t ion :
su m p
r co n
p o w e
d u c e d rcuit]
Re s a v i ng ci
5 w [With p
ow e r
1. 5 5 ti onal
: 2.0
W)
[Standa
∗ Wit
h DC li
ght
0.55 W
With power saving circuit
0W
40 ms
Strainer
1 3 1/4
8.9 (P) (R) P. 1
3/8
M-type plug
connector
External pilot
VP700 N.C./N.O.
(A)
2 DC
3/8 12 VDC L With surge voltage
15.3
1 3 1/2 24 VDC suppressor
(P)(R) Push-turn
L With light/surge locking
Solenoid valve
1 3
(P) (R)
Conduit
VP700 X terminal
N.O.
(A)
2 3/8
15.0
1/2
1 3
(P) (R)
Features 1
Series VP300/500/700
VV3P3-41
Common EXH
Individual EXH
VV3P5-41
Common EXH
Solenoid valve
Base mounted
Individual EXH
VV3P7-41
Common EXH
Individual EXH
Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or more.
Features 2
Series VPA300/500/700
VPA300
N.C.
(A)
2 1/8
4.2 12
1/4
1 3
(P) (R)
VPA500
N.O.
Body ported
(A)
2
12 1/4
8.9 P. 25
3/8
1 3
(P) (R)
VPA700
For vacuum
N.C./N.O.
(A)
2 3/8
15.3 12
1/2
Air operated valve
1 3
(P) (R)
— — — —
VPA300 N.C.
(A)
2
12
1 3
1/8
3.8
(P) (R) 1/4
N.O.
(A)
2
12
VPA500
Base mounted
1 3
(P) (R)
1/4
8.8 P. 30
For vacuum 3/8
N.C.
(A)
2
12
VPA700 1 3
(P) (R)
N.O. 3/8
15.0 (A)
2 1/2
12
1 3
(P) (R)
Features 3
Series VPA300/500/700
VV3PA3-41
Common EXH
Individual EXH
VV3PA5-41
Common EXH
Air operated valve
Base mounted
Individual EXH
VV3PA7-41
Common EXH
Individual EXH
Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or more.
Features 4
Rubber Seal
3 Port/Pilot Poppet Type
Body Ported/Single Unit
Series VP300/500/700
Note) Only DIN and conduit terminal types
are available for AC mode.
How to Order Refer to the electrical entry for details.
Body ported VP 3 4 2 5 G 1 01 A
Series
3 VP300
Pilot type
Nil Internal pilot
Thread type Bracket
5 VP500
R External pilot Nil Rc Nil Without bracket
7 VP700
F G F With bracket
Pressure specification N NPT
Nil
T NPTF
Standard (0.7 MPa)
K High-pressure type (1.0 MPa)
Coil specification
Nil Standard
T With power saving circuit (DC only) Rated voltage
Note) Be sure to select the power sav-
Type of actuation
DC
ing circuit type when it is continu- A N.C. (Normally closed)
ously energized for a long time. 5 24 VDC B N.O. (Normally open)
(Refer to back page 5 for details.) 6 12 VDC
∗ T type is only available for DC mode. Port size
When T is selected, only Z type of AC (50/60 Hz)
light/surge voltage suppressor is Symbol Port size VP300 VP500 VP700
1 100 VAC
available. 01 1/8
(Note that when the electrical entry of
2 200 VAC
02 1/4
DIN terminal type without connector is 3 110 VAC [115 VAC]
03 3/8
selected, only DOS and YOS are 4 220 VAC [230 VAC]
available.) 04 1/2
7 240 VAC
B 24 VAC
Made to Order
Nil —
Electrical entry
Pilot exhaust port with piping thread (M3)
DIN X500 specification (Refer to page 24).
L-type plug M-type plug DIN Conduit
Grommet (EN175301-803)
connector connector terminal terminal Interchangeable specification with the
terminal
X505 previous valve mounting hole pitch type
[IP65 compatible] [IP65 compatible] [IP65 compatible] (Refer to page 24).
Manual override
Nil: Non-locking D: Push-turn locking E: Push-turn locking
push type slotted type lever type
G: Lead wire L: With lead wire M: With lead wire
length 300 mm (length 300 mm) (length 300 mm)
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal
LN: MN:
Without lead wire Without lead wire Light/surge voltage suppressor DC AC
G: Lead wire Nil Without light/surge voltage suppressor
Note)
length 300 mm S With surge voltage suppressor
H: Lead wire Z With light/surge voltage suppressor
length 600 mm R With surge voltage suppressor (Non-polar)
DC
U With light/surge voltage suppressor (Non-polar)
Without light/
surge voltage LO: MO: DO: YO: Note) There is no S option for AC mode, since a rectifier prevents
suppressor Without connector Without connector Without connector Without connector surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the connector,
CE DC DOZ, DOU, YOZ, YOU are not available.
compliant AC Note) — — —
∗ LN and MN types are with 2 sockets. Caution
∗ Refer to back page 2 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to back page 3 for details on the DIN (EN175301-803) terminal. When using the surge voltage suppressor type,
Note) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking residual voltage will remain. Refer to back page 5
compliant. for details.
1
Pilot Poppet Type
Body Ported/Single Unit Series VP300/500/700
Specifications
Low power consumption 1.5 W (DC)
Possible to use as either a Fluid Air
selector or divider valve Type of actuation N.C. or N.O. (Convertible)
Internal pilot Standard 0.2 to 0.7
Possible to change from Operating pressure range (MPa) High-pressure type 0.2 to 1.0
N.C. to N.O. Standard –100 kPa to 0.7
External pilot
• Refer to back page 6 for High-pressure type –100 kPa to 1.0
Operating pressure range (MPa)
changing the type of actuation. Pilot pressure range Same as operating pressure (Min. 0.2 MPa)
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Possible to use in vacuum Max. operating frequency (Hz) 5
applications Non-locking push type
Up to –100 kPa Manual override Push-turn locking slotted type
Push-turn locking lever type
Pilot exhaust type Individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
Series VP300 Impact/Vibration resistance (m/s2) Note) 300/50
Enclosure Dust-tight (IP65 for D, Y, T)
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
Series VP500
Solenoid Specifications
2
Series VP300/500/700
Flow Characteristics/Weight
Application Example
(1) Blow-off valve (2) Pressure release valve (3) Selector valve (4) Valve for vacuum
X port X port X port
X port
(Exhaust center)
Tank
External pilot
Construction
Body ported
i w r y t q ue
JIS symbol
Pilot type N.C. N.O.
(A) (A) 2(A)
2 2
Internal pilot
1 3 1 3
(P) (R) (P) (R)
(A)
2
External pilot
1 3
(P) (R)
1(P) 3(R)
X Strainer
Replacement Parts
No. Description Part no. Note
8 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 4. Built-in strainer
3
Pilot Poppet Type
Body Ported/Single Unit Series VP300/500/700
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.
V2 11 5 G Z
Light/surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor
Note)
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar)
V211
U With light/surge voltage suppressor (Non-polar)
Pilot valve assembly
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 5
for details.
Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to back page 2 when different length of
lead wire for L/M-type plug connector is required.
Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
4
Series VP300/500/700
21.5
NC
2A
1.3
3.4
0.8
Manual override
20.4 16
57.6 (1.6)
Approx. 300 96.1 (9)
(Lead wire length)
(Indicator light) Grommet (G)
DC without light/surge voltage suppressor
(Mounting groove
for M5 thread) 2 x ø3.2
(For mounting)
(5.4)
– +
(35)
35
25
Approx. 300
31
19.7
42.7
(17.5)
(45) 14
2.8
15 26.2
(54.5) (20.9)
(Dista
n ce be
tween
ports)
1/8, 1/4
4.5
97.3
26.5
NO
3R
1.1
ø3.8 20.4 16
PE port∗
56.4
42.7
Max. 10
20
73.7 76.9 [66.9]
53.7 Approx. 300 Pg9 Pg9
(Lead wire length)
105.3
102.4
102.9
88.9
94
(Indicator light)
26
NC
X
1.3
2A
3.5
4.5
Manual override
31 25.6
83.8 (1.6)
Approx. 300 122.3 (9)
(Lead wire length)
(Indicator light) Grommet (G)
(Mounting groove 2 x ø4.2 DC without light/surge voltage suppressor
for M5 thread) (For mounting)
(5.4)
31.5
45
45
(22.5)
40
22
16.3
(50)
4
23.5 39.6
(60)
(31.5)
(Dista
n ce be
tween
ports)
1/4, 3/8
1(P), 3(R) port
123.5
1P 3R
32
NO
7
2.5
ø3.8
30.7 25.6
PE port∗
83.6
45
85 89.2 [79.2]
Max. 10
Max. 10
120.2
115.1
(Indicator light)
NC
33
X
4.5
7.5
1.3
2A
Manual override
41 31
106.8 (2)
Approx. 300 145.3 (9)
(Lead wire length)
Grommet (G)
DC without light/surge voltage suppressor
2 x ø5.2
(Indicator light)
Approx. 300
– + 63
(63)
38.5
63
56.5
34.3
(31.5)
40
(Distan (43)
3/8, 1/2 ce betw
1(P), 3(R) port een po
rts)
146.5
1P 3R
NO
40
9
2.5
ø4
42 30.5
PE port∗
107.5
ø4.5 to ø7
(Lead wire
63
107.2 [97.2]
Max. 10
Max. 10
length)
103
40.3
94 97.2 [87.2]
74 Approx. 300 Pg9 Pg9
(Lead wire length)
154.5
151.6
152.1
143.2
138.1
(Indicator light)
Series VP300/500/700
Note) Only DIN and conduit terminal types
are available for AC mode.
How to Order Refer to the electrical entry for details.
Base mounted VP 3 4 4 5 G 1 A
Series
3 VP300 Pilot type Type of actuation
5 VP500 Nil Internal pilot A N.C. (Normally closed)
7 VP700 R External pilot B N.O. (Normally open)
DIN
Grommet
L-type plug M-type plug DIN
(EN175301-803)
Conduit Manual override
connector connector terminal terminal
terminal Nil: Non-locking D: Push-turn locking E: Push-turn locking
[IP65 compatible] [IP65 compatible] [IP65 compatible] push type slotted type lever type
Specifications
Low power consumption 1.5 W (DC)
Possible to use as either a Fluid Air
selector or divider valve Type of actuation N.C. or N.O. (Convertible)
Internal pilot Standard 0.2 to 0.7
Possible to change from Operating pressure range (MPa) High-pressure type 0.2 to 1.0
N.C. to N.O. Standard –100 kPa to 0.7
External pilot
• Refer to back page 6 for High-pressure type –100 kPa to 1.0
Operating pressure range (MPa)
changing the type of actuation. Pilot pressure range Same as operating pressure (Min. 0.2 MPa)
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Possible to use in vacuum Max. operating frequency (Hz) 5
applications Non-locking push type
Up to –100 kPa Manual override Push-turn locking slotted type
Push-turn locking lever type
Pilot exhaust type Individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
Series VP300 Impact/Vibration resistance (m/s2) Note) 300/50
Enclosure Dust-tight (IP65 for D, Y, T)
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
Series VP500 the right angles to the main valve and armature. (Values at the initial period)
Solenoid Specifications
9
Pilot Poppet Type
Base Mounted/Single Unit Series VP300/500/700
Flow Characteristics/Weight
Application Example
(1) Blow-off valve (2) Pressure release valve (3) Selector valve (4) Valve for vacuum
X port X port X port
X port
(Exhaust center)
Tank
External pilot
Construction
Base mounted i w r y t q ue
JIS symbol
Pilot type N.C. N.O.
(A) (A)
2 2
Internal
pilot
1 3 1 3
(P) (R) (P) (R)
(A) (A)
2 2
External o
2(A) 3(R)
pilot 1 3 1 3
(P) (R) (P) (R)
Strainer
!0
X X
X
Component Parts
No. Description Material Note 1(P)
1 Body Aluminum die-casted White
2 Adapter plate Resin Gray How to Order Sub-plate
3 End plate Resin White
4
5
Piston
Spool valve
Resin
Aluminum/HNBR VP 3 00 202 1
6 Retainer Resin Series
7 Spring Stainless steel
Thread type
3 VP344
Nil Rc
5 VP544
Replacement Parts F G
7 VP744
Part no. N NPT
No. Description Note
VP344 VP544 VP744 Caution Port size
T NPTF
8 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 11. Built-in strainer Tightening Torque Symbol VP344 VP544 VP744
9 Gasket VP300-217-1 VP500-217-1 VP700-217-1 HNBR of Mounting Screw 1 1/8 1/4 3/8
10 Sub-plate VP300-202-l VP500-202-l VP700-202-l Aluminum die-casted 2 1/4 3/8 1/2
M3: 0.8 N·m
Hexagon socket VP300-224-1 VP500-224-1 VP700-224-1 M4: 1.4 N·m
— For valve mounting
head bolt (1 pc.) (M3 x 36) (M4 x 46) (M5 x 66)
M5: 2.9 N·m
10
Series VP300/500/700
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.
V2 11 5 G Z
Light/surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor
Note)
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar)
U With light/surge voltage suppressor (Non-polar)
V211 Note) There is no S option for AC mode, since a rectifier prevents
Pilot valve assembly surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 5
for details.
Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to back page 2 when different length of
M DIN or Conduit type lead wire for L/M-type plug connector is
required.
DIN connector
(Refer to back page 3.) V2 12 5
Pressure specification Rated voltage
Nil Standard (0.7 MPa)
DC
K High-pressure type (1.0 MPa)
5 24 VDC
Coil specification 6 12 VDC
Nil Standard AC (50/60 Hz)
T With power saving circuit (DC only)
1 100 VAC
∗ T type is only available for DC mode. 2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
V212 7 240 VAC
Pilot valve assembly B 24 VAC
Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
11
Pilot Poppet Type
Base Mounted/Single Unit Series VP300/500/700
1/8, 1/4
19.5
2(A) port
12
43.7
18.5 2 x ø4.2 30 11.2
1/8, 1/4
(For mounting)
2A NO
3(R) port Grommet (G)
DC without light/surge voltage suppressor
35
43
– +
NC
1.3
3R
NC 1P
Manual override
Approx. 300
57.6 18.5
66.7
Approx. 300 96.1
(Lead wire length) 38
66.7
59
97.3
PE port∗
24
X
17.5
X
12
(ø3.8)
Max. 10
44 100.9 [90.9]
97.7
77.7 Approx. 300 Pg9 Pg9
(Lead wire length)
105.3
102.9
102.4
88.9
94
X
X
(Indicator light)
13.5
2(A) port
50.5
2 x ø5.2 47 17.6
23 (For mounting) 1/4, 3/8
2A NO
3(R) port Grommet (G)
DC without light/surge voltage suppressor
– +
42
52
NC
3R
NC 1P
Manual override
Approx. 300
12.6 13.5
83.8 73.5
23
Approx. 300 122.3 44.8
(Lead wire length)
(Indicator light)
73.5
123.5
PE port∗
28.5
X
19.5
(ø3.8) X
13.5
1/8 28.5
(External pilot port) 49.7
1/4, 3/8 57
1(P) port
∗ Refer to page 24 separately when piping to PE
port is required.
