SPLIT-TYPE AIR CONDITIONERS Full Product Line Catalogue 2015

NOTICE
■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Group’s environmental statement,


and expresses the Group’s stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

Wrap Yourself in Comfort and Quiet


Eco-conscious Technologies from Japan

Full Product Line Catalogue

S-179-3-C9236-B SI1403 Printed in Japan (IP)


Revised publication effective Mar. 2014.
Superseding publication of S-179-3-C9236-A Jul. 2013.
Specifications are subject to change without notice.
2015
For luxury mansion and condominium,
Maximize the comfortability with a single outdoor u
Mitsubishi Electric Inverter Multi split Systems

Space Savings Economical Operation


The Mitsubishi Electric Inverter Multi split System is designed We are able to offer industry-leading levels of energy-efficient
to allow several indoor units to be connected to a single operation for both heating and cooling with the latest innova-
outdoor unit. This enhances exterior aesthetics by reducing tive inverter technologies. Save energy and money with the
the number of outdoor units necessary, while also providing Mitsubishi Electric Inverter Multi split System.
you with an easy and economical way of adding indoor units
at any time.

1
unit,

Silent Control Flexible Choice


Comfort with less noise, based on smooth operation and Offering the ability to select up to 6 indoor units for a single
innovative features such as automatic selection of low-noise outdoor unit, Mitsubishi Electric Inverter Multi split Systems
mode when operation load is low. Choose a wall-mounted satisfy diversified needs. With the cooling capacities of
model to create a silent and comfortable space where noise outdoor units ranging from 5.0 to 12.0kW and a line up of
levels are kept low so that soothing peace and quiet can be different models to suit specific applications, you will not be
enjoyed. hard pressed to find a better match for your building dimen-
sions and comfort requirements.

2
Types of Air Conditioning Systems and
Suitable Choice for Your Home
Enhance room comfort with the air conditioner that best matches the interior.
For reliable operation and design, Mitsubishi Electric is the logical choice.

Single Split
■ Suitable for
· Small residences like studio apartments
· Homes with floor area of 20-50m2
· Installing additional units if required

Inverter Multi Split (5.0~12.0kW) CITY MULTI (12.5~25.0kW)


■ Suitable for ■ Suitable for
· Small to medium-sized residences · Large-scale residences (condominiums or leased apartments)
(condominiums or leased apartments) · Homes with floor area of 80m2 or more
· Homes with floor area of 50-100m2 · Entrance hall or penthouse
· Homes with limited space for outdoor unit installation · Using a centralized control system as integrated control of air condi-
· Increasing usable space at homes (for developers) tioning, lighting, security system and other electric appliances
· Users who prefer to keep neat appearance with ceiling-concealed · More freedom in air conditioning design due to less piping length restrictions
model · Increasing usable space in homes (for developers)
· Wide variety of indoor unit combination · Users who prefer to keep neat appearance with ceiling-concealed
model
· Wide variety of indoor unit combination

Please refer to page 50 for centralized control.

3
TABLE OF CONTENTS

INVERTER MULTI SPLIT


LINE-UP 6

INVERTER TECHNOLOGIES 7- 8

FUNCTIONS 9-14

MXY SERIES (Cooling Only) 15-24

MXZ SERIES (Heat Pump) 25-33

EXTERNAL DIMEMSIONS 34-39

PIPING INSTALLATIONS 40-41

CITY MULTI
CITY MULTI S SERIES 43-46

INDOOR UNIT LINE-UP 47-48

SYSTEM CONTROL 49-50

4
INVERTER
MULTI SPLIT
SERIES

5
LINE-UP
INVERTER Models (Cooling Only)
MXY SERIES
Capacity Class 5.0kW 7.5kW 7.5kW 9.2kW

Up to 2 indoor units Up to 3 indoor units Up to 4 indoor units Up to 4 indoor units


MXY-2E20VA MXY-3A28VA MXY-4A28VA MXY-4A38VA

Model Name

INVERTER Models (Heat Pump)


MXZ SERIES
Capacity Class 5.2kW 6.8kW 7.1kW 8.0kW 10.0kW 12.0kW

Up to 2 indoor units Up to 3 indoor units Up to 4 indoor units Up to 4 indoor units Up to 5 indoor units Up to 6 indoor units
MXZ-2C52VA MXZ-3C68VA MXZ-4C71VA MXZ-4C80VA MXZ-5C100VA MXZ-6C120VA

Model Name

Indoor Unit for MXY and MXZ


Capacity Class 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW
Model Name

MSY-E Series
MSZ-E Series

Wall-
mounted
MSY-G Series
MSZ-G Series

MLZ Series

1-way
cassette

PLA Series

4-way
cassette

SEZ Series

Celling-
concealed

6
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and low running cost — That’s the Mitsubishi Electric promise.

INVERTERS – HOW THEY WORK


Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner.
They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly
regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and
providing the most comfortable room environment.

ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced inverter technologies with cutting-edge
electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency.
Better performance and lower energy consumption are the result.

TRUE COMFORT
Simple comparison of air conditioner operation control with and without inverter

■ Inverter Operation Image (cooling mode)

Temperature (°C) Cooling capacity (W)

Point 1
When room temperature is higher than the
setting, capacity rises quickly, adjusting the
Rated capacity
temperature to the original setting.

Setting temperature
Indoor temperature
Point 2
When room temperature reaches the desired
Measured capacity
setting, capacity eases in order to maintain
the set temperature level.

Operation time (min)

Point 1 Quick & Powerful Point 2 Room Temperature Maintained


Increasing the compressor motor speed by controlling the operation The compressor motor operating frequency and the change of room
frequency ensures powerful output at start-up, brings the room temperature are monitored to calculate the most efficient waveform
temperature to the comfort zone faster than units not equipped with to maintain the room temperature in the comfort zone. This elimi-
an inverter. Hot rooms are cooled, and cold rooms are heated faster nates the large temperature swings common to non-inverter sys-
and more efficiently. tems, and guarantees a pleasant, comfortable environment.

7
MORE ADVANTAGES WITH MITSUBISHI ELECTRIC
Joint Lap DC Motor PAM (Pulse Amplitude Modulation)
Mitsubishi Electric has developed a unique motor, called the PAM is a technology that controls the current waveform so that it
“Poki-Poki Motor” in Japan, which is manufactured using a joint resembles the supply voltage wave, thereby reducing loss and real-
lapping technique. This innovative motor operates based on a ising more efficient use of electricity. Using PAM control, 98% of the
high-density, high-magnetic force, leading to extremely high effi- input power supply is used effectively.
ciency and reliability.
Without PAM control With PAM control
Supply
voltage

Time
Current Time

PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

■ Merits of PAM Control Power increased


Efficient voltage increase
realises increased power
Significant energy savings
Reluctance DC Rotary Compressor Remarkable reduction in power
PAM
loss saves electricity Conventional
Powerful neodymium magnets are used in the rotor of the reluc- inverter
tance DC compressor motor. More efficient operation is realised by
strong magnetic and reluctance torques produced by the magnets. Limited power
Limited energy savings Insufficient power
Electricity is wasted when needed
Neodymium
magnets
DC compressor
motor (rotor)

Power Receiver and Twin LEV Control


Mitsubishi Electric has developed a power receiver and twin linear
expansion valves (LEVs) circuit that optimise compressor perfor-
mance. This technology ensures optimum control in response to op-
erating waveform and outdoor temperature. Operating efficiency has
been enhanced by tailoring the system to the characteristics of R410A
refrigerant.

Magnetic torque
+ Heat
exchanger
Compressor
Reluctance torque
Power Heat
receiver exchanger
LEV1 LEV2

Rare Earth Magnet Rotor (Compressor)


An innovative motor with a rare earth magnet rotor is equipped in the
compressor to ensure excellent efficiency. The rare earth magnet
Grooved Piping
has a residual magnetic flux density threefold that of the previously
used ferrite magnet. High-performance grooved piping is used in heat exchangers to in-
crease the heat exchange area.

Grooved piping

Rare earth magnet


(for MSZ-EF) Pipe image
Cross-sectional view

DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit.
Efficiency is much higher than an equivalent AC motor.

8
FUNCTIONS (1)

ENERGY-SAVING
Econo Cool Energy-Saving Feature Econo Cool Mode
A comfortable room environment is maintained even when setting the
“Econo Cool” is an intelligent temperature control feature that adjusts temperature 2°C higher than the conventional cooling mode.
the amount of air directed towards the body based on the air-outlet Econo Cool on Conventional cooling mode
temperature. The setting temperature can be raised by as much as
2°C without any loss in comfort, thereby realising a 20% gain in
energy efficiency. (Function only available during manual cooling operation.)
Conventional Econo Cool
Ambient temperature 35°C 35°C
Set temperature 25°C 27°C
Perceived temperature 30°C 29.3°C Temperature distribution (°C)

14 16 18 20 22 24 26 28

ATTRACTIVE
Pure White Auto Vane
Pure white is adopted for the unit colour; white expressing the The vane closes automatically when the air conditioner is not
essence of cleanliness and easily matching virtually all interior décor. running, concealing the air outlet and creating a flat surface that is
aesthetically appealing.

AIR QUALITY
Fresh-air Intake Catechin Filter
Indoor air quality is enhanced by the direct intake of fresh exterior air. Catechin is a bioflavonoid by-product of green tea with both antiviral
and antioxidant qualities. It also has an excellent deodorising effect,
Anti-allergy Enzyme Filter which is why Mitsubishi Electric uses the compound in its air condi-
tioner filters. In addition to improving air quality, it prevents the
The anti-allergy enzyme filter works to trap allergens such as molds
spreading of bacteria and viruses throughout the room. Easily re-
and bacteria and decompose them using enzymes retained in the
moved for cleaning and maintenance, when the filter is washed regu-
filter.
larly the deodorising action is rated to last more than 10 years.
High-efficiency Filter
Long-life Filter
This high-performance filter has a much finer mesh compared to stan-
dard filters, and is capable of capturing minute particulates floating in A special process for the entrapment surface improves the filtering
the air that were not previously caught. effect, making the maintenance cycle longer than that of units
equipped with conventional filters.
Nano
Platinum Nano Platinum Filter
The filter has a large capture area and incorporates nanometre-sized
Filter Check Signal
platinum-ceramic particles that work to eliminate bacteria and deo- Air conditioner operating time is monitored, and the user is notified
dourise the circulating air. when filter maintenance is necessary.

Electrostatic
Anti-allergy Electrostatic Anti-allergy Enzyme Filter
This function features both the Air Cleaning Filter and Anti-allergy
Enzyme Filter.

9
SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

AIR SYSTEM
MAJOR DISTRIBUTION
CONTROL
Horizontal Vane High Ceiling Mode
System Examples
The air outlet
Indoor Unit vane swings up and down so that the
Mairflow is spread
series Indoor Unit In the case of rooms withShigh ceilings,
series the
& P series outlet-air
Indoor Unit volume can be
evenly
Outdoorthroughout
Unit the room. MXZ Series Outdoor increased to ensure that air is MXZ
circulated all the way to the floor.
Series Outdoor

Vertical Vane Low Ceiling Mode


MAC397IF-E

The air outlet fin swings from side to side so that the airflow
Indoor unit reaches
If the room has a low ceiling, the airflow volume can be reduced for
every part of the
PAR-30MAA room.
Control less draft.
Outdoor unit PAR-30MAA
PAR-21MAA Control PAR-21MAA
PAR-30MAA

Auto Fan Speed Mode


PAR-21MAA

The airflow speed mode adjusts the fan speed of the indoor unit
• Wired remote controller can be connected to Standard equipment
Details automatically according to the present
indoor unit (for indoor units compatible with wiredroom
remoteconditions.
controllers)
Wide and Long Airflow
• MAC-397IF-E (Interface)
• PAR-30MAA (Wired remote controller)
Major
The Optional
wide andParts
longRequired • PAR-30MAA
airflow function (Wired remote
is especially controller)
beneficial for large spaces, helping to ensure that air
• PAR-21MAA is well
(Wired circulated
remote controller) and reaches every corner
• PAR-21MAA (Wired remote controller)
of the room.

