Anda di halaman 1dari 7

Help - Calibration 1/7

Calibration

Calibration Operator
The objective of SAR calibration is to provide imagery in which the pixel values can be directly related to the
radar backscatter of the scene. Though uncalibrated SAR imagery is sufficient for qualitative use, calibrated
SAR images are essential to quantitative use of SAR data.

Typical SAR data processing, which produces level 1 images, does not include radiometric corrections and
significant radiometric bias remains. Therefore, it is necessary to apply the radiometric correction to SAR
images so that the pixel values of the SAR images truly represent the radar backscatter of the reflecting
surface. The radiometric correction is also necessary for the comparison of SAR images acquired with different
sensors, or acquired from the same sensor but at different times, in different modes, or processed by different
processors.

This Operator performs different calibrations for ASAR, ERS, ALOS and Radarsat-2 products deriving the sigma
nought images. Optionally gamma nought and beta nought images can also be created.

Products Supported

Sentinel-1 (IW, EW, SM SLC and GRD) are fully supported

ASAR (IMS, IMP, IMM, APP, APS, APM, WSM) are fully supported

ERS 1 & 2 products (SLC, IMP) are fully supported

Radarsat-2 products are fully supported

TerraSAR-X/TanDEM-X products

ALOS 1 and 2 products

Cosmo-Skymed products

Third party SAR missions may not be fully supported for all modes.

Sentinel-1 Calibration
For converting digital pixel values to radiometrically calibrated backscatter, all the required information can be
found in the product. A calibration vector is included as an annotation in the product allowing simple
conversion of image intensity values into sigma or gamma nought values.

The objective of SAR calibration is to provide imagery in which the pixel values can be directly related to the
radar backscatter of the scene. To do this, the application output scaling applied by the processor must be
undone and the desired scaling must be applied. Level-1 products provide four calibration Look Up Tables
0 0
(LUTs) to produce � i, σ i and γi or to return to the Digital Number (DN). The LUTs apply a range-dependent
gain including the absolute calibration constant. For GRD products, a constant offset is also applied.

The radiometric calibration is applied by the following equation:

where, depending on the selected LUT,


Help - Calibration 2/7

Bi-linear interpolation is used for any pixels that fall between points in the LUT.

ASAR Calibration
For ground range detected products, the following corrections are applied:

incidence angle

absolute calibration constant

In the event that the antenna pattern used to process an ASAR product is superseded, the operator removes
the original antenna pattern, and apply a new, updated one. The old antenna pattern gain data is obtained
from the external XCA file specified in the metadata of the source product. The new antenna pattern gain data
and the calibration constant are obtained from the user specified XCA file. For XCA file selection, user has the
following options:

latest auxiliary file (the most recent XCA file available in the local repository)

product auxiliary file (the XCA file specified in the product metadata)

external auxiliary file (user provided XCA file)

If "product auxiliary file" is selected, then no retro-calibration is performed, i.e. no antenna pattern gain is
removed or applied. By default the latest XCA file available for the product is used.

For slant range complex products, the following corrections are applied:

incidence angle

absolute calibration constant

range spreading loss

antenna pattern gain

The antenna pattern gain data and the calibration constant are obtained from the user specified XCA file. For
XCA file selection, user has the following options:

latest auxiliary file (the most recent XCA file available in the local repository)

external auxiliary file (user provided XCA file)

By default, the latest auxiliary file available for the product will be used for the calibration.

The default output of calibration is sigma0 image. User can also select gamma0 and beta0 images outputting
as virtual bands in the target product.

In the following, the calibration process is related to the different type of ASAR products.

IMS Products

The sigma nought image can be derived from ESA’s ASAR level 1 IMS products as the follows (adapted from
[1]):
Help - Calibration 3/7

where

2
DNi,j is the pixel intensity for pixel i, j

K is the absolute calibration constant


α is incidence angle
i,j

R is the slant range distance


i,j

R is the reference slant range distance


ref

θ is the look angle


i,j

G is the antenna pattern gain

APS Products

The methodology to derive the sigma nought is the same of the IMS data but an additional factor (R / R )
ref
must be taken into account:

IMP, APP, IMM, APM, WSM Products

In contrast to IMS and APS products, ASAR ground range imageries (IMP, APP, IMM, APM, WSM) have all been
applied antenna gain pattern compensation (based on ellipsoid approximations) and range spreading loss
correction during the formation of the images. Therefore the antenna pattern correction applied to the image
must be removed when updated external XCA file is available for the product.

The sigma nought image can be derived from ESA’s ASAR level 1 IMP, APP, IMM, APM, WSM products as the
follows (adapted from [1]):
Help - Calibration 4/7

For detailed ASAR calibration algorithm, reader is referred to [1].

ERS Calibration
The operator is able to calibrate ERS VMP, ERS PGS CEOS and ERS PGS ENVISAT ESA standard products
generated by different ESA Processing and Archiving Facilities, such as the German PAF (D-PAF), the Italian PAF
(I-PAF) and the United-Kingdom PAF (UK-PAF), and at the acquisitions stations such as PDHS-K (Kiruna) and
PDHS-E (Esrin).

