Anda di halaman 1dari 1

A10

A6-A7
S1 S2 S3 S4 S5 S6 S7 S8 BB area
-A11

Control room
A200
Ground floor
Mixer area 1st floor
PC «Master» PC «Redundant» L10 – L11

Building 3
DosaVision (FTView SE) DosaVision (FTView SE)
Replication

Printer Guerin Systems Hotline


TeamViewer
+ Telcel 3G USB Key
(supplied by Mondelez)
D’
A2 A2+ A13
SW2

L5 - L6 - L7-A - L7-B - L8 – L9
A3 - A4 - A5 - A8 - A12
Bay

Control room

Mixer area

Building 2
SW1

SW4
Switch 1
(Managed)

Update DosaVision
Screens Line 10
(no Recipe)

A200 BC2002

Panel PC
A’
Area Management
DosaVision (FTView)
Building 2 – 2nd floor Use Bin, Liquids, A
Production line 10 (+ L11 futur) SW20002
(UnManaged) PLC5 1st floor
PLC 3 A1
S1 S2 3rd floor
ControlLogix L72
Card2 (PC)
Use Bin
S3 S4
Card1 (I/O)

- Ethernet Optical Fiber - - Ethernet RJ45 - - Ethernet RJ45 - S5 S6 Mixer L1-L3 area

Building 1
Main control panel n°3 (A200) DosaVision Line 10
B
Update I/O
A100 A2 Line 10 T1 T2 T3

A9

A101 A100
(Use bin) Switch
Area Management Area Management

SW3
Inside silo, Use Bin 3rd floor, Outside silo, Use Bin, Liquids, T4 T5 T6 1st floor
Switch Switch Switch
Production line 1, 3 (via PLC5) Production line 5, 6, 7-1, 7-2, 8, 9 SW ?
SW1301 SW20001 SW20003
(Raptronic)

PLC 2 Switch 3 PLC 1 Switch 2


ControlLogix L72 (UnManaged) ControlLogix L63 ( + IO) (UnManaged) Flex I/O Flex I/O Flex I/O Flex I/O Flex I/O PanelView+7 Flex I/O Weighing
Card2 (PC) Card2 (PC) 600 System

C
Card1 (I/O) Card1 (I/O)
Soybean
A2 Extension A2 Extension (A200) (BP2001) (BP2002) (BC2001) (BP2003) W201201 - / (PLC Mixer) Oil
Main control panel n°1 (A2) /-/
(A13) (BP1301)
DH+ Network
PLC Raptronic
CNet 1 CNet 2 Switch Line 10 (A200, ...)
(Axxxx)
SW201
Ethernet Network
1

Building 3 – Ground floor


Switch
SW10001

Flex I/O 20
Managed by Mondelez
9
Ethernet Network Switch 4
(UnManaged)

Main control panel n° 2 (A100)


Flex I/O

Switch + I/O Eth Switch Switch + I/O Eth Switch + I/O Eth Switch + I/O Eth Switch + I/O Eth

Main control panel n°1 (A2') 4...20mA 4...20mA

PowerFlex PowerFlex PowerFlex PowerFlex PowerFlex PowerFlex


CompactLogix Frequency PanelView+ SLC 500 Frequency PanelView CompactLogix Frequency PanelView+ CompactLogix Frequency PanelView+ CompactLogix Frequency PanelView+ CompactLogix Frequency PanelView+
L23E Inverter 1000 5/05 Inverter 600 L23E Inverter 1000 L23E Inverter 1000 L32E Inverter 1000 L23E Inverter 1000
Switch Building 2 – 1st floor
SW100201

Flex I/O Weighing


Peerless Line 5 Peerless Line 6 Peerless Line 7-1 Peerless Line 7-2 Peerless Line 8 Peerless Line 9
System
Flex I/O Flex I/O Flex I/O
Building 2 – 1st floor

W1012 – W1022
W1023 - /
ControlNet Network 2
Use Bin 3rd floor area
Line 1, Line 3 area (BP1002) Line 1, Line 3 area (BP1003) Line 1, Line 3 area (BP1004)
(BP1001) 6 7 8 10 11 13 BNC Plug to
Plug (in A5)

Building 1 – 3rd floor Building 1 – 1st floor 16 17 18

3 4 5
Building 1 – 1st floor ControlNet Network 2

Switch
ETH1201

Watermix
Flex I/O Flex I/O Weighing Watermix Flex I/O Weighing CompactLogix Flex I/O Flex I/O Weighing Watermix Flex I/O Weighing Watermix Flex I/O Flex I/O Weighing Watermix
System (4 – 20 mA) System L23E System (4 – 20 mA) System System (4 – 20 mA)

A101 W301 - W311 W302 - W312 W303 - W307 W304 - W314 W306 - W316
Switch Switch /-/ W313 - W317

SW101 SW101101
Line 5 (A12) Line 6 (A3) Lines 7-1 & 7-2 (A8) Line 8 (A4) Line 9 (A5)

Flex I/O Flex I/O Flex I/O PLC5 PLC5 I/O PLC5 I/O PanelView+6
1500 Building 2 – Framework 1st floor

ControlNet Network 1

Silo 101...105 area (A101) Silo 101...105 area (BP1011) Line 1, Line 3 area (Mondelez Axx)

Building 1 – Ground floor Building 1 – 1st floor

19 21 2 12 14 15 24 25 22 23
Building 1 – 1st floor

Flex I/O PanelView+ Flex I/O PanelView+6 Flex I/O PanelView+ Flex I/O Flex I/O Flex I/O Flex I/O PanelView+
600 1000 600 1000

Tank 70x area (A9) Silo 101...105 area (A1) (BC1011) Silo 141-142 area (A6) Silo 143-144 area (A7) Silo 145-146-147-148 area (A11) BB silo area (A10)

Building 1 – Ground floor Building 1 – Ground floor Outside silos Building – Ground floor MIXER AREA

OUSTSIDE SILOS

INSIDE SILOS

LIQUIDS

CONTROL ROOM

LINE 10 BARNI

- MUST BE UPDATE -

18 Frequency inverter 9 Flowmeter (pulse) 4 Continuous level AUTOMATION ARCHITECTURE


(14 in 4 ... 20mA) (Digital Input) (4 ... 20mA)

Mondelez Monterrey
PF-10264385 Date: 25/01/16 1/1

Anda mungkin juga menyukai