Indoor unit Indoor unit

CONVENIENCE
MAC-397IF-E MAC-397IF-E

System Group Control


PAR-30MAA PAR-30MAA

On/Off Operation Timer


Outdoor unit Outdoor unit PAR-21MAA PAR-21MAA

Use the remote controller to set the times of turning the air conditioner On/Off.
• One remote controller can control plural air conditioners with the same settings simultaneously.
Details • One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)
“i save” Mode/Smart Set • Up to two remote controller can be connected.

“iMajor
save” is a simplified setting ••function
Optional Parts Required
MAC-397IF-E (Interface)
that recalls the preferred (preset) temperature by pressing a single button on the remote controller.
PAR-30MAA (Wired remote controller)
Smart Set : Press the same button twice (Wired
• PAR-21MAA in repetition to immediately return to the previous temperature setting.
remote controller)
Using this function contributes to comfortable waste-free operation, realising the most suitable air conditioning settings and saving on power
consumption when, for example, leaving the room or going to bed. Outdoor Outdoor
Outdoor unit unit unit

Indoor unit Indoor unit PAC-SC50KUA


Indoor unit Power supply Indoor unit Indoor unit

Low-temperature Cooling City Multi


Auto Restart City Multi
kit
PAR-30MAA PAR-30MAA
indoor unit indoor unit PAR-21MAA PAR-21MAA
PAR-30MAA PAR-30MAA
Intelligent fan speed control in the outdoor unit ensures
M-NET Connections optimum
MELANS
system controller
Especially useful at the time of power outages, the unit turns back on
PAR-21MAA PAR-21MAA
MAC-399IF-E MAC-399IF-E
performance even when the outside temperature is low. (AG-150A etc)
PAC-SC50KA
automatically whenMELANS
power is restored.
system controller
Power supply (AG-150A etc) M-NET adapter
unit MELANS PAC-SF81MA-E
ME remote controller system controller
PAC-SC50KA
(PAR-F27MEA) Power supply (AG-150A etc)
unit

Ampere Limit •Adjustment Low-noise Operation (Outdoor Unit)


Details Group of air conditioners can be controlled by MELANS system controller (M-NET).

Dipswitch settings can be used to adjust the maximum electrical System operation can be adjusted to prioritise less noise from the
• MAC-399IF-E (M-NET Interface) • PAC-SF81MA-E (M-NET converter)
current for operation.
Major Optional This function
Parts Required • MELANS is highly
System recommended for
controller outdoor unit over air conditioning performance.
• MELANS System controller
• PAC-SC50KUA (power supply unit) • PAC-SC50KUA (power supply unit)
managing energy costs.
*Maximum capacity is lowered with the use of this function.

MAJOR OPTIONAL PARTS


Operation Lock Auto Changeover
ToM-NET Interface
accommodate specific use applications, cooling or heating Airair
The Discharge
conditioner Guide
automatically switches between heating and cool-
Interface to connect with M-NET con- M-NET interface Changes the direction of air being
operation
trollers. can be specified when setting the control board of the ing modes from
exhausted to maintain the desired
the outdoor unit. temperature.
outdoor unit. A convenient option when a system needs to be
configured for exclusive cooling or heating service.

10
FUNCTIONS (2)

Built-in Weekly Timer Function


Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
■ Example Operation Pattern (Winter/Heating mode)
Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time

OFF OFF OFF OFF OFF ON 18°C ON 18°C


Midday is warmer,
Automatically turned off during work hours so the temperature is set lower

ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C


Automatically raises temperature setting to
Automatically turns on, synchronized with arrival at home match time when outside-air temperature is low
(during sleeping hours)
ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C
Automatically lowers temperature at bedtime for energy-saving operation at night

Pattern Settings: Input up to four settings for each day


Settings
Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.

Cleaning-free Pipe Reuse


The application of pipe reuse technology such as Mitsubishi Electric’s original hard alkyl benzene oil makes it possible to reuse the same piping,
thereby allowing cleaning-free renewal of air conditioning systems that use R22 refrigerant.

Wiring/Piping Correction Function*


The push of a single button is all that is required to confirm that Wiring
confirmation
piping and wiring are properly connected. Corrections are made au- is time
The outdoor unit
matches
tomatically if a wiring error is detected, eliminating the need for com- consuming. pipes and wiring.

plicated wiring confirmation work when expanding the number of


rooms served.
* This function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes, and only works when the unit is set
to the Cooling mode.

Drain Pump Flare Connection


A built-in drain pump enables drain piping to be raised. Flare connection to cooling pipe work is possible.

MAINTENANCE
Easy Clean
The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the
inside of the air conditioner in minutes. Periodic cleaning of the air conditioner is recommended to maintain optimum operating efficiency and
energy savings.

Self-Diagnostic Function (Check Code Display) Failure Recall Function


Check codes are displayed on the remote controller or the operation Operation failures are recorded, allowing confirmation when needed.
indicator to inform the user of malfunctions detected.

11
SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

MAJOR SYSTEM CONTROL


System Examples
Indoor Unit M series Indoor Unit S series & P series Indoor Unit
Outdoor Unit MXZ Series Outdoor MXZ Series Outdoor

MAC397IF-E

Indoor unit

PAR-30MAA Control
Outdoor unit PAR-30MAA
PAR-21MAA Control PAR-21MAA
PAR-30MAA
PAR-21MAA

• Wired remote controller can be connected to Standard equipment


Details
indoor unit (for indoor units compatible with wired remote controllers)

• MAC-397IF-E (Interface)
• PAR-30MAA (Wired remote controller)
Major Optional Parts Required • PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)

Indoor unit Indoor unit

MAC-397IF-E MAC-397IF-E

System Group Control


PAR-30MAA PAR-30MAA
Outdoor unit Outdoor unit PAR-21MAA PAR-21MAA

• One remote controller can control plural air conditioners with the same settings simultaneously.
Details • One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)
• Up to two remote controller can be connected.

• MAC-397IF-E (Interface)
Major Optional Parts Required • PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)

Outdoor Outdoor
Outdoor unit unit unit

Indoor unit Indoor unit PAC-SC50KUA


Indoor unit Power supply Indoor unit Indoor unit
kit
City Multi City Multi PAR-30MAA PAR-30MAA
indoor unit indoor unit PAR-21MAA PAR-21MAA
PAR-30MAA PAR-30MAA
PAR-21MAA PAR-21MAA
M-NET Connections MAC-399IF-E
MELANS
system controller
(AG-150A etc) MAC-399IF-E
MELANS
PAC-SC50KA system controller
Power supply (AG-150A etc) M-NET adapter
unit MELANS PAC-SF81MA-E
ME remote controller system controller
PAC-SC50KA
(PAR-F27MEA) Power supply (AG-150A etc)
unit

Details • Group of air conditioners can be controlled by MELANS system controller (M-NET).

• MAC-399IF-E (M-NET Interface) • PAC-SF81MA-E (M-NET converter)


Major Optional Parts Required • MELANS System controller • MELANS System controller
• PAC-SC50KUA (power supply unit) • PAC-SC50KUA (power supply unit)

MAJOR OPTIONAL PARTS

M-NET Interface Air Discharge Guide


Interface to connect with M-NET con- M-NET interface Changes the direction of air being
trollers. exhausted from the outdoor unit.

12
FUNCTION LIST
Category
Category
Icon Indoor Unit MSY-EF (10/13/18) M SERIES MSY-GE (10/13/18/24/26) MLZ-KA (25/35/50)
Outdoor Unit MXY-2E MXY-3A MXY-4A MXY-2E MXY-3A MXY-4A MXY-2E MXY-3A MXY-4A
Combination
Indoor unit MSZ-FD20/35/50VA(S) MSZ-EF22/25/35/42/50VE(W)(B)(S) MSZ-GE22/25/35/42/50/60/71VA MSZ-SF15/20VA
DC Inverter
Joint Lap DC Motor
MUZ MXZ MXZ MXZ MXZ MXZ MXZ MUZ MXZ MXZ MXZ MXZ MXZ MXZ MUZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ
OutdoorReluctance
unit DC Rotary Compressor 4A38 4A38 4A38
-FD -2C -3C -4C -5C -6C -8B -EF -2C -3C -4C -5C -6C -8B -GE -2C -3C -4C -5C -6C -8B -2C -3C -4C -5C -6C -8B
Rare Earth Magnet Rotor (Compressor)
Technology DC Inverter
Technology DC Fan Motor
Joint Lap DC Motor PAM (Pulse Amplitude Modulation)
Power Receiver and Twin LEV Control
Magnetic Flux Vector Sine Wave Drive
Grooved Piping
Reluctance
Energy DC Rotary Compressor
Saving Econo Cool Energy-saving80Feature 80 80 80
Pure White
Highly Efficient DC Scroll Compressor VAW VAW VAW
Attractive
Auto Vane
Rare Earth Magnet Rotor(Compressor)
Fresh-air Intake
DC Fan Motor Anti-allergy Enzyme Filter Opt 10-18 Opt 10-18 Opt 10-18 Opt Opt Opt
Vector-Wave Eco Inverter Electrostatic Anti-allergy Enzyme Filter Opt Opt Opt Opt 24/26 Opt 24/26
High-efficiency Filter
PAM(Pulse
Air Quality Amplitude Modulation)
Catechin Filter 10-18 10-18 10-18 Opt Opt Opt
Power Receiver and Twin LEV Control
Nano Platinum Filter 24/26 24/26
Grooved Piping Long-life Filter
Energy Filter Check Signal
Felt Temperature Control (i-see Sensor)
Saving Horizontal Vane
AREA Temperature Monitor Vertical Mode 24/26 24/26
Econo Cool Energy-saving Feature High Ceiling Mode
Air Distribution
Low Ceiling Mode
'I-Feel' Control
Functions Auto Fan Speed Mode
Demand Function Opt Opt Opt Opt
Wide and Long Airflow 24/26 24/26
Attractive Pure White On/Off Operation
VA VA Timer
VA VA VA VA VA VEW VEW VEW VEW VEW VEW VEW
Auto Vane
"i save" Mode / Smart Set *2 *2 *2
Auto Restart
Air Quality Plasma Duo
Convenience Low-noise Operation
Air Cleaning Filter Ampere Limit Adjustment
Fresh-air Intake Operation Lock
Built-in Weekly Timer Function 24/26 24/26
Anti-allergy Enzyme Filter Opt Opt Opt Opt Opt Opt Opt
Cleaning-free Pipe Reuse 22-50 22-50 22-50 22-50 22-50 22-50 22-50
Electrostatic Anti-allergy Enzyme Wiring/Piping
Filter Opt Opt Opt Opt Opt Opt
Correction Function Opt Opt Opt Opt Opt Opt 4A38 Opt 60/71 60 60/71 60/71 60/71 4A38
60/71 4A38
Installation
High-efficiency Filter Drain Pump
Flare Connection
Catechin Filter 22-50 22-50 22-50 22-50 22-50 22-50 22-50
Easy Clean
Nano Platinum Filter
Maintenance Self-Diagonosis Function (Check Code Display) 60/71 60 60/71 60/71 60/71 60/71

Oil Mist Filter Failure Recall Function

Long-life Filter
Indoor Unit MSZ-EF (25/35/50) MSZ-GE (25/35/50/60/71)
Category Filter Check Signal
Outdoor Unit MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C
Air Horizontal Vane
Distribution DC Inverter
Vertical Vane Joint Lap DC Motor 60/71 60/71 60/71 60/71 60/71

