0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
66 tayangan18 halaman
1) Zanotti developed a monoblock refrigeration system for marine cold storage applications using low GWP refrigerants.
2) The system is designed to withstand the pitching and rolling of ships with features like an evaporator tray that can discharge water at a 15 degree inclination.
3) Acceptable refrigerant alternatives to R407F include R448A, R449A, and R452A, with R452A being the best option for low temperature applications using hermetic compressors.
1) Zanotti developed a monoblock refrigeration system for marine cold storage applications using low GWP refrigerants.
2) The system is designed to withstand the pitching and rolling of ships with features like an evaporator tray that can discharge water at a 15 degree inclination.
3) Acceptable refrigerant alternatives to R407F include R448A, R449A, and R452A, with R452A being the best option for low temperature applications using hermetic compressors.
1) Zanotti developed a monoblock refrigeration system for marine cold storage applications using low GWP refrigerants.
2) The system is designed to withstand the pitching and rolling of ships with features like an evaporator tray that can discharge water at a 15 degree inclination.
3) Acceptable refrigerant alternatives to R407F include R448A, R449A, and R452A, with R452A being the best option for low temperature applications using hermetic compressors.
Sustainable Management of Refrigeration Technologies in
Marine and Off-Shore Fisheries Sectors , 6-8 April 2017 ,
Bangkok
Monoblocks System for Marine Application
with Low GWP Refrigerant for Fresh and Frozen Products in Marine Coldstores
Lorenzo Bulgarelli Development Manager
Zanotti S.p.A. l-bulgarelli@zanotti.com Via M.L.King n°30 +39 0376 555109 46020 Pegognaga (MN) - Italy The study of the solution comes from the specific request for refrigerating units for coldrooms in marine application Coldrooms for fresh or frozen product storage Refrigerants with low environmental impact Refrigerant: GWP < 1890 Voltage: 440/3/60 Coldroom LT: Volume: 14,6 m3 Temperatures: Internal -25°C / External +35°C Cooling capacity: 1200 watt 2 Units: the first one on, the second one in stand-by Coldroom NT: Volume: 22,1 m3 Cooling capacity: 1500 watt Temperatures: Internal +0°C / External +35°C Only 1 Unit Design targets: Easier Installation and maintenance in small space External high temperature Pitching and rolling of the ship to ensure the correct discharge of the condensate water and the oil return to the compressor. Necessary resistance to vibrations caused by the application In these slides I will show at first the design project for the unit developed and then a brief overview for refrigerant alternative Main features Semihermetic compressor able to function with 1^ Choice: R407F (GWP=1825) - Voltage: 440-3-60 Closed top cover to protect the plant against water Evaporator tray able to discharge the water till 15°of inclination Unit frame developed to pass through the coldroom door and mounting from internal side Closed top cover to protect the plant against water
Unit frame developed
to pass through the coldroom door Evaporator tray able to discharge the water till 15°of inclination
Unit frame developed
for mounting from internal coldroom side Semihermetic compressor For R407F we have to pay attention at the discharge temperature that is higher compared with R404A
The compact system help to mantain controlled
this temperature because the short pipe length. Electronic control with remote keyboard Possibility of net connection via modbus protocol Electrical connections from the bottom side Refrigerant Alternative New refrigerant option now available: R448A : GWP=1387 R449A : GWP=1397 These two has the same refrigerating effect Can be used for NT and LT with semihermetic compressors And for NT for hermetic compressors Discharge temperature for R448A-R449 is a little bit lower than R407F and this help specially for LT application
But it’s not acceptable for Hermetic compressors
for LT application
Another alternative refrigerant is R452A
R452 has GWP = 2140 Can be used for NT and LT application with hermetic compressors Discharge temperature is lower compared with R449A For this R452A it’s actually the unique solution for the hermetic compressors for LT application At this moment, the actual state of art, give these possible alternative.
In the next future we will have for sure other new
possibilities for mid or long term use. THANK YOU
QUESTIONS ?
Lorenzo Bulgarelli l-bulgarelli@zanotti.com Via M.L.King n°30 46020 Pegognaga (MN) - Italy