Anda di halaman 1dari 33

Why Vaillant?

Because the ecoTEC


delivers day in, day out

Vaillant ecoTEC boiler range

The TECHNICAL Brochure


The TECHNICAL Brochure

Contents
The ecoTEC range 4
The vSMART control 5
Combi boilers 6
System boilers 18
Open vent boilers 24
Flue solutions 30
Schematics and wiring diagrams 34
uniSTOR unvented cylinders 46
Weather compensating controls 50
timeSWITCH controls 52
Room thermostats 53
Controls compatibility finder 54
Vaillant Advance 55
Service 56
Vaillant training 58
Order numbers 60
Notes 62

2 3
The TECHNICAL Brochure

The ecoTEC range The vSmart™ control

The ecoTEC range


The Vaillant ecoTEC range of boilers delivers There’s smart. And then, there’s vSmart™.
first class performance and reliability.
The Vaillant ecoTEC is a remarkable boiler. With Compact dimensions and a range of flueing vSMART™ is a wireless heating and hot water • Controls heating devices in different locations
22 gas boilers ranging from 12-38kW outputs, options mean the ecoTEC boiler is as versatile as ever. control and smartphone app, giving homeowners • Internet weather compensation optimises
available in combination, system or open vent the ability to take control of their heating from system flow temperatures and efficiency, by fully
We’re just as committed to performance too. With
formats, there’s an ecoTEC for virtually every anywhere, at any time. modulating Vaillant boilers
ratings of up to 90% efficiency, the ecoTEC range
home in the UK. We’ve also got a full range of
about as frugal with fuel as you can get, meaning • Easily control traditional S & Y plan systems with
controls and cylinders available, to help you Key features and benefits:
saving energy has never been so easy. VR 66 Wiring Centre
maximise your boiler to its full potential.
• Works with Vaillant’s complete range of eBUS • Self-learning control: vSMART™ learns the
What’s more, with a Quiet Mark Award, from the UK boilers
All our ecoTEC boilers have Vaillant’s key qualities thermal behaviour of the home and knows
Noise Abatement Society, it’s one of the most under-
running through them; fantastic engineering, in- • E-paper high-readability, low energy exactly when to switch on to reach the desired
stated miracles of engineering we’ve ever produced.
credible efficiency, compact and subtle design. We consumption display temperature at the right time.
use only the highest quality components – It’s simpler, smarter, easier, cleaner, leaner, quieter – and • Android and Apple iOS Application. Search
because reliability is as important to us as it just plain better. “Vaillant vSMART” for a demo
4 is to you. 5
The TECHNICAL Brochure

Combi boilers ecoTEC plus 825, 832, 835, 838 and 938

• Dedicated models available for LPG


Giving a solution for off-gas areas

• Stylish contoured case design with drop


down flap
Making this a boiler that fits with the decor
of any home

• Built-in two-stage frost protection


Ensuring optimal performance all year round

• An innovative solution for large homes


Featuring an innovative integrated hot water
device ‘actoSTOR’ at the back of the boiler (938
only)

• Extended guarantees available when installed


by a Vaillant Advance partner
For total peace of mind

• Total system solution available from one


Key features and benefits: manufacturer
Intelligent controls and accessories

Combi boilers
all available (see pages 54 - 61)
High efficiency combination boilers are an increasingly popular • Highly efficient and economical to run
With up to an 89.3% efficiency rating (SAP 2009)
choice in UK homes and now account for well over half of all new ErP rated A • Quiet Mark accreditation
Thanks to being ultra quiet whilst in operation
domestic boilers installed in UK every year.
• Instant hot water delivery in just 5 seconds*
ecoTEC condensing combi boilers do not require The ecoTEC plus 938 is a 38kW high efficiency Meaning no need for a storage tank or cylinder • Step by step full text Installation Wizard
hot water cylinders or cold water storage tanks, storage combination boiler, which has been designed For quicker, “first time right” set up and
minimising the space they occupy. especially for larger homes that have a higher hot installation
• Flame lift detection system
water demand. Featuring an innovative integrated Enabling more efficient and quieter combustion
Vaillant’s range of combi boilers is broad enough to • Compatible with aroTHERM air to water heat
hot water device at the back of the boiler called the
ensure the ideal solution for all house types — from pump hybrid system
‘actoSTOR’. This separate 15 litre ‘actoSTOR’ unit
a one-bedroom/bathroom flat through to a four- Making the perfect entry into renewable systems
provides exceptional hot water delivery which re-
bedroom property with two bathrooms.
charges in just 2 minutes. All of this without the need Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential:
The ecoTEC plus high efficiency combi boiler for you to install a separate hot water cylinder.
range uses premium components for outstanding
performance, quality, reliability and efficiency, Heating controls: Room thermostats:
the very best in home heating. The ecoTEC timeSWITCH 150 VR 81
combination range is available in a wide range of timeSWITCH 160 VRT 50
outputs from 25kW to 38kW. VRT 15

VRC 470f (wireless version)

Renewable solution:
VRT 350
aroTHERM air to water
VRT 350f (wireless version) heat pump hybrid system

*Dependent on the distance of the boiler from taps

6 **Compatible with ecoTEC pro 24, pro 28, pro 28 LPG, pro 30, ecoTEC plus 825, ecoTEC plus 832, ecoTEC plus 832 LPG, ecoTEC plus 835 and ecoTEC plus 838 only 7
The TECHNICAL Brochure

ecoTEC exclusive 832 and 838 ecoTEC pro 24, 28 and 30

• Compact dimensions • Removable side panels and push-fit flue system


(800mm x 480mm x 450mm) For improved accessibility, ease of installation and
For excellent siting, flexibility and ease greater installation flexibility
of installation
• Quiet Mark accredited
Thanks to being ultra quiet whilst in operation
• Installed filling loop
For even quicker installation
• Fully modulating low NOx burner and fan
For improved energy efficiency
• Push fit flue system
For greater installation flexibility
• Built-in two-stage frost protection
To ensure optimal performance all year round
• Wide modulation range
For maintaining higher efficiencies at lower outputs • Increased speed of hot water delivery
Thanks to Vaillant’s ‘aquaCOMFORT’ warm
• Blue backlit scrolling text display start feature
Meaning clear visibility even in poor light conditions
• Extended guarantees available when installed by a
Vaillant Advance partner
• Extended guarantees available when installed by a
For added piece of mind
Vaillant Advance partner
The ecoTEC exclusive range of high efficiency For total peace of mind The ecoTEC pro range of combi boilers combine
• Total system solution available from one

Combi boilers
combi boilers offers premium performance and fuel the built-in quality, reliability and performance
efficiency whilst creating a solid basis for the heating you’d expect from Vaillant, with a simple design manufacturer
• Total system solution available from one Intelligent controls and accessories all available (see
system of larger homes. manufacturer and approach.
pages 54 - 61)
The range features 32kW and 38kW models, which Intelligent controls and accessories all available (see The range features 24, 28 and 30kW models, making
pages 54 - 61) this boiler perfect for homes with a smaller heating
can deliver much higher than average central • Dedicated models available for LPG
heating outputs, making the ecoTEC exclusive a must and hot water requirements. Giving a solution for off-gas areas
• Quiet Mark accredited
have for larger properties. Key features and benefits:
Thanks to being ultra quiet whilst in operation
Key features and benefits: • Highly efficient and economical to run • Wide modulation range of up to 1:4
With up to an 89.3% efficiency rating (SAP 2009) Ensuring low energy consumption and
• Highly efficient and economical to run
• Compatible with aroTHERM air to water heat pump ErP rated A maximum efficiency
ErP rated A hybrid system
Making the perfect entry into renewable systems • Compact dimensions • Compatible with aroTHERM air to water heat pump
• Features electronically controlled low (720mm x 440mm x 338mm) hybrid system
energy pump For flexible siting options Making the perfect entry into renewable systems
Helping to reduce energy consumption
Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential: Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential:

Heating controls: Room thermostats: Heating controls: Room thermostats:


timeSWITCH 150 VR 81 timeSWITCH 150 VR 81
VRT 50 timeSWITCH 160 VRT 50
timeSWITCH 160
VRT 15 VRT 15
VRC 470f (wireless version) VRC 470f (wireless version)

Renewable solution: VRT 350 Renewable solution:


VRT 350
aroTHERM air to water VRT 350f (wireless version) aroTHERM air to water
VRT 350f (wireless version)
heat pump hybrid system heat pump hybrid system
8 9
*Compatible with ecoTEC pro 24, pro 28, pro 28 LPG, pro 30, ecoTEC plus 825, ecoTEC plus 832, ecoTEC plus 832 LPG, ecoTEC plus 835 and ecoTEC plus 838 only *Compatible with ecoTEC pro 24, pro 28, pro 28 LPG, pro 30, ecoTEC plus 825, ecoTEC plus 832, ecoTEC plus 832 LPG, ecoTEC plus 835 and ecoTEC plus 838 only
The TECHNICAL Brochure

ecoTEC combination boiler dimensions and key components ecoTEC combination boiler dimensions and key components

Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 Combination boilers - ecoTEC exclusive 832 / 838
ecoTEC pro 24 / 28 / 30
Dimensions plus/pro: ecoTEC plus shown Dimensions:
14
5
6
1
7 13
4 8 2

9 3
3
10
11
2
12
1 4
13
12
14
5
11 6
15
7

19 10
8

18

Combi boilers
17 16
9

Boiler model Dimension B Key:


ecoTEC pro 24/28/30 338mm
Clearances: Key:
1. Gas valve
ecoTEC plus 825/832 338mm 2. Water pressure sensor 1 Expansion vessel
ecoTEC plus 835 372mm 150mm, 60/100 flue
3. Venturi with mass flow sensor (plus only) 165mm, 60/100 flue (438 only) 2 Air intake pipe
ecoTEC plus 838 406mm
4. Heat exchanger 246mm, 80/125 flue (438 only)
ecoTEC plus 938 600mm 3 Burner assembly
5. Connection for the air/ flue 4 Ignition electrode
gas duct
Clearances: 6. Expansion vessel 5 Gas Valve

