This document contains measurements and calculations related to an orifice located at a decanter outlet. It lists the flow rate, inlet and outlet pressures, pipe and orifice diameters, discharge coefficient values, and calculations of the orifice area and diameter. The orifice diameter was determined to be 196 mm with 4 holes, each with an area of 7525.19 sq. mm.
This document contains measurements and calculations related to an orifice located at a decanter outlet. It lists the flow rate, inlet and outlet pressures, pipe and orifice diameters, discharge coefficient values, and calculations of the orifice area and diameter. The orifice diameter was determined to be 196 mm with 4 holes, each with an area of 7525.19 sq. mm.
This document contains measurements and calculations related to an orifice located at a decanter outlet. It lists the flow rate, inlet and outlet pressures, pipe and orifice diameters, discharge coefficient values, and calculations of the orifice area and diameter. The orifice diameter was determined to be 196 mm with 4 holes, each with an area of 7525.19 sq. mm.
Pressure at the inlet of orifice kg/cm2 0.79 311.02 inch 0.25 0.54 Pressure kg/cm2 0.49 192.91 inch 0.3 0.55 drop 0.35 0.56 0.4 0.57 Pipe dia mm 300 0.45 0.58 0.5 0.59 Orfice dia mm 196 assumed 0.55 0.6 0.6 0.615 O/P ratio 0.65 0.65 0.635 0.7 0.665 C value 0.635 0.75 0.715 0.8 0.8 Calculated A 46.66 sq.inch 30100.76 sq.mm
Calculated Orifice dia 195.77 mm No of holes 4
Area Per hole 7525.19 Orifice Size 196 mm Orifice size per hole 97.91 100 mm x 4 nos