Anda di halaman 1dari 7

Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

SUMMARY REPORT

Design Code Used: ACI 318-11


__________________________________________________________________________________________________________________________________

CONCRETE MATERIAL PROPERTIES


Precast Beam Cast-in-Place Pour
___________________________ ___________________________
Concrete Density Wt = 2400 kg/m^3 Wt = 2400 kg/m^3
Compressive Strength f'c = 48.0 MPa f'c = 28.0 MPa
Modulus of Elasticity Ec = 34816 MPa Ec = 26591 MPa
Strength at Transfer f'c = 35.0 MPa
Modulus of Elast. at Transfer Ec = 29730 MPa
Strength at Lifting f'c = 35.0 MPa
Modulus of Elast. at Lifting Ec = 29730 MPa
Cement Content = 410 kg/m^3 Construction Schedule
Air Content = 5.00 % Age at Transfer = 0.75 days
Slump = 50.0 mm Age at Erection = 40 days
Aggregate Mix = 0.40 (fine to total aggregate ratio) Age at Cast-in-Place Pour = 50 days
Aggregate Size = 20.0 mm Age Cast-in-Place is Composite = 53 days
Basic Shrinkage Strain = 780.000E-6 Age Construction is Complete = 143 days

Curing Method = Moist


Relative Humidity in Service = 70 %
Ambient Temperature in Service = 20 deg C
__________________________________________________________________________________________________________________________________

PRECAST BEAM LAYOUT

________________________________________________________________________________________________________________
| Segment/Length | Section Identification | Offset |
|No| From | To | Length | Folder | Section | Section | Z | Y |
| | m | m | m | Name | Name | Type | mm | mm |
________________________________________________________________________________________________________________
| 1| 0.000| 9.600| 9.600| Inverted-Tee | INVERT T | Inverted Tee | 0.0| 0.0|
________________________________________________________________________________________________________________

Span Length at Transfer = 9.000 m, Centre of Supports, Left @ 0.300 m, Right @ 9.300 m
Span Length in Service = 9.370 m, Centre of Supports, Left @ 0.115 m, Right @ 9.485 m
Total Beam Length = 9.600 m, Bearing Length, Left = 230.0 mm, Right = 230.0 mm

Beam is shored during cast-in-place pour.


CAST-IN-PLACE POUR LAYOUT

______________________________________________________________________________________________
| Segment/Length | Slab/Topping Parameters | Haunch Paramaters |Vertical|
|No| From | To | Length | Thick. | Width | Offset | Thick. | Width | Offset | Offset |
| | m | m | m | mm | mm | mm | mm | mm | mm | mm |
______________________________________________________________________________________________
| 1| 0.000| 9.600| 9.600| 100.0| 1400.0| 0.0| 60.0| 300.0| 0.0| 0.0|
______________________________________________________________________________________________
The beam is SHORED during the cast-in-place pour for the weight of the dead load applied before the cast-in-place pour, and the cast-in-pla

__________________________________________________________________________________________________________________________________

GROSS PRECAST SECTION PROPERTIES (NON-COMPOSITE)


(based on Ec of the precast beam - transformed area of rebar and strand NOT included)

_______________________________________________________________________________________________________
|Seg.| Section Properties | Section| Section| Shear |Volume /| Section Moduli |
| No.| A | I | yb | Height | Width | Width | Surface| Sb | St |
| | mm^2 | mm^4 | mm | mm | mm | mm | mm | mm^3 | mm^3 |
_______________________________________________________________________________________________________
| 1| 375000 | 13.254E+9 | 317.0| 700.0| 600.0| 300.0| 144.00| -41.811E+6 | 34.606E+6 |
_______________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________
GROSS COMPOSITE SECTION PROPERTIES
(based on Ec of the precast beam - transformed area of rebar and strand NOT included)

______________________________________________________________________________________________________
|Seg.| Section Properties | Section| Section Moduli |
| No.| Ac | Ic | yb | Height | Sb | St | Sbc | Stc |
| | mm^2 | mm^4 | mm | mm | mm^3 | mm^3 | mm^3 | mm^3 |
______________________________________________________________________________________________________
| 1| 495674 | 34.802E+9 | 434.8| 860.0| -80.040E+6 | 131.230E+6 | 131.230E+6 | 81.849E+6 |
______________________________________________________________________________________________________

Note: Sb & St = bottom and top of the precast beam, Sbc & Stc = bottom and top of the cast-in-place pour.

__________________________________________________________________________________________________________________________________
UNCRACKED SECTION PROPERTIES SUMMARY
__________________________________________________________________________________________________________________________________
| | Net Precast Section | Transformed Precast Section | Transformed Precast Section |Transformed Composite Section|
| | at Transfer (based on Eci) | at Transfer (based on Eci) | in Service (based on Ec) | in Service (based on Ec) |
| |(include rebar,deduct strand)| (include rebar and strand) | (include rebar and strand) | (include rebar and strand) |
| x | A | I | yb | A | I | yb | A | I | yb | Ac | Ic | ybc |
| m | mm^2 | mm^4 | mm | mm^2 | mm^4 | mm | mm^2 | mm^4 | mm | mm^2 | mm^4 | mm |
__________________________________________________________________________________________________________________________________
| 0.000| 373072 | 13.184E+9 | 318.0| 375058 | 13.257E+9 | 317.0| 375048 | 13.257E+9 | 317.0| 495724 | 34.806E+9 | 434.8|
| 0.115| 384470 | 13.825E+9 | 317.4| 388462 | 13.979E+9 | 315.4| 386152 | 13.855E+9 | 315.7| 507733 | 35.815E+9 | 431.9|
| 0.865| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 1.802| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 2.739| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 3.676| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 4.050| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 4.613| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 4.800| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 4.987| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 5.550| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 5.924| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 6.861| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 7.798| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 8.735| 419416 | 15.885E+9 | 314.2| 432696 | 16.387E+9 | 308.4| 422796 | 15.854E+9 | 309.7| 546331 | 39.155E+9 | 420.9|
| 9.485| 384470 | 13.825E+9 | 317.4| 388462 | 13.979E+9 | 315.4| 386152 | 13.855E+9 | 315.7| 507733 | 35.815E+9 | 431.9|
| 9.600| 373072 | 13.184E+9 | 318.0| 375058 | 13.257E+9 | 317.0| 375048 | 13.257E+9 | 317.0| 495724 | 34.806E+9 | 434.8|
__________________________________________________________________________________________________________________________________

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 1 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

These section properties can used to calculate uncracked concrete stresses using the following guidelines.