7. Air intake pipe 6 Diverter valve


8. Compact thermal module 7 Hot water heat exchanger
9. Ignition electrode 8 Aqua-Sensor
10. Fan 9 Electronics box
11. Automatic air vent
10 Pump
12. Pressure gauge
11 Auto air vent
13. Internal pump 150mm
180mm (438 only) 12 Pressure sensor
14. Bypass valve
15. Expansion relief valve 13 Heat exchanger
16. Electronics box 14 Air / flue gas duct
17. Diverter valve with bypass
18. Impeller sensor (hot water)
19. Secondary heat exchanger

10 11
The TECHNICAL Brochure

ecoTEC combination technical specifications ecoTEC combination technical specifications

Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 / 938 Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 / 938

ecoTEC plus ecoTEC plus

Technical data Unit 825 832 835 838 938 Technical data Unit 825 832 835 838 938

0010018354 0010018354
Article number 0010018353 0010016540 0010018356 0010018357 Article number 0010018353 0010016540 0010018356 0010018357
0010018355 (LPG) 0010018355 (LPG)

Gas inlet connection mm 15 22 22 Maximum CH input kW 19.6 24.7 31 28.9

Connections heating flow 5.5


mm 22 Minimum CH output kW 4 6.2 6.8
and return 6.4 (LPG)

Connector expansion relief Maximum flow


mm 15
o
C 85
valve (min.) temperature
Adjustable flow
Flue sizes (concentric) mm 60/100 temperature (default o
C 30 - 80
setting: 75oC)
Condensate drain (min.
mm 19 Maximum CH system
internal diameter drain) bar 3
pressure
Inlet gas working pressure Mains water pressure
mbar 20
(G20, natural gas) required for maximum bar 0.80
G31 propane gas flow flow rate
mbar 37
pressure Expansion vessel
litre 10
capacity
Gas flow rate at 15 C
o

Combi boilers
and 1013 mbar (based on Volume of water
m3h 2.7 3.4 3.8 4.2 l/h 830 1,049 1,307 1,230
hot water generation, if circulating (ΔT = 20k)
applicable), G20 Approx. Condensation
volume at 50°C l/h 2.0 2.5 3.1 2.9
Gas flow rate at 15oC
feed/30°C return
and 1013 mbar (based on
kg/h 2.0 2.5 2.8 3.1
hot water generation, if Remaining feed head
applicable), G31 of pump (at nominal
bar 0.25
circulation water
Approved flue type C13, C33, C43, C53 volume)
Minimum DHW flow
NOx class 5 l/min 2
rate
SEDBUK SAP seasonal DHW flow rate at 35°C
% 89.3 l/min 10.5 13 14.3 15.9
efficiency 2009 temperature rise
Maximum domestic
ErP rating Central Heating A bar 10
cold water pressure
ErP rating Hot Water A Minimum operational
bar 0.35
water pressure
Boiler dimensions (WxHxD) mm 440x720x338 440x720x372 440x720x406 440x720x600 Hot water discharge o
C 35 - 65
temperature range
Weight (boiler only) kg 36 37 38 43 60 Electricity supply
V-/Hz 230/50
voltage
Nominal heat output range
5.7 - 25.7 Internal fuse (slow)
of CH at 50oC flow/30oC kW 4.2 - 20.4 6.4 - 32.2 7.1 - 30.1 A 2
6.7 - 25.7 (LPG) main voltage
return
Nominal heat output range Minimum electrical
5.2 - 24.4 W 35 45 55
of CH at 80oC flow/60oC kW 3.8 - 19.3 5.8 - 30.4 6.4 - 28.6 power consumption
6.0 - 24.4 (LPG)
return
Maximum electrical
W 65 85 90 120 140
Maximum DHW output kW 25.4 31.8 35 38.7 power consumption
Standby electrical
Maximum DHW input kW 25.9 32.4 35.7 39.5 W <2 <3
power consumption
Protection class IP X 4D

12 13
The TECHNICAL Brochure

ecoTEC combination technical specifications ecoTEC combination technical specifications

Combination boilers - ecoTEC pro 24 / 28 / 30 Combination boilers - ecoTEC pro 24 / 28 / 30

ecoTEC pro ecoTEC pro

Technical data Unit 24 28 30 Technical data Unit 24 28 30

0010018495 0010018495
Article number 0010018494 0010016538 Article number 0010018494 0010016538
0010018496 (LPG) 0010018496 (LPG)

Gas inlet connection mm 15 Maximum DHW input kW 23.7 27.8 30.6


19.1
Connections heating flow and Maximum central heating input kW 19.1 25
mm 22 18.8 (LPG)
return
5.5
Minimum central heating output kW 5.5 8.5
Connector expansion relief valve 7.7 (LPG)
mm 15
(minimum) Maximum flow temperature °C 85
Flue size (concentric) mm 60/100 Adjustable flow temperature
°C 30 - 80
(default setting: 75°C)
Condensate drain (minimum
mm 19
internal diameter drain) Maximum CH system pressure bar 3

Inlet gas working pressure (G20, Mains water pressure required for
mbar 20 bar 0.8
natural gas) maximum flow rate

Inlet gas working pressure (G31, Expansion vessel capacity litre 8


mbar 37
propane) Volume of water circulating (ΔT=

Combi boilers
l/h 813 1,049
20 K)
Gas flow rate at 15°C and 1013
mbar (based on hot water m3/h 2.5 2.9 3.2 Approx. Condensation volume at
l/h 1.9 2.5
generation, if applicable), G20 50°C feed/30°C return
Remaining feed head of
Gas flow rate at 15 °C and 1013 pump (at nominal circulation bar 0.25
mbar (based on hot water kg/h 1.9 2.2 2.4 water volume)
generation, if applicable), G31
Minimum DHW flow rate l/min 2
Approved flue type C13, C33, C43, C53
DHW flow rate at 35°C
l/min 9.6 11.1 12.3
NOx class 5 temperature rise

Max. domestic cold water pressure bar 10


SEDBUK SAP seasonal efficiency
% 89.3
2009 Min. operational water pressure bar 0.35

ErP rating Central Heating A Hot water discharge temperature


°C 35 - 65
range
ErP rating Hot Water A
Electrical supply voltage V-/ Hz 230/50
Boiler dimensions (WxHxD) mm 440x720x338
Internal fuse (slow) main voltage A 2

Weight (boiler only) kg 38 39 Minimum electrical power


W 35
consumption
Nominal heat output
5.7-19.9 Maximum electrical power
range of central heating at 50°C kW 5.7 -19.9 6.9-25.7 W 50 80
6.9-25.7 (LPG) consumption
flow/30°C return
Standby electrical power
Nominal heat output W <2
consumption
range of central heating at 80°C kW 5.2 - 18.9 8.0 - 24.7
flow/60°C return
Protection class IP X 4D

Maximum DHW output kW 23.4 27.2 30

14 15
ecoTEC combination technical specifications ecoTEC combination technical specifications

Combination boilers - ecoTEC exclusive 832 / 838 Combination boilers - ecoTEC exclusive 832 / 838

ecoTEC exclusive ecoTEC exclusive

Technical data Unit 832 838 Technical data Unit 832 838

Article number 0010002668 0010002669 Article number 0010002668 0010002669

Gas inlet connection mm 15 Expansion vessel capacity litre 10

Connections heating flow and return mm 22 Volume of water circulating (ΔT= 20 K) l/h 1,161 1,290
Connector expansion relief valve (minimum) mm 15 Approx. Condensation volume at 50°C feed/30°C
l/h 2.8 3.1
return
Flue size (concentric) mm 60/100
Remaining feed head of pump (at nominal
Condensate drain (minimum internal diameter drain) mm 10.7 14.4 bar 0.25
circulation water volume)
Inlet gas working pressure (G20, natural gas) mbar 20
Minimum DHW flow rate l/min 1.5
Inlet gas working pressure (G31, propane) mbar 37
DHW flow rate at 35°C temperature rise l/min 12.9 15.2
Gas flow rate at 15°C and 1013 mbar (based on
m3/h 3.4 4
hot water generation, if applicable), G20
Maximum domestic cold water pressure bar 10
Gas flow rate at 15 °C and 1013 mbar (based on hot water
kg/h 2.49 2.95 Minimum operational water pressure bar 0.35
generation, if applicable), G31

Combi boilers
Hot water discharge temperature range °C 35 - 65
Approved flue type C13, C33, C43, C53
Electrical supply voltage V-/ Hz 230/50
NOx class 5
Internal fuse (slow) main voltage A 2
SEDBUK SAP seasonal efficiency 2009 % 89.8 89.9

ErP rating Central Heating A Minimum electrical power consumption W 40

ErP rating Hot Water A Maximum electrical power consumption W 95 110


Boiler dimensions (WxHxD) mm 480x800x450
Standby electrical power consumption W 5
Weight (boiler only) kg 44 46
Protection class IP X 4D
Nominal heat output
kW 10.8 - 28.7 11.9 - 31.8
range of central heating at 50°C flow/30°C return
Nominal heat output
kW 10.2 - 27.0 11.2 - 30.0
range of central heating at 80°C flow/60°C return