High Ceiling Mode Reluctance DC Rotary Compressor 4C80 4C80


Rare Earth Magnet Rotor (Compressor)
Technology Low Ceiling Mode
DC Fan Motor
Auto Fan Speed Mode PAM (Pulse Amplitude Modulation)
Wide and Long Airflow Power Receiver and Twin LEV Control 60/71 60/71 60/71 60/71 60/71
Grooved Piping
Functions

Convenience On/off Operation Timer


Energy Saving Econo Cool Energy-saving Feature
"i save" Mode Pure White VEW VEW VEW VEW VEW
Attractive
Auto Changeover Auto Vane *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1
Auto Restart
Fresh-air Intake
Anti-allergy Enzyme Filter Opt 25-50 Opt 25-50 Opt 25-50 Opt 25-50
Low-temperature Cooling
Electrostatic Anti-allergy Enzyme Filter Opt Opt Opt Opt Opt Opt 60 Opt 60/71 Opt 60/71
Low-noise Operation(OutdoorHigh-efficiency
Unit) Filter
Air Quality
Ampere Limit Adjustment Catechin Filter 25-50 25-50 25-50 25-50
80 80 80 80
Nano Platinum Filter 60 60/71 60/71
Operation Lock
Long-life Filter
Built-in Weekly Timer FunctionFilter Check Signal 60/71 60 60/71 60/71 60/71 60/71
Horizontal Vane
Rotation, Back-up and 2nd Stage Cut-in Functions
Vertical Mode 60 60/71 60/71
System PAR-30MAA Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
Control High Ceiling Mode
Air Distribution
PAR-21MAA Control *3 Low Ceiling
Opt Mode
Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Centraliesd On/Off Control *3Auto Fan Speed Mode


Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
Functions Wide and Long Airflow 60 60/71 60/71
System Group Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
On/Off Operation Timer
M-NET Connection *3 "I save"Opt
ModeOpt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

COMPO *4 Auto Changeover *1 *1 *1 *1 *1 *1 *1 *1 *1


Auto Restart
MXZ Connection *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 22-50*2 22-50*2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2
Convenience Low-temperature Cooling
Installation Cleaning-free Pipe Reuse Low-noise Operation
Reuse of Existing Wiring Ampere Limit Adjustment 4C80 4C80
Operation Lock
Wiring/Piping Correction Function 80 80 80 80
Built-in Weekly Timer Function 60 60/71 60/71
Drain Pump Cleaning-free Pipe Reuse
Pump Down Switch Wiring/Piping Correction Function 4C80 4C80
Installation
Drain Pump
Flare Connection
Flare Connection
Maintenance Quick Clean Body Easy Clean
Maintenance Self-Diagonosis Function (Check Code Display)
Self-Diagnosis Function(Check Code Display)
Failure Recall Function
Failure Recall Function
*1 When multiple indoor units connected to an MXZ outdoor unit are runnning at the same time, simultaneours cooling and heating is not possible.
13 *2 Smart Set is available for MSY-GE10/13/18VA, "i save" mode is available for MSY-GE24/26VA
PLA-RP (50/60/71) SEZ-KD (25/35/50/60/71) M SERIES S SERIES
MSZ-
MXY-3A MSC- MSH- MSH- MSH- MS- MS- MS-
MXY-4A MXY-2E MXY-3A MXY-4A
HC25/35 GE20/25/35 GE50 GA60 GD80 GE50 GA60 GD80 MFZ-KA25/35/50VA MLZ-KA25/35/50VA SLZ-KA25/35/50VAL/VAQ SEZ-KD25/35/50/60/71VAL/VAQ
VA(B) VB VB VB VB VB VB VB

MUZ MUH MU MUH MUH MUH MU MU MU SUZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ
-HC -GA -GA -GE -GA -GD -GE -GA
4A38
-GD -KA -2C -3C -4C -5C -6C -8B -2C -3C -4C -5C -6C -8B -KA -2C -3C -4C -5C -6C -8B -KA -2C -3C -4C -5C -6C -8B
4A38

80 80 80 71 80

35

Opt Opt

Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt

4A38 4A38
Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt

MLZ-KA (25/35/50) PLA-RP (50/60/71) SEZ-KD (25/35/50/60/71)


VAQ VAQ VAQ VAQ VAQ VAQ VAQ
MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C

4C80 4C80 4C80

*1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1

Opt 25-50 Opt Opt Opt Opt Opt


Opt 60/71
Opt Opt Opt Opt
25-50 Opt Opt Opt Opt Opt
80 80 80 80
60/71

60/71
Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
60/71
Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
*1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1

*2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2

4C80 4C80 4C80

80 80 80 80
60/71
Opt Opt Opt Opt Opt Opt Opt
4C80 4C80 4C80
Opt Opt Opt Opt Opt

14
MXY SERIES

15
SELECTION
Choose from three types of indoor units and three types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1 SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted Cassette Ceiling-concealed

MSY-EF

MSY-GE(10-18)

MLZ-KA PLA-RP SEZ-KD

MSY-GE(24-26)

STEP 2 SELECT OUTDOOR UNITS


Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port 3-port 4-port


Connect up to 2 indoor units Connect up to 3 indoor units Connect up to 4 indoor units

MXY-2E20VA MXY-3A28VA MXY-4A28VA MXY-4A38VA

STEP 3 CHECK SYSTEM COMPATIBILITY


Possible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

16
MXY SERIES
Our Inverter Technology adjusts capacity in response to conditions such as
the difference between the outside and inside air temperatures, allowing
our air conditioners to run more efficiently and reduce energy costs.

2-port 3-port 4-port 4-port

MXY-2E20VA MXY-3A28VA MXY-4A38VA


MXY-4A28VA

EXAMPLE SYSTEM

MSY-EF

MSY-GE

PLA-RP

MLZ-KA

MXY-4A38VA

Handle Up to 4 Rooms with a Single Outdoor Unit


The MXY Series offers a four-system line-up to choose from, ranging between 5.0 and 9.2kW. All of them are compatible with specific M, S and
P series indoor units. A single outdoor unit can handle a wide range of building layouts.

MXY SERIES
4A38 2A/3A 3A/4A

Cooling Only MULTI


Type Inverter Cooling Only
Model Name MXY-2E20VA MXY-3A28VA MXY-4A28VA MXY-4A38VA
Power Supply (V/Phase/Hz) 230/Single/50
Rated kW 5.0 7.5 7.5 9.2
Capacity
Cooling Min - Max kW 1.10 - 6.55 2.9 - 8.9 3.7 - 8.9 3.7 - 11.2
Input Rated kW 1.44 2.18 2.16 2.45
H×W×D mm 550 - 800 - 285 710 - 840 - 330 900 - 900 - 320
Dimensions
Weight kg 38 57 58 67
Outdoor Air Volume Cooling m3/min 31 42.1 42.1 42.2
Sound Level (SPL) Cooling dB(A) 49 49 49 46
Breaker Size A 15 25 25 25
Liquid mm 6.35 × 2 6.35 × 3 6.35 × 4 6.35 × 4
Diameter
Gas mm 9.52 × 2 9.52 × 3 9.52 × 3 + 12.7 × 1 9.52 × 3 + 12.7 × 1
Ext. Piping Total Piping Length (max) m 30 60 60 70
Each Indoor Unit Piping Length m 20 25 25 25
Max. Height m 15 (10)* 15 (10)* 15 (10)* 15 (10)*
"Guaranteed Operating
Range(Outdoor)" Cooling °C -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46
*If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.

17
MSY-EF10/13/18VAW White

MSY-E
Developed to complement modern interior room
décor, StarMEX ZEN air conditioners are available in
SERIES MSY-EF10/13/18VAS Silver

three colors specially chosen to blend in naturally


wherever installed.
MSY-EF10/13/18VAB Black

Stylish Line-up Matches


Any Room Décor
The streamlined wall-mounted indoor units have eloquent
silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet
yet powerful performance, these units provide a best-
match scenario for diverse interior designs while simultane-
eously ensuring maximum room and energy savings.

Superior Exterior
Quiet Comfort All Day Long and Operating Design Concept
Mitsubishi Electric’s advanced “Silent Mode” fan speed setting pro- The indoor unit of the StarMEX ZEN keeps its amazingly thin form
vides super-quiet operation as low as 21dB for EF10/13 models. This even during operation. The only physical change notable is the
unique feature makes the StarMEX ZEN series ideal for use in any sit- movement of the variable vent. As a result, a slim attractive look is
uation. maintained.

● Noise Level Human Closed Open


Quiet passenger
Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)

80dB 60dB 40dB 10dB


Only 21dB
(for EF10/13 models)

Built-in Weekly Timer Function


Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

Electrostatic Nano
Anti-allergy Platinum
Optional Optional Optional
4A

Optional

Type Cooling Only


Model Name MSY-EF10VAW/B/S MSY-EF13VAW/B/S MSY-EF18VAW/B/S
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air Volume m3/min 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 5.8 - 6.8 - 7.9 - 9.3 - 11.0
Cooling Silent-Lo-Mid-Hi-SHi*
SPL dB(A) 21 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 30 - 33 - 36 - 40 - 43
Operating Current (max.) 0.14 0.14 0.18
Demensions H×W×D mm 299 - 895 - 195 299 - 895 - 195 299 - 895 - 195
Weight kg 11.5 11.5 11.5
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
*SHi : Super High

18
MSY-GE10/13/18VA

MSY-G
MSY-GE24/26VA

SERIES
The standard model MSY-G units provide excellent energy savings and operation is
impressively silent. A vast series line-up is ready to ensure comfortable room
environments in response to your air conditioning needs.

10/13

Wide Line-up Quiet Operation


Only
19dB
Five different indoor units (Model 10-26) are available to meet your A “Silent Mode” setting has been added to the fan speed settings,
diversified air conditioning needs. ensuring super-quiet operation below 20dB for model sizes 13 and
under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

MSY-GE10/13/18VA MSY-GE24/26VA
24/26

Stylish and Compact Nano Platinum Filter Nano


Platinum

An elegant, high-quality look is achieved through the new stylish This filter incorporates nanometre-sized platinum-ceramic particles
design adopted for indoor units. The simple ergonomic square shape that generate stable antibacterial and deodourising effects. The size
and pure white color express a sense of sophistication that matches of the three-dimensional surface has been increased as well, enlarg-
well with virtually any interior décor. ing the filter capture area. These features give the Nano Platinum
Fits neatly above
Filter of the MSY-GE24/26 models better dust collection perfor-
800mm-wide doors. mance than conventional filters. The superior air-cleaning effective-
MSY-GE10/13/18VA
ness raises room comfort yet another level.
800mm

Only 798mm In the case of MSY-GE10-18

It is okay to wash the filter with water


(air-cleaning effect is maintained) 3D surface (Waved surface)

24/26*2

“i save” Mode
“i save” is a simplified setting function that recalls the preferred
Cooling Cooling
(preset) temperature by pressing a single button on the remote con-
troller. Press the same button twice in repetition to immediately 22 co
24 c
o

return to the previous temperature setting. Using this function con-


tributes to comfortable, waste-free operation, realizing the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.

10 - 18 24/26 10 - 18 24/26 24/26 24/26 24/26*1 24/26*2

Electrostatic Nano
Anti-allergy Platinum
Optional Optional
4A

Optional Optional Optional

Type Cooling Only


Model Name MSY-GE10VA MSY-GE13VA MSY-GE18VA MSY-GE24VA*1 MSY-GE26VA
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air m3/min 4.2 - 4.9 - 6.7 - 8.9 - 11.4 4.2 - 4.9 - 6.7 - 9.2 - 12.8 6.5 - 7.8 - 9.6 - 11.8 - 15.1 N/A - 9.7 - 13.3 - 15.4 - 17.9 9.7 - 11.5 - 13.3 - 15.4 - 17.9
Cooling Volume Silent-Lo-
Mid-Hi-SHi*
SPL dB(A) 19 - 21 - 29 - 36 - 40 19 - 22 - 30 - 36 - 45 28 - 33 - 38 - 44 - 49 N/A - 30 - 40 - 45 - 49 30 - 37 - 41 - 45 - 49
Operating Current (max.) 0.22 0.29 0.39 0.55 0.55
Demensions H×W×D mm 295 - 798 - 232 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238
Weight kg 10 10 10 16 16
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 9.52/15.88 9.52/15.88
*SHi : Super High
1
* Functions and specification may differ depending on the market.
*2 Smart Set is available for MSY-GE10/13/18VA.

