Anda di halaman 1dari 3

MASTERTOP® 1270 AS

Formerly Conifloor AS-EP


Anti static, self smoothing flooring system

DESCRIPTION PROPERTIES
MASTERTOP 1270 AS is a self-smoothing, anti static, a. Components
solvent free epoxy flooring system. The cured floor Supply Density
Colour
exhibits excellent antistatic properties and finishes to a form kg/L
smooth, seamless surface with an attractive appearance Mastertop
that can be easily maintained in a hygienic condition. liquid amber 1.10
Primer 9 Part A
Mastertop
RECOMMENDED FOR liquid amber 1.05
Primer 9 Part B
Mastertop Body
MASTERTOP 1270 AS is ideal for use where electronic coloured
Coat 370 AS liquid 1.46*
components could cause an explosion by static amber
Part A + Part B
electricity and/or stray currents generated by friction.
MASTERTOP 1270 AS is recommended for floors in: Mastertop CP
687 W AS liquid white
• electronic industries
Part A
• wafer and PC component production 1.07*
Mastertop CP
• synthetic fibre mills
687 W AS liquid coloured
• processing and handling of combustible goods Part B
• operating theatres and recovery rooms Filler F5 solid white 2.60
FEATURES AND BENEFITS * Part A and Part B mixed

Anti-static Dissipates static charges that could b. Mixed systems


cause sparks or damage electronic Mix ratio by
Components
parts. weight
Good Durable in chemically aggressive Mastertop Primer 9 A:B 100:27
chemicals areas. Mastertop CP 687
A:B 2:3
resistance W AS
Easy to apply Allows floor surface to be Mastertop Body Coat
A:B 100:16
maintained in a hygienic state. 370 AS
Seamless Is free of joins that collect dirt and
allow ingress of pollutants. Pot-life (minutes)
Complies with Complies with DIN 51953, DIN @ 10°C @ 20°C @ 30°C
international EN1081,IEC and NFPA. BS 2080, Mastertop
standards UL 779. 70 35 20
Primer 9
Mastertop
TYPICAL PERFORMANCE DATA CP 687 W 120 60 30
7 days cure @ 20 C
o AS
Compressive strength (DIN 1164) : 65 N/mm
2 Mastertop
Flexural strength (DIN 1048) : 58 N/mm2 Body Coat 60 30 20
Bond strength (DIN ISO 4624) : < 2.5 N/mm2 370 AS
Abrasion resistance (DIN 53754) : 55 mg Curing time (days)
Elongation (DIN 53504) : 10% @ 10°C @ 20°C @ 30°C
Shore D Hardness : 80
Resistivity : >1x104 to- Mastertop
5 2 1
(DIN 51953, BS 2050, UL 779) <1x106 Primer 9
Resistivity (Scandinavia)
5
: >1x10 to-
Mastertop
<1x10 
6 CP 687 7 5 2
Resistivity
6
: >1x10 to-
W AS
(DIN 1081, NFPA, IEC) <1x109 Mastertop
Service Temperature : -20°C to 60°C Body Coat 10 5 2
Application Temperature : Minimum 10°C 370 AS
Maximum 35°C
Head Office Factories Representative Offices
Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® 1270 AS
Maximum permissible relative humidity However, consult with the owner or his consultant,
@ 10°C at >23°C regarding possible special grounding requirements. The
All components 75% 90% placed copper strips are subsequently connected to an
approved ring conductor/bus bar which is connected to
an approved ground pole. It is beyond the scope of the
flooring material supplier to design, specify or install the
grounding system, such work must be carried out and
APPLICATION
designed by a qualified electrician or in conjunction with
Surface Preparation the owner’s safety or quality control officer.
The compressive strength of the substrate must not be
less than 30 N/mm2. The substrates in contact with the CONDUCTIVE PRIMER
ground must have a vapour barrier installed in Mixing
compliance with DIN 18195 or equivalent, or be primed Use a low speed (300 rpm) electric drill fitted with a paint
with Mastertop Primer 9. The moisture content of the mixer or a wing type paddle.
substrate shall not be higher than 8% throughout (Test Premix one set of Mastertop CP 687 W AS.
using with CM equipment). The temperature of the Placing
substrate must be at least 3°C above the current dew For placing please refer to relevant Product Data
point temperature. Sheets.
Correct substrate preparation is critical for optimum
performance. Surfaces must be structurally sound, BODY COAT
clean, and free from loose particles, oil, grease, and all Mixing
