Anda di halaman 1dari 2

Inductive Sensor

with Increased Switching Distance

I18H008
Part Number Technical Data
Inductive Data
Switching Distance 12 mm
Correction Factors Stainless Steel V2A/CuZn/Al 0,94/0,43/0,41
Mounting quasi-flush
Mounting A/B/C/D in mm 18/46/36/5
Mounting B1 in mm 0...26
Switching Hysteresis < 10 %
Electrical Data
Supply Voltage 10...30 V DC
Current Consumption (Ub = 24 V) < 12 mA
Switching Frequency 380 Hz
Temperature Drift < 10 %
Temperature Range -40...80 °C
Switching Output Voltage Drop <1V
Switching Output/Switching Current 150 mA
Residual Current Switching Output < 100 µA
Short Circuit Protection yes
Reverse Polarity and Overload Protection yes
Protection Class III
Mechanical Data
Housing Material CuZn, nickel-plated
Degree of Protection IP67
Connection M12 × 1; 4-pin
Increased switching distance Safety-relevant Data
Innovative ASIC circuit technology MTTFd (EN ISO 13849-1) 3706,54 a
Integrated error display Function
Error Indicator yes
Minimal mounting clearance thanks to wenglor we-
proTec PNP NO/NC antivalent

Connection Diagram No. 101


Suitable Connection Technology No. 2
Suitable Mounting Technology No. 150 152

Inductive Sensors with increased switching distances


are distinguished by rugged design, easy installation
and reliable measured values. The large range makes
additional types of sensor superfluous because they
can also be used to implement special applications. In
addition to error-free operation of several sensors in a
very small space, the new generation also provides the
possibility of detecting system errors before it's too late
thanks to ASIC und wenglor weproTec.

Complementary Products
PNP-NPN Converter BG2V1P-N-2M

Inductive Sensors
1 = Switching Status Indicator
Sleeve M18×1 = 30 Nm
All dimensions in mm (1 mm = 0.03937 Inch)

101 Legend PT Platinum measuring resistor Encoder A


Supply Voltage + not connected Encoder B
Supply Voltage 0 V Test Input Digital output MIN
Supply Voltage (AC Voltage) Test Input inverted Digital output MAX
Switching Output (NO) Trigger Input Digital output OK
Switching Output (NC) Analog Output Synchronization In
Contamination/Error Output (NO) Ground for the Analog Output Synchronization OUT
Contamination/Error Output (NC) Block Discharge Brightness output
Input (analog or digital) Valve Output Maintenance
Teach Input Valve Control Output +
Time Delay (activation) Valve Control Output 0 V
Shielding Synchronization Wire Colors according to
Interface Receive Path Receiver-Line DIN IEC 757
Interface Send Path Emitter-Line Black
Ready Grounding Brown
Ground Switching Distance Reduction Red
Clock Ethernet Receive Path Orange
Output/Input programmable Ethernet Send Path Yellow
Interfaces-Bus A(+)/B(–) Green
Power over Ethernet Emitted Light disengageable Blue
Safety Input Magnet activation Violet
Safety Output Input confirmation Grey
Signal Output Contactor Monitoring White
Ethernet Gigabit bidirect. data line (A-D) Encoder A/A (TTL) Pink
Encoder 0-pulse 0-0 (TTL) Encoder B/B (TTL) Green/Yellow

Mounting
Specifications are subject to change without notice