21/10, 1518-1520(1975)
Peter Jatlow
05
w
U U
C
S S
0 0
I,
S
C A
I0
15
200 200 250 300 350
WAVELENGTH Inn,) WAVELENGTH Inn)
Fig. 1. Spectra obtained on analysIs of (a) plasma from pa- Fig. 3. Spectrum obtained on analysis of plasma from a pa-
tient receMng theophylline and (b) 10.0 mg/liter standard in tient receiving theophylline and phenobarbital
plasma
Human serum can be depleted of insulin and growth In radioimmunoassay for immunoreactive insulin in
hormone by treatment with dextran-coated charcoal or serum, an unknown serum is compared to a standard curve
by dialysis, or both. inclusion of such hormone-depleted prepared by use of increasing amounts of an insulin prepa-
serum in the standard curve of a double-antibody ra- ration that serves as a standard. The insulin standard is
dioimmunoassay for immunoreactive insulin more nearly usually dissolved in a buffer solution containing bovine (1)
mimics the conditions under which an unknown human or human (2) serum albumin as the only protein. The ab-
serum sample is assayed. Compared to the usual stan- sence of human serum from the standard is thus an uncon-
dard curve in which serum albumin is the only protein, trolled variable and might affect the absolute value of insu-
the addition of hormone-depleted serum can cause an lin determined in an unknown serum, particularly if it is
increase (by an average 64% under the conditions we assayed relatively undiluted. Because the absolute value
used) in the absolute value for apparent insulin in serum. for serum insulin is often used diagnostically (3), factors af-
The effect of hormone-depleted serum should be tested fecting its determination can be clinically important.
Therefore, we examined the effect of insulin-depleted
in the standard curves of double-antibody radioimmu-
human serum on the standard curve of a double-antibody
noassays and included routinely in these standard radioimmunoassay for immunoreactive insulin.
curves if it changes the results. When used in conjunc-
tion with an eventual reference standard for human in- Methods
sulin, this modification of the insulin assay may make
the measured values of human serum insulin from dif- Preparation of hormone-depleted human serum.
Human serum was treated with dextran-coated charcoal or
ferent laboratories more comparable.
dialyzed, or both.
Treatment with dextran-coated charcoal: (a) prepare a
Medical Service, Boston Veterans Administration Hospital; and
the Departments of Medicine of Boston University and Tufts Uni-
suspension of dextran-coated charcoal (4); (b) centrifuge at
versity Schools of Medicine, Boston, Mass. 02130. 10 000 X g for 10 mm at 4 #{176}C,
beginning with a volume of
Received April 11, 1975; accepted June 4, 1975. charcoal suspension four times that of the serum to be