Net Precast Section at Transfer properties are used with the initial prestress after transfer (after elastic shortening loss).
Transformed Precast Section at Transfer properties are used with the precast beam self-weight.
Transformed Precast Section in Service properties are used with external loads applied to the non-composite precast beam.
Transformed Composite Section in Service properties are used with external loads applied to the composite precast beam.
__________________________________________________________________________________________________________________________________

PRESTRESSING STEEL TENDONS


__________________________________________________________________________________________________________
| | | | | | Offsets |End Offset & Type| Tendon | Jacking Force |
|ID|Qty| Grade |Type| Strand Size | x | y |Left **|Right **| Area | Pj | %fpu|
| | | MPa | * | | m | mm | m | m | mm^2 | kN | |
__________________________________________________________________________________________________________
| 1| 5| 1860| LRS| 12.7 (1/2") | 0.000| 50.0| 0.000 B| 0.000 B| 493.50 | 648.1 | 0.71|
| | | | | | 9.600| 50.0| | | | | |
| 2| 5| 1860| LRS| 12.7 (1/2") | 0.000| 100.0| 0.000 B| 0.000 B| 493.50 | 648.1 | 0.71|
| | | | | | 9.600| 100.0| | | | | |
| 3| 5| 1860| LRS| 12.7 (1/2") | 0.000| 150.0| 0.000 B| 0.000 B| 493.50 | 648.1 | 0.71|
| | | | | | 9.600| 150.0| | | | | |
| 4| 5| 1860| LRS| 12.7 (1/2") | 0.000| 200.0| 0.000 B| 0.000 B| 493.50 | 648.1 | 0.71|
| | | | | | 9.600| 200.0| | | | | |
__________________________________________________________________________________________________________
Some strand groups are inactive.

note: * Type = LRS - Low-Relaxation Strand, SRS - Stress-Relieved Strand, PB - Plain Bar,
DB - Deformed Bar, SW - Single Wire
** End Types = B - Fully Bonded, D - Debonded, C - Cut, A - Anchored (fully developed)
Calculated Losses: Initial = 5.3%, Final = 6.6%
Maximum Total Prestress Forces: Pj(jacking) = 2592.5 kN,
Pi(transfer) = 2455.5 kN,
Pe(effective) = 2422.4 kN @ x = 4.800 m,
See the "Development Length" text report for details of the strand transfer and development lengths

__________________________________________________________________________________________________________________________________

LONGITUDINAL REINFORCING STEEL

Reinforcing Steel Groups


___________________________________________________________________________________________________________________
|ID|Qty| Steel | Bar | Bar |End Location & Type| Bar | | Cross |Vertical| Offset ** |
| | | Grade | Size | Area | From | | To | | Spacing| | Spacing| Offset | Reference |
| | | MPa | | mm^2 | m | *| m | *| mm | | mm | mm | |
___________________________________________________________________________________________________________________
| 1| 4| 415 | 25mm | 1960 | 0.000|SE| 9.600|SE| 100.0| | - | 50.0| Bottom of Precast Beam |
| 2| 4| 415 | 25mm | 1964 | 0.000|SE| 9.600|SE| 100.0| | - | 100.0| Bottom of Precast Beam |
| 3| 2| 415 | 20 | 630 | 0.000|SE| 9.600|SE| 100.0| | - | 150.0| Bottom of Precast Beam |
| 4| 3| 415 | 20 | 942 | 0.000|SE| 9.600|SE| 100.0| | - | 50.0| Top of Precast Beam |
| 5| 3| 415 | 16 | 603 | 0.000|SE| 9.600|SE| 200.0| | - | 30.0|Top of Cast-in-Place Pour|
| 6| 4| 415 | 20 | 1260 | 0.000|SE| 9.600|SE| 100.0| | - | 500.0| Bottom of Precast Beam |
| 8| 2| 415 | 16 | 402 | 0.000|SE| 9.600|SE| 200.0| | - | 250.0| Bottom of Precast Beam |
| 9| 3| 415 | 20 | 942 | 0.000|SE| 9.600|SE| 100.0| | - | 100.0| Top of Precast Beam |
___________________________________________________________________________________________________________________
Some reinforcing groups are inactive.

* End Types: SE - Straight Embeddment, FD - Fully Developed, SH - Standard Hook, HB - Headed Bar
** Offsets are measured up from the bottom or down from the top

See the "Development Length" text report for details of the bar and wire development lengths

__________________________________________________________________________________________________________________________________

SHEAR STIRRUPS

_______________________________________________________________________________________________________
| | | Stirrup| Stirrup| Number of Legs | Total Stirrup Area | Stirrup Spacing |
| From | To | Grade | Size | Stirrup |Interface| Stirrup | Interface | Stirrup |Interface|
| m | m | MPa | | in Beam | Ties | mm^2 | mm^2 | mm | mm |
_______________________________________________________________________________________________________
| 0.000| 2.000| 415| 32mm | 4| 2| 3219.5 | 1609.7 | 50.0| 50.0|
| 2.000| 7.550| 500| 12mm | 4| 2| 452.4 | 226.2 | 100.0| 100.0|
| 7.550| 9.600| 415| 32mm | 4| 2| 3219.5 | 1609.7 | 50.0| 50.0|
_______________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________

TORSION PARAMETERS

Seg. Torsion Parameters


_____________________________________
|No.| Aoh | Ph |
| | mm^2 | mm |
_____________________________________
| 1| 0.0 | 0.0 |
_____________________________________

Aoh is the area enclosed by the centerline of the outermost closed transverse torsional reinforcement.
Ph is the perimeter of the area defined as Aoh.