Maximum DHW output l/min 31.4 37.2

Maximum DHW input l/min 32 38

Maximum central heating input l/min 27.6 30.6

Minimum central heating output l/min 10.4 11.4

Maximum flow temperature °C 90

Adjustable flow temperature (default setting: 75°C) °C 40 - 85

Maximum CH system pressure bar 3

Mains water pressure required for maximum flow rate bar 0.5

16 17
The TECHNICAL Brochure

System boilers ecoTEC plus 612, 615, 618, 624, 630 and 637

• Highly efficient and economical to run


With up to an 89.4% efficiency rating (SAP 2009)
ErP rated A

• Advanced modulation during periods of


low heat demand
Ensuring low energy consumption and
maximum efficiency

• Flame lift detection system


Enabling more efficient and quieter combustion

• Quiet Mark accredited


Thanks to being ultra quiet whilst in operation

• Stylish contoured case design with drop down flap


Making this a boiler, which fits with the decor of
any home

• Total system solution available from


one manufacturer
Intelligent controls, cylinders and accessories all
available (see pages 54 - 61)

The ecoTEC plus range of system boilers is available • Dedicated models available for LPG
in a wide range of output models including 12kW, Giving a solution for off-gas areas
15kW, 18kW, 24kW, 30kW and 37kW, meaning that
there is a suitable model for almost any home. The • Step by Step, full text installation wizard
stylish design and small dimensions also make it a For quicker, “first time right” set up and installation
perfect fit with any home.
A system boiler provides central heating and hot water via

System boilers
Key features and benefits:
a storage cylinder, which is filled from the mains and often
• Removable side panels
housed in an airing cupboard. For additional accessibility flexibility

This means that there is no need for water tanks


in the loft, as with an open vent boiler. This type Below is a list of related Vaillant accessories, designed to help maximise your system to its full
of system benefits from having an electric potential:
immersion heater within the cylinder.
Heating controls: Cylinders:
System boilers can be used with a hot water
timeSWITCH 160 uniSTOR
storage cylinder as a stand-alone heating system,
or can be used as part of a number of renewable Renewable solutions:
heating systems for example solar thermal. VRC 470f (wireless version) auroTHERM solar systems

VRT 350 aroTHERM air to water heat


VRT 350f (wireless version) pump hybrid systems
Room thermostats:
VRT 15
18 VRT 81 19
The TECHNICAL Brochure
Annotated product diagram Annotated product diagram
Combination boilers System boilers

ecoTEC system dimensions and flue clearances ecoTEC system boiler key components

ecoTEC plus 824 / 831 / 837 ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637
Dimensions: ecoTEC pro 24 / 28

5 5

6 6
150mm, 60/100 flue
7 165mm, 60/100 flue (438 only) 7

4 4 246mm, 80/125 flue (438 only) 8


8

9 9

3 3
10 10
11 11
2 2
12 12
1 1
13 13

14
14

15 15

19

System boilers
150mm
Clearances: 18 180mm (438 only)
16
150mm, 60/100 flue
17 16
165mm, 60/100 flue (438 only)
246mm, 80/125 flue (438 only)

Key:
1. Gas valve 9. Ignition electrode
2. Water pressure sensor 10. Fan
Legend Legend
3. Venturi with mass flow sensor 11. Automatic air vent
1 Gas valve 11 Automatic air vent 1 Gas valve 9 Ignition electrode
Boiler model Dimension B 4. Heat exchanger 12. Pressure gauge
2 Water pressure sensor 12 Pressure gauge 2 Water pressure sensor 10 Fan
5. Connection for the air/ flue gas duct 13. Internal pump
ecoTEC plus
3 Venturi with mass flow 13 Internal
612/615/618/624 pump
338mm 3 vessel
6. Expansion Venturi with mass flow 11 14. Bypass
Automatic air vent
valve
sensor sensor
150mm ecoTEC 14 Bypass
plus 630 valve
372mm 7. Air intake pipe 12 15. Expansion
Pressure gaugerelief valve
180mm (438 only) 4 Heat exchanger ecoTEC 15 Expansion 406mm
plus 637 relief valve 4 thermal
8. Compact Heat module
exchanger 13 16. Electronics
Internal pump box
20 5 Connection for the air/ 16 Electronics box 5 Connection for the air/ 14 Bypass valve 21
flue gas duct flue gas duct
17 Diverter valve with 15 Expansion relief valve
6 Expansion vessel bypass 6 Expansion vessel
16 Electronics box
The TECHNICAL Brochure

ecoTEC system technical specifications ecoTEC system technical specifications

System boilers - ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637 System boilers - ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637

ecoTEC plus ecoTEC plus

Technical data Unit 612 615 618 624 630 637 Technical data Unit 612 615 618 624 630 637

0010018533 0010018536 0010018533 0010018536


Article number 0010018531 0010018532 0010018535 0010018538 Article number 0010018531 0010018532 0010018535 0010018538
0010018534 0010018537 0010018534 0010018537
Maximum central
Gas inlet connection mm 15 22 kW 12.4 15.5 18.6 24.7 30.9 38.1
heating input
Minimum central 4 6.2
Connections heating kW 3.2 5.5 6.8
mm 22 heating output 5.3 (LPG) 9.0 (LPG)
flow and return
Maximum flow
°C 85
Connector expansion temperature
mm 15
relief valve (minimum)
Adjustable flow
temperature (default °C 30 - 80
Flue size (concentric) mm 60/100
setting: 75°C)
Condensate drain Maximum CH system
bar 3
(minimum internal mm 19 pressure
diameter drain) Mains water pressure
required for maximum bar 0.8
Inlet gas working
flow rate
pressure (G20, natural mbar 20
gas) Expansion vessel
litre 10
capacity
Inlet gas working
pressure (G31, mbar - 37 Volume of water
l/h 525 662 796 1,049 1,307 1,617
propane) circulating (ΔT= 20 K)

Gas flow rate at 15°C Approx. Condensation


and 1013 mbar volume at 50°C l/h 1.2 1.6 1.9 2.5 3.1 3.8
(based on hot water m3/h 1.3 1.6 2 2.6 3.7 4.1 feed/30°C return
generation, if Remaining feed head
applicable), G20 of pump (at nominal
bar 0.25
Gas flow rate at 15 °C circulation water
and 1013 mbar volume)
(based on hot water kg/h - - 1.5 1.9 2.4 3
Electrical supply
generation, if V-/ Hz 230/50
voltage
applicable), G31
Internal fuse (slow)
Approved flue type C13, C33, C43, C53 A 2

System boilers
main voltage
NOx class 5
Minimum electrical
W 35 45 55
SEDBUK SAP seasonal power consumption
% 89.0 89.1 89.3 89.4 89.2
efficiency 2009
Maximum electrical
W 50 55 65 70 80 115
ErP rating A power consumption

Boiler dimensions Standby electrical


mm 440x720x338 440x720x372 440x720x406 W <2 <3
(WxHxD) power consumption

Weight (boiler only) kg 36 37 38 43 Protection class IP X 4D


Nominal heat output
6.4 -32.2
range of central 4.2 - 19.3
kW 3.3 - 12.9 3.3 - 16.1 5.7 - 25.7 5.5 - 19.3 7.1 - 39.6
heating at 50°C 9.4 - 32.1 (LPG)
(LPG)
flow/30°C return
Nominal heat output
3.8 - 18.5 5.8 - 30.4
range of central
kW 3.0 - 12.2 3.0 - 15.4 5.0 - 18.5 5.2 - 24.4 8.5 - 6.4 - 37.6
heating at 80°C
(LPG) 30.4(LPG)
flow/60°C return

Maximum DHW output kW 12.2 15.4 18.5 24.4 30.4 37.6

Maximum DHW input kW 12.4 15.7 18.9 24.9 31 38.4

22 23
The TECHNICAL Brochure

Open vent boilers ecoTEC plus 412, 415, 418, 424, 430 and 438

Key features and benefits:


• Highly efficient and economical to run
With up to an 89.2% efficiency rating (SAP 2009) ErP
rated A

• Compact and light weight


(375 x 600 x 316 on most models)
Ideal kitchen friendly design

• Push button programming


Makes usage straightforward and easy to use

• Built-in two-stage frost protection


To ensure optimal performance all year round

• Push fit flue system


For greater installation flexibility

• Total system solution available from


one manufacturer
Intelligent controls, cylinders and accessories
all available (see pages 54 - 61)
Extremely reliable and displaying all the in-built
quality you’ve come to expect from Vaillant, the
ecoTEC plus is clearly one of the best open vent • Wide modulation range of up to 1:6
Ensuring low energy consumption and
solutions available today. Where homes utilise a
maximum efficiency
traditional open-vented system to provide their
heating and hot water, the ecoTEC plus open vent
• Quiet Mark accredited
boiler is the ideal way to deliver exceptional,
Thanks to being ultra quiet whilst in operation
energy efficient performance.
An open vented boiler works alongside a separate
Available in six different output models, 12, 15, 18, 24,
hot-water cylinder and a tank to store the 30 and 38kW – ecoTEC plus open vent boilers are
cold water. the most compact boilers ever developed by Vaillant.
This kitchen-friendly design, along with excellent
Like a sealed system, an open vented boiler is siting versatility and low lift weight, ensure a quick
normally suited to a larger home with a higher and straightforward installation.
hot water requirement.

