Anda di halaman 1dari 7

PARALELO

Sistema en paralelo

Calculo del head total

Q1 Hb1 Q2 Hb2 Qtotal Head paralelo


(m3/s) m (m3/s) m (m3/s) m
0.001142857 23.60076175 0.00100321 23.09357801 0.002146067 23.34716988
0.000985028 26.38523247 0.000855139 25.9835552 0.001840167 26.18439383
0.000833056 29.29993201 0.000700574 28.95267666 0.00153363 29.12630433
0.00061736 32.13363342 0.000581734 32.12360365 0.001199094 32.12861853

ARREGLO EN PARALELO
35

30

25
Head (m)

20 Hb1

15
Hb2
10

Head paralelo
5

0
0 0.0005 0.001 0.0015 0.002 0.0025
Q (m3/s)

Calculo de eficiencia de la bomba centrífuga:

Q Pconsumida Pmotor eficiencia


(m3/s) W W
0.0011429 264.0690581 1171.3 22.54%
0.000985 254.4537552 1116.05 22.80%
0.0008331 238.9682342 1049.75 22.76%
0.0006174 194.2218064 983.45 19.75%
Cálculo de eficiencia de la bomba autocebante:

Q Pconsumida Pmotor eficiencia


(m3/s) W W
0.00100321 226.8207306 1160.25 19.55%
0.000855139 217.5379504 1138.15 19.11%
0.000700574 198.5832328 1127.1 17.62%
0.000581734 182.9565368 1105 16.56%

Curvas de eficiencia de cada bomba en el arreglo paralelo

EFICIENCIA VS Q
25.00%

20.00%
Eficiencia %

15.00%

bomba centrífuga
10.00%
bomba autocebante

5.00%

0.00%
0 0.0002 0.0004 0.0006 0.0008 0.001 0.0012
Q (m3/s)

BOMBA 1
Calculo del caudal
𝑉𝑜𝑙𝑢𝑚𝑒𝑛 𝐵𝑎𝑠𝑒
𝑄1 =
𝑡

Cálculo del Número de Re y de la Rugosidad Relativa (ε/d):

Para calcular el Re, tomamos los datos respectivos y tenemos:

𝑄1
𝜌∗ ∗𝐷
(𝜋 ∗ 𝐷 2 )⁄
𝜌∗𝑣∗𝐷 4 4 ∗ 𝜌 ∗ 𝑄1
𝑅𝑒 = = =
𝜇 𝜇 𝜋∗𝜇∗𝐷
Calculamos la rugosidad Relativa

𝜀 0.00015
= = 0.006
𝐷 0.0266

Cálculo del Factor de Fricción de Darcy (f):


Utilizamos la ecuación de Zingrang y Sylvester

−2
𝜀 𝜀 𝜀
5.02 5.02 13
𝑓 = [−2 ∗ log ( 𝐷 − ∗ log ( 𝐷 − ∗ log ( 𝐷 + )))]
3.7 𝑅𝑒 3.7 𝑅𝑒 3.7 𝑅𝑒

Cálculo de Perdida primaria


Longitud de tubería del tramo 1-2
𝐿𝑡𝑜𝑡𝑎𝑙 = (18 + 91 + 24 + 19 + 13.5)/100𝑐𝑚 = 1.655𝑚

𝐿𝑡𝑜𝑡𝑎𝑙 𝑣2 𝐿𝑡𝑜𝑡𝑎𝑙 8 ∗ 𝑄1 2
ℎ𝑓−𝑃𝑟𝑖𝑚,𝑇𝐸𝑂𝑅 =𝑓∗ ∗ =𝑓∗ ∗( 2 )
𝐷 2∗𝑔 𝐷 𝜋 ∗ 𝐷4 ∗ 𝑔

Cálculo la Pérdida de Carga Secundaria


La pérdida de carga ocasionada la calculamos de la siguiente manera:

𝐿𝑒
𝐾 = 𝑓𝑡( )
𝐷
𝑣2
ℎ𝑓−𝑆𝑒𝑐𝑢𝑛𝑑 = 𝐾 ∗
2∗𝑔

Calculamos la perdida secundaria Total sumando las perdidas secundarias, tenemos lo siguiente:

ℎ𝑓−𝑆𝑒𝑐𝑢𝑛𝑑 = 3 ∗ ℎ𝑓 𝑢𝑛𝑖𝑜𝑛 𝑢𝑛 + ℎ𝑓 𝑇´𝑠 + 2 ∗ ℎ𝑓 𝐶𝑜𝑑𝑜𝑠 + ℎ𝑓 𝑉𝑎𝑙𝑣 𝑔𝑙𝑜𝑏𝑜 + ℎ𝑓 𝑠𝑎𝑙𝑖𝑑𝑎 𝑡𝑎𝑛𝑞𝑢𝑒

Ecuación General de energía:

𝐸1 + 𝐻𝐵1 = 𝐸2 + ℎ𝑓 𝑃𝑟𝑖𝑚𝑎𝑟𝑖𝑎 + ℎ𝑓 𝑆𝑒𝑐𝑢𝑛𝑑𝑎𝑟𝑖𝑎

𝑃1 𝑣1 2
𝐸1 = + + 𝑍1
𝜌∗𝑔 2∗𝑔

𝑃1 = 0
𝑣1 ≈ 0
𝑍1 = 0.6𝑚
𝐸1 = 0.6 𝑁 𝑚⁄𝑁

𝑃2 𝑣2 2
𝐸2 = + + 𝑍2
𝜌∗𝑔 2∗𝑔

𝑍2 = 0.2
Reemplazando en la ecuación General de Energía:

𝐻𝐵1 = 𝐸2 + ℎ𝑓 𝑃𝑟𝑖𝑚𝑎𝑟𝑖𝑎 + ℎ𝑓 𝑆𝑒𝑐𝑢𝑛𝑑𝑎𝑟𝑖𝑎 − 𝐸1

Calculamos La potencia consumida:


𝑃𝐶𝑜𝑛𝑠𝑢𝑚𝑖𝑑𝑎 𝐵𝑜𝑚𝑏𝑎 1 = 𝐻𝐵1 ∗ 𝜌 ∗ 𝑔 ∗ 𝑄

Calculo de la potencia del motor


𝑃𝑚𝑜𝑡𝑜𝑟 = 𝑉 ∗ 𝐼𝑝𝑟𝑜𝑚

Calculo de la eficiencia
𝑃𝐶𝑜𝑛𝑠𝑢𝑚𝑖𝑑𝑎
𝑛=
𝑃𝑚𝑜𝑡𝑜𝑟

t vol(m3) Q Velocidad Re f hfp hfs hf total


s m3 (m3/s) (m/s) m m m
43.75 0.05 0.00114286 2.05654292 58218.1299 0.0329594 0.4420508 2.21599954 2.65805033
50.76 0.05 0.00098503 1.77253256 50178.1557 0.03317736 0.33055799 1.64619983 1.97675783
60.02 0.05 0.00083306 1.49906286 42436.5742 0.03345973 0.2384402 1.17742648 1.41586668
80.99 0.05 0.00061736 1.11092422 31448.8601 0.03407761 0.13336912 0.64664062 0.78000974

Presion Presion E1 E2 Hb1 Pconsumida Pmotor eficiencia


Psi (Pa) m m m W W
30 206842.8 0.6 21.5427114 23.6007618 264.069058 1171.3 22.54%
35 241316.6 0.6 25.0084746 26.3852325 254.453755 1116.05 22.80%
40 275790.4 0.6 28.4840653 29.299932 238.968234 1049.75 22.76%
45 310264.2 0.6 31.9536237 32.1336334 194.221806 983.45 19.75%
EFICIENCIA VS Q
23.50%

23.00%

22.50%
EFICIENCIA (%)

22.00%

21.50%

21.00% bomba centrifuga

20.50%

20.00%

19.50%
0 0.0002 0.0004 0.0006 0.0008 0.001 0.0012
Q (m3/s)

BOMBA 2
Se usan los mismos cálculos que el caso anterior para Q, Re y f

Cálculo de Perdida primaria


Longitud de tubería del tramo 1-3
𝐿𝑡𝑜𝑡𝑎𝑙 (18 + 26 + 71 + 10 + 20.5 + 20 + 11.5)/100 = 1.77𝑚

𝐿𝑡𝑜𝑡𝑎𝑙 𝑣2 𝐿𝑡𝑜𝑡𝑎𝑙 8 ∗ 𝑄1 2
ℎ𝑓−𝑃𝑟𝑖𝑚,𝑇𝐸𝑂𝑅 = 𝑓 ∗ ∗ =𝑓∗ ∗( 2 )
𝐷 2∗𝑔 𝐷 𝜋 ∗ 𝐷4 ∗ 𝑔

Cálculo la Pérdida de Carga Secundaria


La pérdida de carga ocasionada la calculamos de la siguiente manera:

𝐿𝑒
𝐾 = 𝑓𝑡
𝐷
𝑣2
ℎ𝑓−𝑆𝑒𝑐𝑢𝑛𝑑 = 𝐾 ∗
2∗𝑔
Calculamos la perdida secundaria Total sumando las perdidas secundarias, tenemos lo siguiente:

ℎ𝑓−𝑆𝑒𝑐𝑢𝑛𝑑 = 3 ∗ ℎ𝑓 𝑢𝑛𝑖𝑜𝑛 𝑢𝑛 + 2 ∗ ℎ𝑓 𝑇´𝑠 + 2 ∗ ℎ𝑓 𝐶𝑜𝑑𝑜𝑠 + ℎ𝑓 𝑉𝑎𝑙𝑣 𝑔𝑙𝑜𝑏𝑜 + ℎ𝑓 𝑠𝑎𝑙𝑖𝑑𝑎 𝑡𝑎𝑛𝑞𝑢𝑒

Ecuación General de energía:

𝐸1 + 𝐻𝐵2 = 𝐸3 + ℎ𝑓 𝑃𝑟𝑖𝑚𝑎𝑟𝑖𝑎 + ℎ𝑓 𝑆𝑒𝑐𝑢𝑛𝑑𝑎𝑟𝑖𝑎


𝑃1 𝑣1 2
𝐸1 = + + 𝑍1
𝜌∗𝑔 2∗𝑔

𝑃1 = 0
𝑣1 ≈ 0
𝑍1 = 0.6𝑚

𝐸1 = 0.6 𝑁 𝑚⁄𝑁

𝑃2 𝑣2 2
𝐸3 = + + 𝑍2
𝜌∗𝑔 2∗𝑔

𝑍3 = 0.25
Reemplazando en la ecuación General de Energía:

𝐻𝐵2 = 𝐸3 + ℎ𝑓 𝑃𝑟𝑖𝑚𝑎𝑟𝑖𝑎 + ℎ𝑓 𝑆𝑒𝑐𝑢𝑛𝑑𝑎𝑟𝑖𝑎 − 𝐸1

Calculamos La potencia consumida:


𝑃𝐶𝑜𝑛𝑠𝑢𝑚𝑖𝑑𝑎 𝐵𝑜𝑚𝑏𝑎 2 = 𝐻𝐵2 ∗ 𝜌 ∗ 𝑔 ∗ 𝑄

Calculo de la potencia del motor


𝑃𝑚𝑜𝑡𝑜𝑟 = 𝑉 ∗ 𝐼𝑝𝑟𝑜𝑚

Calculo de la eficiencia
𝑃𝐶𝑜𝑛𝑠𝑢𝑚𝑖𝑑𝑎
𝑛=
𝑃𝑚𝑜𝑡𝑜𝑟

t vol(m3) Q Velocidad Re f hfp hfs hf total


s m3 (m3/s) (m/s) m m m
49.84 0.05 0.00100321 1.80525186 51104.3977 0.03314897 0.36638547 1.78394261 2.15032808
58.47 0.05 0.00085514 1.53880199 43561.5389 0.03341289 0.26833182 1.29619624 1.56452807
71.37 0.05 0.00070057 1.26066628 35687.8686 0.03379771 0.18217139 0.86997256 1.05214394
85.95 0.05 0.00058173 1.04681504 29634.0103 0.03421969 0.127177 0.59985348 0.72703048

Presion Presion E1 E2 Hb2 Pconsumida Pmotor eficiencia


Psi (Pa) m m m W W
30 206842.8 0.6 21.5432499 23.093578 226.820731 1160.25 19.55%
35 241316.6 0.6 25.0190271 25.9835552 217.53795 1138.15 19.11%
40 275790.4 0.6 28.5005327 28.9526767 198.583233 1127.1 17.62%
45 310264.2 0.6 31.9965732 32.1236036 182.956537 1105 16.56%
EFICIENCIA VS Q
20.00%

19.50%

19.00%
EFICIENCIA (%)

18.50%

18.00%
bomba autocebante
17.50%

17.00%

16.50%

16.00%
0 0.0002 0.0004 0.0006 0.0008 0.001 0.0012
Q (m3/s)