ø4.5 to ø7
(Lead wire
Max. 10
129.1
120.2
115.1
X
X
(Indicator light)
16
72.5
24 2 x ø6.2 67 18 3/8, 1/2
(For mounting) 3(R) port
2A NO Grommet (G)
DC without light/surge voltage
53 suppressor
66
NC
– +
3R
Manual override NC 1P
Approx. 300
(Indicator light) 11.5 16
106.8
24 95.5
Approx. 300 145.3
66.8
(Lead wire length)
95.5
146.5
X
PE port∗
32.5
21
16
(ø4) X
1/8 40
(External pilot port) 64
3/8, 1/2 80
1(P) port
ø4.5 to ø7 ø4.5 to ø7
95.5
Max. 10
Max. 10
143.2
X
X
138.1
X
(Indicator light)
Series VP300/500/700
How to Order Manifold
···
20 20 stations
···
20 20 stations
15
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42 Series VP300/500/700
Note) Only DIN and conduit
terminal types are
available for AC mode.
Refer to the electrical
How to Order Valve (With a gasket and two mounting bolts) entry for details.
VP 3 4 4 5 G 1 A
Series Type of actuation
3 VP300 A N.C. (Normally closed)
5 VP500 B N.O. (Normally open)
7 VP700
Manual override
Pilot type Nil: Non-locking D: Push-turn locking E: Push-turn locking
push type slotted type lever type
Nil Internal pilot
R External pilot
Pressure specification
Nil Standard (0.7 MPa)
K High-pressure type (1.0 MPa)
Coil specification
Nil Standard Light/surge voltage suppressor DC AC
T With power saving circuit (DC only) Nil Without light/surge voltage suppressor
Note)
Note) Be sure to select the power saving circuit S With surge voltage suppressor
type when it is continuously energized for a Z With light/surge voltage suppressor
long time. (Refer to back page 5 for details.) R With surge voltage suppressor (Non-polar)
∗ T type is only available for DC mode. When T is
selected, only Z type of light/surge voltage sup-
U With light/surge voltage suppressor (Non-polar)
pressor is available. Note) There is no S option for AC mode, since a rectifier prevents
(Note that when the electrical entry of DIN termi- surge voltage generation.
nal type without connector is selected, only DOS ∗ In the DIN terminal type, since a light is installed in the connector,
and YOS are available.) DOZ, DOU, YOZ, YOU are not available.
LN: MN:
Without lead wire Without lead wire
G: Lead wire
length 300 mm
H: Lead wire
length 600 mm
DC
Without light/
surge voltage LO: MO: DO: YO:
suppressor Without connector Without connector Without connector Without connector
CE DC
compliant AC Note) — — —
∗ LN and MN types are with 2 sockets.
∗ Refer to back page 2 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to back page 3 for details on the DIN (EN175301-803) terminal.
Note) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking
compliant.
16
Series VP300/500/700
Manifold Option
VV3P5-42-053-03
VP344-5GZ1-A
VP300-25-1A
Us
ide
Sta
tio VV3P3-41-051-02 ···················· 1 set (Type 41, 5-station manifold base part no.)
ns
∗ VP300-25-1A ······················· 1 set (Blanking plate assembly part no.)
∗ VP344-5GZ1-A ···················· 2 sets (N.C. type part no.)
3 ∗ VP344-5GZ1-B ···················· 2 sets (N.O. type part no.)
2 The asterisk denotes the symbol for assembly.
1 Prefix it to the part nos. of the solenoid valve, etc.
Ds • Indicate the valves to be attached below the manifold part number, in order starting
ide
Port size: 1/4 from station 1 as shown in the drawing.
17
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42 Series VP300/500/700
Series VP300/Dimensions
Type 41/Common exhaust: VV3P3-41l- Stations 1-02
Grommet (G)
(Lead wire length)
Approx. 300
M5 x 0.8
Common external pilot port
(External pilot specification: R)
N.O. N.C.
72.5
30.5
Manual override 24
2 x ø6.5
17.5
(For mounting) 13.5
96.1
NC
26.2
57.6
3R
57.6
27
50
26.2
1P
96.1
NO
1/4
1(P), 3(R) port
(Pitch) PE port∗
P = 27.5 28 (ø3.8)
L2 7.5
∗ Refer to page 24 separately when piping to
L1 PE port is required.
Grommet (G)
DC without light/surge voltage
(Station n) (Station 1)
suppressor
(Indicator light)
– +
3R
1P
80.2
97.3
57.2
50.1
11
37.5
2A 2A
1/4
2(A) port (Pitch)
P = 27.5 28
51.5
(Lead wire length)
80.2
Approx. 300
(Indicator light)
3R
3R
3R
3R
1P
1P
1P
1P
88.9
102.4
102.9
105.3
94
Max. 10
length) 120.2
80.2 124.4 [114.4]
Applicable cable O.D.
Approx. 300
Series VP300/Dimensions
Type 42/Individual exhaust: VV3P3-42l- Stations 3-02
Grommet (G) (Pitch)
P = 27.5 28
1/4
3(R) port
18.5
3R 3R
(Lead wire length)
– +
Approx. 300
M5 x 0.8
Common external pilot port
(External pilot specification: R)
N.O. N.C.
72.5
30.5
Manual override
2 x ø6.5 24
17.5
(For mounting)
96.1
NC
26.2
13.5
57.6
57.6
50
26.2
1P
96.1
NO
1/4
1(P) port Grommet (G)
(Pitch) PE port∗ DC without light/surge voltage
P = 27.5 28 suppressor
(ø3.8)
L2 7.5
L1 ∗ Refer to page 24 separately when piping to
PE port is required.
(Station n) (Station 1)
(Indicator light)
1P
97.3
– +
80.2
57.2
50.1
11
37.5
2A 2A
51.5
(Lead wire length)
1/4 80.2
(Pitch)
2(A) port
P = 27.5 28
Approx. 300
1P
1P
1P
88.9
102.4
102.9
105.3
94
Max. 10
(Lead wire length)
length) 120.2
80.2 124.4 [114.4]
Applicable cable O.D.
Approx. 300
ø4.5 to ø7
Applicable cable O.D.
ø4.5 to ø7
Series VP500/Dimensions
Type 41/Common exhaust: VV3P5-41l- Stations 1-03
Grommet (G)
(Lead wire length)
Approx. 300
M5 x 0.8
N.O. N.C. Common external pilot port
(External pilot specification: R)
Manual override
42
2 x ø7.2
30
23.5
(For mounting)
20.5
NC
122.3
41.1
83.8
3R
83.8
33
60
1P
122.3
41.1
NO
3/8
1(P), 3(R) port
(Pitch) PE port∗
P = 33 31 (ø3.8)
L2 7.5
∗ Refer to page 24 separately when piping to
L1 PE port is required. Grommet (G)
DC without light/surge voltage
(Station n) (Station 1) suppressor
(Indicator light)
– +
3R
92.5
69.5
1P
61.3
123.5
47.5
2A 2A
3/8 (Pitch)
13.5
2(A) port P = 33 31
63.8
(Lead wire length)
92.5
Approx. 300
(Indicator light)
3R
3R
3R
3R
115.1
120.2
1P
1P
1P
1P
129.1
128.6
131.5
126.7 [116.7]
Max. 10
(Lead wire length)
length) 132.5
92.5 136.7 [126.7]
Applicable cable O.D.