For homes that already use a traditional open

Open vent boilers


vented system (with a storage cylinder and cold
water tank), this extremely compact, highly Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential:
versatile and kitchen-friendly boiler is the perfect
upgrade. Heating controls: Room thermostats:
timeSWITCH 160 VRT 15
VRT 81
VRC 470f (wireless version) Cylinder:
VRT 350 uniSTOR
VRT 350f (wireless version)
24 25

* Please note, images used within this brochure are for illustrative purposes only.
The TECHNICAL Brochure

ecoTEC open vent dimensions ecoTEC open vent boiler key components

Dimensions:

412, 415, 418, 424, 430

5
Clearances:

150mm, 60/100 flue


165mm, 60/100 flue (438 only) 6
246mm, 80/125 flue (438 only)

2
7

Open vent boilers


3 Key:
1. Flue pipe connection
2. Fan
Boiler model Dimension B 3. Gas valve
4

ecoTEC plus 4. Electronics box


316mm
412/415/418/424/430 5. Burner module
150mm 6. Ignition electrode
180mm (438 only) ecoTEC plus 438 340mm
7. Condensate Siphon
26 438 only 27
The TECHNICAL Brochure

ecoTEC open vent technical specifications ecoTEC open vent technical specifications

Open vent boilers - ecoTEC plus 412 / 415 / 418 / 424 / 430 / 438 Open vent boilers - ecoTEC plus 412 / 415 / 418 / 424 / 430 / 438
ecoTEC plus
ecoTEC plus
Technical data Unit 412 415 418 424 430 438
Technical data Unit 412 415 418 424 430 438
Article number 0010015669 0010015670 0010015671 0010015672 0010015673 0010002725
Heat exchanger type Article number 0010015669 0010015670 0010015671 0010015672 0010015673 0010002725
Aluminium Stainless Steel
(material)
Maximum working pressure
bar 0.3/3
Gas inlet connection mm 15 (pms)
Approx. Condensation
Connections heating flow volume at 50°C feed/30°C l/h 1.23 1.53 1.84 2.47 3.06 3.1
mm 22
and return return
Connector expansion relief
mm 15 Electrical supply voltage V-/ Hz 230/50
valve (minimum)

Flue size (concentric) mm 60/100 boiler connection (80/125 available with adaptor) External fuse (slow) main
A 3
voltage
Condensate drain (external 19 (int Standby electrical power
mm 21.5 W 2 <5
diameter) diameter) consumption
Inlet gas working pressure
mbar 20 Protection class IP X 4D
(G20, natural gas)
Maximum gas flow rate at
15°C and 1013 mbar (based
m3/h 1.9 2.7 3.2 3.8 4.06
on hot water generation, if
applicable), G20

Minimum gas flow rate at


15°C and 1013 mbar (based
m3/h 0.48 0.53 0.65 0.76 0.71
on hot water generation, if
applicable), G31

Approved flue type C13, C33, C43, C53

NOx class 5

ErP rating Central Heating A A A A A A

Boiler dimensions (WxHxD) mm 375x600x316 375x600x340

Weight (boiler only) kg 23.5 23.8 33

Nominal heat output


range of central heating at kW 4.7 - 12.8 4.7 - 15.9 5.2 - 19.1 6.3 - 25.7 7.5 - 31.8 6.8 - 41.0
50°C flow/30°C return

Nominal heat output


range of central heating at kW 4.5 - 12.3 4.5 - 15.2 5.0 - 18.3 6.1 - 24.6 7.2 - 30.5 6.3 - 38.0
80°C flow/60°C return
Maximum central heating
kW 12.3 15.3 18.4 24.7 30.6 38.4
input

Open vent boilers


Minimum central heating
kW 5.0 4.5 5.0 6.1 7.2 6.3
output

Maximum flow temperature °C 75

Adjustable flow
temperature (default °C 10 - 83 10 - 80 15 - 80
setting: 75°C)

28 29
ecoTEC domestic boiler flue tech summary ecoTEC domestic boiler flue tech summary

Permissible flue lengths


G
Maximum ecoTEC plus ecoTEC ecoTEC
ecoTEC pro combi C
flue lengths* combi plus system plus open vent N
J V
M
J
Boiler model 825 832 835 838 938 612/615 618 624 630 637 412/415/418/424/430/438 24 28 30 B
U Q
A
Standard horizontal
12m 5.5m 5.5m 5.5m 5.5m 22m 12m 5.5m 5.5m 5.5m 10m 12m 12m 12m E G H
100mm diameter
J S T
K R
Standard vertical F L
100mm diameter
16m 8m 8m 8m 8m 26m 16m 8m 8m 8m 10m 16m 16m 16m
D J J L L P S
S S
Optional horizontal
39m 32m 32m 32m 32m 25m 39m 32m 32m 32m 25m 39m 39m 39m
125mm diameter

Optional vertical 25m


41m 34m 34m 34m 34m 27m 41m 34m 34m 34m 41m 41m 41m
125mm diameter 27m (438 only) A 300mm adjacent to a boundary. The dimension below eaves, balconies and car ports
can be reduced to 25mm, as long as the flue terminal
The dimension below eaves, balconies and car ports R
is extended to clear any overhang. External flue joints
can be reduced to 25mm, as long as the flue terminal
B must be sealed with suitable silicon sealant.
is extended to clear any overhang. External flue joints
must be sealed with a suitable silicon sealant. 300mm above adjacent ground or balcony
S
or storm porch
1500mm between a vertical flue terminal and a window
C 600mm distance to a surface facing a terminal, unless
or dormer window.
it will cause a nuisance. BS 5440: Part 1 recommends
D 1200mm between terminals facing each other. T
that care is taken when siting terminals in relation to
Vertical flue clearance, 300mm adjacent to a surfaces facing a terminal.
E
boundary line.
U 300mm clearance alongside another terminal.
600mm distance to a boundary line, unless it will
V 300mm above roof level.
cause a nuisance. BS 5440: Part 1 recommends that
F
care is taken when siting terminal in relation to
boundary lines.
• All measurements are the minimum
300mm minimum clearance from a skylight to a
G
vertical flue or to another vertical flue.
clearances required.
Vertical flue clearance, 500mm to non-combustible • Terminals must be positioned so to avoid
H building material, and 1500mm clearance to combustion products entering the building.
combustible building material.
• Support the flue at approximately one metre
300mm above, below and either side of an opening
J
door, air vent or opening window.
intervals and at a change of direction, use suitable
600mm diagonally to an opening door, air vent or
brackets and fixings.
K
opening window. • Installations in car ports are not recommended.
L 300mm to an internal or external corner. • A flue outlet should be protected with a guard if
2000mm below a Velux window, 600mm above or to persons could come into contact with it or if it
M
either side of the Velux window. could be damaged.
400mm from a pitched roof or 500mm in regions with • The flue cannot be lower than 1 metre from the top
N

Flue solutions
heavy snowfall.
of a light well due to the build up of combustion
P 25mm from vertical drain pipes and soil pipes.
products.
200mm below eaves and 75mm below gutters,
Q
pipe and drains.
• Dimensions from a flue terminal to a fanned
air inlet to be determined by the ventilation
equipment manufacturer.

30 31
Vertical flue options Notes:
3 4 5
The overall maximum
The overall
Notes:
not be maximum
flue length
exceeded flue length
must 3 4 5
The overall maximum flue length must not beThe overall maximum flue length
exceeded
Notes: must notmust
be exceeded
Notes: must not be exceeded
2 Horizontal sections have a continuous fall of
The overall maximum flue length Horizontal
must notThe overall maximum flue length
be exceeded
at least 2.5°sections must have
(44mm/metre) a continuous
back fall of
to the boiler
The TECHNICAL Brochure must not be exceeded Horizontal sections must have a continuous fallatofleast 2.5°Horizontal sections
(44mm/metre) must
back have
to the a continuous fall of
boiler

Flue solutions
Vertical flue options 6 at least 2.5° (44mm/metre) back to the boiler at least 2.5° (44mm/metre) back to the boiler
8 9 10 1 Vertical flue options 7 13 3 4 5
1
1
8 9 10 1
Vertical flue options8 9 10
Vertical flue options 7 13 1 7 13 3 4 5
3
3 7 138 9 10 7 13 2 6 Notes: 6
7 13 7 13 7 13 7 13
3
3
7 13 The overall maximum flue length
Flue solutions 4 5 6
4 5 6 4 5 6
4 5 6
1
1
7 13 7 13 must not be exceeded

