Anda di halaman 1dari 5

TABLE OF CONTENTS

1. INTRODUCTION......................................................................................................2
2. BASIS OF DESIGN..................................................................................................2
2.1 Design Parameters...................................................................................................2
2.2 Design Method......................................................................................................... 2
2.3 Codes and Standards, References and Programs...................................................3
2.3.1 Codes and Standards...............................................................................................3
2.3.2 References...............................................................................................................3
2.3.3 Computer Programs.................................................................................................3
2.4 THREE DIMENSIONAL VIEW OF GAS TEST BUNKER..........................................3
3. GAS TEST BUNKER FOUNDATION DESIGN........................................................4
3.1 SUPERSTRUCTURE LOADINGS............................................................................4
Dead Load (DL)..................................................................................................................4
Live Load (LL):.................................................................................................................... 4
3.2 LOAD COMBINATIONS...........................................................................................4
4. APPENDICES A (DESIGN OUTPUT)......................................................................5
I. (STAADPRO MEMBER LABEL FORMAT).....................................................................5
1. INTRODUCTION

This document contains the Structural calculations for strip foundation design for Gas test
bunker. The design is in accordance to relevant British Standards (BS)

2. BASIS OF DESIGN

2.1 Design Parameters


Description Value
In-situ Reinforced Concrete Walls with
Type of structure reinforced concrete ground slab provided
with isolation joints.
Unit wt of concrete 24 KN/m3
Concrete grade C 25 N/mm2
Type of foundation Strip Footing
Grade of reinforcing steel 410 N/mm2 - high yield steel
Cement types Substructure: Ordinary Portland cement
Foundation Elements
Concrete covers Top – 25mm
Bottom – 50mm
Floors – 5ton/m2,
Live Load
Roof without access –0.75kN/m2
Roof - 0.75kN/m2
Dead Load
Finishes – 1.2kN/m2
Bearing Capacity 60kN/m2 (assumed)
Design method Ultimate Limit state (ULS)

2.2 Design Method


The Structural engineering detailed design of the proposed Gas test bunker substructure has
been carried out to suit the relevant Architectural drawings. The design is in accordance with
construction methodology and sub-soil conditions at the proposed site. The building is basically
composed of reinforced concrete wall. The foundation has been designed as strip footing while
the ground slab (250mm thick) which is provided with isolation joint was designed as slab on
grade. No geotechnical report was available as at the time of carrying out this analysis but a
bearing capacity of 60kN/m2 was assumed conservatively.
The superstructure service loading including the ground floor live and superimposed dead load
was modelled in STAAD Pro and the reactions generated were appropriately designed for using
STAAD Pro.

Note: This foundation design covers for the strip footing for the paint booth 1 & 2 and the blast
booth structure.

2.3 Codes and Standards, References and Programs


2.3.1 Codes and Standards
BS 8110: Part 1 : The Structural Use of Concrete
BS 8004 : Code of practice for Foundations
2.3.2 References
1. Reinforced Concrete Designers Manual by Reynolds and Steedman
2. Foundation Analysis and Design by Joseph E. Bowles
3. Reinforced Concrete Design by Mosley, Bungey and Hulse

2.3.3 Computer Programs


1. StaadPro design software

2.4 THREE DIMENSIONAL VIEW OF GAS TEST BUNKER

PLATE A: ISOMETRIC VIEW

3. GAS TEST BUNKER FOUNDATION DESIGN


Building Geometry
Width of Building = 6m
Length of Building =6m
Height of Building = 3.2m

3.1 SUPERSTRUCTURE LOADINGS


A summary of the superstructure gravity loadings on the entire building frame is presented
in the sections below. The ground slab was separated from the wall by providing isolation
joints. The ground slab design was done separately from the wall footing design; refer to
section ----- for the ground slab design.
Dead Load (DL)
Weight of Wall = StaadPro software automatically calculates this and applies it
appropriately
Roof Dead Load = 0.75KN/m2
Live Load (LL):
Roof Live Load = 0.75KN/m2

Ground Slab Loading


Dead Load:
Floor Finishes = 1.2KN/m2
Partitions = 1.0KN/m2
M & E services = 0.5KN/m2
Total Dead Load = 2.7KN/m2
Live Load (LL)
Slab imposed Load = 5ton/m2

3.2 LOAD COMBINATIONS


The load combinations listed below were considered in the design and analysis of the gas
test bunker strip footing;

 Combination 1
1.4DL + 1.6LL – Ultimate
1.0DL + 1.0LL – Service

3.3 ELEMENT DESIGN APPROACH


4. APPENDICES A (DESIGN OUTPUT)
I. (STAADPRO MEMBER LABEL FORMAT)