Two Way Slab

fc' = 27.6 S= 5.49 Wd = 4.86


fy = 414 L= 7.32 Wl = 6.46
ρmin = 0.00338164 col = 0.406 Wu = 16.168
ρmin = 0.00317245
use ρmin= 0.00338164

Beam
Flange Member
hf = 178 hm = 330
bf = 965 bw = 305
Af= 171770 Am= 100650 ybar= 325.15556861
yf = 419 ym= 165
Ayf= 71971630 Aym= 16607250
If= 453530057 Im= 913398750
df= 93.8444314 dm= 160.155569
Adf2 = 1512740137 Adm2 = 2581652990

Ib= 5461321934 Is(n-s) = 3440248720


ls(e-w) = 2580186540

Stiffness Ratio
δ(n-s) = 1.58747881 hmin = 148.7847
δ(e-w)= 2.11663841 hmin = 117.2546
1.85205861
I. N - S Direction
Column Strip (Negative Moment) Column Strip (Positive Moment)
L2/4 0.5 1 2 L2/4 0.5 1
δ (L2/L1) = 0 75 75 75 δ (L2/L1) = 0 60 60
δ (L2/L1) > 1 90 75 45 δ (L2/L1) > 1 90 75

L2/L1 = 1.33333333 L2/L1 = 1.3333333333


δ (L2/L1) = 2.11663841 > 1.0 δ (L2/L1) = 2.8221845457 > 1.0

N%= 65 N%= 65

I. E - W Direction
Column Strip (Negative Moment) Column Strip (Positive Moment)
L2/4 0.5 1 2 L2/4 0.5 1
δ (L2/L1) = 0 60 60 60 δ (L2/L1) = 0 60 60
δ (L2/L1) > 1 90 75 45 δ (L2/L1) > 1 90 75

L2/L1 = 0.75 L2/L1 = 0.75


δ (L2/L1) = 1.58747881 > 1.0 δ (L2/L1) = 1.587478807 > 1.0

N%= 82.5 N%= 82.5

I. N - S Direction
A. Negative Factored Moment B. Positive Factired Moment

-Mu= 382.374109 +Mu = 382.37410929


Factored Mu = 248.543171 Factored Mu = 133.83093825

Column Strip Column Strip


-Mu = 161.553061 +Mu = 86.990109863
Beam = 137.3201 Beam = 73.94159
Slab = 24.23296 Slab = 13.04852

Middle Strip Middle Strip


-Mu = 86.9901099 +Mu = 46.840828388

II. E- W Direction
A. Negative Factored Moment B. Positive Factored Moment

-Mu = 530.392542 +Mu = 530.3925416


Factored Mu = 344.755152 Factored Mu = 185.63738956

Column Strip Column Strip


-Mu = 284.423 +Mu = 153.15084639
Beam = 184.875 Beam = 99.54805
Slab = 99.54805 Slab = 53.6028

Middle Strip
-Mu = 60.3321516 +Mu= 32.486543173