7 3 4 5 Horizontal sections must have a continuous fall of


3 4 5 6
3 7 at least 2.5° (44mm/metre) back to the boiler
4 5 6 3 4 5
4 5 6 3 4 5 3 4 5 3 4 5
Horizontal flue configurations 4 5 6
3 4 5
13 options
Vertical77 flue
13 3 4 5 Vertical
3 4 5 flue configurations
7 13 3 4 5 23 4 5 7 13
Notes: Notes: 7 13 9 10 11 7 13 7 13 7 13
1 Notes: flue length
The overall maximumThe overall maximum flue length 7 13 3 42 5 2 7 137 13 3 4 5 7 13
1 must not be The
exceeded
overall
mustmaximum flue length
not be exceeded
6
9 10 11 2 must not be exceeded
2 3 4 5
2 4 6 6 6 12
8 9 10 8 9 10 1 1 6 12 1 3 4 5
1 1 1 3 4 5 3 4 5 3 4 5 2 6 6
1
8 9 10 1 4 8 9 10 8 9 10 6 3 4 5 6 12 1 1 3 4 5 3 4 5
3 3 4 5
3
3 8 9 10
Notes: 3 4 5 2 6 3 42 5 6 33 44 55 6 6 3 4 5
3 The overall maximum flue length 7 3 43 54 5 1 33 44 55 3 4 5
4 5 6
3 5 6 7 8
must not be exceeded 3 4 5 72 13 6 2 6
4 5 6 5 6 7 8 3
72 13
4 5 6 Notes: 1 1 8 9 10
4 5 6
6 overall maximum flue length 5 6 7 8
4 5 6 4 5 6 8 9 10 7 13
4 5 6
1
4 5 The 1
2 2
8 9 10 1 3 1 must not be exceeded
3
7 7 6 3 4 5
1
8 9 10 3 3 4 5 6 4 5 6 17 1
6 3 4 5
8 9 10 3 3 4 5 64 1 8 9 10 1
6 3 43 54 5
8 9 10 1
4 5 6
7 4 5 6
4 5 66
4 5 6
3 4 5 1 3 4 5
4 5 67
3 4 5 22 6 3 4 5 1 6 2 3 4 5
85 9610 7 8 3 6 3 4 5 6 1 3 4 5
3 4 5 6 3 4 5 2 16 6
Notes: 4 5 6 1 2 6 6 1 7 11
The overall maximum flue length 3
3 4 5 3 4 5
4 5 6 must not be exceeded 7 3
4 5 6
3 1 4 5 6 3
2 3 4 5 1 3 4 5
4 5 6 6 6
1 3
4 5 6
7
4 5 6 Vertical flue accessories 2 6
4 5 6
8 9 10 6
3 9 10 11 Part Number
4 5 6
Component Description 3 4 5 Part Number 2
3
Ø60/100 Ø80/125 1 3 4 5
8 9 10 8 9 10 1 2 6 6
4 5 6 4 5 64 5 6 1 8 9 10
8
1 41 5 6 5 6 7 8
1 Bends 45° (pack of 2) 303911 303211
31
1 1 1 5 64 7 8
8 9 10 3 7 1 1
8 9 10 43 5 6 1 1 3 5
8 9 10 3 4 2 Elbow 87° 303910 303210
94 105 611 7 7
1 4 5 6
1 4 5 6 3 5
4 5 6 3 Air/flue duct extension (470mm) 303902 303202
7 1 7 11
1
1 8 9 10 4 Air/flue duct extension (970mm) 3039031 303203
4 5 6 1 7 7 11 11 12
1 5 Air/flue duct extension (1970mm) 303905 303205
3 3 1 The overall maximum flue
9 length must not be exceeded
4 5 6 8 9 10 3
2 12 8 9 10 1 3 4 Vertical
6 flue accessories
Vertical air/flue duct and terminal 0020065937 303200 7 3, 4, 5 11
4 5 6 4 5 6 6 sections must have a continuous fall of
Horizontal
1
1
7 4 5 6
1
6
6 4 5 6
Vertical 7flueVertical
7
flue accessories
accessories 7 Flexible Roof Seal 303980 303980
Vertical flue accessories
Part Number Part Number at least 2.5° (44mm/metre) back to the boiler
3
Component
8 Flat roofDescription
penetration collar 009056 009056 2
4 5 6 Vertical flue accessories Part Number Part
PartNumber
Number Part Number Ø60/100 Ø80/125
7 Component 9 Sliding Sleeve 303915 2 303215
Component Description Description 2 1 8
5 6 7 8 Ø60/100 Ø60/100
Ø80/125 Ø80/125 7 11
3 10Part Number Adjustable Part
flueNumber
support (pack of 3) 303935 1
303616 7 11
Component Description Bends 45° (pack 2 303911 8 8
8 9 10
4 5 6
1
Ø60/100 Ø80/125 1 of 2) 7
303211 1
11 7 11
Horizontal flue accessories 11 Telescopic air/flue duct extension 303906 - 10
Horizontal flue accessories 3 1 Bends 145° (packBends of 2) 45° (pack of 2) 303911 2 Elbow
30321187°
303911 303211 303910 303210 8
1 1 3 4 54 Vertical flue accessories12 3 Flue terminal for ridge tile 303982 -
4 5 6
Component Description
Part Number
Part Number 3
3
Part Number
Part 4
Number 5
5
8 2 1 Elbow 287° Vertical
Bends 45°Elbow flue
(pack87° of accessories 303910 303911 303910
2) flue accessories
Air/flue
303210 duct extension (470mm)
303211 303210
303902 303202
Component4 5 6 Description Ø60/100
Ø60/100
Ø80/125
Ø80/125
8
Vertical flue accessories 3
Vertical
Air/flue duct extension (470mm) 4 Air/flue
303902 duct extension
303202 (970mm) 303903 303203
3 Air/flue duct extension (470mm) 303902 303202 Part Number Part Number
1 1 Horizontal flue accessories 1 Horizontal Telescopic air/flue duct 303936 -
The overall maximum flue length must not
4
2 be exceeded
Air/flue
Elbow
4 Air/flue
duct
87°
Component
Air/flue
Component
extension
Description 303910
duct extension
(970mm) Description(970mm)
303903 5 Air/flue
303903
303203
303210
Part
ductNumber
Ø60/100 extension
303203
Part
(1970mm)Number 303905
Ø80/125
2
2 303205
12
1 3 duct extension (470mm) 303902 303202 Part Number Part Number 12
Part Number Part Number Ø60/100 Ø80/125 3, 4, 12 9
1 with elbow Horizontal Telescopic air/flue duct 303936 - Component Description
and terminal
with elbow and terminal Component 5Description Air/flue 5 duct Air/flue
extension duct
(1970mm) extension (1970mm)
303905 6 Vertical
303905
303205 air/flue2 duct and terminal Ø80/125
Ø60/100
303205 0020065937 3032002 5 8
2 4 Air/flue duct extensionØ60/100 (970mm) Ø80/125 303903 303203 8 6
2 22 Horizontal air/flue duct
3 with elbow 0020178285 - 9
Horizontal air/flue duct with elbow 0020178285 - 6 6 air/flue duct1Vertical air/flue
Bends duct and
45°0020065937
(pack terminal
of 2)7 Flexible Roof
0020065937 303911 Seal
303200 303211 3, 4, 5 3, 4, 5
303980 1
303980 9 712 8 11
4 5 6
2 and terminal 1770mm
and terminal61770mm 7
3 4
9
5
10 5 Vertical
11 Air/flue duct
1
and terminal
extensionBends (1970mm)
45° (pack of 303905 303200303205
2) 303911 303211 6 8 6
6 7 8 Flat roof penetration collar 009056 009056 9
3 Bends 45° (pack of 2) 303911 303211 9 107 45° (pack
6 Flexible
11 7 Roof Seal Flexible
2air/flue ductRoof
Elbow Seal
1 and 87° 303980
Bends 45° (pack of 2) 303980
303980303200 303980
303910 303911 303210 3,303211 4, 5
4
3
Elbow 87°
Bends 45° (pack of 2) 6
4 303910
303911 7 303211
303210
1 Bends of 2) Vertical 2 Elbow terminal
303911 87° 0020065937
303211 303910 303210 6
1 4 Elbow 87°
3 5
303910 303210 8 87° 7 Flat roof 8 Flexible 3Flat
penetration
Roof roof
collar
Seal penetration
Air/flue duct
2 collar
009056
Elbow 87°9303980
extension (470mm) Sliding
009056
009056 Sleeve
303902009056
303980 303910303202 303210 303915 303215
5
5
Air/flue duct extension (470mm)
Air/flue duct extension (470mm)
303902
303902
303202
303202
2 Elbow Vertical
3 flue
303910 accessories
Air/flue duct extension 303210
10 (470mm)
Adjustable
303902
flue support (pack
303202
of 3) 303935 303616
6 Air/flue duct extension (970mm) 303903 303203 9 duct Sliding9 Sleeve
8 extension Flat roof4Sliding Sleeve
3Air/flue duct extension
303915
Air/flue duct (970mm)
extension303915
303215
(470mm) 303903303215 303902303203 303202
6 Air/flue duct extension (970mm) 303903 303203 3 Air/flue (470mm) 4penetration 303902 collar
Air/flue 303202
duct extension 009056(970mm) 009056
303903 303203 12
7 Air/flue 2duct extension (1970mm) 303905 303205 10 duct 10 Sliding
Adjustable 5
Adjustable
flue support (pack
4 flue
of support
Air/flue
3) duct (pack
extension
303935
Air/flue 11 3)(1970mm)
of
duct extension Telescopic
303935
303616
(970mm) air/flue
303905 duct
Part303616 extension
303903
Number 303205 303906
303203
Part Number - 12 10
7 Air/flue duct extension (1970mm) 303905 303205 4 Air/flue 9 extension (970mm) Sleeve
5Component 303903 303203
Description 303915 303215 12
Horizontal flue accessories
8 Air/flue duct extension (4000mm) 0020104555 -
11 11
Telescopic 6
air/flueTelescopic
duct
Air/flue duct
Vertical
air/flue
extension
5 duct
extension (1970mm)
air/flue duct
extension
303906
Air/flue 12
duct andextension Flue
terminal
303906
-
303905
terminal
0020065937
(1970mm) for ridge
Ø60/100-
303905tile
303205
303200 Ø80/125303982
303205 3, 4, 5- 2 12
10
9
Horizontal flue accessories 8 Air/flue duct extension (4000mm) 0020104555 - 7 10extensionAdjustable 303935 303616 10 9
Horizontal flue accessories 2
9 Plume deflector horizontal (black) 6
0020060584 - 5 Air/flue duct (1970mm) 6 flue support
303905 (pack
Vertical of 3) duct
air/flue 303205 and terminal 0020065937 303200 3, 4, 5 6
8 9
10
Part Number
9
Part
Plume
Plume deflector horizontal (black)
Number
deflector horizontal (white)
0020060584
0020060585 -
-
12 Flue 12and
terminal for7
Flue
ridge Flexible
terminal
6
tile Roof
for ridge Seal
tile
Vertical
303982 air/flue 303982
duct and- 303980
terminal 3, -
0020065937
4, 5 303980 303200 9 3, 4, 5 6
Component Description 3 4
Part Number
10 Ø80/125 Plume 5Part Number 8 00200605858 - 6 12 Vertical air/flue
11 duct terminal
Telescopic 7 0020065937
air/flue duct extension
Flexible Roof Seal 303200 303906 -
303980 303980 6 10 6
Component Description Ø60/10011 Part Number Part deflector
Number horizontal (white)
for horizontal 7
Component Description 6Black
Ø60/100 terminal kitØ80/125 303934 8 -
7
12
Flexible Roof 8 Flat
7 roof
1 303980 penetration
Bends 45°303980
Flexible (pack
Roof collar
of 2)
Seal 009056 303980009056
303911 303211
303980
11 air/flueBlack
Ø60/100 duct terminal kit for horizontal
Ø80/125 303934 - 12 Seal Flue terminal 8 for ridge tile
Flat roof penetration 303982
collar -
009056 009056
air/flue duct 9 2 8Sliding Sleeve
Elbow
Flat 87°roof penetration collar 303915 303910
009056 303215 303210
009056
1 Horizontal
1 Telescopic air/flue
Horizontal duct
Telescopic 303936
air/flue 12
duct -
Standard
303936 Horizontal air/flue
- duct 303933 303209 8 Flat roof penetration collar 9 009056
Sliding Sleeve 009056 303915 303215
12 with elbowStandard Horizontal air/flue duct 303933 303209
with
1 elbowHorizontal
and terminal
with Telescopic
elbow and air/flue
terminalduct 303936 and -terminal
with elbow and terminal 9 Sliding Sleeve 10 Adjustable
3 303915
9 Air/flue
flue duct
Sliding support extension
Sleeve
303215 (pack of (470mm)
3) 303935303902 303915303616303202 303215
2 Horizontal Horizontal
with elbow andflue
air/flue duct accessories
terminal
with elbow 0020178285 - 10 Adjustable flue support (pack of 3) 303935 303616
2 Horizontal air/flue duct with elbow 0020178285 - 11 4 303935
Telescopic
10 Air/flue
air/flueduct
Adjustable ductextension
extension
flue (970mm)
support of 3) 303903
(pack303906 303935 - 303203 303616 10
and
2 terminal 1770mm
Horizontal air/flue duct
and terminal with elbow
1770mm 0020178285 - 10 Adjustable flue support (pack of 11 3) Telescopic air/flue 303616
duct extension 303906 - 10 12
Part Number Part Number
accessories
and terminal 1770mmDescription
Component 9 10
9 1011 8 11 12 5 11 Flue terminal
Air/flue for
duct
Telescopic ridge tile
extension
air/flue (1970mm)
duct extension303982 303905
303906 - 303205- 10
3 Bends 45° (pack
3 Componentof 2) 303911 7 303211 Ø60/100 Ø80/125 11 Telescopic air/flue duct extension 303906 - 10
Bends 45° (pack of 2) Description Part Number Ø60/100 Part Number Ø80/125 Component
Bends
6 45° (pack of 2) 303911 303211 9 10 11 12 Flue terminal for ridge tile 303982 Description - 3, 4, 5 Part
9 Number Ø60/100 Part Number Ø80/125
4 3
Elbow 87°
4 Elbow 87°Number Part Number 303910 303911303910 303210 303211303210 6 12 Vertical air/flue duct
Flue terminal for and terminal
ridge tile 0020065937
303982 303200-
Description 4 Elbow Part
87° (470mm) 303910303202 303210 8 12 Flue terminal for ridge tile 303982 - 6
5 Air/flue duct extension 303902
5
1 ductHorizontal
1 Ø60/100
Air/flue extension Telescopic
(470mm) air/flue duct
Ø80/125
Horizontal Telescopic 303902 303936
air/flue 303202duct with- elbow and terminal 303936 – 7 Flexible Roof Seal 1 303980Bends 45° 303980 (pack of 2) 303911 303211
6 5
Air/flue Air/flue duct (970mm)
6duct extension
extension
Air/flue duct with (470mm)
elbow
extension 303903 303902
and terminal
(970mm) 303203 303202
303903 303203
6
Air/flue Air/flue duct extension (970mm) 303905 303903303205 303203 8 Flat roof penetration collar 009056 009056
7
rizontal Telescopic air/flue 7duct extension
2 (1970mm)
duct Air/flue ductHorizontal
303936 extension air/flue- duct with elbow
(1970mm) 303905 0020178285
303205 -
7 Air/flue 2 duct extension
and Horizontal
(1970mm)
terminal 1770mm
0020104555air/flue
303905duct with elbow
303205 and terminal 1770mm 0020178285 – 9 Sliding Sleeve 2 Elbow 87° 303215
303915 303910 303210
h elbow 8and terminalAir/flue
8 duct extension
Air/flue(4000mm)
duct extension (4000mm) -
0020104555 -
8 Air/flue 0020104555- - 9 10 11
9 Plume deflector
rizontal air/flue duct with9elbow Plume 3duct extension
horizontal (black)
Bends
deflector
0020178285
(4000mm)
45° 0020060584
(pack
horizontal -of 2)
(black) 0020060584303911 - 303211 10 Adjustable flue support (pack of 3) 303935 303616
43 Bends 45° (pack of 2)- 303911 303211 3 Air/flue duct extension (470mm) 303902 303202
9
101770mmPlume Plume horizontal
deflector deflector horizontal
(white) (black)
0020060585 0020060584 -
d terminal 10 Plume Elbow
deflector 87°
horizontal (white) 0020060585 303910 - 303210 12
rt Number Part10NumberPlume deflector horizontal (white)
11 Black terminal kitBlack
5for horizontal 8303934 0020060585- 9 - 10303202 11 12 11 Telescopic air/flue duct extension 303906 - 10
ds 45° (pack of 2)Ø80/125
Ø60/100 11 303911Air/flue
terminal duct
kit for extension
horizontal
303211 (470mm) 303934 303902 - 12
air/flue duct
11 Black terminal kitAir/flue
for horizontal 303934 -
ow 87° 4
air/flue
6
air/flue duct303910
duct Elbow
duct 87°
extension
303210 (970mm) 303903 303203 303910 303210 12 Flue terminal for ridge tile 4 Air/flue duct extension
303982 - (970mm) 303903 303203
12 Standard
12 Horizontal 7 air/flue
Standard duct duct
Air/flue
Horizontal 303933
extension
air/flue 303209 303905
duct(1970mm) 303933 303209 303205
/flue
303936duct extension (470mm)
- elbowStandard 303902 303202
with
12 and terminal
with Horizontalandair/flue duct 303933 303209
/flue duct extension (970mm) with elbow 85 elbow
303903
terminal
Air/flue
Air/flue
and terminal
duct303203 duct(4000mm)
extension extension (470mm)
0020104555 - 303902 303202 5 Air/flue duct extension (1970mm) 303905 303205
/flue duct extension (1970mm) 9 303905Plume deflector 303205horizontal (black) 0020060584 -
20178285 -
10 0020104555 Plume deflector-horizontal (white) 0020060585 -
/flue duct extension (4000mm) 6 Air/flue duct
9 terminal kit for
extension
10 horizontal 11
(970mm) 12 303903 303203 6 Vertical air/flue duct and terminal 0020065937 303200
me deflector horizontal 11 0020060584Black - 303934 -
303911 303211 (black)
air/flue duct
me deflector horizontal
303910 303210(white) 70020060585
12 303934
Air/flue- duct
Standard Horizontal
extension (1970mm)
air/flue duct 303933 12 303209
303905 303205 7 Flexible Roof Seal 303980 303980
ck terminal kit for303202
303902 horizontal -
/flue duct with elbow and terminal
303903 303203
ndard Horizontal 303205
air/flue duct
8 303933
Air/flue duct extension (4000mm)
303209
0020104555 – 8 Flat roof penetration collar 009056 009056
303905
h elbow and terminal
20104555 -
20060584 -
9 Plume deflector horizontal (black) 0020060584 – 9 Sliding Sleeve 303915 303215
20060585 -
303934 - 10 Plume12deflector horizontal (white) 0020060585 – 10 Adjustable flue support (pack of 3) 303935 303616

