Anda di halaman 1dari 5

33-50-00 OPT 10000-001

OPERATIONAL TEST OF
EMERGENCY LIGHTING
1 DEC13

ZONING DATA
___________

ZONE : 210 220 230 240 250

PREPARATION
___________

PROVISION

WORK : SKILL
_____ ___
MEN _________
MAN-HOURS

ELAPSED TIME :

PUBLICATION
___________

JIC : DC AND AC CONSTANT 24-46-00-EAD-10000


FREQUENCY EXTERNAL POWER
SUPPLY

GA 33-50-00
OPT 10000-001
2-400 PAGE 1
DEC 01/13
33-50-00 OPT 10000-001
OPERATIONAL TEST OF
EMERGENCY LIGHTING
2 DEC13

001 ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


___________________________________________
FREQUENCY NETWORK
_________________

SEE JOB INSTRUCTION CARD


244600-EAD-10000

002 ______________________________________
OPERATIONAL TEST OF EMERGENCY LIGHTING

REF. FIG. 335000-OPT-00100

1. ON CIRCUIT BREAKER PANEL 122VU,


CHECK THAT THE FOLLOWING CIRCUIT BREAKER IS
CLOSED :
6WL COMPT LT & SERVICING/CABIN/EMER EXIT LT

2. ON PANEL 24VU,
CHECK THAT SWITCH 2WL (1) IN DISARM
POSITION
- CHECK THAT DISARM LIGHT 4WL (2) IS ON
AMBER AND THAT ALL EMERGENCY LIGHTING IS
OFF.

3. ON FLIGHT ATTENDANT PANEL (10MW),


A. PRESS EMERGENCY LIGHT PUSHBUTTON SWITCH
(3)
CHECK THAT:
- PUSHBUTTON SWITCH COMES ON,
- ALL EMERGENCY LIGHTING IS ON, INCLUDING
THE HANDLE LIGHTING OF THE TWO TYPE III
EMERGENCY EXITS.

B. RELEASE EMER LT PUSHBUTTON SWITCH (3).


CHECK THAT :
- PUSHBUTTON SWITCH GO OFF
- ALL EMERGENCY LIGHTING GO OFF.

4. ON PANEL 24VU,
PLACE SWITCH (1) IN ARM POSITION
CHECK THAT :
- DISARM LIGHT (2) IS OFF
- ALL EMERGENCY LIGHTING IS ON, INCLUDING

*** CONTINUED ***

GA 33-50-00
OPT 10000-001
2-400 PAGE 2
DEC 01/13
33-50-00 OPT 10000-001
OPERATIONAL TEST OF
EMERGENCY LIGHTING
3 DEC13

THE HANDLE LIGHTING OF THE TWO TYPE III


EMERGENCY EXITS.

5. ON PANEL 122VU,

A. OPEN CIRCUIT BREAKER 6WL.


- CHECK THAT ALL EMERGENCY LIGHTING
GOES OFF AND IMMEDIATELY COMES ON.

B. CLOSE CIRCUIT BREAKER 6WL.


- EMERGENCY LIGHTING REMAINS ON.

6. ON PANEL 24VU,
PLACE SWITCH (1) IN DISARM POSITION
- AMBER LIGHT COMES ON
- CHECK THAT ALL EMERGENCY LIGHTING GOES
OFF.

7. ON PANEL 24VU,
PLACE SWITCH (1) IN ON POSITION
- CHECK THAT ALL EMERGENCY LIGHTING IS ON
INCLUDING THE HANDLE LIGHTING OF THE TWO
TYPE III EMERGENCY EXITS.

8. ON PANEL 122VU,

A. OPEN CIRCUIT BREAKER 6WL


- CHECK THAT ALL EMERGENCY LIGHTING
GOES OFF AND IMMEDIATELY COMES ON.

B. CLOSE CIRCUIT BREAKER 6WL


- CHECK THAT ALL EMERGENCY LIGHTING
IS STILL ON.

9. ON PANEL 24VU,
PLACE SWITCH (1) IN DISARM POSITION.
- AMBER DISARM LIGHT (2) IS ON
- ALL EMERGENCY LIGHTING GOES OFF.

*** CONTINUED ***

GA 33-50-00
OPT 10000-001
2-400 PAGE 3
DEC 01/13
33-50-00 OPT 10000-001
OPERATIONAL TEST OF
EMERGENCY LIGHTING
4 DEC13

003 DE-ENERGIZATION OF AIRCRAFT DC AND AC CONSTANT


______________________________________________
FREQUENCY NETWORK
_________________

SEE JOB INSTRUCTION CARD


244600-EAD-10000

***** E N D O F T E X T *****

GA 33-50-00
OPT 10000-001
2-400 PAGE 4
DEC 01/13
33-50-00 OPT 10000-001
5 DEC13

GA OPERATIONAL TEST
OF EMERGENCY LIGHTING
33-50-00
OPT 10000-001
2-400 PAGE 5
DEC 01/13

Anda mungkin juga menyukai