Approx. 300
Series VP500/Dimensions
Type 42/Individual exhaust: VV3P5-42l- Stations 3-03
Grommet (G)
(Pitch)
3/8 P = 33 31
3(R) port
28.5
3R 3R
(Lead wire length)
– +
Approx. 300
M5 x 0.8
N.O. N.C.
Common external pilot port
Manual override (External pilot specification: R)
2 x ø7.2 42
(For mounting) 30
23.5
NC
122.3
41.1
16.5
83.8
83.8
60
1P
122.3
41.1
NO
3/8
1(P) port Grommet (G)
(Pitch) DC without light/surge voltage
P = 33 31 PE port∗ suppressor
L2 7.5 (ø3.8)
L1
∗ Refer to page 24 separately when piping to
PE port is required.
(Station n) (Station 1)
(Indicator light)
1P
123.5
– +
92.5
69.5
61.3
47.5
2A 2A
1P
1P
1P
120.2
129.1
128.6
131.5
length) 132.5
92.5 136.7 [126.7]
Applicable cable O.D.
Approx. 300
Series VP700/Dimensions
Type 41/Common exhaust: VV3P7-41l- Stations 1-04
Grommet (G)
(Lead wire length)
Approx. 300
1/8
Common external pilot port
(External pilot specification: R)
N.O. N.C.
Manual override
55
2 x ø8.5 40
(For mounting) 24
NC
51.5
145.3
32
106.8
106.8
3R
48
86
145.3
1P
51.5
NO
1/2
1(P), 3(R) port
(Pitch)
P = 41 37
PE port∗
L2 8
(ø4)
L1
∗ Refer to page 24 separately when piping to
PE port is required.
Grommet (G)
(Station n) (Station 1) DC without light/surge voltage
suppressor
(Indicator light)
– +
126
103
3R
78.2
146.5
1P
2A 2A
63
19
1/2 (Pitch)
2(A) port P = 41 37
97.3
(Lead wire length)
126
Approx. 300
3R
3R
3R
138.1
143.2
152.1
151.6
1P
1P
1P
1P
154.5
160.2 [150.2]
(Lead wire length)
Max. 10
166
126 length)
170.2 [160.2]
Applicable cable O.D.
Approx. 300
Series VP700/Dimensions
Type 42/Individual exhaust: VV3P7-42l- Stations 3-04
Grommet (G)
(Pitch)
1/2 P = 41 37
3(R) port
34
3R 3R
(Lead wire length)
1/8
– +
Approx. 300
24 32
NC
86
51.5
145.3
1P
106.8
106.8
145.3
51.5
1/2
NO 1(P) port
PE port∗
Grommet (G)
(Pitch) DC without light/surge voltage
(ø4)
P = 41 37
suppressor
L2 8 ∗ Refer to page 24 separately when piping to
L1 PE port is required.
(Station n) (Station 1)
(Indicator light)
146.5
– +
1P
126
103
78.2
2A 2A
63
19
97.3
(Lead wire length)
1/2 (Pitch)
2(A) port P = 41 126
37
Approx. 300
(Indicator light)
138.1
143.2
152.1
151.6
1P
1P
1P
1P
154.5
160.2 [150.2]
Max. 10
2 Body Ported Interchangeable Specification with the Previous Valve Mounting Hole Pitch Type
The mounting hole has been changed to the long type in order to provide interchangeability with the previous VP300/500 series.
VP 35 42 1 X505
VP342 VP542
21.5
28
15
22
24
3 Port/Air Operated Valve
Body Ported/Single Unit
Series VPA300/500/700
How to Order
VPA 3 4 2 1 01 A
Series
Series VPA300 3 VPA300
5 VPA500
7 VPA700 Made to Order
Nil —
Valve option Interchangeable
Nil Standard specification with the
V For vacuum X505 previous valve
mounting hole pitch
Series VPA500 Port size type (Refer to page
Symbol Port size VPA300 VPA500 VPA700 40).
01 1/8
02 1/4 Bracket
03 3/8 Nil Without bracket
04 1/2 F With bracket
Thread type
Nil Rc
Type of actuation
F G A N.C. (Normally closed)
Series VPA700 N NPT B N.O. (Normally open)
T NPTF
Specifications
Fluid Air
Type of actuation N.C. or N.O. (Convertible)
Standard 0.2 to 1.0
Operating pressure range (MPa)
For vacuum –100 kPa to 0.2
Pilot pressure (MPa) 0.2 to 1.0 (Equivalent to the operating pressure or more)
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 300/50
Note) Impact resistance: No malfunction to axis and right angle directions of main valve, each one time
when pilot signal ON and OFF. (Values at the initial period)
Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle
direction of main valve, each one time when pilot signal ON and OFF. (Values at
the initial period)
Flow Characteristics/Weight
1 ↔ 2 (P ↔ A) 2 ↔ 3 (A ↔ R)
Model Port size Weight (g) Note)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
1/8 3.5 0.26 0.8 3.6 0.26 0.9 118
VPA342
1/4 4.2 0.22 1.0 4.2 0.23 1.0 114
1/4 7.9 0.21 1.8 7.2 0.27 1.8 237
VPA542
3/8 8.9 0.16 2.2 8.9 0.20 2.1 229
3/8 11.9 0.21 2.7 11.8 0.20 2.7 501
VPA742
1/2 15.1 0.21 3.6 15.3 0.22 3.7 484
Note) Values without brackets
Caution
• Refer to back page 6 for
Refer to back cover for Safety Instructions, “Handling Precautions for changing the type of
actuation.
SMC Products” (M-E03-3) for Common Precautions.
25
Air Operated Valve
Body Ported/Single Unit Series VPA300/500/700
Construction
Standard
r w y t q u e
JIS symbol
12 2(A)
N.C. N.O.