303933 303209 11 Black terminal kit for horizontal air/flue duct 303934 – 11 Telescopic air/flue duct extension 303906 –
32 12 Standard Horizontal air/flue duct with elbow and terminal 303933 303209 12 Flue terminal for ridge tile 303982 – 33
34
Combi boiler with timeSWITCH 150, VRT 50, single zone - schematic
The TECHNICAL Brochure

Combi boiler with timeSWITCH 150, VRT 50, single zone - wiring

Schematics and
35

wiring diagrams
36
Combi boiler with timeSWITCH 160, VRT 15, single zone - schematic
The TECHNICAL Brochure

combi boiler with timeSWITCH 160, VRT 15, single zone - wiring

Schematics and
37

wiring diagrams
38
Combi boiler with VRT 350, single zone - schematic
The TECHNICAL Brochure

Combi boiler with VRT 350, single zone - wiring

Schematics and
39

wiring diagrams
40
Combi boiler with VRC 470, single zone - schematic
The TECHNICAL Brochure

Combi boiler with VRC 470, single zone - wiring

Schematics and
41

wiring diagrams
42
Combi boiler with two VRT 350, VR 66, 2 zone - schematic
The TECHNICAL Brochure

Combi boiler with two VRT 350, VR 66, 2 zone - wiring

Schematics and
43

wiring diagrams
44
System boiler with VRC 470, VR61, VR 81, 2 zone - schematic
The TECHNICAL Brochure