other contaminants. Use a low speed (300 rpm) electric drill fitted with a paint
Remove oil, grease and wax contaminants by scrubbing mixer or a wing type paddle.
with industrial grade detergent or degreasing Mix one unit of Mastertop Body Coat 370 AS Part A with
compounds followed by mechanical cleaning. Cement one unit Mastertop Body Coat 370 AS Part B and mix for
laitance, loose particles, mould release agents, curing at least 3 minutes or until the mix is uniform in colour
membrane and other contaminants must be removed and free of streaks.
from the surface by shot blasting, Blastrac®, scarifying Placing
or rit-blasting followed by vacuum cleaning. After Depending on the substrate condition, apply 2.0 to 2.8
pretreatment of the substrate, the bond strength of the kg/m2 of the mix, by pouring out the whole mix at once
substrate must be at least 1.5 N/mm2 (check with an into pours being approximately 200 to 300 mm wide
approved pull-off tester at load rate 100 N/s). running parallel to the work direction. Distribute and level
Fill surface irregularities such as blowholes, cracks, the material with a notched trowel with the following
honeycombs, etc. with an EMACO® repair mortar to dimensions: Notch size, width/height/separation: 3/5/10
achieve a smooth and level surface. mm) Allow the placed material to rest for 10 to 15 min.,
Protect walls and columns against resin splashes using then de-aerate with a spike roller.
masking tape and polythene sheeting.
ESTIMATING DATA
PRIMER For thickness of 2.0mm (One body coat only)
Mixing Thicknes
System Product kg/m2
Use a low speed (300 rpm) electric drill fitted with a paint s mm
mixer or a wing type paddle. Primer Mastertop
0.2 - 0.4 0.3 - 0.4
Premix one unit of Mastertop Primer 9 Part A with one Primer 9
unit of Mastertop Primer 9 Part B for at least 3 minutes Conductive Mastertop
until the mix is uniform and free of streaks. Primer CP 687 W 0.08 - 0.1 0.1
AS
Placing Body coat Mastertop
Immediately after mixing, pour the material onto the Body
substrate and spread the mixed material using a 2.0 - 2.5 1.5 - 2.0
Coat 370
squeegee or paint roller. The main purpose of this AS
primer coat is to seal the substrate completely and
avoiding air bubbles in the body coat. On very porous
PACKAGING
substrates a second primer/sealer coat may be
required. If in doubt apply a sample patch of body coat. Mastertop Body Coat 370 AS 30.0 kg/se
Mastertop Primer 9 30.0 kg/set
Copper grounding strips Mastertop CP 687 W AS 15.0 kg/set
When the primer has cured, self-adhesive copper strips
10 to 20 mm wide and 300 to 400 mm long are bonded SHELF LIFE
to the primed surface. As a rule, one strip per 100 m2
complies with all norms. For large areas, it is prudent to MASTERTOP 1270 AS can be kept for 12 months from
place one or two strips longitudinal and parallel to the date of manufacture if stored in original unopened
walls. The above mentioned strips are grounded near a packaging, in a dry enclosed place at temperatures
column in the mid section of the floor. between 15 to 35°C without exposing to direct sunlight.
MASTERTOP® 1270 AS
PRECAUTIONS
MASTERTOP 1270 AS contains certain chemicals
which can cause skin irritation if exposed and respiratory
reaction if inhaled. Wear gloves, masks and use hand
barrier cream while handling the product. Wash
thoroughly after handling.
Should skin contact occur, wash immediately with soap
and water or an effective hand cleaner.
In case of accidental eye contact, wash with copious
quantity of water and immediately seek medical advice.
If ingested, do not induce vomiting. Consult doctor
immediately. Vapours of solvents used for cleaning can
be irritating. It is therefore recommended that cleaning
be done in wellventilated areas.
For detailed Health, Safety and Environmental
Recommendations, please consult or follow all
instructions on the product Material Safety Data Sheet.

Fire: Keep away from sources of ignition. Do not smoke


whilst handling the product.
Flash point: 110°C.
MT 1270AS/04/0301

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.