(A) (A)
2 2
12 12
Standard
1 3 1 3
(P) (R) (P) (R)
(A)
2
For 12
vacuum
1 3
(P) (R)
1(P) 3(R)
For vacuum
r w y t q u e
2(A)
12
1(P) 3(R)
26
Series VPA300/500/700
2 x ø3.2
(For mounting) 26.2
1/8
12 (PA) port
21.5
NC
12
2A
3.4
20.4 16
58.2 (1.6)
65.2 (9)
12
(35)
36
35
31
25
(17.5)
16.5
2.8
(45) (20.9) 15 26.2
(Dista
(54.5) n
ce be
tween
1/8, 1/4 ports)
4.5
1(P), 3(R) port
1P
26.5
NO
3
3R
M5 x 0.8
20.4 16
(Breathing hole)
53.7
02l B (-F)
For vacuum/VPA342V-1- 01 A
1/8, 1/4
2(A) port
2 x ø3.2 26.2
(For mounting)
21.5
NC
2A
3.4
20.4 16 (1.6)
65.2 (9)
12
(35)
36
35
31
25
16.5
(17.5)
2.8
3R
M5 x 0.8
20.4 16
(Breathing hole)
53.7
27
Air Operated Valve
Body Ported/Single Unit Series VPA300/500/700
26
NC
12
2A
3.5
31 25.6
83 (1.6)
91 (9)
12
(45)
46
31.5
45
40
22.5
4
(50)
23.5 39.6
(60)
1/4, 3/8 (31.5)
(Distan
1(P), 3(R) port ce betw
een po
rts)
1P 3R
32
3
NO
M5 x 0.8
30.7 25.6
(Breathing hole)
76.8
03l B (-F)
For vacuum/VPA542V-1- 02 A
1/4, 3/8
2(A) port
41.1
2 x ø4.2
(For mounting)
26
NC
2A
3.5
31 25.6 (1.6)
91 (9)
12
(45)
46
31.5
45
40
22.5
(50)
23.5 39.6
(60)
1/4, 3/8 (31.5)
(Distan
1(P), 3(R) port ce betw
een po
rts)
1P 3R
32
3
NO
M5 x 0.8
30.7 25.6
(Breathing hole)
76.8
28
Series VPA300/500/700
NC
33
12
4.5
2A
41 31
107.1 (2)
115.1 (9)
(1/8) 2 x ø5.2
(Mounting groove for M6 thread) 12(PA) port (For mounting)
(6.4)
12
(63)
64
38.5
63
56.5
31.5
(60) 31 51.5
9.4
(74) (43)
3/8, 1/2 (Distan
ce betw
1(P), 3(R) port een po
rts)
1P 3R
NO
40
3
M5 x 0.8
42 30.5 9
(Breathing hole)
100.8
04l B (-F)
For vacuum/VPA742V-1- 03 A
3/8, 1/2
2(A) port
51.5
2 x ø5.2
(For mounting)
NC
33
4.5
2A
41 31 (2)
115.1 (9)
1/8 2 x ø5.2
(Mounting groove for M6 thread) 12(PA) port (For mounting)
(6.4)
12
(63)
64
38.5
63
56.5
31.5
(60) 31 51.5
9.4
1P 3R
NO
40
3
M5 x 0.8
42 30.5
(Breathing hole)
100.8
29
3 Port/Air Operated Valve
Base Mounted/Single Unit
Series VPA300/500/700
How to Order
VPA 3 4 4 1 01 A
Series
Series VPA300 Type of actuation
3 VPA300
5 VPA500
A N.C. (Normally closed)
7 VPA700
B N.O. (Normally open)
Fluid Air
Type of actuation N.C. or N.O. (Convertible)
Standard 0.2 to 1.0
Operating pressure range (MPa)
For vacuum –100 kPa to 0.2
Pilot pressure (MPa) 0.2 to 1.0 (Equivalent to the operating pressure or more)
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 300/50
Note) Impact resistance: No malfunction to axis and right angle directions of main valve, each one time
when pilot signal ON and OFF. (Values at the initial period)
Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle
direction of main valve, each one time when pilot signal ON and OFF. (Values at
the initial period)
Flow Characteristics/Weight
1 ↔ 2 (P ↔ A) 2 ↔ 3 (A ↔ R)
Model Port size Weight (g) Note)
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
1/8 3.6 0.22 0.8 3.5 0.24 0.8 185 (118)
VPA344
1/4 3.9 0.22 0.9 3.8 0.14 0.9 180 (118)
1/4 7.5 0.16 1.7 7.3 0.20 1.7 358 (233)
VPA544
3/8 8.8 0.07 2.0 8.8 0.13 2.0 350 (233)
3/8 12.9 0.10 2.9 13.3 0.24 3.1 693 (476)
VPA744
1/2 14.7 0.05 3.3 15.0 0.17 3.4 675 (476)
Note) ( ): Values without sub-plate
Caution
• Refer to back page 6 for
Refer to back cover for Safety Instructions, “Handling Precautions for changing the type of
actuation.
SMC Products” (M-E03-3) for Common Precautions.
30
Series VPA300/500/700
Construction
Standard
r w y t q u e
JIS symbol
N.C. N.O.
(A) (A)
2 2
12 12
Standard
1 3 1 3
(P) (R) (P) (R)
i
(A) (A)
2 2
2(A) 3(R)
For 12 12
o
vacuum
1 3 1 3
(P) (R) (P) (R)
1(P)
For vacuum
r w y t q u e
i
2(A) 3(R)
o
X
Component Parts
No. Description Material Note 1(P)
1 Body Aluminum die-casted White
2 Adapter plate Aluminum die-casted Gray
3 End plate Resin White
4 Piston Resin
5 Spool valve Aluminum/HNBR
6 Retainer Resin
7 Spring Stainless steel
Replacement Parts
Part no. How to Order Sub-plate
No. Description Note
VP344 VP544 VP744
8 Gasket VP300-217-1 VP500-217-1 VP700-217-1 HNBR
9 Sub-plate VP300-202-l VP500-202-l VP700-202-l Aluminum die-casted VP 3 00 202 1
Hexagon socket VP300-224-1 VP500-224-1 VP700-224-1
— For valve mounting Series
head bolt (1 pc.) (M3 x 36) (M4 x 46) (M5 x 66) Thread type
3 VPA344
Nil Rc
5 VPA544
Caution 7 VPA744
F G
N NPT
Tightening Torque T NPTF
of Mounting Screw Port size
Symbol VPA344 VPA544 VPA744
M3: 0.8 N·m
1 1/8 1/4 3/8
M4: 1.4 N·m
2 1/4 3/8 1/2
M5: 2.9 N·m
31
Air Operated Valve
Base Mounted/Single Unit Series VPA300/500/700
12
40.5 2 x ø4.2
(For mounting) 11.2
18.5 30 1/8, 1/4
1/8 3(R) port
12(PA) port
2A NO
35
43
NC
12
12
3R
NC 1P
(1/8)
6.7 12
12(PA) port
58.2 18.5
65.2
60
59
24
X
12
M5 x 0.8
19.5
(Breathing hole)
39
1/8, 1/4
1(P) port
02l B
For vacuum/VPA344V-1- 01 A
1/8, 1/4
19.5
2(A) port
12
40.5
2 x ø4.2
18.5 30 11.2 1/8, 1/4
(For mounting)
3(R) port
2A NO
35
43
NC
12
3R
NC 1P
1/8
6.7 12
12(PA) port
65.2 18.5
60
59
24
X
12
M5 x 0.8 19.5
(Breathing hole)
39
1/8, 1/4
1(P) port
32
Series VPA300/500/700
13.5
28.5
2(A) port
51
2 x ø5.2
23 (For mounting) 47 17.6 1/4, 3/8
1/8 3(R) port
2A NO
12(PA) port
42
52
NC
12
12
3R
NC 1P
(1/8)
12.6 13.5
12(PA) port 83
23
91
74.5
73.5
28.5
X
13.5
M5 x 0.8
(Breathing hole) 28.5
57
1/4, 3/8
1(P) port
03 l B
For vacuum/VPA544V-1-02 A
1/4, 3/8
13.5
28.5
2(A) port
51
2 x ø5.2
23 (For mounting) 47 17.6 1/4, 3/8
3(R) port
2A NO
42
52
NC
12
3R
NC 1P
1/8
12.6 13.5
12(PA) port 91
23
74.5
73.5
28.5
X
13.5
M5 x 0.8
(Breathing hole) 28.5
57
1/4, 3/8
1(P) port
33
Air Operated Valve
Base Mounted/Single Unit Series VPA300/500/700
16
64
24 2 x ø6.2 67 18 3/8, 1/2
(For mounting) 3(R) port
1/8 2A NO
12(PA) port
NC
53
66
12
12
3R
NC 1P
(1/8) 11.5
107.1 16
12(PA) port
115.1 24
96.5
95.5
32.5
16
40
3/8, 1/2
1(P) port 80
04l B
For vacuum/VPA744V-1- 03 A 3/8, 1/2 40
2(A) port
16
64
53
66
12
3R
NC 1P
1/8 11.5
115.1 16
12(PA) port
24
96.5
95.5
32.5
16
40
3/8, 1/2
1(P) port 80
34
3 Port/Air Operated Valve Manifold
Common Exhaust Type 41 /
Individual Exhaust Type 42
Series VPA300/500/700
How to Order Manifold
Port size
Stations Symbol Port size Applicable series
02 2 stations 02 1/4 VPA300
···
···
03 3/8 VPA500
20 20 stations 04 1/2 VPA700
Port size
Stations Symbol Port size Applicable series
02 2 stations 02 1/4 VPA300
···
···
03 3/8 VPA500
20 20 stations 04 1/2 VPA700
Manifold Option
35
Air Operated Valve
Common Exhaust Type 41 /Individual Exhaust Type 42 Series VPA300/500/700
VPA 3 4 4 1 A
Series Type of actuation
3 VPA300 A N.C. (Normally closed)
5 VPA500 B N.O. (Normally open)
7 VPA700
Thread type
Body option Nil RC
Nil Standard F G
V For vacuum N NPT
T NPTF
Manifold Specifications
Piping specifications
Manifold base
Applicable Applicable
Series Base model 1P (SUP) 3R (EXH) Weight: W [g]
Port size valve stations Note)
port type port type Stations: n
VV3PA3-41 Common
VPA300 1/4 VPA344 2 to 20 stations W = 110n + 90
VV3PA3-42 Individual
VV3PA5-41 Common
VPA500 Common 3/8 VPA544 2 to 20 stations W = 190n + 150
VV3PA5-42 Individual
VV3PA7-41 Common
VPA700 1/2 VPA744 2 to 20 stations W = 410n + 380
VV3PA7-42 Individual
Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or more.