System boiler with VRC 470, VR61, VR 81, 2 zone - wiring

Schematics and
45

wiring diagrams
The TECHNICAL Brochure

UniSTOR unvented cylinders

unvented cylinders
UniSTOR
uniSTOR is a range of six high grade stainless steel unvented
cylinders from Vaillant. Finished with stylish casing, they are
available in a range of sizes from 120 litres to 310 litres.
The uniSTOR stainless steel cylinder range can be Key features and benefits:
used together with any Vaillant system and open uniSTOR stainless steel unvented cylinder 120 155 180 210 260 310
• uniSTOR cylinders operate using a mains water Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905
vent boiler (or any existing system or open vent
pressure supply and do not require a feed from
boiler). They work in perfection when used with External case height (mm) 1001 1191 1371 1593 1843 2153
a cold water storage tank
the ecoTEC range of system boilers, where they Diameter (mm) 554.5 554.5 554.5 554.5 554.5 554.5
can make full use of Vaillant’s intelligent • All necessary cold and hot water controls and a Approx weight when empty (Kg) 26 29 32 36 41 46
ebus temperature sensing controls as part 2-port valve for control of domestic hot water
of Vaillant’s Total System Solution. are supplied
• All uniSTOR cylinders are backed by a full 2
year guarantee as well as a 25 year guarantee
on the cylinder shell
46 47
• Complete with G3 kit and expansion vessel
uniSTOR technical specification

uniSTOR 120 / 155 / 180 / 210 / 260 / 310L uniSTOR 120 / 155 / 180 / 210 / 260 / 310L

uniSTOR uniSTOR uniSTOR uniSTOR

Technical data Unit 120 155 180 210 260 310 Technical data Unit 120 155 180 210 260 310

Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905 Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905

Total capacity l 120 155 180 210 260 310 Height mm 1001 1191 1371 1593 1843 2153

Actual capacity l 119.2 149.1 176.6 211.2 250.3 298.5 Height with hot water draw off l 1033 1223 1403 1625 1875 2185

Hot water capacity l 1040 1367 1664 2039 2475 2705 Topple measure mm 1138 1308 1473 1680 1918 2217

Diameter mm 554.5 554.5

unvented cylinders
Maximum supply pressure
MPa (bar) 1.2 (12) 1.2 (12)
to pressure reducing valve Depth mm 633 633

UniSTOR
Rated pressure Net weight kg 26 29 32 36 41 46
MPa (bar) 0.7 (7) 0.7 (7)
of cylinder
Weight (full) kg 145 177.8 209 248 291 345
Maximum operating
MPa (bar) 0.35 (3.5) 0.35 (3.5) Connections
pressure of heating coil
Cold water inlet 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Pressure reducing valve MPa (bar) 0.35 (3.5) 0.35 (3.5)
Hot water draw off 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Expansion relief valve MPa (bar) 0.6 (6.0) 0.6 (6.0)
Pressure-controlled cold water
22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Temperature and pressure °C 90 90 inlet
relief valve MPa (bar) 0.7 (7) 0.7 (7)
Secondary return 15mm unprofiled pipe (crimp joints) 15mm unprofiled pipe (crimp joints)

Charge pressure of hot Primary heater flow 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
MPa (bar) 0.4 (4) 0.4 (4)
water expansion vessel
Primary heater return 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Maximum temperature of
°C 85 85 Primary heating circuit
heating circuit mm 8 8
immersion sleeve size
Maximum temperature of Electrical connections
°C 85 85
potable hot water
Immersion heater (according
2.7 kW, 230 V, 50 Hz 2.7 kW, 230 V, 50 Hz
Standing heat loss kW/24 h 1.26 1.53 1.66 1.89 2.07 2.26 to ENBS 60335)

Length of immersion heater inch 14 14


Heat up time according
mins 18 23 24 28 35 42
to EN 12897
Two port motorised valve 230/240 V, 50 Hz 230/240 V, 50 Hz

Recovery time Cylinder thermostat 230/240 V, 50 Hz 230/240 V, 50 Hz


kW 16 18 17 20 25 30
(70% capacity)
Material data
Primary heat exchanger
l/min 18.6 18.8 22.0 22.6 22.3 20.4 Cylinder body material Stainless steel (1.4521) Stainless steel (1.4521)
performance
Cylinder jacket material Polypropylene Polypropylene
Flow rate for primary heat
l/min 23.3 23.3
exchanger performance Insulation material EPS with heat radiation absorber EPS with heat radiation absorber

Primary heat exchanger Insulation thickness mm 50 50


mbar 97 97 116 116 116 115
pressure drop
Corrosion protection Stainless steel Stainless steel
Primary heat exchanger Blowing agent for insulation
l 2.94 2.94 3.56 3.56 3.56 3.56 Pentane (GWP < 5) Pentane (GWP < 5)
volume material

Primary heat exchanger Ozone Depletion Potential 0 0


m2 0.62 0.62 0.75 0.75 0.75 0.75
surface area

48 49
The TECHNICAL Brochure

Weather compensating controls VRC 470f Intelligent room compensators VRT 350 and VRT 350f

Weather compensating
controls
Our intelligent compensating controls give you even You have a choice of what kind of controls you have to
more control over your heating system so that you can manage your boiler. The more sophisticated the control,
ensure that it’s working as efficiently as possible. the more control you have over your heating system.
The VRC 470f is a unique wireless weather Key features and benefits: Our intelligent room compensating controls allow Key features and benefits:
compensating control. Constantly monitoring the you to fine tune your heating system, giving you
• Intelligent time and temperature control for central • Intelligent time and temperature control of
temperature outside, it intelligently adapts to even more control. These controls allow you to
heating and domestic hot water heating and domestic hot water
optimise the boilers output for maximum efficiency turn your system on or off at different times of
and home comfort. • Classed as enhanced load compensator adding 3% • New attractive, easy-to-use design with blue
the day, and continually monitors and adapts to
to the SEDBUK efficiency rating backlit display
Featuring a backlit plain text display with a single give you the desired room temperature. The blue
• Cylinder boost function backlit screen and plain text display make the VRT • Automatic summer/winter time change over
rotary knob which, together with numbered screens,
make navigation easy. It has time and temperature • Holiday function 350 and VRT 350f easy and clear to understand. • Five operation modes: automatic, summer,
controls for heating and hot water channels and an • Includes a service reminder function Only two push buttons and one rotary knob are comfort, set-back and system off
additional timed channel for a circulation pump. • Automatic summer/winter time change over needed to select and change data. • Two temperature setting levels: desired and
set-back temperatures
Programming for 7 day, 5 day/2 day or 24 hours, • Wireless control Plus, when you go on holiday the VRT 350 and
operation is possible with 3 different time windows VRT 350f have a holiday set-back function, which • Cylinder boost option
• Supplied with outdoor sensor which monitors
per day with one comfort and setback temperature the outdoor temperature reduces the temperature in your property and • Wireless control (VRT 350f only)
for all time periods. heats it up before you come back home.
• Receiver can be fascia or wall-mounted
Additional features include; set-back temperature,
heating and hot water advance, automatic summer
to winter changeover, holiday mode, and optimum
start/stop. With additional accessories the VRC 470f
can be used to control two heating zones and hot
water circuits. Simple two-wire low voltage eBUS
50 connections make installing the VRC 470f easy to fit 51
into the boiler fascia for true plug and play flexibility.
The TECHNICAL Brochure

timeSWITCH controls Room thermostats

Proper control of central heating and domestic hot water systems


can provide a comfortable living environment and help to minimise Central heating and domestic hot water controls
fuel costs. are key to delivering greater efficiency.

timeSWITCH 150 timeSWITCH 160 Room thermostat VRT 15 Room thermostat VR81

timeSWITCH controls
Our basic boiler control allows you to adjust the The timeSWITCH 160 can be used with all Vaillant This easy-to-use, simple room thermostat works The display of the VR 81 shows the current room
heating programme by choosing when you would like ecoTEC boilers and mounts directly into the front with the timeSWITCH 160. This thermostat is temperature. With the ‘turn and click’ handling, the
compatible with all ecoTEC boiler models.
your system to switch on or off, and how long you of the boiler without the need for any wiring. desired room temperature can easily be changed.
would like it to operate for. This timer gives you control of your central heating Key features and benefits: The remote control unit VR 81 has two possible
and domestic hot water with a timed programming • Simple 230V analogue room thermostat functions: In a single-zone heating system, the VR 81
The timeSWITCH 150 is compatible with all Vaillant
function. With the added option of up to three • Compatible with timeSWITCH 160 will be installed on the wall inside a living area while
ecoTEC combi boilers and plugs directly into the
programme times per day, seven days a week, • Easy to use the weather compensator VRC 470 remains in the
boiler without the need for any wiring. This timer
for added flexibility and comfort. boiler fascia. When used with a two zone heating
provides easy-to-use, basic timing for your central
Room thermostat VRT 50 system the VR 81 becomes the room thermostat
heating needs. Key features and benefits: This easy-to-use, intelligent VRT 50 digital for the second heating zone while the weather
• Two channel digital timer room thermostat shows the current room compensator VRC 470 or VRC 470f would act
Key features and benefits: temperature and can be used with Vaillant
• Mounts directly into boiler fascia as a room thermostat for the first heating zone.
• Single channel analogue timer ecoTEC plus combi boilers and the timeSWITCH
• Controls heating and domestic hot water 150 central heating timer. For this installation an additional VR 61 wiring
• Mounts directly into boiler fascia centre is required.
timed programmes The thermostat can be set to intelligent control,
• 24-hour timer for central heating
• Holiday function—days away from home which provides greater efficiency and a more
• Compatible with all Vaillant combi boilers comfortable room temperature.
scheduling
• Compatible with VRT 50 digital room thermostat Key features and benefits:
• Compatible with all Vaillant system and
heat-only appliances • Compatible with timeSWITCH 150
52 53
• Compatible with the VRT 15 room thermostat • Easy to use
54
Controls compatibility finder

This guide will assist you in selecting the correct control for your heating system.
Simply select which boiler type you have, and follow the columns on the table to show you the controls compatible with your system.