19
MLZ-KA25/35/50VA

MLZ SERIES
Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.

Ceiling Mounted Access door not required Slim Body


Installing the ceiling-mounted MLZ The new units are designed with a slim body (only 175mm high), en-
Series unit in a room creates a more suring easy installation even when low ceiling cavities limit installa-
spacious feel that enhances room tion space. The need for ceiling cavity service space is also elimi-
comfort. This overhead format is also nated, further reducing the dimensions required for installation.
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as 175mm
book shelves are mounted on wall
surfaces.

Air Volume Settings by Ceiling Height Auto Vane Control


Dual-level airflow selection is engineered to accommodate specific Outlet vanes can be moved left
ceiling heights. This is a key feature for adjusting airflow effectively and right, and up and down
when it is either too strong or too weak due to being mismatched using the remote controller.
with the height of the ceiling. This improved airflow control
feature solves the problem of
25 35 50
drafts.
Standard 2.4m 2.4m 2.4m Left and Right
High ceiling 2.7m 2.7m 2.7m
Up and Down

Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.
Installation Example
● Drain Piping Supporters

Easy joint
connections! Flexible drain joints Refrigerant pipe
Built-in drain pump
secures drainage
water lift of 500mm Insulating material wrapping
only required from this point

Insulation material pretreatment


Flexible drain joints simplify
eliminates need for wrapping.
drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover

● Easy Mounting Plate


Suspension work simplified with
Secure one side Push the unit to the other side Move unit to the centre
well-designed mounting plates
Secure the opposite side

Optional Optional Optional Optional Optional


4A

Type Cooling Only


Model Name MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
3
Air Volume m /min 7.2 - 8.0 - 8.8 7.3 - 8.4 - 9.4 8.3 - 9.8 - 11.4
Cooling Lo-Mid-Hi
SPL dB(A) 29 - 32 - 35 31 - 34 - 37 34 - 38 - 43
Operating Current (max.) 0.4 0.4 0.4
Demensions H×W×D mm 175 - 1102 - 360 175 - 1102 - 360 175 - 1102 - 360
Weight kg 15 15 15
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7

20
PLA-RP50/60/71

PLA SERIES
The incorporation of wide air-outlet and the “i-see Sensor” enhances airflow distribution
control, achieving an enhanced level of comfort throughout the room. The synergy of
higher energy efficiency and more comfortable room environment results in the utmost
user satisfaction.

Optimum Airflow
Individual Vane Settings Wide Airflow Image of multi-directional
Optimum airflow settings provide maximum Wide-angle outlets distribute airflow air conditioning

comfort throughout the room. to all corners of the room.


In addition to the selection of variable airflow patterns (i.e., 2-, The outlets are larger than those of previous
3- or 4-way), this function allows the independent selection of models and the shape has been improved for
vertical airflow levels for each vane, thereby maintaining a com- better wide-angle ventilation.
fortable room environment with even temperature distribution.

2-, 3-, 4-way airflow


pattern selection
Previous
* Optional shuffle placement is required
for 2- and 3-way patterns.
model

Individual Vane
Wide Airflow
Horizontal
New 4-Way Ceiling Cassette Setting
Airflow direction at
each vane can be set
using the wired remote The combination of individual vane setting,
controller. Fixed which enables the optimal outlet setting for
Adjustable
Downward each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
72 airflow patterns comfortable air conditioning.

The New Swing Function Cools All Corners of the Room


Wave Airflow Operation
“Wave Airflow” is essentially the advanced control of the vanes
directing the airflow from the unit. Blown-air is repeated dispersed
from the unit in horizontal and downward directions at time-lagged
intervals to provide uniform heating throughout the room.
Downward Downward Downward Downward
Thermograph of Wave Control Effect ✽ Vertical swinging mode is adapted in the case of cooling operation
Horizontal Airflow Wave Airflow

Indoor Unit Indoor Unit

Temperature distribution comparison approxi-


mately 20min after turning on a PLA-RP71BA
Temperature gap Minimized temperature gap 4-Way ceiling cassette. The measurement point
Uneven temperature distribution Uniform cool air is supplied throughout the room, for comparison is a plane 1.2m above the floor.
minimizing uneven temperature distribution.

Optional

4A

Optional Optional

Type Cooling Only


Model Name PLA-RP50BA PLA-RP60BA PLA-RP71BA
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air Volume Lo-Mid2- m3/min 12.0 - 14.0 - 16.0 - 18.0 12.0 - 14.0 - 16.0 - 18.0 14.0 - 16.0 - 18.0 - 21.0
Cooling
SPL Mid1-Hi dB(A) 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34
Operating Current (max.) 0.36 0.36 0.51
Demensions H×W×D mm 258 - 840 - 840 258 - 840 - 840 258 - 840 - 840
Weight kg 22 23 23
Ext.Piping Diameter Liquid/Gas mm 6.35/12.7 6.35·9.52/15.88 9.52/15.88

21
SEZ SERIES SEZ-KD25-71VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Dimension 990 A Air inlet


B Air outlet
C Access door
D Ceiling surface
200 E Canvas duct
F Air filter
G Inlet grille

SEZ-KD35VAL

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

4A

Optional Optional Optional

Type Cooling Only


Model Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
3
Air Volume m /min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Cooling Lo-Mid-Hi
SPL dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
Operating Current (max.) 0.39 0.46 0.63 0.63 0.84
Demensions H×W×D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700
Weight kg 18 21 23 27 27
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
External Static Pressure 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50

22
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXY-

Indoor Unit 2E20VA 3A28VA 4A28VA 4A38VA

MSY-EF10VA
Wall-mounted

MSY-EF13VA

MSY-EF18VA

MSY-EF
MSY-GE10VA

MSY-GE13VA

MSY-GE(10-18)

MSY-GE18VA

MSY-GE(24-26)
MSY-GE24VA

MSY-GE26VA

MLZ-KA25VA
1-way cassette

MLZ-KA35VA

MLZ Series MLZ-KA50VA

PLA-RP50BA
4-way cassette

PLA-RP60BA

PLA Series PLA-RP71BA

SEZ-KD35VAL
Ceiling-concealed

SEZ-KD50VAL

SEZ-KD60VAL

SEZ Series

SEZ-KD71VAL

23
24
MXZ SERIES

25
SELECTION
Choose from three types of indoor units and five types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1 SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted Cassette Ceiling-concealed

MSZ-EF

MSZ-GE(25/35/50)

MLZ-KA PLA-RP SEZ-KD

MSZ-GE(60/71)

STEP 2 SELECT OUTDOOR UNITS


Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port 3-port 4-port


Connect up to 2 indoor units Connect up to 3 indoor units Connect up to 4 indoor units

MXZ-2C52VA MXZ-3C68VA MXZ-4C71VA MXZ-4C80VA

5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units

MXZ-5C100VA MXZ-6C120VA

STEP 3 CHECK SYSTEM COMPATIBILITY


Possible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

26
MXZ SERIES
Advancements in the MXZ Series include efficiency and flexibility in system
expansion capabilities. The best solution when requiring multi-system air
conditioning needs.

2-port 3-port 4-port 4-port 5-port 6-port


MXZ-2C52VA MXZ-3C68VA MXZ-4C80VA MXZ-6C120VA
MXZ-4C71VA MXZ-5C100VA

EXAMPLE SYSTEM
(example of MXZ-6C120VA system) MSZ-EF

MSZ-GE

MSZ-GE

MLZ-KA

PLA-BA
MXZ-6C120VA

SEZ-KD

Handle Up to 6 Rooms with a Single Outdoor Unit


The MXZ Series offers a six-system line-up to choose from, ranging between 5.2 and 12.0kW. All of them are compatible with specific M, S and
P series indoor units. A single outdoor unit can handle a wide range of building layouts.

MXZ SERIES
4C80-6C 2C/3C/4C 3C - 6C

INVERTER MULTI
Type Inverter Heat Pump
Model Name MXZ-2C52VA MXZ-3C68VA MXZ-4C71VA MXZ-4C80VA MXZ-5C100VA MXZ-6C120VA
Power Supply (V/Phase/Hz) 230/Single/50
Rated kW 5.2 6.8 7.1 8.0 10.0 12.0
Capacity
Cooling Min - Max kW 1.1 - 6.0 2.9 - 8.4 3.7 - 8.8 3.7 - 9.2 3.9 - 11.0 3.5 - 13.5
Input Rated kW 1.3 1.78 1.68 1.955 2.80 3.61
Rated kW 6.4 8.6 8.6 9.4 12.0 14.0
Capacity
Heating Min - Max kW 1.0 - 7.0 2.6 - 10.6 3.4 - 10.7 3.4 - 11.6 4.1 - 14.0 3.5 - 16.5
Input Rated kW 1.61 2.05 1.71 1.93 2.84 3.47
H×W×D mm 550 - 800 - 285 710 - 840 - 330 900 - 900 - 320 1070 - 900 - 320
Dimensions
Weight kg 38 57 58 67 68 88
Cooling m3/min 32.9 42.1 42.1 42.1 56.6 55.4
Air Volume
Outdoor Heating m3/min 33.3 43 43 43.8 59.3 69.9
Sound Level Cooling dB(A) 49 48 48 46 51 55
(SPL) Heating dB(A) 50 52 52 48 54 57
Breaker Size A 15 25 25 25 25 32
Liquid mm 6.35 × 2 6.35 × 3 6.35 × 4 6.35 × 4 6.35 × 5 6.35 × 6
Diameter
Gas mm 9.52 × 2 9.52 × 3 9.52 × 3 + 12.7 × 1 9.52 × 3 + 12.7 × 1 9.52 × 4 + 12.7 × 1 9.52 × 5 + 12.7 × 1
Ext.
Piping Total Piping Length (max) m 30 60 60 70 80 80
Each Indoor Unit Piping Length m 20 25 25 25 25 25
Max. Height m 15 (10)* 15 (10)* 15 (10)* 15 (10)* 15 (10)* 15 (10)*
"Guaranteed Operating Cooling °C -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43
Range(Outdoor)"
Heating °C -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24
* If the outdoor unit is installed higher than the indoor unit, max.height is reduced to 10m.

27
MSZ-EF25/35/50VEW White

MSZ-E
Developed to complement modern interior room
décor, Kirigamine ZEN air conditioners are available
SERIES MSZ-EF25/35/50VES Silver

in three colors specially chosen to blend in naturally


wherever installed.
MSZ-EF25/35/50VEB Black

Stylish Line-up Matches


Any Room Décor
The streamlined wall-mounted indoor units have eloquent
silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet
yet powerful performance, these units provide a best-
match scenario for diverse interior designs while simultane-
eously ensuring maximum room and energy savings

Superior Exterior
Quiet Comfort All Day Long and Operating Design Concept
Mitsubishi Electric’s advanced “Silent Mode” fan speed setting pro- The indoor unit of the Kirigamine ZEN keeps its amazingly thin form
vides super-quiet operation as low as 21dB for EF25/35 models. This even during operation. The only physical change notable is the
unique feature makes the Kirigamine ZEN series ideal for use in any movement of the variable vent. As a result, a slim attractive look is
situation. maintained.

