T1X
Size 52 to 150
Up to 31.5 MPa
Up to 15000 L/min
Introduction
Symbol :
P1 P2
4 3 2 1
The check Valve type S is used to permit free flow in one direction and to be closed
in opposite direction with leakage-free.
It basically comprises of the housing (1), poppet (2) and the compression spring (3) P1 P2
and the spring seat (4).
The stroke of the poppet (2), which is guided on its outside diameter, is limited by a
mechanical stop-----the spring seat(4). The built-in compression spring (3) supports 3 2 1
the closing movement. furthermore the compression spring (3) holds the poppet (2)
in the closed position even when there is no flow through the valve.
When fluid flows through the valve in the opening direction, the poppet (2) lifts due
to the fluid pressure. In the opposite direction the compression spring (3) and the
fluids presses the poppet (2) onto its seat (4) and thus closes the connection.
P2 P1
As for the check valve without spring, the fixing position should ensure that the
poppet can locate itself closed under its deadweight.
1/2
Ordering details
S T1X
Technical Data
1/2
Characteristic Curve (Measured at t=40 C +5 C, using HLP46)
Pressure difference P in relation to the flow Q at opening pressure
Size 52 Size 62
1.0 1.2
0.9 1.1
0.8 1.0
Pressure differential (MPa)
0.9
0.8 0.8
0.7 0.7
0.6 0.6
0.5 0.5
0.4 0.4
3
0.3 0.3
2 2
0.2 0.2
1 1
0.1 0.1
0 0
0 0
1000 2000 3000 4000 5000 1400 2800 4200 5600 7000
0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
1 1
0.1 0.1
0 0
0 0
2000 4000 6000 8000 10000 30 60 90 120 150
Flow (L/min) Flow (L/min)
1/2
Unit Dimensions : sub-plate mounting (Dimensions in mm)
H2
H1
OD2;T1
SW
O D1 R
1. Free flow in direction of arrow
2. Name plate
L8
L7 3. Eyebolt for transport
1 pcs with sizes 52 and 62
O D3 L6 L5 2 pcs with sizes 82
2 P1
O D2max
B3
B2
B1
P1
P2 1
B1
B2
L1 P2
L2
L1
L3
L4 6XD4;T2 L2
L3
L4
0.01/100mm
0.8
62 40 140 180 70 60 22 125 161 34 65 100 128 17.5 96 220 263 2.7 17 38
82 50 170 210 92 80 22 155 191 30 70 115 140 35 105 275 325 2.7 19 70
1/2
Unit Dimensions : flange connection sizes 52 to 102 (Dimensions in mm)
3
2
H2
D3;T2
P2 P1 D4
D1
H1
D1
1
L1
45
L2
B1
2. Name plate
B2
Size B1 B2 D1 D2 D3 D4 H1 H2 L1 L2 T1 T2 Weight kg
1/2
Unit Dimensions : flange connection sizes 125 to 150 (Dimensions in mm)
D3;T1
D2
P2 D4
H1
D1
P1
D1
45
22.5
L1
2. Name plate
2
3. Eyebolt for transport
For suitable connection flanges see Lc455
Size D1 D2 D3 D4 H1 L1 T1 Weight kg
1/2
The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.
THM