Heating system Control Wiring centres Thermostats


Weather Wired/ Facia timeSWITCH timeSWITCH
Boiler Zones Solar VRT 350 VRT 350f VRC 470 VRC 470f VR66 VR 61 VR 68 VRT 15 VRT 30 VR 81
comp Wireless mounted 150 160
The TECHNICAL Brochure

Wired Yes No ü ü
Wired Yes No ü ü
No
Wired No No ü
1 Wireless No No ü
Wired Yes No ü ü
Combi
Yes Wired No No ü
Wireless No No ü
No Wired No No ü ü
2 Wired No No ü ü ü
Yes
Wireless No No ü ü ü

Wired Yes No ü ü ü
Wired Yes Yes ü ü ü ü
Wired No No ü ü
No
Wired No Yes ü ü ü
Wireless No No ü ü
Wireless No Yes ü ü ü
1
Wired Yes No ü ü ü
System Wired Yes Yes ü ü ü ü
or
Wired No No ü ü
open Yes
vent Wired No Yes ü ü ü
Wireless No No ü ü
Wireless No Yes ü ü ü
No Wired No No ü ü
Wired No No ü ü ü
2 Wired No Yes ü ü ü ü
Yes
Wireless No No ü ü ü
Wireless No Yes ü ü ü ü
Vaillant Advance

55

Vaillant Advance
The TECHNICAL Brochure

The Vaillant service standard The Vaillant service standard

Renewable calculator
This helpful tool is designed to help you
discover how much money and CO2 you could
save by installing a Vaillant renewable heating
or hot water system in your home.

Service
Go to www.vaillantrenewables.co.uk

Installer technical helpline


Whether working on new or old Vaillant products,
we have a team of dedicated technical experts
waiting to answer any specific technical queries
you have during installation or servicing. Please call
01732 878 803 to speak to our expert advisors.

End user technical helpline


Should you have any questions once your boiler is
installed, such as how to change the timer settings.
Spares availability call 0330 100 3461 for assistance.
We are committed to responsible spares provision
and provide spares for a minimum of 15 years after
product discontinuation. We have a nationwide
network of genuine spares stockists and a
dedicated spare parts team to help you identify
the parts you require, call 01773 596 615.

As well as our range of ecoTEC


domestic boilers, we’re proud
to have a whole suite of
Commercial and Renewable
Here at Vaillant, we invest as much time, energy and effort into getting heating and hot water solutions:
outstanding service as we do in creating industry leading heating and We offer a wide range of:
renewable solutions. So you know when, you choose us, you will be Commercial wall hung and floor standing
ecoTEC boilers
supported by the best. aroTHERM air to water heat pumps
aroTHERM air to water hybrid systems
geoTHERM ground source heat pumps
With Vaillant, you’ll find that help is never far away. Next day service
auroTHERM solar systems
We have Vaillant operators available at the end of Vaillant employs 250 dedicated service engineers, so
dedicated phone lines, 7 days a week, 364 days we can offer all our customers a next day service, if
a year, able to arrange for a local Vaillant service required. Making sure that if you need us, we will be
For further information
engineer to attend on site. Moreover, our operators there.
on our range of
are qualified experts who can call upon a wide
Outstanding first fix rate renewable systems,
technical knowledge of Vaillant appliances and
When we get to you we can fix the problem and have visit www.vaillant.co.uk
supply you with right first time advice over
a staggering 98% first fix rate. This is because our or contact your local area
the phone.
engineers are expertly trained on all of our products representative.
56 and carry 95% of all Vaillant spare parts on their vans. 57
The TECHNICAL Brochure

Vaillant Training

Vaillant Training
Industry leading training designed for Dedicated state of the art Centres of Simpler, smarter, state of the art e-learning
industry leading engineers. Excellence. Experience from Vaillant.
With a team of fully qualified industry experts, our Located in Glasgow, Elland (near Leeds), Belper a new Here at Vaillant, we know that time is money. That is
training courses have been designed and tailored (near Derby), Cambridge, Farnborough, Bristol and age of why our new blended approach to training combines
to keep you one step ahead of the ever-developing Maidstone you can rest assured there is a centre training convenient online tuition with expert hands-on
world of heating and hot water technologies and never far away from where you are. Our centres innovation training at our cutting edge nationwide Centres of
Glasgow
industry regulations. have been developed and designed with you in today. Excellence. Proven to be 60% quicker and twice as
mind, offering spacious facilities, a comfortable effective*, Vaillant training means you can be the
We offer the full package of courses for all levels
and superbly equipped training environment, with expert engineer without compromising time with
within the industry. From a full day getting hands
plenty of opportunities for hands on experience and your customers. Experience the new
on with the ecoTEC range of domestic boilers to
product familiarisation. age of training today innovation today at
our aroTHERM air to water heat pumps – we have Elland (Leeds) Belper (Derby)
www.vaillant.co.uk
a course for you.
Cambridge

Bristol

Maidstone
58 Farnborough 59

* Twice as effective and 60% quicker when combined with traditional practical training
The TECHNICAL Brochure

Order Numbers Order Numbers

You will find the relevant article numbers referenced throughout this brochure. However for ease of ordering,
Passive Flue Gas Heat Recovery Device Article Number
all ecoTEC components are summarised below:
recoFLUE PFGHRD 0020152033
High efficiency combination boilers Article Number
ecoTEC plus 825 0010018353 High efficiency flues - 100mm

ecoTEC plus 832 0010018354 Standard horizontal air/flue duct with elbow and terminal 303933
Vertical air flue duct and terminal 0020065937
ecoTEC plus 832 LPG 0010018355
Flat roof penetration collar 009056
ecoTEC plus 835 0010016540
Pitched roof adjustable roof tile 009076
ecoTEC plus 838 0010018356
Flexible roof seal 303980
ecoTEC plus 938 0010018375
Horizontal telescopic air/flue duct with elbow and terminal 303936
ecoTEC pro 24 0010018494
87° elbow 303910
ecoTEC pro 28 0010018495
45° bends (x 2) 303911
ecoTEC pro 28 LPG 0010018496
Air/flue duct extension (470mm) 303902
ecoTEC pro 30 0010016538
Air/flue duct extension (970mm) 303903

Order numbers
ecoTEC exclusive 832 0010002668
Air/flue duct extension (1970mm) 303905
ecoTEC exclusive 838 0010002669
Air/flue duct extension (4000mm) 0020138174
High efficiency system boilers Telescopic air/flue duct extension 303906
ecoTEC plus 612 0010018531 Telescopic offset 303919
ecoTEC plus 615 0010018532 Sliding sleeve 303915
ecoTEC plus 618 0010018533 Flue support clips (x 5) 303821
ecoTEC plus 618 LPG 0010018534 Adjustable flue support (x 3) 303935
ecoTEC plus 624 0010018535 Black terminal kit for horizontal air/flue duct 303934
ecoTEC plus 630 0010018536 Plume deflector horizontal (black) 0020060584
ecoTEC plus 630 LPG 0010018537 Plume deflector horizontal (white) 0020060585
ecoTEC plus 637 0010018538 Flue terminal for ridge tile 303982

High efficiency open vent boilers Variable termination kits


ecoTEC plus 412 0010015669 Variable termination kit - black 303942
ecoTEC plus 415 0010015670 Extension pipe for variable termination kit - black (1m) 303943

ecoTEC plus 418 0010015671 90° elbow for variable termination kit - black 303944

ecoTEC plus 424 0010015672 45° bend for variable termination kit - black (2 pieces) 303945
Variable termination kit - white 303946
ecoTEC plus 430 0010015673
Extension pipe for variable termination kit - white (1m) 303947
ecoTEC plus 438 0010002725
90° elbow for variable termination kit - white 303949
Single coil cylinders 45° bend for variable termination kit - white (2 pieces) 303948
uniSTOR 120 0010010900
High efficiency flues - 125mm
uniSTOR 155 0010010901
Optional boiler flue adaptor (100mmø to 125mmø) 303926
uniSTOR 180 0010010902
Optional boiler flue adaptor (100mmø to 125mmø) - bayonet 0020147469
uniSTOR 210 0010010903
Horizontal air/flue duct with elbow and terminal 303209
uniSTOR 260 0010010904
Vertical air/flue duct and terminal 303200
uniSTOR 310 0010010905
87° elbow 303210
Controls Two 45° bends 303211
timeSWITCH 150 0020116882 Air/flue duct extension (470mm) 303202
timeSWITCH 160 0020124498 Air/flue duct extension (970mm) 303203
VRT 15 306777 Air/flue duct extension (1970mm) 303205
VRT 50 0020018265 Sliding sleeve 303215
VRT 350 0020124475 Flue support clips (pack of 5) 303616
VRT 350f 0020124482
Accessories
VRC 470 0020108130
Spacing frame accessory 308650
VRC 470f 0020108137
Boiler security bracket 2370109
VR 81 0020129323
Pipe cover accessory 2378099
VR 66 0020135785
ecoLEVEL condensate pump 0020030797
VR 40 0020017744
Remote PRV mounting kit 0020094185
VR 61 0020139853
60 61
VR 68 0020139859
VR32 0020139895
The TECHNICAL Brochure

Notes Notes

62 63
Training Enquiries After Sales

For information on training courses For support after your boiler has
and centres in your area: been installed, whether you would
Telephone: 0845 601 8885 like to book a service or are in need
Email: training@vaillant.co.uk of technical advice, our operators are
available 7 days a week, 364 days a
year.
Telephone: 0330 100 3143

Sales Enquiries Technical Enquiries

For installers wishing to purchase For technical assistance:


Vaillant products, this is possible Telephone: 01732 878803
either over the counter or as a next Email: technical@vaillant.co.uk
day service at most plumbing and
heating merchants in the UK.
To find contact details for your
nearest Vaillant sales representative:
Telephone: 0845 602 0262

Vaillant Group UK Ltd.


Nottingham Road, Belper, Derbyshire DE56 1JT
www.vaillant.co.uk info@vaillant.co.uk

64
VAECOTEC | V3 August 16

Anda mungkin juga menyukai