For ERS-1 ground range product, the following corrections are applied:

incidence angle

calibration constant

replica pulse power variations

analogue to digital converter non-linearity

For ERS-1 slant range product, the following corrections are applied:

incidence angle

calibration constant

analogue to digital converter non-linearity

antenna elevation pattern

range spreading loss

For ERS-2 ground range product, the following corrections are applied:

incidence angle

calibration constant

analogue to digital converter non-linearity

For ERS-2 slant range product, the following corrections are applied:

incidence angle

calibration constant
Help - Calibration 5/7

analogue to digital converter non-linearity

antenna elevation pattern

range spreading loss

For detailed ERS product calibration algorithm, reader is referred to [2].

ALOS PALSAR Calibration


The operator performs absolute radiometric calibration for ALOS PALSAR level 1.1 or 1.5 products. For ALOS
PALSAR L1.1 and L1.5 products, the following corrections have already been applied:

range spreading loss correction

antenna pattern gain correction

incidence angle correction

Therefore the operator applies only the absolute calibration constant correction to the products.

For detailed ALOS PALSAR product calibration algorithm, reader is referred to [3].

Radarsat-2 Calibration
The operator performs absolute radiometric calibration for Radarsat 2 products by applying the sigma0, beta0
and gamma0 look up tables provided in the product.

For detailed Radarsat-2 product calibration algorithm, reader is referred to [4].

TerraSAR-X
The operator performs absolute radiometric calibration for TerraSAR-X products. The following corrections have
been appllied:

calibration constant correction

incidence angle correction

Noise Equivalent Beta Naught (NEBN) correction

The "noiseCorrectedFlag" in the metadata is checked before NEBN correction is applied. The operator currently
does not support ScanSAR calibration when noiseCorrectedFlag is false. For detailed TerraSAR-X product
calibration algorithm, reader is referred to [5].

Cosmo-SkyMed
The operator performs absolute radiometric calibration for Cosmo-SkyMed products by applying few product
factor corrections.

For detailed Cosmo-SkyMed product calibration algorithm, reader is referred to [6].

Kompsat-5
Currently only High Resolution and Standard Modes are supported by the operator. Wide Swath Modes are
not supported.
Help - Calibration 6/7

High Resolution modes include the following imaging modes:

HR: High Resolution Mode

EH: Enhanced High Resolution Mode

UH: Ultra High Resolution Mode

Standard Modes include the following imaging modes:

ST: Standard Mode

ES: Enhanced Standard Mode

For High Resolution modes, the following radiometric calibration is applied:

where F is the rescaling factor and K is the calibration constant in HDF attributes, and θref is the reference
incidence angle.

For Standard Modes, the following equation is applied:

where ΔA is the pixel area given by (azimuth spacing x range spacing).

Parameters Used
The parameters used by the operator are as follows:

1. Source Band: All bands (real or virtual) of the source product. User can select one or more bands for
calibration. If no bands are selected, then by default, all bands are used for calibration. The operator is
able to detect the right input band.

2. Auxiliary File: User selected XCA file for antenna pattern correction. The following options are available:
Latest Auxiliary File, Product Auxiliary File (for detected product only) and External Auxiliary File. By
default, the Latest Auxiliary File is used.

3. Scale in dB: Checkbox indicating that the calibrated product is saved in dB scale. If not checkmarked,
then the product is saved in linear scale.

4. Create gamma0 virtual band: Checkbox indicating that gamma0 image is created as a virtual band. If not
checkmarked, no gamma0 image is created.

5. Create beta0 virtual band: Checkbox indicating that beta0 image is created as a virtual band. If not
checkmarked, no beta0 image is created.
Help - Calibration 7/7

Reference:

[1] Rosich B., Meadows P., Absolute calibration of ASAR Level 1 products, ESA/ESRIN, ENVI-CLVL-EOPG-TN-03-
0010, Issue 1, Revision 5, October 2004

[2] Laur H., Bally P., Meadows P., S�nchez J., Sch�ttler B., Lopinto E. & Esteban D., ERS SAR Calibration:
Derivation of σ0 in ESA ERS SAR PRI Products, ESA/ESRIN, ES-TN-RS-PM-HL09, Issue 2, Rev. 5f, November 2004

[3] Lavalle M., Absolute Radiometric and Polarimetric Calibration of ALOS PALSAR Products, Issue 1, Revision 2,
01/04/2008

[4] RADARSAT Data Product Specification, RSI-GS-026, Revision 3, May 8, 2000

[5] Radiometric Calibration of TerraSAR-X data - TSXX-ITD-TN-0049-radiometric_calculations_I1.00.doc, 2008

[6] For further details about Cosmo-SkyMed calibration please contact Cosmo-SkyMed Help Desk at info.cosmo@e-
geos.it

Anda mungkin juga menyukai