● Noise Level Human Closed Open


Quiet passenger
Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)

80dB 60dB 40dB 10dB


Only 21dB
(for EF25/35 models)

Built-in Weekly Timer Function


Easily sets desired temperatures and operation start/stop A maximum of 4ON or OFF timers can be set for individual days of the week
times to match lifestyle patterns. Reduces wasted energy Setting
A maximum of 28 ON or OFF timers can be set for a week.
consumption by using the timer to prevent forgetting to turn
off the unit and eliminate temperature setting adjustments. E.g. : Runs at 24°C from waking up to leaving home, and runs at 27°C from
● Easy Set-up Using Dedicated Buttons getting home to going to bed on weekdays.
Runs at 27°C from waking up late to going bed early on weekends
The remote controller is equipped with buttons that are
Mon Setting1 Setting2 Setting3 Setting4
used exclusively for setting the Weekly Timer. Setting
ON OFF ON OFF
operation patterns easy and quick. 24°C 27°C
Fri
6:00 8:30 17:30 22:00
Sat Setting1 Setting2
ON OFF
Sun 27°C
8:00 21:00

Electrostatic Nano
Anti-allergy Platinum
Optional Optional Optional
4C/5C/6C 4C/5C/6C

Optional

Type Inverter Heat Pump


Model Name MSZ-EF25VEW/B/S MSZ-EF35VEW/B/S MSZ-EF50VEW/B/S
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air Volume m3/min 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 5.8 - 6.8 - 7.9 - 9.3 - 11.0
Cooling
SPL Silent-Lo-Mid-Hi-SHi* dB(A) 21 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 30 - 33 - 36 - 40 - 43
Air Volume m3/min 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 12.7 6.4 - 7.3 - 9.0 - 11.1 - 13.2
Heating
SPL Silent-Lo-Mid-Hi-Shi* dB(A) 21 - 24 - 29 - 37 - 45 21 - 24 - 30 - 38 - 46 30 - 33 - 37 - 43 - 49
Operating Current (max.) 0.3 0.3 0.4
Demensions H×W×D mm 299 - 895 - 195 299 - 895 - 195 299 - 895 - 195
Weight kg 11.5 11.5 11.5
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
*SHi : Super High

28
MSZ-GE25/35/50VA

MSZ-G
MSZ-GE60/71VA

SERIES
The standard model MSZ-G units provide excellent energy savings and operation is
impressively silent. A vast series line-up is ready to ensure comfortable room
environments in response to your air conditioning needs.

25-35

Wide Line-up Quiet Operation


Only
19dB
Five different indoor units (Model 25-71) are available to meet your A “Silent Mode” setting has been added to the fan speed settings,
diversified air conditioning needs. ensuring super-quiet operation below 20dB for model sizes 35 and
under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

MSZ-GE25/35/50VA MSZ-GE60/71VA
60/71

Stylish and Compact Nano Platinum Filter Nano


Platinum

An elegant, high-quality look is achieved through the new stylish This filter incorporates nanometre-sized platinum-ceramic particles
design adopted for indoor units. The simple ergonomic square shape that generate stable antibacterial and deodourising effects. The size
and pure white color express a sense of sophistication that matches of the three-dimensional surface has been increased as well, enlarg-
well with virtually any interior décor. ing the filter capture area. These features give the Nano Platinum
Fits neatly above
Filter of the MSZ-GE60/71 models better dust collection perfor-
800mm-wide doors. mance than conventional filters. The superior air-cleaning effective-
MSZ-GE25/35/50VA
ness raises room comfort yet another level.
800mm

Only 798mm In the case of MSZ-GE25-50

It is okay to wash the filter with water


(air-cleaning effect is maintained) 3D surface (Waved surface)

“i save” Mode
“i save” is a simplified setting function that recalls the preferred
Heating Heating
(preset) temperature by pressing a single button on the remote con-
troller. Press the same button twice in repetition to immediately 22 c o
18 co

return to the previous temperature setting. Using this function con-


tributes to comfortable, waste-free operation, realizing the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.

25 - 50 60/71 25 - 50 60/71 60/71 60/71 60/71

Electrostatic Nano
Anti-allergy Platinum
Optional Optional
4C/5C/6C 4C/5C/6C

Optional Optional Optional

Type Inverter Heat Pump


Model Name MSZ-GE25VA MSZ-GE35VA MSZ-GE50VA MSZ-GE60VA MSZ-GE71VA
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
Air m3/min 4.1 - 4.8 - 6.7 - 9.1 - 11.3 4.1 - 4.8 - 6.7 - 9.1 - 12.7 6.5 - 7.8 - 9.6 - 11.9 - 15.1 9.8 - 11.3 - 13.4 - 15.6 - 18.3 9.7 - 11.5 - 13.3 - 15.4 - 17.8
Cooling Volume Silent-Lo-
Mid-Hi-SHi*
SPL dB(A) 19 - 21 - 29 - 36 - 42 19 - 22 - 30 - 36 - 43 28 - 33 - 38 - 44 - 49 29 - 37 - 41 - 45 - 49 30 - 37 - 41 - 45 - 49
Air m3/min 4.1 - 4.8 - 6.6 - 9.1 - 11.5 4.1 - 4.8 - 6.7 - 9.1 - 11.5 6.5 - 7.9 - 9.6 - 12.2 - 14.5 9.8 - 11.3 - 13.4 - 15.6 - 18.3 10.2 - 11.5 - 13.3 - 15.4 - 17.8
Heating Volume Silent-Lo-
Mid-Hi-Shi*
SPL dB(A) 19 - 21 - 29 - 36 - 42 19 - 22 - 30 - 36 - 42 28 - 33 - 37 - 43 - 48 29 - 37 - 41 - 45 - 49 30 - 37 - 41 - 45 - 49
Operating Current (max.) 0.4 0.4 0.5 0.5 0.5
Demensions H×W×D mm 295 - 798 - 232 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238
Weight kg 10 10 10 16 16
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
*SHi : Super High

29
MLZ-KA25/35/50VA

MLZ SERIES
Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.

Ceiling Mounted Access door not required Slim Body


Installing the ceiling-mounted MLZ The new units are designed with a slim body (only 175mm high), en-
Series unit in a room creates a more suring easy installation even when low ceiling cavities limit installa-
spacious feel that enhances room tion space. The need for ceiling cavity service space is also elimi-
comfort. This overhead format is also nated, further reducing the dimensions required for installation.
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as 175mm
book shelves are mounted on wall
surfaces.

Air Volume Settings by Ceiling Height Auto Vane Control


Dual-level airflow selection is engineered to accommodate specific Outlet vanes can be moved left
ceiling heights. This is a key feature for adjusting airflow effectively and right, and up and down
when it is either too strong or too weak due to being mismatched using the remote controller. This
with the height of the ceiling. improved airflow control feature
solves the problem of drafts.
25 35 50
Standard 2.4m 2.4m 2.4m Left and Right
High ceiling 2.7m 2.7m 2.7m
Up and Down

Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.
Installation Example
● Drain Piping Supporters

Easy joint
connections! Flexible drain joints Refrigerant pipe
Built-in drain pump
secures drainage
water lift of 500mm Insulating material wrapping
only required from this point

Insulation material pretreatment


Flexible drain joints simplify
eliminates need for wrapping.
drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover

● Easy Mounting Plate


Suspension work simplified with
Secure one side Push the unit to the other side Move unit to the centre
well-designed mounting plates
Secure the opposite side

4C/5C/6C

Optional Optional Optional Optional Optional


4C/5C/6C

Type Inverter Heat Pump


Model Name MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
3
Air Volume m /min 7.2 - 8.0 - 8.8 7.3 - 8.4 - 9.4 8.3 - 9.8 - 11.4
Cooling Lo-Mid-Hi
SPL dB(A) 29 - 32 - 35 31 - 34 - 37 34 - 38 - 43
3
Air Volume m /min 7.0 - 8.2 - 9.2 7.7 - 8.8 - 9.9 8.8 - 10.3 - 11.8
Heating Lo-Mid-Hi
SPL dB(A) 28 - 32 - 36 31 - 35 - 38 34 - 39 - 43
Operating Current (max.) 0.4 0.4 0.4
Demensions H×W×D mm 175 - 1102 - 360 175 - 1102 - 360 175 - 1102 - 360
Weight kg 15 15 15
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
30
PLA-RP50/60/71
MLZ-KA25/35/50VA

MLZ
PLA
Introducing
The a new
incorporation
interior dimensions
control,
oftype
wideof
achieving an and
ceiling and
air-outlet
a sharp,
enhanced
cassette
sleek
level
SERIES
SERIES
for the
the “i-see
of appearance.
Multi-Split
Sensor” Series
enhances withdistribution
airflow streamed
comfort throughout the room. The synergy of
higher energy efficiency and more comfortable room environment results in the utmost
user satisfaction.

Ceiling Mounted Access door not required Slim Body


Installing the ceiling-mounted MLZ The new units are designed with a slim body (only 175mm high), en-
Series unit in a room creates a more suring easy installation even when low ceiling cavities limit installa-
spacious feel that enhances room tion space. The need for ceiling cavity service space is also elimi-
comfort. This overhead format is also nated, further reducing the dimensions required for installation.
an excellent solution when lighting
equipment is installed at the centre
Optimum Airflow
of the room and fixtures such as 175mm
book shelves are mounted on wall
surfaces.
Individual Vane Settings Wide Airflow Image of multi-directional
Optimum airflow settings provide maximum Wide-angle outlets distribute airflow air conditioning

comfort throughout the room. to all corners of the room.


Air Volume
In addition Settings
to the selection by
of variable airflow Ceiling
patterns (i.e., 2-, Height
The outlets are largerAuto Vane
than those Control
of previous
3- or 4-way), this function allows the independent selection of models and the shape has been improved for
vertical airflow
Dual-level levels for
airflow each vane,isthereby
selection maintaining
engineered a com-
to accommodate better wide-angle ventilation.
specific Outlet vanes can be moved left
fortable room environment with even temperature distribution.
ceiling heights. This is a key feature for adjusting airflow effectively and right, and up and down
when
2-, 3-, it is either
4-way airflow too strong or too weak due to being mismatched using the remote controller. This
pattern
with theselection
height of the ceiling. improved airflow
Previouscontrol feature
* Optional shuffle placement is required
model
for 2- and 3-way patterns. solves the problem of drafts.
25 35 50
Individual Vane
Standard 2.4m 2.4m 2.4m Left and Right Wide Airflow
Horizontal
New 4-Way Ceiling Cassette Setting
Airflow direction
High at
ceiling 2.7m 2.7m 2.7m
each vane can be set Up and Down
The combination of individual vane setting,
using the wired remote
controller. Fixed which enables the optimal outlet setting for
Adjustable
Downward each room layout, and the wide airflow function
Easy Installation works to ensure even temperature distribution
throughout each room. The result is uniformly
72 airflow patterns comfortable air conditioning.
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
Wave Airflow – Thoroughly Warming All Corners of the Room!
are free of condensation.
Installation Example
● Drain Piping Supporters
Wave Airflow Operation
“Wave Airflow” is essentially Easy the
joint advanced control of the vanes
directing the airflow from the connections!
unit. Blown-air is repeated dispersed
Flexible drain joints Refrigerant pipe
Built-in drain pump
from the unit
secures in horizontal and downward directions at time-lagged
drainage
intervals to of
water lift provide
500mm uniform heating throughout the room.
Insulating material wrapping Downward Downward Downward Downward
only required from this point
Thermograph of Wave Control Effect ✽ Wave Airflow is possible only when using the heating mode
Horizontal Airflow Wave Airflow
Insulation material pretreatment
Flexible drain joints simplify
eliminates need for wrapping.
Indoor Unit
drain piping work in narrow ceiling areas
Indoor Unit
The newly adopted insulation-free cover eliminates
the need for wrapping pipes with insulation tape and Temperature distribution comparison approxi-
prevents the forming of condensation. mately 20min after turning on a PLA-RP71BA
Temperature gap Minimized temperature gap 4-Way ceiling cassette. The measurement point
Uneven temperature distribution Warm air is supplied throughout the room, for comparison is a plane 1.2m above the floor.
Drain cover
minimizing uneven temperature distribution.
● Easy Mounting Plate
Suspension work simplified with
Secure one side Push the unit to the other side Move unit to the centre
well-designed mounting plates
Secure the opposite side
Optional