VPA344-1-A
VP300-25-1A
Us
ide
Sta
tio VV3PA3-41-051-02 ················· 1 set (Type 41, 5-station manifold base part no.)
ns
∗ VP300-25-1A ······················· 1 set (Blanking plate assembly part no.)
∗ VPA344-1-A ························ 2 sets (N.C. type part no.)
3
∗ VPA344-1-B ························ 2 sets (N.O. type part no.)
2
The asterisk denotes the symbol for assembly.
1 Prefix it to the part nos. of the valve, etc.
Ds
ide • Indicate the valves to be attached below the manifold part number, in order starting
Port size: 1/4
from station 1 as shown in the drawing.
36
Series VPA300/500/700
Series VPA300/Dimensions
Type 41/Common exhaust: VV3PA3-41- Stations 1-02
72.5
N.O. N.C. 2 x ø6.5 24
(For mounting) 13.5
12 NC
26.2
65.2
58.2
3R
58.2
27
50
65.2
1P
26.2
NO 12
1/8 1/4
12(PA) port (Pitch) 1(P), 3(R) port
P = 27.5 28
M5 x 0.8
L2 7.5
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12(PA) port
12
73.5
50.1
54
37.5
11
2A 2A
1/4 (Pitch)
2(A) port P = 27.5 28
3R 3R
12
13.5
65.2
58.2
50
58.2
65.2
1P
26.2
NO 12
1/8 1/4
12(PA) port (Pitch) 1(P) port
P = 27.5 28
M5 x 0.8
L2 7.5
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12(PA) port
12
73.5
50.1
54
11
37.5
2A 2A
1/4 (Pitch)
2(A) port P = 27.5 28
Series VPA500/Dimensions
Type 41/Common exhaust: VV3PA5-41- Stations 1-03 92.5
2 x ø7.2 30
N.O. N.C.
(For mounting) 20.5
NC
12
41.1
3R
91
83
33
60
83
91
1P
41.1
12
NO
3/8
1/8
(Pitch) 1(P), 3(R) port
12(PA) port
P = 33 31
L2 7.5 M5 x 0.8
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12(PA) port 12
93.5
70
61.3
13.5
47.5
2A 2A
3/8 (Pitch)
2(A) port P = 33 31
3R 3R
12
2 x ø7.2 92.5
N.O. N.C. 30
(For mounting)
NC
12
41.1
16.5
91
83
60
83
91
1P
41.1
12
NO
3/8
1/8
(Pitch) 1(P) port
12(PA) port
P = 33 31
L2 7.5 M5 x 0.8
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12(PA) port 12
93.5
70
61.3
13.5
47.5
2A 2A
3/8 (Pitch)
2(A) port P = 33 31
Series VPA700/Dimensions
Type 41/Common exhaust: VV3PA7-41- Stations 1-04 127
2 x ø8.5 40
N.O. N.C.
(For mounting) 24
12 NC
51.5
115.1
107.1
3R
115.1
48
86
107.1
1P
51.5
NO 12
1/2
1/8
(Pitch) 1(P), 3(R) port
12(PA) port P = 41 37
M5 x 0.8
L2 8
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12
12(PA) port
127
94.5
2A 2A 78.2
63
19
1/2 (Pitch)
2(A) port P = 41 37
3R 3R
12
2 x ø8.5 127
N.O. N.C. (For mounting)
40
12 NC
51.5
115.1
107.1
107.1
115.1
86
24
1P
51.5
NO 12
1/2
1/8
(Pitch) 1(P) port
12(PA) port P = 41 37
M5 x 0.8
L2 8
(Breathing hole)
L1
(Station n) (Station 1)
1/8
12(PA) port 12
127
94.5
78.2
2A 2A
63
19
1/2 (Pitch)
2(A) port P = 41 37
1 Body Ported Interchangeable Specification with the Previous Valve Mounting Hole Pitch Type
The mounting hole has been changed to the long type in order to provide interchangeability with the previous VPA300/500 series.
VPA 35 42 1 X505
VPA342 VPA542
21.5
28
15
22
40
Series VP
Specific Product Precautions 1
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
Without an electric signal for the solenoid valve the 1. Attaching and detaching connectors
manual override is used for switching the main valve. • To attach a connector, hold the lever and connector unit
Connected actuator is started by manual operation. between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
Use the manual override after confirming that there is groove and locks.
no danger. • To detach a connector, remove the pawl from the groove by
L Non-locking push type pushing the lever downward with your thumb, and pull the
connector straight out.
Push down on the manual
Cover
override button with a small
screwdriver until it stops. Groove
Release the screwdriver Pin Lever
and the manual override DC polarity indication
Cover
will return.
Groove
Pin Connector
L Push-turn locking slotted type
Socket
Socket Connector
Caution Lead wire
When locking the manual override with the push-turn locking type
(D or E type), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the Hook Not in use
Insert a socket into square hole
manual override and other trouble such as air leakage, etc.