__________________________________________________________________________________________________________________________________

PRECAST BEAM AND CAST-IN-PLACE POUR SELF-WEIGHT

____________________________________________________
| Segment/Length | Linear Weight |
| | From | To | Beam | Cast-in-Place |
|No.| m | m | kN/m | kN/m |
____________________________________________________
| 1| 0.000| 9.600| 8.8254 | 3.7184 |
____________________________________________________
__________________________________________________________________________________________________________________________________

EXTERNALLY APPLIED LOADS


________________________________________________________________________________________________________________
| Load Case |Type| Label | Description | Distribution |
________________________________________________________________________________________________________________
|SDL BT | D |SS200 |Vertical: 35.8 to 38.8 kN/m full length |No Load Distribution|

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 2 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

|SDL AT | D |SIDL |Vertical: 17.9 kN/m full length |No Load Distribution|
|SDL AT | D |machine |Vertical: 107.5 kN/m full length |No Load Distribution|
|Live Load | L |LL |Vertical: 21.5 kN/m full length |No Load Distribution|
________________________________________________________________________________________________________________
Some applied loads are inactive.

Load Combinations
Factored Combination 1 = 1.40D + 1.40F
Factored Combination 2 = 1.20D + 1.60L + 0.50SRLr + 1.20F
Factored Combination 3 = 1.20D + 1.00L + 1.60SRLr + 1.20F
Factored Combination 4 = 1.20D + 1.60SRLr + 1.20F + 0.50W
Factored Combination 5 = 1.20D + 1.00L + 0.50SRLr + 1.20F + 1.00W
Factored Combination 6 = 1.20D + 1.00L + 0.50SRLr + 1.20F + 1.00W
Factored Combination 7 = 0.90D + 1.00W
Factored Combination 8 = 0.90D + 0.90F + 1.00E
Factored Combination 9 =

__________________________________________________________________________________________________________________________________
ANALYSIS RESULTS SUMMARY - IN SERVICE

__________________________________________________________________________________________
| | Total Unfactored Moments| Total Factored Effects |
| x | Total | Sustained | Shear | | Moment | | Torsion | |
| m | kNm | kNm | kN | [*]| kNm | [*]| kNm | [*]|
__________________________________________________________________________________________
| 0.000| 0.0 | 0.0 | 0.0 |[ 1]| 0.0 |[ 1]| 0.0 |[ 1]|
| 0.115| -1.3 | -1.1 | -28.0 |[ 1]| -1.6 |[ 1]| 0.0 |[ 1]|
| 0.115| -1.3 | -1.1 | 1146.2 |[ 1]| -1.6 |[ 1]| 0.0 |[ 1]|
| 0.865| 633.0 | 563.7 | 963.7 |[ 1]| 789.2 |[ 1]| 0.0 |[ 1]|
| 1.802| 1271.5 | 1132.3 | 735.3 |[ 1]| 1585.2 |[ 1]| 0.0 |[ 1]|
| 2.739| 1738.0 | 1547.8 | 506.4 |[ 1]| 2167.0 |[ 1]| 0.0 |[ 1]|
| 3.676| 2032.3 | 1810.1 | 277.2 |[ 1]| 2534.1 |[ 1]| 0.0 |[ 1]|
| 4.050| 2101.8 | 1872.0 | 185.4 |[ 1]| 2620.8 |[ 1]| 0.0 |[ 1]|
| 4.613| 2154.2 | 1918.8 | 47.6 |[ 1]| 2686.3 |[ 1]| 0.0 |[ 1]|
| 4.800| 2157.9 | 1922.1 | 1.6 |[ 1]| 2690.9 |[ 1]| 0.0 |[ 1]|
| 4.987| 2154.6 | 1919.2 | -44.5 |[ 2]| 2686.9 |[ 1]| 0.0 |[ 1]|
| 5.550| 2103.4 | 1873.7 | -182.4 |[ 1]| 2623.1 |[ 1]| 0.0 |[ 1]|
| 5.924| 2034.7 | 1812.5 | -274.5 |[ 1]| 2537.5 |[ 1]| 0.0 |[ 1]|
| 6.861| 1741.8 | 1551.6 | -505.1 |[ 1]| 2172.3 |[ 1]| 0.0 |[ 1]|
| 7.798| 1275.5 | 1136.3 | -736.0 |[ 1]| 1590.9 |[ 1]| 0.0 |[ 1]|
| 8.735| 635.7 | 566.4 | -967.3 |[ 1]| 792.9 |[ 1]| 0.0 |[ 1]|
| 9.485| -1.3 | -1.2 | -1152.6 |[ 1]| -1.6 |[ 1]| 0.0 |[ 1]|
| 9.485| -1.3 | -1.2 | 28.5 |[ 1]| -1.6 |[ 1]| 0.0 |[ 1]|
| 9.600| 0.0 | 0.0 | 0.0 |[ 1]| 0.0 |[ 1]| 0.0 |[ 1]|
__________________________________________________________________________________________

* Critical ULS Load Combination


__________________________________________________________________________________________________________________________________

SUPPORT REACTIONS (kN)


(+ve = upwards)

Unfactored Support Reactions


___________________________________________________________________________________________
| | In Service | During Lifting | During Transport |
| Load Case | Left | Right | Left | Right | Left | Right |
___________________________________________________________________________________________
|Beam Weight| 42.4 | 42.4 | 42.4 | 42.4 | 42.4 | 42.4 |
|SDL BT | 176.6 | 181.5 | | | | |
|CIP Weight | 17.8 | 17.8 | | | | |
|SDL AT | 601.9 | 601.9 | | | | |
|LL Sustain | 0.0 | 0.0 | | | | |
|Live Load | 103.2 | 103.2 | | | | |
|Roof Load | 0.0 | 0.0 | | | | |
|Fluid Wgt | 0.0 | 0.0 | | | | |
|Wind | 0.0 | 0.0 | | | | |
|Seismic | 0.0 | 0.0 | | | | |
|Constrct LL| 0.0 | 0.0 | | | | |
___________________________________________________________________________________________
|SLS Maximum| 941.9 | 946.8 | 42.4 | 42.4 | 42.4 | 42.4 |
|SLS Max DL | 838.7 | 843.6 | | | | |
|SLS Min DL | 838.7 | 843.6 | | | | |
|SLS Max Sus| 838.7 | 843.6 | | | | |
___________________________________________________________________________________________