4C/5C/6C 4C/5C/6C

Optional Optional

Type Inverter Heat Pump


Model Name PLA-RP50BA PLA-RP60BA PLA-RP71BA
Power Supply (V/Phase/Hz) Outdoor (230/Single/150)
3
Heating and Air Volume m /min 12.0 - 14.0 - 16.0 - 18.0 12.0 - 14.0 - 16.0 - 18.0 14.0 - 16.0 - 18.0 - 21.0
Cooling Lo-Mid2-Mid1-Hi
SPL dB(A) 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34
Operating Current (max.) 0.36 0.36 0.51
Demensions H×W×D mm 258 - 840 - 840 258 - 840 - 840 258 - 840 - 840
Weight kg 22 23 23
Ext.Piping Diameter Liquid/Gas mm 6.35/12.7 6.35·9.52/15.88 9.52/15.88

31
SEZ SERIES SEZ-KD25-71VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Dimension 990
A Air inlet
B Air outlet
C Access door
D Ceiling surface
200 E Canvas duct
F Air filter
G Inlet grille

SEZ-KD35VAL

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

4C/5C/6C 4C/5C/6C

Optional Optional Optional

Type Inverter Heat Pump


Model Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Power Supply (V/Phase/Hz) Outdoor (230/Single/50)
3
Heating and Air Volume m /min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Cooling Lo-Mid-Hi
SPL dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
Operating Current (max.) 0.39 0.46 0.63 0.63 0.84
Demensions H×W×D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700
Weight kg 18 21 23 27 27
Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
External Static Pressure 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50

32
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXZ-

Indoor Unit 2C52VA 3C68VA 4C71VA 4C80VA 5C100VA 6C120VA

MSZ-EF25VE
Wall-mounted

MSZ-EF35VE

MSZ-EF50VE

MSZ-EF

MSZ-GE25VA

MSZ-GE35VA

MSZ-GE(25/35/50)

MSZ-GE50VA

MSZ-GE60VA

MSZ-GE(60/71)

MSZ-GE71VA

MLZ-KA25VA
1-way cassette

MLZ-KA35VA

MLZ Series MLZ-KA50VA

PLA-RP50BA
4-way cassette

PLA-RP60BA

PLA-RP71BA
PLA Series

SEZ-KD25VAL
Ceiling-concealed

SEZ-KD35VAL

SEZ-KD50VAL

SEZ-KD60VAL
SEZ Series

SEZ-KD71VAL

33
External Dimensions
Wall-Mounted Unit : mm
MSY-EF10VA MSY-EF13VA MSY-EF18VA MSY-GE10VA MSY-GE13VA MSY-GE18VA
MSZ-EF25VE MSZ-EF35VE MSZ-EF50VE MSZ-GE25VA MSZ-GE35VA MSZ-GE50VA
INDOOR UNIT INDOOR UNIT

895 798
875 10 785 6.5

Air in
Installation plate Air in

232
Piping 5
299

Installation plate
Piping
7

47
100

58
59 678 158

295
94 Drain hose
(80)

100
110

8
60 18

69
56
42 Drain hose
Air out 50 619 130
107
193

112
Air out

58 19

159

MSY-GE24VA MSY-GE26VA MSZ-GE60VA MSZ-GE71VA


INDOOR UNIT

1100
1090 5

238
Air in
Installation plate
5
325

Piping
67
12
100

76 843 181 65
3

( 70 ) 125 Drain hose


160
Air out 184

60 18
193

34
1-way cassette Unit : mm
MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
INDOOR UNIT
(Top) (Top)
Center of ceiling opening,
49.7 13.5 Center of ceiling opening, suspension bolt pitch suspension bolt pitch and grille
and grille are located in one position. Wireless are located in one position.

38
15
remote controller

26
58

414 Outer side of grille


2

384 Ceiling opening


308 Suspension bolt pitch
58 18

Suspension bolt pitch


Pipe
2 cover

230

308
158
180

Electrical box

Drain hose 15
(51.6)

38
15
Air outlet

26
connecting part Air outlet
20 20 Outlet
1051 Suspension bolt pitch 54.5 1051 Suspension bolt pitch 54.5
20 1160 Ceiling opening 20
1200 Outer side of grille
(Right side)
360
(Front) Drain hose 244
1102 Drain hose
170
960 78 Gas pipe
(Front)
110 Suspension bolt M10
Liquid pipe
Drain pipe

180 or more

175
175
116
110

112
Pipe cover
60
25

31
Electrical box Drain pan Ceiling Ceiling surface Grille Ceiling surface
Outlet opening area 48
Display and surface
0.04m2 58 No gaps between receiving section
the ceiling surface and grille

Grille (MLP-440W)
34
1200
Receiving section
CL
R6
172.4
166.5
81.8
414

0 CL

166.5
173 6
R6
Hole position for the
installation of grille
0
10
466.5

466.5

35
4 -way cassette Unit : mm
PLA-RP50BA PLA-RP60BA PLA-RP71BA

INDOOR UNIT
950

Ceiling hole
20~45 860~910 20~45
810
Fresh air Suspension bolt pitch

20~45
intake hole 160

(7.5)
160

Remote controller
terminal block
Indoor unit/Outdoor

Suspension bolt pitch


unit connecting
Branch duct hole

Ceiling hole
terminal block

-5
Models

605 +35
A B C D

860~910
Branch duct hole
840

620
950

PLA-RP50BA

Indoor power supply 80


terminal block(optional part) 74
PLA-RP60BA 241 258
87

PLA-RP71BA 85 77
150

160
24
D
90
C

(7.5)

20~45
187.5 160
840
Suspension bolt
M10 or W3/8
Detail connecting of branch duct
Refrigerant pipe Drain pipe 90 100 100 90
60 284 377 Cut out hole
(liquid)

100
130
Refrigerant pipe
(gas)
70
A
B
190

155
167
156
170
140

105

Suspension bolt
50~70

lower edge Power supply wire,


17 +50
35

Ceiling 350
Control wire entry
Indoor unit/Outdoor unit 175 14- 2.8
connecting wire entry Grille
Keep approximately Burring hole pitch 150 Burring hole
10 to 15mm space Cut out hole
between unit ceiling
and ceiling slab.

36
Ceiling-concealed Unit : mm
SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
INDOOR UNIT 20 157.5
15 12 37 100 37

88
B (Suspension bolt pitch)
100X(E-1)=F

100XJ=K
D (Duct)

H
C
A
Air Air
outlet inlet

100
100

88
30
57

20
20

12
10
23

L- 2.9
2XE- 2.9
25

90

49 625 (Suspension bolt pitch) Air filter


Knockout hole 27
Suspension bolt hole
(Remote controller transmission line)
4-14X30 Slot

Refrigerant piping 700 Knockout hole 27


23 677 (Indoor/outdoor connecting line)
flare connection (liquid) Control box
10
23
25

102
150 (Duct)

170
100

200

2X2- 2.9 116 70 Terminal block

Refrigerant piping 270 Terminal block (Indoor/outdoor connecting line)


(Remote controller transmission line) Notes:
flare connection (gas)
Drain pipe(Spontaneous draining) 1. Use M10 bolts for suspension (purchase locally).
2. Keep service space for maintenance at the bottom.
Model A B C D E F H J K L 3. This chart is based on the SEZ-KD50VAL, which has three fans.
SEZ-KD25VAL 700 752 798 660 7 600 660 5 500 16 SEZ-KD25VAL and SEZ-KD35VAL have two fans,
SEZ-KD35VAL and SEZ-KD60VAL and SEZ-KD71VAL have four fans.
900 952 998 860 9 800 860 7 700 20
SEZ-KD50VAL 4. If an inlet duct is used, remove the air filter supplied with the unit,
SEZ-KD60VAL and install a locally purchased filter on the suction side.
1100 1152 1198 1060 11 1000 1060 9 900 24
SEZ-KD71VAL

37
MXY SERIES MXZ SERIES Unit : mm
MXY-2E20VA MXZ-2C52VA MXY-3A28VA MXZ-3C68VA
OUTDOOR UNIT OUTDOOR UNIT

400 169 500 171


Drain hole
Air in 63.2 233.1 288

17.7
31.3
Air in
44

16.8
304 325

344.5

18.3
Air in

(Bolt Pitch)
17.5

360.6

396
Air in

12.3
40
Air out
Air out

17.7
2-10x21 Oval hole Drain holes

4-10 x 21 Oval hole


22.3 23 285 13 (Base bolt M10)

handle 840 30
200 30 330 13
550

Liquid pipe B unit 27.1


51 51 51

Gas pipe connection

240
Indoor and outdoor
connect wiring
Liquid pipe
251.1
280

A unit 39 x 27 hole
Gas pipe connection
66.3
Gas pipe

710
302.5 170.4
10

C unit connection
150 500

440
B unit connection

225
360

45
800 69
A unit connection

84
299 23.1 Liquid pipe

MXY- 4A28VA MXZ- 4C71VA MXY-4A38VA MXZ-4C80VA MXZ-5C100VA


OUTDOOR UNIT OUTDOOR UNIT

200 500 200


169 500 171
63.2 233.1 288 35 250 270 2 U-shaped notched hole
(Base bolt M10)
17.7
31.3

Air in
16

Air in
27
35
16.8

74

11
18.3

(Bolt pitch)
(Bolt Pitch)

355

387

Air in
360.6

396

Air in
24

Drain holes
12.3

Drain holes
40

16

Air out
2-12 x 36 Oval hole
Air out (Base bolt M10)
17.7

4-10 x 21 Oval hole


(Base bolt M10)
900 30 320 10

840 30 Handle Indoor and


200 30 330 13 Handle outdoor
connect Gas pipe
wiring
(35 x 53) hole 88 E unit connection
27.1
(MXZ-5C100VA)
240

Indoor and outdoor


66.3
900

connect wiring
39 x 27 hole
D unit connection
405

Gas pipe C unit connection


597

D unit connection B unit connection


710

460

45

C unit connection
A
A unit connection
315

132
440

B unit connection
360

45

317 23
A unit connection
84

Liquid pipe
299 23.1

Liquid pipe

38
Unit : mm
MXZ-6C120VA
OUTDOOR UNIT

200 500 200 2-U Shaped Notched Hole


(Foundation Bolt M10)
450
Rear Air

27
16
48

Intake

11

(Bolt Pitch)
355

387
Side Air Intake
24

Air
16

42 Drain Hole
40

Discharge

2-12 x 36 Oval Hole


(Foundation Bolt M10)

900 21 320 5

Connecting
Wire Hole
(36 x 96)
Handle

70
Handle LIQ
Unit F
GAS
LIQ
Unit E
1070

GAS
65

LIQ
Unit D
GAS LIQ 6.35(1/4")FLARE
515

LIQ GAS 9.52(3/8")FLARE


730

Unit C
GAS
LIQ
548

Unit B
45

GAS
LIQ LIQ 6.35(1/4")FLARE
Unit A GAS 12.7(1/2")FLARE
GAS
125

340 34

39
Piping Installation
MXY SERIES MXZ SERIES
MXY-2E20VA MXZ-2C52VA
Maximum Piping Length Indoor a Maximum height
units difference
Outdoor unit - Indoor unit (a,b) 20m
Total length (a+b) 30m
Outdoor Outdoor unit

Maximum Number of Bends


|

unit Indoor unit


15m
Outdoor unit - Indoor unit (a,b) 20 *Outdoor unit
installed lower Indoor unit
|

