Anda di halaman 1dari 2

Design of Corbel (ACI 318-08, Section 11.

8)

Design Shear (Factored) V = 163 kN


Design Tension (Factored)(Min = 20% of V) N = 40.75 kN
Grade of Concrete f'c = 32 N/mm²
Grade of Steel fy = 420 N/mm²
Width of Corbel b = 1000 mm
Total Depth of Corbel h = 300 mm
Eccentricity of Load V av = 150 mm
Cover to Main Reinforcement co = 70 mm
Assume Dia of Main Reinforcement db = 16 mm
Effective Depth d = h - co - db/2 = 222 mm
Strength Reduction Factor φ (Section 11.8.3.1) = 0.75
Check av/d < 1 OK

Design for Flexure + Tension (Section 11.8.3)


Design Moment Mu = V×av + N×(h-d) = 27.6 kNm
Assume area of Steel for Flexure Af = 550 mm²
Now, Design Moment ≤ Design Capacity Mu ≤ φMn
Depth of Equiv. Rect. Stress Block a = Af×fy/ (0.85×f'c×b) = 8.5 mm
Fexural Capacity of Section φMn = φ×Af×fy×(d-a/2) = 37.7 kNm
Check Mu ≤ φMn OK
Area of Steel Required for Direct Tension An = N/(φ×fy) = 129 mm²
Total Area of Steel Required As = Af + An = 679 mm²

Design for Shear (Section 11.8.3.2 and 11.6)


Coefficient of Friction µ = 1.4
Area of Shear Friction Rein Reqd Avf = V/(φ×µ×fy) = 370 mm²
Check OK
Design Reinforcement (Section 11.8.3.5, 11.8.4, 11.8.5)
Area of Main Reinforcement (Asc) shall be larger of 1) or 2)
1) Asc = Af + An = 679 mm²
2)Asc = 2/3×Avf + An = 376 mm²
Therefore, Area of Main Reinforcement Reqd Asc = 679 mm²
Minimum Area of Main Reinf Asc = 0.04×f'c×b×d/fy = 677 mm²
Check OK
Area of Strirrups Parallel to Main Reinforcement Ah = 0.5×(Asc-An) = 275 mm²

Reinforcement Summary
No of No of
Dia Spacing Area Check
Bars Layers
[mm] [mm] - - [mm²]
Asc 16 250 4.0 1.0 804 OK
Ah 10 250 4.0 2.0 628 OK