Do not apply excessive torque when turning the locking type
manual override. (0.1 N·m)
Back page 1
Series VP
Specific Product Precautions 2
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Ground nut
Set screw
Tightening torque
2.5 to 3.75 N·m Tightening torque
0.5 to 0.6 N·m
Washer Housing
Grommet
(Rubber)
Terminal block
Terminal screw
3 locations
–
+ Tightening torque
(Location for 0.4 to 0.5 N·m
light mounting)
(Polarity indication)
(Voltage symbol)
Back page 2
Series VP
Specific Product Precautions 3
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
LED R NL R
LED: Light emitting diode, R: Resistor NL: Neon bulb R: Resistor
LED R D
LED: Light emitting diode
D: Protective diode
R: Resistor
Back page 3
Series VP
Specific Product Precautions 4
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Caution Caution
Especially when a resistor and a switching element are used <DC>
in parallel or C-R device (surge voltage suppressor) is used
L Polar type
for the protection of the switching device, note that leakage
voltage will be increased by passing leakage voltage through With surge voltage suppressor (lS) Polarity protection diode
the resistor and C-R device. Therefore, suppressor residual
leakage voltage should be as follows. Red (+)
Coil
AC coil LED
Black (–)
8% or less of the rated voltage
P DIN or Conduit terminal
With light/surge voltage suppressor (lZ) Polarity protection diode
Continuous Duty Diode
(+)
LED
Caution Coil
Varistor Coil
(+) (–)
(+) (–)
For DIN type, installed
in the connector
Applied voltage
Residual Voltage
24 V DC
Surge voltage suppressor AC
24 12
S, Z Approx. 1 V Approx. 1 V
0V R, U Approx. 47 V Approx. 32 V —
Surge voltage
Red (+) 0V
Coil
PWM circuit
sol.2: De-
R
energized Surge –60 V
voltage
24 V
0V
LED
Black (–) Large capacity
R
load: Energized –60 V
<AC> Relay
Power supply circuit breaker
There is no S option, since a rectifier prevents surge voltage
generation. 24 VDC
Figure 1. Surge intrusion circuit example (NPN outlet example) (24 VDC)
P Grommet or L/M-type plug connector
With light/surge voltage suppressor (lZ) Output circuit
Surge voltage
(~) 24 V
0V
sol.1: Energized –2 V or less
Varistor LED Coil R
Internal circuit
Surge voltage
(~) 0V
sol.2: De- –2 V or less
R energized Surge voltage
P DIN or Conduit terminal 24 V
0V
With light/surge voltage suppressor (lZ) Large capacity –2 V or less
R
load: Energized
(~) Diode Countermeasure parts
Note)
Neon bulb – (Anode) + (Cathode)
Varistor Coil
Relay
Power supply circuit breaker
(~)
For DIN type, installed in the connector
24 VDC
Note) LED for 24 VAC. Figure 2. Surge intrusion circuit example (NPN outlet example) (24 VDC)
Back page 5
Series VP
Specific Product Precautions 6
Be sure to read before handling.
Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning Caution
When changing the actuation or restarting the valve When fittings are used, they may interfere with one another de-
pending on their types and sizes. Therefore, the dimensions of
after the change, make sure that safety is fully as- the fittings to be used should first be confirmed in their respective
sured and pay great attention. catalogs.
Fittings whose compliance with the VP series is already con-
Example: Changing from N.C. to N.O. firmed are stated below. If the fitting within the applicable range is
1) Base mounted selected, there will not be any interference.
Applicable Fittings: Series KQ2H, KQ2S
<N.C.> <N.O.>
N.C. Piping Port Applicable tubing O.D.
Series
port size ø3.2 ø4 ø6 ø8 ø10 ø12 ø16
1P, 2A, 3R 1/8, 1/4
VP(A)300
X M5
1P, 2A, 3R 1/4, 3/8
VP(A)500
N.O. X 1/8
1P, 2A, 3R 3/8, 1/2
1. Remove the body from the sub-plate and reset the “ H ” mark VP(A)700
X 1/8
on the body corresponding to the “N.O.” mark on the sub-plate
as shown in the figure above. VV3P(A)3 1P, 2A, 3R 1/4
2. Remove the end plate from the body and rotate the end plate Manifold base X M5
by 180° so that the “N.O.” mark on the end plate is at the top VV3P(A)5 1P, 2A, 3R 3/8
of the valve. Manifold base X M5
∗ It is not necessary to change the piping when this is done.
VV3P(A)7 1P, 2A, 3R 1/2
2) Body ported Manifold base X 1/8
<N.C.> <N.O.>
N.C. N.O.
P Remove the end plate from the body and rotate the end plate
by 180° to correspond the “N.O.” mark on the end plate to the
top of the valve.
∗ Piping should be arranged as follows.
Port
Type 1P 2A 3R
of actuation
N.C. Inlet side Outlet side Exhaust side
N.O. Exhaust side Outlet side Inlet side
Back page 6
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or
moderate injury.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots - Safety.
Warning: risk which, if not avoided, could result in death or
serious injury.
etc.
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its specifications. The product herein described is basically provided for peaceful use in
Since the product specified here is used under various operating conditions, its manufacturing industries.
compatibility with specific equipment must be decided by the person who designs If considering using the product in other industries, consult SMC beforehand and
the equipment or decides its specifications based on necessary analysis and test
exchange specifications or a contract if necessary.
results. The expected performance and safety assurance of the equipment will be
If anything is unclear, contact your nearest sales branch.
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the Limited warranty and Disclaimer/
equipment.
2. Only personnel with appropriate training should operate
Compliance Requirements
machinery and equipment. The product used is subject to the following “Limited warranty and Disclaimer”
The product specified here may become unsafe if handled incorrectly. The and “Compliance Requirements”.
assembly, operation and maintenance of machines or equipment including our Read and accept them before using the product.
products must be performed by an operator who is appropriately trained and
experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and
machinery/equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5 years after
1. The inspection and maintenance of machinery/equipment should only be the product is delivered.∗2)
performed after measures to prevent falling or runaway of the driven objects Also, the product may have specified durability, running distance or
have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source 2. For any failure or damage reported within the warranty period which is clearly our
is cut, and read and understand the specific product precautions of all relevant responsibility, a replacement product or necessary parts will be provided.
products carefully. This limited warranty applies only to our product independently, and not to any
3. Before machinery/equipment is restarted, take measures to prevent
other damage incurred due to the failure of the product.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety 3. Prior to using SMC products, please read and understand the warranty terms
measures if the product is to be used in any of the following and disclaimers noted in the specified catalog for the particular products.
conditions. ∗2) Vacuum pads are excluded from this 1 year warranty.
1. Conditions and environments outside of the given specifications, or use A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
outdoors or in a place exposed to direct sunlight. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
or failure due to the deterioration of rubber material are not covered by the limited warranty.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency Compliance Requirements
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the 1. The use of SMC products with production equipment for the manufacture of
product catalog. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis. 2. The exports of SMC products or technology from one country to another are
4. Use in an interlock circuit, which requires the provision of double interlock for governed by the relevant security laws and regulations of the countries involved
possible failure by using a mechanical protective function, and periodical in the transaction. Prior to the shipment of a SMC product to another country,
checks to confirm proper operation. assure that all local rules governing that export are known and followed.
Revision history
Edition B ∗ Addition of 24 VAC to Rated voltage for Series VP300/500/700.
∗ Addition of -X505 to Made to Order for Series VP300/500.
∗ Addition of -X505 to Made to Order for Series VPA300/500. OZ
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
Series
Rubber Seal
VP3145/3165/3185
[Option]
Series VP3145/3165/3185
Solenoid Specifications
Grommet (G), Conduit terminal (T)
Standard
DIN terminal (D)
Conduit terminal with indicator light (TL),
Conduit terminal with surge voltage suppressor (TS),
Electrical entry Conduit terminal with light/surge voltage suppressor (TZ),
Option
Main pressure (MPa) DIN terminal with indicator light (DL),
DIN terminal with surge voltage suppressor (DS),
DIN terminal with light/surge voltage suppressor (DZ)
AC ( 50 60 Hz) 100, 200, 110 ∗, 220 ∗, 240 ∗
Coil rated voltage (V)
DC 12 ∗, 24
Allowable voltage fluctuation –15 to +10% of rated voltage
Inrush 73 VA (50 Hz), 58 VA (60 Hz)
Apparent power Note) AC
Holding 28 VA (50 Hz), 17 VA (60 Hz)
Power consumption Note) DC 12 W
∗ Option
Note) At rated voltage
Flow Characteristics/Mass
Port size
Flow characteristics Mass ∗
1 → 2 (IN → OUT) 2 → 3 (OUT → EXH) (kg)
Valve model
C C
1(IN), 2(OUT) 3(EXH) b Cv b Cv Grommet
[dm3/(s·bar)] [dm3/(s·bar)]
38 19 0.43 5.5 18 0.47 5.4
VP3145 12 34 23 0.32 6.2 21 0.39 5.8 1.5
34 28 0.36 7.6 26 0.35 7.0
1496
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1497
Construction/Internal Pilot
As in the figure below, this pilot-operated solenoid valve consists of a
compact 3 port solenoid valve as the pilot valve and a large 3 port valve
as the main valve.