ULS Support Reactions


_________________________________________________
|Load Combo.| Left [*]| Right [*]|
_________________________________________________
|ULS Maximum| 1174.2 [ 1]| 1181.1 [ 1]|
|ULS Minimum| 754.8 [ 7]| 759.3 [ 7]|
_________________________________________________

* Critical Factored Load Combination


__________________________________________________________________________________________________________________________________

CONCRETE STRESS RESULTS (UNCRACKED ANALYSIS)


(+ve = compression, -ve = tension)
The beam is SHORED during the cast-in-place pour for the weight of the dead load applied before the cast-in-place pour, and the cast-in-pla
_________________________________________________________________
| | x | Stress | Limit | Overstress|
| Location | m | MPa | MPa | Notice |
_________________________________________________________________
|STRESSES AT TRANSFER |
|Critical Compression |
| Top of Beam | 0.000| 0.00 | 24.50 | 0%|
| Bottom of Beam | 1.333| 14.32 | 21.00 | 0%|
| | Longitudinal Tensile Rebar Needed (mm^2)
|Critical Tension | Required Provided Additional
| Top of Beam | 8.923| -5.07 | -2.95 | 72%| 703 1884 0
| Bottom of Beam | 0.000| 0.02 | -2.95 | 0%|
_________________________________________________________________
|STRESSES DURING INITIAL LIFTING |
|Critical Compression |
| Top of Beam | 0.000| 0.00 | 24.50 | 0%|
| Bottom of Beam | 1.333| 14.08 | 21.00 | 0%|
| | Longitudinal Tensile Rebar Needed (mm^2)
|Critical Tension | Required Provided Additional
| Top of Beam | 8.923| -4.76 | -2.95 | 62%| 633 1884 0

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 3 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

| Bottom of Beam | 0.000| 0.02 | -2.95 | 0%|


_________________________________________________________________
|STRESSES DURING ERECTION LIFTING |
|Critical Compression |
| Top of Beam | 0.000| 0.00 | 33.60 | 0%|
| Bottom of Beam | 8.267| 13.81 | 28.80 | 0%|
| | Longitudinal Tensile Rebar Needed (mm^2)
|Critical Tension | Required Provided Additional
| Top of Beam | 8.923| -4.66 | -3.45 | 35%| 626 1884 0
| Bottom of Beam | 0.000| 0.02 | -3.45 | 0%|
_________________________________________________________________
|STRESSES IN SERVICE |
|Critical Compression |
| Top of Beam | 4.800| 11.65 | 28.80 | 0%|
| Bottom of Beam | 0.677| 7.80 | 28.80 | 0%|
| Top of CIP Pour| 4.800| 17.65 | 16.80 | 5%|
|Critical Tension |
| Top of Beam | 0.630| -1.02 | -6.90 |* 0%| Class U member - not cracked
| Bottom of Beam | 4.800| -9.14 | -6.90 |* 32%| Class C member - check cracking and cover
| Top of CIP Pour| 9.485| -0.01 | -3.30 |* 0%|
_________________________________________________________________
|STRESSES IN SERVICE (SUSTAINED LOADS ONLY) |
|Critical Compression |
| Top of Beam | 4.800| 9.97 | 21.60 | 0%|
| Bottom of Beam | 0.677| 8.37 | 21.60 | 0%|
_________________________________________________________________
* Tensile stress limit given is for Class T (controlled cracking). Beyond this limit crack control is required.
Tensile stress limit given for the cast-in-place pour is the flexural cracking strength of the concrete.

At Transfer During Lifting In Service


Modulus of Rupture, fr = -3.68 MPa -3.68 MPa -4.31 MPa
Strength Required for Transfer, f'c = 23.9 MPa (f'c specified = 35 MPa)
Strength Required for Initial Lifting, f'c = 23.5 MPa (f'c assumed = 35 MPa)
__________________________________________________________________________________________________________________________________

DISTRIBUTION OF FLEXURAL STEEL & CRACKING


(+ve = tension, -ve = compression)
The beam is SHORED during the cast-in-place pour for the weight of the dead load applied before the cast-in-place pour, and the cast-in-pla

Maximum Crack Width Estimate


________________________________________
|Cracking | Bottom | Top of |
|at | of Beam | CIP Pour |
________________________________________
| Cracked? | Yes | No |
| Before CIP?| Yes | No |
| w =| 0.114 | 0.000 | mm - Estimated maximum crack width *
| x =| 4.800 | 0.000 | m - Location of maximum crack width from left end of beam
| c =| 399.3 | 0.0 | mm - Concrete depth in compression
| Ms =| 2157.9 | 0.0 | kNm - External service moment (DL + LL)
| Pdc =| -2665.1 | 0.0 | kN - Decompression force at cracked centroid
| Mint=| 871.1 | 0.0 | kNm - Internal moment about cracked centroid
| Steel| mixed | rebar | - Type of steel in tension
| Method| Suri&Dilger| - | - Equation used **
| k1 =| 3.0 | 0.0 | - (x 10^-6) Coefficient used for equation
| fs =| 120 | 0 | MPa - Stress in steel nearest to tension face (after decompression)
| h1 =| - | 0.0 | mm - Distance from the NA to the extreme rebar (Gergely & Lutz)
| h2 =| - | 0.0 | mm - Distance from the NA to the edge of concrete in tension (Gergely & Lutz)
| dc =| 50.0 | 0.0 | mm - Concrete cover to center of steel closest to tension face
| A =| - | 0 | mm^2 - Area of concrete in tension around each bar/strand (Gergely & Lutz)
| At =| 276400 | 0 | mm^2 - Area of concrete in tension (Suri & Dilger)
| As =| 6930 | 0 | mm^2 - Area of steel in tension (Suri & Dilger)
| cc =| 37.5 | 0.0 | mm - Clear concrete cover to steel closest to tension face
| s =| 697.9 | 0.0 | mm - Maximum centre-to-centre spacing of steel closest to tension face
| fc =| -17.36 | 0.00 | MPa - Maximum concrete compressive stress - opposite face to cracking
| limit=| -16.80 | -28.80 | MPa - Allowable concrete compressive stress
________________________________________
Recommended Crack Width (mm) and Equivalent z (N/mm) Values (from PCI Design Handbook)
____________________________________________________________________________________________
| | Critical | Prestressed | Reinforced |
| | Exposure | Concrete | Concrete |
| | w | z | w | z | w | z |
____________________________________________________________________________________________
|Exterior Exposure | 0.178| 14010| 0.203| 15761| 0.330| 25393|
|Interior Exposure | 0.254| 18388| 0.279| 20140| 0.406| 30647|
____________________________________________________________________________________________

