Hamidreza Khakzad
h.khakzad@gmail.com
https : //www .researchgate.net/profile/Hamidreza−Khakzad
Outline
Hardware Description
3900 Series NodeB Overview
3900 Series NodeB Hardware
3900 Series NodeB Expansion
Configuration
MML(Man Machine Language)
GUI(Graphic User Interface)
Operation and Maintenance (OM)
OM System Overview
NodeB Routine OM
Exam
The End
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
General Features
NodeB
1. Macro NodeB (BTS) which includes BBU and RFU
I BTS3900 (In.): 1BBU + 6RFU
I BTS3900A (Out.): 1BBU + 6RFU
I BTS3900L (In.): 2BBU + 12RFU
I BTS3900AL (Out.): 2BBU + 9RFU + Some RRUs
I BTS3900C (Out.): 1BBU + 1RFU (mini BTS)
2. Distributed NodeB (DBS) which includes BBU and RRU
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900 (In.)
BTS3900 (In.)
I 3 Power can be received → −48 DC (DCDU), +24 DC
(DCDU+PSU), 110/220 AC (DCDU+PSU+PMU)
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900 (In.)
I Application → centralized installation, crowded street
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900A (Out.)
I 2 Cabinet
1. BBU → AC power: APM, DC power: TMC
2. RFU → RFC
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900A (Out.)
I Application → centralized installation, village, dessert
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900L (In.)
I 1 Cabinet → 4 Subrack (2BBU + 2RFU)
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900L (In.)
I Application → main street, crowded street
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900AL (Out.)
I 1 Cabinet → 3 Subrack (2BBU + 1RFU)
I Application → new BTS mostly used in Europian countries
where e.g. 5 frequency bands are used and the network is
more complicated.
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
BTS3900C (Out.)
BTS3900C (Out.)
Applications
I For temporary coverage e.g. in a conference room
I In environment such as tunnels, hot spots, places without
equipment rooms, and edge networks
I Can be installed on a pole, against a wall, or on the ground
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Overview
DBS3900
DBS3900
I Applications
1. high building
2. different direction
3. along the highways and railways (long-way)
4. urban and rural coverage (low population)
RAN14 NodeB Configuration, Operation and Maintenance h.khakzad@gmail.com
Hardware Description
3900 Series NodeB Overview
I Cabinet
1. BBU: 0 − 7
2. RFU/RRU: 0 − 62
I Subrack
1. BBU: 0 − 1
2. RFU: 4 − 5
3. RRU: 60 − 254
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
Contents
Slot Numbering
I WBBP: 0 − 5
I WMPT/UMPT: 6 − 7
I UBFA: 16
I UPEU: 18 − 19
I RFU: 0 − 8
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
Summary of Numbering1
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
Summary of Numbering2
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WMPT Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WMPT Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WMPT Board-LED
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WMPT Board-LED
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UMPT Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UMPT Board-LED
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WBBP Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WBBP Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WBBP Capacity
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UCIU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UTRP Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UBFA Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UPEU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UPEU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UPEU Board-Port
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UEIU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
UEIU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
Contents
RF Module
WRFU
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
WRFU
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
MRFU Board
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
RRU
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
Question:
How to connect the CPRI
I
Contents
DCDU-01
I The DCDU-01 supports one −48V DC power input and ten
−48V DC power outputs.
I The DCDU-01 supplies power to the BBU, RF modules, FAN
unit and user devices in the cabinet.
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
PSU (DC/DC)
I Converting +24V DC power to −48V DC power
I Monitoring alarms
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
PSU (AC/DC)
I Converting 220V AC power to −48V DC power
I Monitoring alarms
I Monitoring charging and discharging of batteries
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
PMU
I Power system management
I Power distribution detection
I Alarm report
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Hardware
FAN Unit
RAN14 NodeB Configuration, Operation and Maintenance
Hardware Description
3900 Series NodeB Expansion
Question:
How to configure NodeB
I
hardware to support 3
sectors, 6 cells and 50
subscribers/cell with
minimum boards (WBBPb3
is applied in this case)?
RAN14 NodeB Configuration, Operation and Maintenance
Configuration
MML(Man Machine Language)
MML
GUI
OM
I OM
1. Local (LMT)
2. Remote (M200)
I OM
1. MML (LMT,M200)
2. GUI (CME,M2000)
I LMT
1. Offline mode
2. Online mode
I User: admin, Pass: NodeB → WMPT
I User: admin, Pass: hwbs@com → UMPT
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
OM System Overview
OM System Structure
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
OM System Overview
OM Information
Operation
I System Management
I Alarm Management
I Equipment Management
I Cell Management
I Real-time Monitoring
I Software Management
I File Management
I Tracing Management
I Traffic Review
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
NodeB Routine OM
System Management
I Login
I IP address
I User name: admin
I Password: NodeB (for WMPT), hwbs@com (for UMPT)
I Common Operations
I Changing Log-In Password of LMT
I Locking/Unlocking LMT
I Executing MML command
1. Single MML command
2. Batch MML command
I Setting the properties of the system
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
NodeB Routine OM
System Management
System Management
I Executing batch MML command
Choose System > Batch Commands, or press Ctrl + E
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
NodeB Routine OM
System Management
System Management
System Management
Alarm Management
I Browsing alarm
Choose Fault Management > Browse Alarm
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
NodeB Routine OM
Alarm Management
Alarm Management-Shielding
Equipment Management
Equipment Management
Equipment Management
Equipment Management
Equipment Management
Software Management
I NodeB software
I NodeB BOOTROM: Firmware.csp
I NodeB software: Software.csp
I Cold patch software: SwCPatch.csp
I Hot patch software: SwHPatch.csp
RAN14 NodeB Configuration, Operation and Maintenance
Operation and Maintenance (OM)
NodeB Routine OM
Software Management
Software Management
File Management
File Management
File Management
Software Management
File Management
File Management
Tracing Management
Tracing Management