The pilot valve controls opening and closing the main valve. N.C. or N.O.
function conversion can be done by switching the pilot passage.
Overtravel spring
Keeps surface pressure against the valve
constant and compensates for stroke.
Switching plate
N.C. or N.O.
conversion possible
Housing
Has pilot exhaust port and
external pilot supply port.
Pilot pressure External pilot type
receiving chamber
Main valve
Pressure-return style poppet
valve with special mechanism.
Body
Wear-resistant aluminum alloy
Sintered bronze
Return spring Element
Assures returning
in case of drop-out.
Note) Pilot valve and body are shown in a different direction from
the actual product in order to show the construction and air
passage.
Pilot valve
VP
2. Following the above piping, vacuum
passage is switched between OUT and
EXH, therefore, N.C./N.O. indication on Switching VG
plate
the function plate and switching of the
vacuum passage are reversed; N.C. VP3쏔
(Normally closed) in vacuum passage are
reversed:
1497
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1498
Series VP3145
Dimensions: VP3145
Grommet: VP3145쏔-쏔쏔G AB 쏔
Manual
override External pilot port Lead wire length 200 mm
(EXH port)
(PE port)
Mounting
hole
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
1498
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1499
Dimensions: VP3165
Grommet: VP3165쏔-쏔쏔G AB 쏔
Manual
override External pilot port Lead wire length 200 mm
(PE port)
(EXH port)
Mounting
hole
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
SYJ
VQZ
VP
VG
VP3쏔
1499
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1500
Series VP3185
Dimensions: VP3185
Grommet: VP3185쏔-쏔쏔G AB 쏔
Manual
override External pilot port Lead wire length 200 mm
(PE port)
(EXH port)
Mounting
hole
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
1500
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1501
Made to Order:
Series VP3145/3165/3185
Main Valve Double Acting Type: -X80/X81
How to Order
VP31 4 5 06 1 D Z A 1 N X 81
CE-compliant
Body size Nil —
4 1 2 Q CE-compliant∗
6 1 ∗Electrical entry: D/DO only
8 11 2
VF3 40
CE-compliant
SYJ
Type of actuation Nil —
1 Single solenoid Q CE-compliant∗
VQZ
Light/Surge voltage suppressor
2 Double solenoid ∗Electrical entry: D/DO only
Nil None
Z With light/surge voltage suppressor
VP
Coil rated voltage S With surge voltage suppressor
1 100 VAC, 50/60 Hz ∗ Indicator light is not available for VG
2 200 VAC, 50/60 Hz grommet type. W/ surge voltage
3∗ 110 to 120 VAC, 50/60 Hz suppressor is available for grommet VP3쏔
4∗ 220 VAC, 50/60 Hz type only.
5 24 VDC Electrical entry
6∗ 12 VDC G Grommet (Lead wire: 300 mm)
7∗ 240 VAC, 50/60 Hz H Grommet (Lead wire: 600 mm)
9∗ Other E Grommet terminal
∗ Option T Conduit terminal
L, M plug connector is 220 VAC D With connector
at the maximum. DIN terminal
DO Without connector
L With lead wire
LN L plug connector Without lead wire
LO Without connector
M With lead wire
MN M plug connector Without lead wire
MO Without connector
1501
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1502
Series VP3145/3165/3185
JIS Symbol
Specifications
-X80 Valve configuration External pilot 3 port solenoid valve
(OUT) Type of actuation Double solenoid (-X80), Single solenoid (-X81)
2 Fluid Air
Operating pressure range –101.2 kPa to 0.8 MPa
Pilot pressure 85 to 115% of main pressure, Min. 0.2 MPa
Ambient and fluid temperature 0 to 50°C (No freezing)
1 3 X Lubrication (1) Required (Equivalent to turbine oil Class 1 ISO VG32)
(IN) (EXH) (PA) Mounting orientation Unrestricted
N.C. Impact/Vibration resistance (2) 150/50 m/s2
Note 1) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in
-X81 the axial direction and at the right angles to the main valve and
armature in both energized and de-energized states every once
(OUT) (OUT) for each condition. (Values at the initial period)
2 2 Vibration resistance: No malfunction occurred in a one-sweep test between 45 and
1000 Hz. Test was performed at both energized and de-
energized states in the axial direction and at the right angles
to the main valve and armature. (Values at the initial period)
1 3 X 1 3 X
(IN) (EXH) (PA) (IN) (EXH) (PA) Solenoid Specifications
N.C. N.O.
Grommet, Grommet terminal, Conduit terminal
Electrical entry
DIN terminal, L plug connector, M plug connector
Caution
Piping and other usage are the same as standard products.
Dimensions
VP3145-쏔쏔DZA1-X81 35 134 Max.10
87.4
21
EXH.1
51
71
EXH.2
80
Manual override
(Non-locking)
Applicable cable O.D.
Pg9 ø6 to ø8
2 x 1/8
(Pilot EXH) 1/4
(External pilot
port)
2 x ø8.5
(Mounting hole)
EXH
205.1
196.1
PE PA
156
103
119
112
93
OUT EXH IN
65
62
42
42
25
Dimensions
VP3165-쏔쏔DZA1-X81 21 146.5 Max.10
113
87.4
21
EXH.1
51
71
EXH.2
95
Manual override
(Non-locking)
Pg9 Applicable cable O.D.
ø6 to ø8
1/4
2 x 1/8 (External pilot
Pilot EXH port)
2 x ø8.5
(Mounting hole)
EXH
221
230
PE PA
137
144
128
118
85
78
OUT EXH IN
55
55
25
11/4
(EXH port)
36 82.6 36
2 x 3/4 , 1, 1 1/4
(IN, OUT port)
• When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.
• In the case of -X80, VF3240-쏔쏔쏔 (Pilot valve) will be mounted.
VP3185-쏔쏔DZA1-X81
6 160.3 Max.10
140
87.4
26.5
EXH.1
56
76
81
EXH.2
105
Manual override
(Non-locking)
Applicable cable O.D.
Pg9
ø6 to ø8 SYJ
1/4
2 x 1/8 (External pilot VQZ
Pilot EXH port)
2 x ø13 VP
(Mounting hole)
EXH
VG
243.1
250.7
PE PA
VP3쏔
159
166
150
140
105
90
OUT EXH IN
62
62
25
2
41 118 (EXH port) 41
2 x 1 1/ 4, 11/2 , 2
(IN, OUT port)
• When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.
• In the case of -X80, VF3240-쏔쏔쏔 (Pilot valve) will be mounted.
1503
P1431-P1504-E.qxd 08.9.2 3:52 PM Page 1504
Series VP3145/3165/3185
Specific Product Precautions
Be sure to read before handling.
Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port
Solenoid Valve Precautions.
Coil
With indicator None Neon bulb
Coil
Coil
OUT port open to the atmosphere or in a LED
light (L)
similar operation.)
Coil
Varistor
This solenoid valve is pressure- suppressor (S)
unbalanced type. Operate it within this 48 VDC or less 100 VAC or more
pressure range: IN ≥ OUT ≥ EXH. If not With light/surge
Neon bulb LED Neon bulb
operated in the range, the valve will
Coil
Coil
Coil
voltage None
malfunction. Varistor Varistor Varistor
suppressor (Z)
1504