* Note: actual crack widths can vary by as much as 50% from this estimated value.
Control of cracking is accomplished by proper steel detailing as specified in the design code.
** Note: Gergely & Lutz equation: w = k1 x fs x h2 / h1 x CubicRoot(dc * A)
Suri & Dilger equation: w = k1 x fs x dc x Sqrt(At / Ast)

__________________________________________________________________________________________________________________________________
DEFLECTION ESTIMATE AT ALL STAGES
Design Code Used: ACI 318-11
The beam is SHORED during the cast-in-place pour for the weight of the dead load applied before the cast-in-place pour, and the cast-in-pla

A. Deflections at All Stages


(-ve = deflection down, +ve = camber up)
_____________________________________________________________________________________________________________
| | Net Deflection | Change in Deflection |
|Location| Net @ | Net @ | Net @ | Net DL | Net Total| DL growth| LL | Span/Deflection |
| x | Transfer | Erection |Completion| @ Final | @ Final | + LL | alone | DL growth| LL |
| m | mm | mm | mm | mm | mm | mm | mm | + LL | alone |
| Column | A | B | C | D | E | E - C | E - D | | |
_____________________________________________________________________________________________________________
| 0.000| -1.1 | -0.3 | 0.1 | 0.4 | 0.5 | 0.4 | 0.1 | 584 | 2176 |
| 0.115| -0.7 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0 | 0 |
| 0.865| 2.0 | 1.6 | -1.0 | -2.8 | -3.5 | -2.5 | -0.7 | 3691 | 13707 |
| 1.802| 4.7 | 2.9 | -2.6 | -6.6 | -8.1 | -5.5 | -1.5 | 1705 | 6265 |
| 2.739| 6.7 | 3.6 | -4.2 | -10.0 | -12.2 | -8.0 | -2.2 | 1175 | 4222 |
| 3.676| 7.9 | 4.0 | -5.6 | -12.5 | -15.3 | -9.7 | -2.8 | 961 | 3383 |
| 4.050| 8.2 | 4.1 | -5.9 | -13.2 | -16.1 | -10.2 | -2.9 | 920 | 3224 |
| 4.613| 8.4 | 4.1 | -6.2 | -13.7 | -16.7 | -10.5 | -3.0 | 890 | 3112 |
| 4.800| 8.4 | 4.1 | -6.2 | -13.7 | -16.7 | -10.5 | -3.0 | 888 | 3105 |

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 4 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

| 4.987| 8.4 | 4.1 | -6.2 | -13.7 | -16.7 | -10.5 | -3.0 | 890 | 3112 |
| 5.550| 8.2 | 4.1 | -5.9 | -13.2 | -16.1 | -10.2 | -2.9 | 919 | 3223 |
| 5.924| 7.9 | 4.0 | -5.6 | -12.5 | -15.3 | -9.7 | -2.8 | 961 | 3382 |
| 6.861| 6.7 | 3.6 | -4.3 | -10.0 | -12.2 | -8.0 | -2.2 | 1174 | 4219 |
| 7.798| 4.7 | 2.8 | -2.6 | -6.6 | -8.1 | -5.5 | -1.5 | 1703 | 6260 |
| 8.735| 2.0 | 1.6 | -1.0 | -2.8 | -3.5 | -2.5 | -0.7 | 3686 | 13695 |
| 9.485| -0.7 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0 | 0 |
| 9.600| -1.1 | -0.3 | 0.1 | 0.4 | 0.5 | 0.4 | 0.1 | 584 | 2175 |
_____________________________________________________________________________________________________________

Col. A: Net deflection at transfer includes prestressing and beam weight on temporary supports.
Col. B: Net deflection at erection includes prestressing and all dead loads applied before the cast-in-place
pour plus long-time deflection growth of the prestressing and beam weight up to erection
Col. C: Net deflection at completion of construction includes prestressing and all dead loads
plus long-time deflection growth of the prestressing and dead load up to completion
Col. D: Net DL deflection at final includes prestressing, all dead loads, and sustained live loads,.
plus long-time deflection growth.
Col. E: Net total deflection at final includes prestressing, all dead loads, and all live loads,
plus long-time deflection growth.
Live load includes roof load, and fluid weight. Wind and earthquake are not included.
Deflection growth is estimated by use of the PCI suggested multipliers - see the Deflection Multipliers report.

