Anda di halaman 1dari 2

Update

AccuLoad II SEQ


Programming Workbook
Issue/Rev. 0.0 (12/98) Bulletin AB06030U9

This update applies to the Programming Workbook (Bulletin AB06030 Issue/Rev. 0.6 (5/96)) for all AccuLoad IIs
that are operating with AccuLoad II - SEQ Version 19 and above firmware.

The version 19 firmware provides the capability for a component overrun alarm to be programmed for each
component in the recipe. A new command code 213 has been added to each of the Product Flow Control
Directories that allows the operator to program in whole units the amount of overrun that is allowed for each of the
products. If the component overruns its preset value by the amount programmed, the component overrun alarm
(CO) will be set for that component.

Also available with the version 19 firmware is the capability for the AccuLoad II SEQ firmware to communicate
with the Gate City Mini-Pak Injectors. This option has been added to System Parameter 041.

System Directory
Program Program
Code Function Description Entry Code

041 Additive System Enter: "0" Piston Injectors 041


and Pacing Control "1" Titan w/Pulse
Selection "2" Titan w/Comm
"3" Gate City w/Pulse
"4" Gate City w/Comm
“5” Mini-Pak w/Pulse*
“6” Mini-Pak w/Comm* __

Note: *These options apply to SEQ-19 and above firmware.

102 Product 1 Alarm Check/Reset Read only, Press E to clear None 102

Available Alarms

BH: Blend High HP: High Pressure


BL: Blend Low HT: High Temperature
BP: Back Pressure LD: Low Density
BV: Block Valve Fault LF: Low Flow
CO: Comp Overrun * LP: Low Pressure
HD: High Density LT: Low Temperature
HF: Excess High Flow
Note: This alarm available in SEQ-19 and above firmware.

Smith Meter Inc. The Most Trusted Name In Measurement


103 Product 2 Alarm Check/Reset Read only, Press E to clear None 103

Available Alarms

BH: Blend High HP: High Pressure


BL: Blend Low HT: High Temperature
BP: Back Pressure LD: Low Density
BV: Block Valve Fault LF: Low Flow
CO: Comp Overrun* LP: Low Pressure
HD: High Density LT: Low Temperature
HF: Excess High Flow

Note: This alarm available in SEQ-19 and above firmware

104 Product 3 Alarm Check/Reset Read only, Press E to clear None 104

Available Alarms

BH: Blend High HP: High Pressure


BL: Blend Low HT: High Temperature
BP: Back Pressure LD: Low Density
BV: Block Valve Fault LF: Low Flow
CO: Comp Overrun* LP: Low Pressure
HD: High Density LT: Low Temperature
HF: Excess High Flow
Note: This alarm available in SEQ-19 and above firmware

105 Product 4 Alarm Check/Reset Read only, Press E to clear None 105

Available Alarms

BH: Blend High HP: High Pressure


BL: Blend Low HT: High Temperature
BP: Back Pressure LD: Low Density
BV: Block Valve Fault LF: Low Flow
CO: Comp Overrun* LP: Low Pressure
HD: High Density LT: Low Temperature
HF: Excess High Flow
Note: This alarm available in SEQ-19 and above firmware

Product Directory
Program Program
Code Function Description Entry Code

213 Component Overrun Enter: Two (2) digits in whole 213


Alarm Limit units (e.g., 15)
"00" disables the alarm __ __
Note: This program code available in SEQ-19 and above firmware