Total number (a+b) 30 Indoor unit


15m

Outdoor unit
|
Indoor unit
b 10m
*Outdoor unit
installed higher

Highest
MXY-3A28VA MXZ-3C68VA Indoor Maximum height
Maximum Piping Length units a
difference
Outdoor unit - Indoor unit (a,b,c) 25m
Total length (a+b+c) 60m
b Outdoor Outdoor unit
|
unit Indoor unit
Maximum Number of Bends 15m
*Outdoor unit
Outdoor unit - Indoor unit (a,b,c) 25 installed lower
Indoor unit
Total number (a+b+c) 60 |
Indoor unit
15m
Outdoor unit
Lowest
|
Indoor unit
c
10m
*Outdoor unit
installed higher

40
MXY-4A28VA MXZ-4C71VA
Indoor
Maximum Piping Length units Highest Maximum height
Outdoor unit - Indoor unit (a,b,c,d) 25m a difference
Total length (a+b+c+d) 60m

b Outdoor
Maximum Number of Bends unit Outdoor unit
|
Indoor unit
Outdoor unit - Indoor unit (a,b,c,d) 25 15m
*Outdoor unit
Total number (a+b+c+d) 60 installed lower Indoor unit
|

c Indoor unit
15m

Outdoor unit
MXY-4A38VA MXZ-4C80VA Lowest d
|
Indoor unit
Maximum Piping Length 10m
*Outdoor unit
installed higher
Outdoor unit - Indoor unit (a,b,c,d) 25m
Total length (a+b+c+d) 70m

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c,d) 25
Total number (a+b+c+d) 70

Indoor Maximum height


MXZ-5C100VA units Highest
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e) 25m
Outdoor
Total length (a+b+c+d+e) 80m b unit
Outdoor unit
|
Indoor unit
Maximum Number of Bends c 15m
*Outdoor unit
Outdoor unit - Indoor unit (a,b,c,d,e) 25 installed lower Indoor unit
|
Indoor unit
Total number (a+b+c+d+e) 80 15m
Outdoor unit
|
Lowest Indoor unit
10m
d e
*Outdoor unit
installed higher

Highest
Indoor e Maximum height
MXZ-6C120VA units
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25m
Outdoor
Total length (a+b+c+d+e+f) 80m b unit Outdoor unit
|
Indoor unit
15m
Maximum Number of Bends c *Outdoor unit
installed lower Indoor unit
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25 |
Indoor unit

Total number (a+b+c+d+e+f) 80 15m

Outdoor unit
|
Lowest Indoor unit
10m
d f
*Outdoor unit
installed higher

41
42
SERIES

Easy to transport and Flexible choice and suitable for


Light weight Smaller footprint

Easy to transport by elevator


install at site. the limited outdoor space.

8HP New S series 8HP


By the entrance On the balcony Extended residence space.

Light and easy to carry

Welc
om e
4HP x 2units 8HP x 1units
New S series can maximize
residential area.

The two-pipe zoned system designed for Heat


Pump Operation
The CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to
heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refriger-
ant and an INVERTER-driven compressor to use energy effectively.
With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured
for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's
design options. This feature allows easy air conditioning in each area with convenient individual controllers.

[P112~140(V/YKM)] Outdoor unit

Refrigerant Piping Lengths Maximum meters


Residence Total length 300
Furthest piping length
Maximum allowable length 150 (175 equivalent)
175m
Farthest indoor from first branch 30 Top-bottom
(equivalent length)
differential
(actual length 150m)
50m
Vertical differentials between units Maximum meters
Between indoor units
top-bottom differential
Indoor/outdoor (outdoor higher) 50 15m
Indoor/outdoor (outdoor lower) 40
Indoor/indoor 15 Indoor unit

[P175~225(YKM)] Outdoor unit

Refrigerant Piping Lengths Maximum meters


Outdoor unit
Total length 150
Furthest piping length
Maximum allowable length 80 (90 equivalent)
90m
Farthest indoor from first branch 30 Top-bottom
(equivalent length)
differential
(actual length 80m)
50m
Vertical differentials between units Maximum meters
Between indoor units
Silent mode can reduce sound
top-bottom differential
pressure level by 3dB(A) Indoor/outdoor (outdoor higher) 50 15m
Indoor/outdoor (outdoor lower) 40
Indoor/indoor 15 Indoor unit

43
Advanced
Energy-saving
Technologies S series PUMY-P VKM
PUMY-P YKM

Highly efficient fan and grille for outdoor unit

The shapes of the fan and grille of the outdoor unit have been rede-
signed, realising an increase in blowing capacity and more efficient heat
exchange while maintaining the same operating noise level.

Outdoor unit fan opening increased


The diameter of the opening for the fan in the outdoor unit has been in-
Opening increased
creased from 490 to 550mm. Blowing capacity has been increased from 490 to 550mm
while maintaining the same fan rotation speed. in diameter

Grille shape changed Inflexed fan


The shape of the air Adoption of a fan with improved ventilation characteris-
outlet grille has been tics and a newly designed rear edge that suppresses
c h a n g e d to r e d u c e wind turbulence raises fan operation efficiency.
pressure l o s s. T h i s
has helped to improve
heat exchange perfor-
mance.
PUMY-P V/YHMB PUMY-P V/YKM Fan rear edge

Highly efficient heat exchanger

A high density and increase in surface area have improved the heat-exchange efficiency
of the heat exchanger.

High-density heat exchanger 2 lines, 52 columns

2 lines, 64 columns
The pipe diameter has been changed from 9.52 to 7.94mm, resulting
in a high-density heat exchanger.
(image) Increase in heat-exchanger surface area

Heat-exchange surface area increased


Heat exchanger size extended horizontally, increasing the Heat exchanger Heat exchanger
surface area. PUMY-P V/YHMB PUMY-P V/YKM

Heat Cooling operation


Heat Interchanger (HIC) Added Interchanger
(HIC)

A Indoor
A HIC circuit has been added to improve energy effi- HEX

ciency during cooling operation. Liquid refrigerant is Accumulator Outdoor


HEX
LEV B
rerouted, transformed into a gas state and injected A Compressor

back into the system to increase overall pressure of


LEV C LEV A
the refrigerant being sent to the compressor, thereby Heat
interchanger(HIC)

reducing the load on the compressor and raising effi- w/ HIC circuit
w/o HIC circuit
ciency.
I_current HIC without to increase the heat
I_new exchange volume with increasing I.

44
Easy to transport and Flexible choice and suitable for
Light weight Smaller footprint

Easy to transport by elevator


install at site. the limited outdoor space.

8HP New S series 8HP


By the entrance On the balcony Extended residence space.

Light and easy to carry

Welc
om e
4HP x 2units 8HP x 1units
New S series can maximize
residential area.

The two-pipe zoned system designed for Heat


Pump Operation
The CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to
heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refriger-
ant and an INVERTER-driven compressor to use energy effectively.
With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured
for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's
design options. This feature allows easy air conditioning in each area with convenient individual controllers.

[P112~140(V/YKM)] Outdoor unit

Refrigerant Piping Lengths Maximum meters


Residence Total length 300
Furthest piping length
Maximum allowable length 150 (175 equivalent)
175m
Farthest indoor from first branch 30 Top-bottom
(equivalent length)
differential
(actual length 150m)
50m
Vertical differentials between units Maximum meters
Between indoor units
top-bottom differential
Indoor/outdoor (outdoor higher) 50 15m
Indoor/outdoor (outdoor lower) 40
Indoor/indoor 15 Indoor unit

[P175~225(YKM)] Outdoor unit

Refrigerant Piping Lengths Maximum meters


Outdoor unit
Total length 150
Furthest piping length
Maximum allowable length 80 (90 equivalent)
90m
Farthest indoor from first branch 30 Top-bottom
(equivalent length)
differential
(actual length 80m)
50m
Vertical differentials between units Maximum meters
Between indoor units
Silent mode can reduce sound
top-bottom differential
pressure level by 3dB(A) Indoor/outdoor (outdoor higher) 50 15m
Indoor/outdoor (outdoor lower) 40
Indoor/indoor 15 Indoor unit

45
Advanced
OUTDOOR UNIT S Series
Specifications

Model PUMY-P112VKM PUMY-P125VKM PUMY-P140VKM PUMY-P112YKM PUMY-P125YKM

Energy-saving
Power source 1-phase 220-240V 50Hz 1-phase 220-240V 50Hz 1-phase 220-240V 50Hz 3-phase 380-415V 50Hz 3-phase 380-415V 50Hz
Cooling capacity *1 kW 12.5 14.0 15.5 12.5 14.0
(Nominal) *1 BTU / h 42,700 47,800
42,700 47,800 52,900
Power input kW 2.79 3.46 4.52 2.79 3.46
Current input A 12.87-12.32-11.80 15.97-15.27-14.64 20.86-19.95-19.12 4.46-4.24-4.09 5.53-5.26-5.07
EER kW / kW 4.48 4.05 3.43 4.48 4.05
Temp. range of Indoor temp. W.B. 15.0~24.0°C 15.0~24.0°C 15.0~24.0°C 15.0~24.0°C 15.0~24.0°C

Technologies
cooling
Outdoor temp. D.B. -5.0~46.0°C -5.0~46.0°C -5.0~46.0°C -5.0~46.0°C -5.0~46.0°C
Heating capacity *2 kW 14.0 16.0 18.0 14.0 16.0
(Nominal)
*2 BTU / h 47,800 54,600 61,400 47,800 54,600
Power input kW 3.04 3.74 4.47 3.04 3.74
Current input A 14.03-13.42-12.86 17.26-16.51-15.82 20.63-19.73-18.91 4.86-4.62-4.45 5.98-5.68-5.48
COP kW / kW 4.61 4.28 4.03 4.61
S series PUMY-P
4.28
VKM
Temp. range of
heating
Indoor temp. D.B. 15.0~27.0°C 15.0~27.0°C 15.0~27.0°C 15.0~27.0°C PUMY-P YKM
15.0~27.0°C
Outdoor temp. W.B. -20.0~15.0°C -20.0~15.0°C -20.0~15.0°C -20.0~15.0°C -20.0~15.0°C
Indoor unit Total capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity
connectable P15~P140 / 9 P15~P140 / 10
Model / Quantity P15~P140 / 9 P15~P140 / 10 P15~P140 / 12
Sound pressure level
(measured in anechoic room) dB <A> 49 / 51 50 / 52 51 / 53 49 / 51 50 / 52

9.52 Flare 9.52 Flare


Highly mm
efficient15.88fan
Flare and grille15.88
for Flare outdoor unit
Refrigerant piping Liquid pipe mm 9.52 Flare 9.52 Flare 9.52 Flare
diameter
Gas pipe 15.88 Flare 15.88 Flare 15.88 Flare
FAN Air flow rate m3 /min 110 110 110 110 110
L/s 1,833 1,833 1,833 1,833 1,833
The shapes of cfm the fan and 3,884
grille of the outdoor 3,884
unit have been rede- 3,884 3,884 3,884
External dimension HxWxDsigned, realising mm
an increase in blowing capacity
1,338 x 1,050 x 330 (+25)
and more efficient
1,338 x 1,050 x 330 (+25)
heat
1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25)

Refrigerant
exchange while
Type x original charge
maintaining the
R410A 4.8kg
same operating noise
R410A 4.8kg
level. R410A 4.8kg R410A 4.8kg R410A 4.8kg
Net weight kg 123 123 123 125 125