Span/Deflection Limits: DL growth + LL = L / 480 for non-structural attachments


L / 240 otherwise
LL alone = L / 360 for floors
L / 180 for roofs
__________________________________________________________________________________________________________________________________

SUPPORT ROTATIONS, AND CHANGE OF LENGTH AT ALL STAGES


Design Code Used: ACI 318-11

B. Unrestrained Support Rotations at All Stages


(-ve = counter-clockwise rotation, +ve = clockwise rotation)
_____________________________________________________________________________________________________
| | Net Rotation | Change in Rotation |
| Support| Net @ | Net @ | Net @ | Net DL | Net Total | DL growth | LL |
|Location| Transfer | Erection | Completion | @ Final | @ Final | + LL | alone |
| | degrees | degrees | degrees | degrees | degrees | degrees | degrees |
| Column | A | B | C | D | E | E - C | E - D |
_____________________________________________________________________________________________________
| Left | -0.2195 | -0.1314 | 0.0622 | 0.2054 | 0.2580 | 0.1959 | 0.0526 |
| Right | 0.2195 | 0.1308 | -0.0629 | -0.2063 | -0.2590 | -0.1961 | -0.0527 |
_____________________________________________________________________________________________________

C. Unrestrained Longitudinal Change of Length Due to Creep and Shrinkage


(-ve = shortening, +ve = elongation)

Elastic Shortening = -1.76 mm


__________________________________________________________________________________________________
| | Total Change of Length (after elastic shortening) | Difference in Change |
| | | Erection |Completion| Final | | to Compl.| to Final | to Final |
| | | mm | mm | mm | | mm | mm | mm |
| | | B | C | D | | C - B | D - C | D - B |
__________________________________________________________________________________________________
| Creep | | -0.41| -0.85| -2.86| | -0.44| -2.01| -2.45|
| Shrink.| | -0.59| -1.31| -3.18| | -0.72| -1.86| -2.59|
| Total | | -1.00| -2.16| -6.04| | -1.17| -3.88| -5.04|
__________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________

FLEXURAL DESIGN CHECK

Design Code Used: ACI 318-11


β used: for precast beam = 0.702 , for cast-in-place pour = 0.847

Modulus of Rupture of Precast Concrete, fr = 4.31 MPa (tension)


______________________________________________________________________________________________________________________
| | Factored | Design | Cracking | Minimum | Depth in | Net Tensile| Flexural | Ø | Notes & |
| | Moment | Strength | Moment | Required | Compression| Strain |Classication| | Warnings |
| x | Mu | ØMn | Mcr | Strength | c | | | | |
| m | kNm | kNm | kNm | kNm | mm | | | | |
______________________________________________________________________________________________________________________
| 0.000| 0.0 | 2.3 | 346.6 | 0.0 | 279.8 | 0.0000|Tension | 0.82| |
| 0.115| -1.6 | -182.0 | 275.7 | -3.2 | 214.7 | 0.0007|Tension | 0.90| 5|
| 0.865| 789.2 | 2554.5 | 1623.3 | 1578.4 | 252.3 | 0.0066|Tension | 0.84| |
| 1.802| 1585.2 | 3098.9 | 1659.2 | 1991.1 | 310.8 | 0.0048|Transition | 0.88| |
| 2.739| 2167.0 | 3118.0 | 1685.5 | 2022.6 | 317.4 | 0.0047|Transition | 0.87| |
| 3.676| 2534.1 | 3118.5 | 1702.1 | 2042.6 | 317.8 | 0.0046|Transition | 0.87| |
| 4.050| 2620.8 | 3119.1 | 1706.1 | 2047.3 | 317.8 | 0.0046|Transition | 0.87| |
| 4.613| 2686.3 | 3119.5 | 1709.1 | 2050.9 | 317.8 | 0.0046|Transition | 0.87| |
| 4.800| 2690.9 | 3119.5 | 1709.3 | 2051.1 | 317.8 | 0.0046|Transition | 0.87| |
| 4.987| 2686.9 | 3119.5 | 1709.1 | 2050.9 | 317.8 | 0.0046|Transition | 0.87| |
| 5.550| 2623.1 | 3119.1 | 1706.2 | 2047.5 | 317.8 | 0.0046|Transition | 0.87| |
| 5.924| 2537.5 | 3118.5 | 1702.4 | 2042.9 | 317.8 | 0.0046|Transition | 0.87| |
| 6.861| 2172.3 | 3118.0 | 1685.9 | 2023.1 | 317.4 | 0.0047|Transition | 0.87| |
| 7.798| 1590.9 | 3099.0 | 1659.6 | 1991.6 | 310.8 | 0.0048|Transition | 0.88| |
| 8.735| 792.9 | 2554.6 | 1623.5 | 1585.8 | 252.3 | 0.0066|Tension | 0.84| |
| 9.485| -1.6 | -182.0 | 275.7 | -3.3 | 214.7 | 0.0007|Tension | 0.90| 5|
| 9.600| 0.0 | 2.3 | 346.6 | 0.0 | 279.8 | 0.0000|Tension | 0.82| |
______________________________________________________________________________________________________________________
Points of Maximum and Minimum Factored Moment
| 4.800| 2690.9 | 3119.5 | 1709.3 | 2051.1 | 317.8 | 0.0046|Transition | 0.87| |
| 9.485| -1.6 | -182.0 | 275.7 | -3.3 | 214.7 | 0.0007|Tension | 0.90| 5|
Points of Maximum Ratio of Factored Moment to Design Strength
| 4.800| 2690.9 | 3119.5 | 1709.3 | 2051.1 | 317.8 | 0.0046|Transition | 0.87| |
| 9.485| -1.6 | -182.0 | 275.7 | -3.3 | 214.7 | 0.0007|Tension | 0.90| 5|
Points of Maximum Ratio of Minimum Strength to Design Strength
| 8.501| 1012.7 | 2691.0 | 1633.5 | 1960.2 | 266.6 | 0.0061|Tension | 0.85| |
| 9.485| -1.6 | -182.0 | 275.7 | -3.3 | 214.7 | 0.0007|Tension | 0.90| 5|
______________________________________________________________________________________________________________________

Notes & Warnings


5 - Note: The design strength is based on a reduced maximum concrete strain to avoid slippage of some strands or rebar.
See the Flexural Design Detail Report and the Help file's Technical Background for more information.
__________________________________________________________________________________________________________________________________

SHEAR DESIGN CHECK

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 5 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

