Vitocell-H 100
CHA Series
Vitocell-H 100
2
Product Information
Cross-Section
Tank is constructed
of steel, with Ceraprotect
two-coat enamel finish
5167 513 v1.2
3
Technical Data
Technical data
For domestic hot water heating applications in Suitable for heating systems with
conjunction with hot water heating boilers H max. DHW supply of up to 150 °F / 65.6 °C
H max. working pressure on the heat exchanger side of up to 150 psig /
10 bar
H max. working pressure on DHW side of up to 150 psig / 10 bar
H max. supply temperature on the heat exchanger side of up to 230 °F /
110 °C
Storage capacity USG 42 53
ltr 160 200
Recovery *1 MBH 113 143
with a temperature 194°F GPM 3.6 4.5
increase of the 90°C ltr/h 810 1032
domestic hot water
from MBH 96 109
176°F GPM 3.0 3.5
50 to 113°F /
80 ºC ltr/h 688 786
10 to 45°C
and heating water supply
MBH 75 89
temperature of . . . . . . 158°F GPM 2.4 2.8
at the supply flow rate 70 ºC ltr/h 540 638
stated below
Recovery *1 MBH 109 130
with a temperature 194°F GPM 2.4 2.9
increase of the 90°C ltr/h 550 653
domestic hot water
from MBH 82 99
176°F GPM 1.8 2.2
50 to 140°F /
80 ºC ltr/h 412 498
10 to 60°C
and heating water supply
MBH 58 65
temperature of . . . . . . 158°F GPM 1.3 1.4
at the supply flow rate 70 ºC ltr/h 292 326
stated below
Supply flow rate GPM 13.2 13.2
for the recovery m3/h 3.0 3.0
rates stated
Standby losses *2 MBH/24 h 4.8 5.1
Overall dimensions
Overall length inches 41½ 47¾
mm 1052 1216
Overall width inches 25¼ 25¼
mm 640 640
Overall height inches 25¾ 25¾
mm 654 654
Weight lbs 227 256
Tank with insulation kg 103 116
Heating water content USG 1.8 2.1
(heat exchanger coil) ltr 7.0 8.0
Heat exchanger surface area ft.2 10.8 12.9
m2 1.0 1.2
Connections
Heating water supply/return ’’ (male thread) 1 1
Domestic hot water/ ’’ (male thread) ¾ ¾
temperature and pressure
relief
li f valve
l
Domestic cold water ’’ (male thread) ¾ ¾
5167 513 v1.2
*1 When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump.
The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under “Recovery”.
Please also refer to the corresponding sizing chart at the end of this manual.
*2 Measured values are based on a room temperature of 68°F / 20 ºC and a domestic hot water temperature of 149°F / 65 ºC and can
vary by 5%.
4
Technical Data
DHW and
Overall height
CA TPV
AQ
IO BWS
4¼” / 109 mm
BWR
DCW
1½” /
12¼” / 311 mm
13¼” / 336 mm
18” / 459 mm
Overall width a 36 mm 1½” / 37 mm 2½” / 63 mm
Overall length
4¾” / 119 mm
6½” / 167 mm
Legend
Dimensions AQ Aquastat Well
BWR Boiler Water Return
Storage USG 42 53
BWS Boiler Water Supply
capacity ltr 160 200
CA Consumable Anode
a inches 34 40½ DCW Domestic Cold Water
mm 866 1030 DHW Domestic Hot Water
b inches 9¾ 11¾ IO Inspection and Clean-out Opening
mm 250 300 TPV Temperature and Pressure Relief Valve
5167 513 v1.2
5
Technical Data
Pressure drop on heating water side Pressure drop on domestic hot water side
(primary circuit) (secondary circuit)
“ w.c.
“ w.c.
mbar
mbar
400 1000 40 100
320 800 32 80
240 600 24 60
200 500 20 50
160 400 16 40
12 30
120 300
8 20
80 200
4 10
40 100 3.2 8
32 80 Pressure drop 2.4 6
24 60 2 5
20 50 1.6 4
16 40 1.2 3
8 10 13 17 33 50 67 83 100 133 167 ltr/min
12 30
2 3 5 3 9 13 18 22 26 35 44 GPM
8 20
Waterflow
4 10
3.2 8
Pressure drop
2.4 6
2 5
1.6 4
1.2 3
44 10 000
1 000
2 000
3 000
4 000
5 000
6 000
8 000
500
600
800
ltr/h
GPM
13
18
22
26
35
2.2
2.6
3.5
4.4
Waterflow
6
Product Installation
Standard Equipment
Steel domestic hot water storage tank with The following are packed separately and
two-coat enamel finish, mounted attached to the crate:
polyurethane foam insulation and – installation fittings package: with the
electrostatically powder coated sheet metal necessary brass couplings, adaptors, other
enclosure panel in a vitosilver finish with... necessary hardware, and hemp
– preinstalled consumable anode – temperature and pressure relief valve
– integrated thermometer and – sensor well with insulation
– adjustable leveling feet. – thermometer
– Installation, Operating, Start-up and
Service Instructions
Product Installation
IMPORTANT
This is a simplified conceptual drawing only!
Piping and necessary componentry must be
field verified. Proper installation and
functionality in the field are the
responsibility of the heating contractor.
7
Product Installation
Sensor Well
IMPORTANT
Vitocell-H 100,
The Vitocell-H 100 tank is approved for with 42 and 53 USG / 160 and 200 ltr WARNING
heating systems with a maximum DHW capacity
To ensure optimum, safe operation,
supply of up to 150 °F / 65.6 °C only.
the supplied stainless steel well must
AF 24
be installed. The well diameter is
large enough to accommodate a wide
ID 19.2
ID 15
variety of sensing bulbs.
220
½’’ Always use spring clip to ensure
proper contact of capillary bulb
against the stainless steel well for
proper sensing/heat transfer!
8
Vitocell-H 100 Sizing
Continuous Flow Capacity Chart
Vitocell-H 100,
42 USG / 160 ltr capacity
Curve
Domestic hot water 40 to 113°F / 4 to 45°C
Curve
Domestic hot water 40 to 140°F / 4 to 60°C
5167 513 v1.2
9
Vitocell-H 100 Sizing
Continuous Flow Capacity Chart
Vitocell-H 100,
53 USG / 200 ltr capacity
Curve
Domestic hot water 40 to 113°F / 4 to 45°C
Curve
Domestic hot water 40 to 140°F / 4 to 60°C
10
Vitocell-H 100 Sizing
Continuous Flow Capacity Chart
Assume boiler output to tank is 119 MBH. Enter chart at left and draw horizontal line across to recovery rate of 142 GPH / 2.4 GPM for
140°F / 60°C domestic hot water under column B. Where the horizontal line intersects the 194°F / 90°C curve is the point of intersection
for the diagonal line used to size the pump. The diagonal line begins at the origin and goes through the point of intersection extending up to
the top of the chart. Read between the reference diagonal lines to get a pump specification of 8.4 GPM at 1.7 ft. To summarize: For a
Vitocell-H 100 with 53 USG / 200 ltr capacity and 119 MBH input, the boiler water temperature is 194°F / 90°C, difference between
boiler return and supply water temperature is 30°F / 16.5°C, recovery rate is 2.4 GPM of 140°F / 60°C DHW, and the pump required is
8.4 GPM, 1.7 ft. plus pressure drop in piping and boiler.
5167 513 v1.2
11
Printed on environmentally friendly
(recycled and recyclable) paper.
Technical information subject to change without notice
5167 513 v1.2