intended for not les han thee year. Owner's Acceptance and Contractor's Responsibility: The Owner's ‘acceptance of the Contracor’s working drawings shall not relieve the Contactor fom responsiblity for rors omissions, or deficsnies in th work. The Contractor shall verify actual conditions in the field and shal take all measurements nccessary for proper installation of this work. ‘SUBMITTALS ‘Submit the following in accordance with the requirements Se: forth at the Conditions of Contract, Drawings and Data: One line diagram of ATS assembly and cementary or schematic and wiring diagram of the wnit n plastic lamination permanently Secured tothe inside ofthe front enclosure door, An interface equipment Connection diagram showing all conduits and wiring between the ATS a other related equipment. The one-line diagram shall show insrlocking provisions and cautionary notes, if any. 1t shall also general arrangement and complete dimensional lyout of the esuipment Above drawings shall show components description, technical ratings of ‘shipment and materia Certifleates: Test ostfcaes shall be exeeuted and submited prio to final inspection and acceptance in accordance with the requrements of NEMAVIEC standards. The certified tess reports shall show dt, time and duration ofthe overload, endurance and temperature tests, and thatthe unit under test was not de-energized during the test sequence. Thee certified copies of each test cortete shall be submited 10 the Owner's Representative ‘Test Plan: Test plan and tet procedures forthe acceptance tests. The test plan and test procedures shall explain in deal, step-by-step actions and ‘expected results fo demonstrate compliance with the requirements specific. ECG AUMMDiere [ENGINEERING CONSULTANTS GROUP The procedure shall also explain methods for simulating tke necessary conditions of operation to demonstate system performance. 144 Acceptance Tests: Test poms in booklet form showing all field tests are performed to adjust each component and to prove compliance with the ‘specified performance eriteia, upon completion and testing ofthe installed ‘stem. The reports shall include the manufacturer, model number, snd ‘ial numberof test equipment used in each tet. Each report shall indicate the final position ofcontos and operating mode ofthe sytem, Las ations and Maintenance ManualCharts and Spare Part ‘Complete operations and maintonance manuslicharts eluding spare pats ata and wiring diagrams of all equipment fumished under this ston. 15 DELIVERY, STORAGE AND HANDLING. 15.1 Storage: Supplementing the storage requirements described in Section (1605, General Equipment Stipulations the manuficturer shall acknowledge storage conditions a the time of submitting his Tender. The equipment may not be operational within 90 days afer manufacture, and the anufacturet shall erat and prepare the equipmeat for export transportation and long- term storage. Precautionary measures for prolonged storage shall be provided by the mancfictorer atthe factory, The Contraco shall be responsible for storage and maintenance of the protective measures as recommended and insracted by the manufacturer while stored «the storage site, In addition to the protection specified for prolonged storage, ths packaging ‘of spare pars shal be prepared for export packing and shall be suitable for long-term storage in a damp location. Each spare item skal. be packed separately and shall be completely identified on the outside of the container. Instrections forthe servicing of equipment while in longterm er prolonged storage shall accompany cach item of equipment. An enclose instruction ‘with each package shall be noted on the exterior ofthe package and shall be inthe Arabic and English languages. 152 Veriflstion of Dimensions: The Contractor shall become familar with the “ets ofthe work snd working conditions, shall verity dimensions in the ficld, and shall advise the Owner's Representative of any dscrepancies before performing th work 1.53 Warranty: ‘The Maintenance Period for the equipment snd appurtenances Ball begin when the performance test on the equipment and appurtenances has been successfully completed and preliminary aocepted as stipulated in the Conditions of Contract, 154 Spare Parts: All ists ofall spare parts required for ajustmen, operation, ‘nd maintenance ofthe equipment fora period of thre years from the date 16 PART? 2 22 ECG MLW. ENGINEERING CONSULTANTS GROUP ‘of the cenificate of completion shall be provided in accordance with the ‘equiements of Section 01605, General Equipment Stipulations INSTRUCTIONS AND TRAINING ON OPERATION AND MAINTENANCE Contractor shall provide instructions and traning fo the staf be assigned in the operation and maintenance ofthe equipment specified under this Section. Training and instructions shall be'in accordance with the ‘requirements set fort atthe Conitions of Contract. propucrs (MANUFACTURERS Subject to compliance with requirements, manuficturers offing products ‘hat may be incorporated into the Work include, but sre not limited t, the ‘ones mentioned on the attached lst of manuficturers Section 01295, AUTOMATIC TRANSFER SWITCH (ATS) ATS shall be double throw, electrically operated, mechanically held, fully protected, complete with voltage sensing relay. ATS is mechanically held tnd electrically operated bya single solenoid mechanism energized from the Source 10 which the load is tobe transfered. ATS shall be suiuble for use in emergency o standby systems described in NFPA 70. ATS shall be UL. listed or anyother Esropesn Standard, and test reports ate appv 3s being ‘equivalent of test results and certified test reports as those determined and reported by UL or any other Furopean Standard. ATS. withstand symmetrical short circuit RMS is SOKA except thatthe ATS shall not be ‘equipped with ether overload or fault current prooctive devices and shal be ‘designed and manufactured to prevent stops in an intermediate or neural Position during transfer by the use of eletical actuators and tored-enery ‘Automatic Transfer Switch (ATS) shall have a continuous phase or main ‘current rating equal to or exceed the rating shown bu, inno case, es than 125 percent of the full load rating of the emergency power source, 380 Volts, 4P, $0 Hz and 50 kA symmetrical minimum interuping capacity, oF as shown onthe drawings [No Cireuit Breaks System sal be allowed, Time delay 1 override monitored source deviation ‘Shall be adjustable fom 0.5 to 6 seconds snd factory set at I second. The

Anda mungkin juga menyukai