Design Code Used: ACI 318-11

__________________________________________________________________________________________________________
| | Design | Prestress| Concrete | Strength Provided | Min. Strength Req'd | Notes & |
| | Shear | Component| Strength | Stirrups | Total | Stirrups | Total | Warnings |
| x | Vu | Vp | ØVc | ØVs | ØVn | ØVs | ØVn | |
| m | kN | kN | kN | kN | kN | kN | kN | |
__________________________________________________________________________________________________________
| 0.000| 0.0 | 0.0 | -356.4 | -712.4 | -1069 | 0.0 | -356.4 | 4 5 |
| 0.115| 0.0 | 0.0 | 381.6 | 712.4 | 1094 | 0.0 | 381.6 | 4 5 |
| 0.115| 1014 | 0.0 | 381.6 | 712.4 | 1094 | 631.9 | 1014 | 4 5 |
| 0.865| 963.7 | 0.0 | 592.7 | 773.4 | 1366 | 371.0 | 963.7 | 4 |
| 1.802| 735.3 | 0.0 | 543.3 | 771.1 | 1314 | 192.0 | 735.3 | 4 |
| 2.739| 506.4 | 0.0 | 295.5 | 771.6 | 1067 | 210.9 | 506.4 | 4 |
| 3.676| 277.2 | 0.0 | 166.9 | 771.5 | 938.5 | 110.3 | 277.2 | 4 |
| 4.050| 185.4 | 0.0 | 164.0 | 771.5 | 935.5 | 54.2 | 218.2 | 4 |
| 4.613| 47.6 | 0.0 | 164.0 | 771.5 | 935.5 | 0.0 | 164.0 | 4 |
| 4.800| 1.6 | 0.0 | 164.0 | 771.5 | 935.5 | 0.0 | 164.0 | 4 |
| 4.987| -44.5 | 0.0 | -164.0 | -771.5 | -935.5 | 0.0 | -164.0 | 4 |
| 5.550| -182.4 | 0.0 | -164.0 | -771.5 | -935.5 | -54.2 | -218.2 | 4 |
| 5.924| -274.5 | 0.0 | -164.9 | -771.5 | -936.5 | -109.6 | -274.5 | 4 |
| 6.861| -505.1 | 0.0 | -293.4 | -771.6 | -1065 | -211.6 | -505.1 | 4 |
| 7.798| -736.0 | 0.0 | -541.0 | -771.1 | -1312 | -195.0 | -736.0 | 4 |
| 8.735| -967.3 | 0.0 | -593.7 | -773.4 | -1367 | -373.6 | -967.3 | 4 |
| 9.485| -1018 | 0.0 | -381.6 | -712.4 | -1094 | -636.2 | -1018 | 4 5 |
| 9.485| 0.0 | 0.0 | 381.6 | 712.4 | 1094 | 0.0 | 381.6 | 4 5 |
| 9.600| 0.0 | 0.0 | 356.4 | 712.4 | 1069 | 0.0 | 356.4 | 4 5 |
__________________________________________________________________________________________________________
Notes & Warnings
4 - Note: Shear strength provided by shear steel, ØVs, is limited by maximum limit (web crushing).
5 - Note: Design shear force limited to critical section near support.
Note: The principal web stress is checked for the calculation of Vcw.
__________________________________________________________________________________________________________________________________
TORSION DESIGN CHECK

Design Code Used: ACI 318-11

_________________________________________________________________________________________
| | Design | Threshold| Combined Shear | Torsion Strength | Notes & |
| | Torsion | Torsion | and Torsion | Provided | Required | Warnings |
| x | Tu | ØTcr/4 | Stress | Limit | ØTn | ØTn | |
| m | kNm | kNm | MPa | MPa | kNm | kNm | |
_________________________________________________________________________________________
| 0.000| 0.0 | 24.0 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
| 0.115| 0.0 | 25.7 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
| 0.115| 0.0 | 25.7 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
| 0.865| 0.0 | 34.8 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 1.802| 0.0 | 35.9 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 2.739| 0.0 | 36.7 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 3.676| 0.0 | 37.2 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 4.050| 0.0 | 37.3 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 4.613| 0.0 | 37.4 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 4.800| 0.0 | 37.4 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 4.987| 0.0 | 37.4 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 5.550| 0.0 | 37.3 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 5.924| 0.0 | 37.2 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 6.861| 0.0 | 36.7 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 7.798| 0.0 | 35.9 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 8.735| 0.0 | 34.8 | 0.00 | 0.00 | 0.0 | 0.0 | |
| 9.485| 0.0 | 25.7 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
| 9.485| 0.0 | 25.7 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
| 9.600| 0.0 | 24.0 | 0.00 | 0.00 | 0.0 | 0.0 | 2 |
_________________________________________________________________________________________
Notes & Warnings
2 - Note: Design torsion force limited to critical section near support.

__________________________________________________________________________________________________________________________________
SHEAR/TORSION TRANSVERSE REINFORCING DESIGN CHECK

Design Code Used: ACI 318-11


_______________________________________________________________________________________________________________________
| | Shear Steel Required |Shear Steel| Stirrup | Stirrup Spacing | Additional Long. Steel| Notes & |
| | Total | Torsion* | Provided | Provided | Provided | Required | for Torsion, Al | Warnings |
| x | (Av+2At)/s| At/s | Av/s | Av+2At | s | s | Total |Reduction**| |
| m | mm^2/m | mm^2/m | mm^2/m | mm^2 | mm | mm | mm^2 | mm^2 | |
_______________________________________________________________________________________________________________________
| 0.000| 0 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 5 |
| 0.115| 0 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 5 |
| 0.115| 2960 | 0 | 64390 | 3219.5 | 50.0 | 304.8 | 0.0 | 0.0 | 5 6|
| 0.865| 1601 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 6|
| 1.802| 831 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 6|
| 2.739| 912 | 0 | 4524 | 452.4 | 100.0 | 496.0 | 0.0 | 0.0 | |
| 3.676| 477 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | 6|
| 4.050| 235 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | 2 6|
| 4.613| 0 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | |
| 4.800| 0 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | |
| 4.987| 0 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | |
| 5.550| 235 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | 2 6|
| 5.924| 474 | 0 | 4524 | 452.4 | 100.0 | 609.6 | 0.0 | 0.0 | 6|
| 6.861| 916 | 0 | 4524 | 452.4 | 100.0 | 494.2 | 0.0 | 0.0 | |
| 7.798| 844 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 6|
| 8.735| 1612 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 6|
| 9.485| 2981 | 0 | 64390 | 3219.5 | 50.0 | 304.8 | 0.0 | 0.0 | 5 6|
| 9.485| 0 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 5 |
| 9.600| 0 | 0 | 64390 | 3219.5 | 50.0 | 609.6 | 0.0 | 0.0 | 5 |
_______________________________________________________________________________________________________________________
Notes & Warnings
2 - Note: Amount of shear steel required represents minimum code requirements.
5 - Note: Design torsion force limited to critical section near support.
6 - Note: Required stirrup spacing represents maximum code requirements.
Note: Additional long. steel in compression side of section has been reduced.
* Portion of the total stirrup area required to resist torsional shear flow (one leg around periphery).
** The allowable reduction in Al within the flexural compression zone.
__________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________