Outdoor unit fan opening increased


Notes: *1,*2 Nominal conditions
Model The diameter of the opening
PUMY-P140YKM for the fan in the outdoor unit has been
PUMY-P175YKM in-
PUMY-P200YKM PUMY-P225YKM
Opening increased
Indoor Outdoor
Power source creased from 490 to 550mm.
3-phase Blowing capacity
380-415V 50Hz has
3-phase 380-415V 50Hz been increased
3-phase 380-415V 50Hz 3-phase 380-415V 50Hz
from 490
Cooling 27ºCto 550mm
DB/19ºCWB 35ºC DB
Cooling capacity *1 kW 15.5 20.0 22.4 25.0
(Nominal) while maintaining
*1 BTU / h
the same fan rotation speed. 68,200
52,900 76,400 85,300
in diameter
Heating 20ºC DB 7ºC DB/6ºC WB
Power input kW 4.52 5.48 6.91 9.62
Current input A 7.23-6.87-6.62 8.95-8.51-8.20 11.29-10.72-10.34 15.72-14.93-14.39
Grille
EER shape
kW / kW changed
3.43 3.65 3.24 Inflexed fan 2.60
Pipe length Level difference

Temp. range of Indoor temp. W.B. 15.0~24.0°C 15.0~24.0°C 15.0~24.0°C 15.0~24.0°C Cooling 7.5m 0m
cooling
Outdoor temp. D.B.
The shape of the air -5.0~46.0°C -5.0~46.0°C -5.0~46.0°C -5.0~46.0°C
Adoption of a fan with improvedHeating
ventilation 7.5m
characteris- 0m
Heating capacity *2 kW 18.0 22.4 25.0 27.3
(Nominal) outlet grille *2 BTUhas / h been 61,400 76,400 85,300 tics and a newly93,200
designed rear*Nominal
edge that suppresses
condition *1,*2 are subject to ISO 15042.

cPower
h a ninput
g e d to kW reduce 4.47 5.73 6.96 wind turbulence raises
7.65 fan operation efficiency.
*Due to continuing improvement, above specification
may be subject to change without notice.
Current input A 7.15-6.79-6.55 9.36-8.89-8.57 11.37-10.80-10.41 12.50-11.87-11.44
pressure
COP
l o s s.
kW / kW
T h i s 4.03 3.91 3.59 3.57
*3 Liquid pipe diameter:12.7mm in case of farthest
piping length is longer than 60m.
Temp. range of has
Indoorhelped
temp. toD.B.
improve 15.0~27.0°C 15.0~27.0°C 15.0~27.0°C 15.0~27.0°C
heating -20.0~15.0°C -20.0~15.0°C -20.0~15.0°C -20.0~15.0°C
Outdoor temp. W.B.
heat exchange perfor-
50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity
Indoor unit Total capacity
connectable mance.
Model / Quantity P15~P140 / 12 P15~P224 / 12 P15~P250 / 12 P15~P250 / 12
Sound pressure level
(measured in anechoic room) dB <A> 51 PUMY-P
/ 53 V/YHMB 56/PUMY-P
61 V/YKM 56 / 61 58 / 63 Fan rear edge
Refrigerant piping Liquid pipe mm 9.52 Flare 9.52 Flare *3 9.52 Flare *3 9.52 Flare *3
diameter
Gas pipe mm 15.88 Flare 22.2 Brazed 22.2 Brazed 22.2 Brazed
FAN Air flow rate m3 /min 110 134 134 143.8

Highly efficient heat exchanger


L/s 1,833 2,233 2,233 2,397
cfm 3,884 4,732 4,732 5,078
External dimension HxWxD
mm 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25)
A high density and increase in surface area have improved the heat-exchange efficiency
Refrigerant Type x original charge R410A 4.8kg R410A 7.3kg R410A 7.3kg R410A 7.3kg
Net weight of the heat exchanger. kg 125 138 138 138

High-density heat exchanger 2 lines, 52 columns


External The
Dimensions
pipe diameter has been changed from 9.52 to 7.94mm, resulting 2 lines, 64 columns Unit : mm
PUMY-P112V(Y)KM PUMY-P125V(Y)KM
in a high-density heat exchanger. PUMY-P140V(Y)KM
PUMY-P175YKM PUMY-P200YKM PUMY-P225YKM (image) Increase in heat-exchanger surface area

OUTDOORHeat-exchange
UNIT surface area increased
Heat exchanger size extended horizontally, increasing the 1050
Terminal connection
From left to right Heat exchanger Heat exchanger
For the *1 For the For concentration
Rear Air Intake
For the
Ground for the power supply power supply transmission line control
2-U Shaped notched holes 362 ("GR"marking position)
branch box
power supply

surface area.
225 600 225
(Foundation Bolt M10)

PUMY-P V/YHMB PUMY-P V/YKM


Installation Feet
19

Ground for the transmission line


Ground for concentration control
Side Air Intake
1 Refrigerant GAS pipe connection
PUMY-P112/125/140V(Y)KM:(Flare) 15.88
330

417
370

Ground for *1
the branch box
Heat power supply Cooling operation
PUMY-P175/200/225YKM:(attached JOINT) 22.2
Heat Interchanger (HIC) Added
56
33
0 Interchanger 2 Refrigerant LIQUID pipe connection
53
42 (HIC) Service panel :(Flare) 9.52
25

28

56(60*) Handle for


632

Handle for
1338

moving moving
70(75*)
Air Discharge 2-12×36 Oval holes
A Indoor
A HIC circuit has been added to improve energy effi-
(Foundation Bolt M10)
Air Intake HEX
A

*1 PUMY-P112/125/140V(Y)KM only.
ciency during cooling operation. Liquid refrigerant is STOP VALVE connectionOutdoor
*2 Indication ofAccumulator location.
HEX
LEV B *3 PUMY-P175/200/225YKM:(Flare) 19.05(3/4F)
rerouted,* PUMY-P175/200/225YKM
transformed into a gas state and injected 1 A Compressor
C *2*3

Model A B C
B *2

2
back into the system to increase overall pressure of
369

PUMY-P112/125/140VKM 1062A
LEV 510 426
26

LEV C
the refrigerant being sent to the compressor, thereby Front piping cover
Heat
PUMY-P112/125/140YKM interchanger(HIC)
909 510 426

reducing the load on the compressor and raising effi- Rear piping cover
w/ HIC circuitPUMY-P175/200/225YKM 986 450 393
w/o HIC circuit
ciency.
I_current HIC without to increase the heat
I_new exchange volume with increasing I.

46
Wide Selection of Indoor Units
Model name Model name Model P15 P20 P25 P32

4-way air flow PLFY-P VBM-E


Ceiling
Cassette
PLFY-P VCM-E2

2-way air flow PLFY-P VLMD-E

1-way air flow PMFY-P VBM-E

PEFY-P VMR-E-L/R
Ceiling Concealed

PEFY-P VMS1(L)-E

PEFY-P VMA(L)-E

PEFY-P VMA3-E

PEFY-P VMH(S)-E

Fresh Air PEFY-P VMH-E-F


Intake

PCFY-P VKM-E
Ceiling
Suspended
PKFY-P VBM-E
Wall Mounted

PKFY-P VHM-E

PKFY-P VKM-E

PFFY-P VKM-E2
Floor Standing/
Floor Mounted
Concealed
PFFY-P VLEM-E

PFFY-P VLRM-E
PFFY-P VLRMM-E

47
P40 P50 P63 P71 P80 P100 P125 P140 P200 P250

48
System Controller
Mitsubishi Electric's Air-conditioner Network System (MELANS) introduces an era of air conditioner management
via PC browsers connected to a Network.

MELANS
Use of our MELANS products enhances EFFICIENCY and QUALITY of air-conditioning, contributing to ENERGY SAVING and
reduction in running cost. We offer a wide variety of MELANS products to meet all requirements - from the smallest and simplest to
the largest and most complex.
We have individual remote controllers, various centralized controllers, and centralized integrated software, as well as BMS interface
hardware and software etc. Above all, with AE-200E/AE-50E/AG-150A/EB-50GU-J/GB-50ADA-J, PC browser and long distance
remote control (monitoring and operating) via communication Network is possible and easy.

I ndividual Remote Controller C entralized Remote Controller


All of the local remote controllers feature liquid Advanced
crystal and LED displays and easy to operate. Touch NEW
Controller NEW

Remote Simple Wireless Remote AE-200E/AE-50E AG-150A


Controller Remote Controller
Controller AT-50B

ON/OFF
Remote
Controller EB-50GU-J
PAC-YG50ECA
M-NET

PAR-31MAAE
PAC-YT52CRA

GB-50ADA-J
PAR-FL32MA PAR-FA32MA
PAC-YT40ANRA
AHC ADAPTER
PAR-U02MEDA

*1

PAR-SA9FA-E PAR-SL94B-E
PAC-IF01AHC-J

PI Controller

PAC-YG60MCA

DIDO Controller
OUTDOOR UNIT INDOOR UNIT
S : PUMY PLFY PCFY
Y : PUCY/PUHY PMFY PKFY
PEFY PFFY PAC-YG66DCA

AI Controller

PAC-YG63MCA
Interface Interface
*1. Advanced HVAC CONTROLLER

BAC-HD150

A ir-Conditioning
LMAP04-E

Control System
This is a specialized air condition-
BACnet ® *1
LONWORKS ® *2
ing management system, in which
transmission line transmission line
(Ethernet) up to 2000 indoor units can be
centrally controlled.
Mitsubishi Electric's Integrated centralized
CITY MULTI can be easily control software
connected to the building TG-2000A
management system through
BACnet .
Ethernet
Integrated centralized
control software TG-2000A

*Some controllers cannot be used in combination with certain models of devices.


*1 BACnet ® is a registered trademark of ASHRAE.
*2 LonWorks® is a trademark of Echelon Corporation registered in the United States and other countries.
49
The NewStructure
System Cooling-only Models
In
Mitsubishi
an easy and
Electric
flexible
offers
manner
a widewith
lineup
our of
new newCentralized
cooling-only
Controller
modelsAE-200E,
with themaximum
an optimum
capacity
systemofcan
54 be
HP*. Different
established
patterns of combinations
according to the
of basic
scale modules
of facilities.
provide either standard or high COP.
*Applicable to standard model combinations only

Requires 10HP 10HP No need for 20HP


Single module up 20 HP joint work joint work

Capable
Buildingof coveringsystem
management up to 20 HP with a single module and a single
BMS
compressor. Reduced piping work.
Field-installed
Field-installed
PC
HUB
BACnet®
Tablet
Compatibility to outdoor temperature
To be connectable with
BACnet ® *1
All modules feature inverter-driven compressors.
Router
of up to 52°C*1 Maximum combined horse power: 60 HP
Capable of running cooling operations 52ºC
in the outdoor
HUB temperature
HUB of up to Current New
52°C*. M-NET M-NET
LAN2
*Compared to 46°C of the older model
LAN1

group 1 group 2
AE-200E

M-NET
Increase in the limit of piping length
LAN1 : For air conditioning systems
LAN2 : For BACnet®
Farthest indoor from first branch: 90 m Height difference
group 3 group 4
between indoor and indoor units is up to 30 m.

First Branch

Power supply unit


Max height (PAC-SC51KUA)

30m
General Equipment
*2
DIDO Controller (PAC-YG66DCA)

Max length

90m*3 Temp/Humidity sensor

AI Controller (PAC-YG63MCA)
Lights Ventilation Security card reader

Watt hour meter

PI Controller (PAC-YG60MCA)

Standard or high COP options are available


by different combinations
LAN2
of modules.
LAN1
Farthest indoor from first branch: 90 m Height difference
AE-50E
between indoor and indoor units is up to 30 m.

LAN2
S L
LAN1 XL
AE-50E

LAN2
LAN1

HP 8 10 12 14 16 18 AE-50E20

example : 30HP S + L S + S + L

COP COP
3.33 3.88 *1. Please contact your local distributor for when the feature is supported.

Standard HighCOP
model model
12 + 18 = 30 8 + 8 + 14 = 30

*1 : Any continuous operation over 46ºC may require an increased frequency of maintenance.
*2 : When the height difference is 15m or greater, use the one size larger liquid pipe between the indoor unit and the indoor unit.
*3 : When the piping length is 40m or longer, use the one size larger liquid pipe between the indoor unit and the first branch.

50