A6-A7
S1 S2 S3 S4 S5 S6 S7 S8 BB area
-A11
Control room
A200
Ground floor
Mixer area 1st floor
PC «Master» PC «Redundant» L10 – L11
Building 3
DosaVision (FTView SE) DosaVision (FTView SE)
Replication
L5 - L6 - L7-A - L7-B - L8 – L9
A3 - A4 - A5 - A8 - A12
Bay
Control room
Mixer area
Building 2
SW1
SW4
Switch 1
(Managed)
Update DosaVision
Screens Line 10
(no Recipe)
A200 BC2002
Panel PC
A’
Area Management
DosaVision (FTView)
Building 2 – 2nd floor Use Bin, Liquids, A
Production line 10 (+ L11 futur) SW20002
(UnManaged) PLC5 1st floor
PLC 3 A1
S1 S2 3rd floor
ControlLogix L72
Card2 (PC)
Use Bin
S3 S4
Card1 (I/O)
- Ethernet Optical Fiber - - Ethernet RJ45 - - Ethernet RJ45 - S5 S6 Mixer L1-L3 area
Building 1
Main control panel n°3 (A200) DosaVision Line 10
B
Update I/O
A100 A2 Line 10 T1 T2 T3
A9
A101 A100
(Use bin) Switch
Area Management Area Management
SW3
Inside silo, Use Bin 3rd floor, Outside silo, Use Bin, Liquids, T4 T5 T6 1st floor
Switch Switch Switch
Production line 1, 3 (via PLC5) Production line 5, 6, 7-1, 7-2, 8, 9 SW ?
SW1301 SW20001 SW20003
(Raptronic)
C
Card1 (I/O) Card1 (I/O)
Soybean
A2 Extension A2 Extension (A200) (BP2001) (BP2002) (BC2001) (BP2003) W201201 - / (PLC Mixer) Oil
Main control panel n°1 (A2) /-/
(A13) (BP1301)
DH+ Network
PLC Raptronic
CNet 1 CNet 2 Switch Line 10 (A200, ...)
(Axxxx)
SW201
Ethernet Network
1
Flex I/O 20
Managed by Mondelez
9
Ethernet Network Switch 4
(UnManaged)
Switch + I/O Eth Switch Switch + I/O Eth Switch + I/O Eth Switch + I/O Eth Switch + I/O Eth
W1012 – W1022
W1023 - /
ControlNet Network 2
Use Bin 3rd floor area
Line 1, Line 3 area (BP1002) Line 1, Line 3 area (BP1003) Line 1, Line 3 area (BP1004)
(BP1001) 6 7 8 10 11 13 BNC Plug to
Plug (in A5)
3 4 5
Building 1 – 1st floor ControlNet Network 2
Switch
ETH1201
Watermix
Flex I/O Flex I/O Weighing Watermix Flex I/O Weighing CompactLogix Flex I/O Flex I/O Weighing Watermix Flex I/O Weighing Watermix Flex I/O Flex I/O Weighing Watermix
System (4 – 20 mA) System L23E System (4 – 20 mA) System System (4 – 20 mA)
A101 W301 - W311 W302 - W312 W303 - W307 W304 - W314 W306 - W316
Switch Switch /-/ W313 - W317
SW101 SW101101
Line 5 (A12) Line 6 (A3) Lines 7-1 & 7-2 (A8) Line 8 (A4) Line 9 (A5)
Flex I/O Flex I/O Flex I/O PLC5 PLC5 I/O PLC5 I/O PanelView+6
1500 Building 2 – Framework 1st floor
ControlNet Network 1
Silo 101...105 area (A101) Silo 101...105 area (BP1011) Line 1, Line 3 area (Mondelez Axx)
19 21 2 12 14 15 24 25 22 23
Building 1 – 1st floor
Flex I/O PanelView+ Flex I/O PanelView+6 Flex I/O PanelView+ Flex I/O Flex I/O Flex I/O Flex I/O PanelView+
600 1000 600 1000
Tank 70x area (A9) Silo 101...105 area (A1) (BC1011) Silo 141-142 area (A6) Silo 143-144 area (A7) Silo 145-146-147-148 area (A11) BB silo area (A10)
Building 1 – Ground floor Building 1 – Ground floor Outside silos Building – Ground floor MIXER AREA
OUSTSIDE SILOS
INSIDE SILOS
LIQUIDS
CONTROL ROOM
LINE 10 BARNI
- MUST BE UPDATE -
Mondelez Monterrey
PF-10264385 Date: 25/01/16 1/1