HORIZONTAL SHEAR DESIGN CHECK BY SECTION

Design Code Used: ACI 318-11

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 6 of 7 Fri May 04 14:25:36 2018
Summary Report

Concise Beam, Version 4.59x, Copyright 2002-2016 Black Mint Software, Inc.
Licensed to: DEFAULT - FOR EVALUATION USE ONLY
Project: SBI MLVP PARKING BLOCK
Problem: INVERT T BEAM

Top of precast beam is considered intentionally roughened.

_____________________________________________________________________________________________________________
| |Horizontal| Strength | Required | Tie Size | Spacing | Spacing | Strength | Strength | Notes & |
| | Shear | with no | Ties | Provided | Required | Provided | Required | Provided | Warnings |
| x | Vu | ties | Av/s | Av | s | s | ØVnh | ØVnh | |
| m | kN | kN | mm^2/m | mm^2 | mm | mm | kN | kN | |
_____________________________________________________________________________________________________________
| 0.000| 0.0 | 93.0 | 0 | 1610 | 0.0 | 50.0 | 0.0 | 4795 | 3 |
| 0.115| 0.0 | 93.3 | 0 | 1610 | 0.0 | 50.0 | 0.0 | 4810 | 3 |
| 0.115| 1014 | 93.3 | 4336 | 1610 | 371.3 | 50.0 | 1014 | 7513 | 1 4 5|
| 0.865| 963.7 | 92.7 | 4150 | 1610 | 387.9 | 50.0 | 963.7 | 7462 | 1 4 5|
| 1.802| 735.3 | 92.4 | 3173 | 1610 | 507.2 | 50.0 | 735.3 | 7440 | 4 5|
| 2.739| 506.4 | 92.5 | 1484 | 226.2 | 152.4 | 100.0 | 506.4 | 614.3 | 4 |
| 3.676| 277.2 | 92.5 | 250 | 226.2 | 904.8 | 100.0 | 335.2 | 614.3 | |
| 4.050| 185.4 | 92.5 | 250 | 226.2 | 904.8 | 100.0 | 335.2 | 614.3 | |
| 4.613| 47.6 | 92.5 | 0 | 226.2 | 0.0 | 100.0 | 47.6 | 614.3 | 3 |
| 4.800| 1.6 | 92.5 | 0 | 226.2 | 0.0 | 100.0 | 1.6 | 614.3 | 3 |
| 4.987| -44.5 | -92.5 | 0 | 226.2 | 0.0 | 100.0 | -44.5 | -614.3 | 3 |
| 5.550| -182.4 | -92.5 | 250 | 226.2 | 904.8 | 100.0 | -335.2 | -614.3 | |
| 5.924| -274.5 | -92.5 | 250 | 226.2 | 904.8 | 100.0 | -335.2 | -614.3 | |
| 6.861| -505.1 | -92.5 | 1475 | 226.2 | 153.4 | 100.0 | -505.1 | -614.3 | 4 |
| 7.798| -736.0 | -92.4 | 3177 | 1610 | 506.7 | 50.0 | -736.0 | -7440 | 4 5|
| 8.735| -967.3 | -92.7 | 4166 | 1610 | 386.4 | 50.0 | -967.3 | -7462 | 1 4 5|
| 9.485| -1018 | -93.3 | 4354 | 1610 | 369.7 | 50.0 | -1018 | -7513 | 1 4 5|
| 9.485| 0.0 | 93.3 | 0 | 1610 | 0.0 | 50.0 | 0.0 | 4810 | 3 |
| 9.600| 0.0 | 93.0 | 0 | 1610 | 0.0 | 50.0 | 0.0 | 4795 | 3 |
_____________________________________________________________________________________________________________
Notes & Warnings
1 - WARNING: Amount of tie steel required is unattainable due to maximum limit.
3 - Note: No ties required.
4 - Note: Ties required represent minimum requirement.
5 - Note: Shear resistance based on shear friction.

__________________________________________________________________________________________________________________________________
HORIZONTAL SHEAR DESIGN CHECK BY MOMENT REGION
Design Code Used: ACI 318-11

Top of precast beam is considered intentionally roughened.


_____________________________________________________________________________________________________________________
| Region of Beam | Shear | Peak | Horizontal | Strength | Tie Area * | Tie Area | Maximum | Notes & |
| | Length | Moment | Shear | with no | Required | Provided | Spacing | Warnings |
| x | lv | M | Fh | ties | Acs | Acs | s | |
| m | m | kNm | kN | kN | mm^2 | mm^2 | mm | |
_____________________________________________________________________________________________________________________
| 0.086 to 4.800| 4.714| 2690.9 | 3996.3 | 585.0 | 11409.1 | 67946.4 | 610 | 3 |
| 4.800 to 9.514| 4.714| 2690.9 | 3996.3 | 585.0 | 11409.1 | 69443.0 | 610 | 3 |
_____________________________________________________________________________________________________________________

* Required ties should be distributed in proportion to distribution of shear force (or stirrups).

Notes & Warnings


3 - Note: Shear resistance based on shear friction.

Engineer: CNS Company: PRECA


File: main beam-grid(F1&F2)-length9.61m 7 of 7 Fri May 04 14:25:36 2018

Anda mungkin juga menyukai