Various fieldbuses
The indicator INTECONT Satus is The indicator for beltscales All INTECONT Satus parameters can
designed for applications using INTECONT Satus VKG 20790 be configured very easy by using the
stand-alone belt weigher has a standard stainless steel con- PC program EasyServe.
MULTIBELT® with on-site sole shaped case in protection class
IP65 that is suited for table-top andThe parameters are stored using the
electronics.
wall mounting. load cell dongle technology and
therefore are available even after
By focusing primarily on the necessi-
ties the INTECONT Satus repre- The indicator has an easily readable replacement of the main board.
sents a very attractive, simple and back lighting LCD display for show-
modern device on the market. ing measured values with clear text Since Ethernet is increasingly be-
operator guidance. Data is keyed in coming the communication standard
via flexible membrane keyboard with even in industry, INTECONT Satus
6 keys. has a standard 10/100 Mbaud net-
work connection.
Also the well-established Modbus.
BV-D2257GB
Belt weigher application
Application overview
EasyServe
DO 1 Feeder ON
Speed input DI 5 DO 2 Q > Q-Max
DO 3 Alarm
DO 4 Q < Q-Min
Ackn. event DI 1
Tare DI 2 Pulse
External Event DI 3 output Counter
AO 1 Feedrate
24 Application parameters
INTECONT Satus
170
30
50
~231 ~100
Technical data
View LCD back lighting. 1 cell 20 characters. Characters 12 mm high
Keyboard 6 keys
Supply voltage 85 - 240 VAC, 50 - 60 Hz, max. 10 VA, Variant 24 VDC
Housing Stainless steel 1.4301, deep drawn, IP65
Temperature range Service temperature: -30 °C ... +60 °C
Measuring circuit Supply voltage: 5 V alternating current supply
Range: –20 mV … +20 mV;
Load cell impedance: R min 47 Ω
Cable length: max. 1000 m
Units kg, t, lb; kg/h, t/h, lb/h;
Taring to be started via digital input or keyboard
Belt monitoring zero-drop-out; Belt load > max / < min
Binary inputs assigned signal
3 x Optocoupler, 18 - 36 VDC, typ. 5 mA Ack. event
Tare
External event
BV-D2257GB 1108 All information is given without obligation. All specifications are subject to change. © by Schenck Process GmbH, 2011
4 x relay, 230 VAC, max. 60 W Running
Belt load Q > Max
Alarm
Belt load Q < Min
Pulse output
Optocoupler, 18 - 36 VDC, max. 50 mA / 10 Hz Totalizing counter pulses
Analog output
0(4)–20 mA, 12 Bit, max. imp. 500 Ω Feedrate
Serial connections
Interface 1: RS 232 EasyServe
Interface 2: RS 232 - not used –
Equipment supplied