Anda di halaman 1dari 173

CLASS A

General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

A100 CONTRACTUAL REQUIREMENTS

Bond

A111 Performance Bond. sum

A112 Design Guarantee Bond [for roof structure (to be sum


designed by the Contractor) of (………..)].

Insurances

A121 Insurance of the Works. sum

A122 Public Liability Insurance. sum

A123 SOCSO/Workmen Compensation Insurance. sum

Statutory Obligations

A131 CIDB Levy. sum

A140 Stamp duty. sum

A200 ENGINEER/SO/PD'S REQUIREMENTS

Facilities for the Engineer/SO/PD's representative.


Rate shall be deemed to include the provision of water
supply, electricity, and communication facilities.

A211 Establishment and removal of [transportable type cabin] sum


office [with a floor area of 70 m2].

A212 Maintenance of office. mth

A213 Establishment and removal of [purpose built] sum


laboratories [with a floor area of 60 m2 as shown in
Drawing Nos. (……….) to (……..)].

A214 Maintenance of laboratories. mth

Equipment for Use by the Engineer/SO/PD's


Representative

A221 Establishment and removal of office equipment [with sum


type and quantity as per Specification clause (……).
Equipment to be reverted to the Contractor after
completion].

A222 Maintenance of office equipment. mth

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA1 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

A223 Establishment and removal of laboratory equipment sum


[with type and quantity as per Specification clause
(……). Equipment to be reverted to the Contractor after
completion].

A224 Maintenance of laboratory equipment. mth

A225 Surveying equipment [with type and quantity as per the sum
Specification, Clause (……). Equipment to be reverted
to the Contractor after completion].

A226 Maintenance of survey equipment. mth

Services for the Engineer/SO/PD's Representative

A231.1 Provision of transport vehicle [Type A as per sum


Specification clause (…..). Vehicle to be reverted to the
Contractor after completion].

A231.2 Provision of transport vehicle [Type B as per sum


Specification clause (…..). Vehicle to be reverted to the
Contractor after completion].

A232.1 Maintenance of vehicle [Type A]. mth

A232.2 Maintenance of vehicle [Type B]. mth

A233 Provision of mobile phones [and to be reverted to the sum


Contractor after completion].

A234 Maintenance of mobile phones. mth

A235 Provision of camera [and to be reverted to the sum


Contractor after completion].

Attendance for Engineer/SO/PD's Representative

A241 [2 Nos.] Drivers for [Type A and Type B vehicle]. man-mth

A242 [2 Nos.] Survey assistants. man-mth

A243 [2 Nos.] Laboratory assistants. man-mth

A244 [4 Nos.] General labours. man-mth

A245 [2 Nos.] Security guards. man-mth

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA2 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Submission of Documents

A251 Project execution plan [as per Specification clause sum


(…..)].

A252 Drawings [as per Specification clause (…..)]. sum

A253 Method statement [as per Specification clause (…..)]. sum

A254 Work programme [in Microsoft Project on a Gantt Chart sum


format].

Miscellaneous

A261 Progress report [ in five sets]. Rate to include progress mth


photographs.

A262 Project signboard. nr

A263 As built drawings. sum

A264 Video recording [as per Specification clause (....)]. sum

A265 Temporary fencing and hoarding. sum

A300 PROJECT REQUIREMENTS

A310 Survey and setting out [by licensed surveyor]. sum

Quality Assurance/Quality Control (QA/QC)

A321 QA/QC Plan [as per Specification clause (…..)]. sum

A322
Testing of materials; [concrete test cubes; samples and
sum
method of testing as per Specification clause (…..)].

A323 Testing of work [for cold water plumbing system as per


sum
Specification clause (….)].

A324 Factory acceptance test [for hydrostatic testing of


butterfly valves] for three (3) person of the S.O. sum
representatives.

A325 Testing and commissioning [of plant for a duration of


sum
three (3) months].

Operation and Maintenance of Plant

A331 Operation and Maintenance Manual. sum

A332 Training of operating personnel [for a period of 10 sum


weeks].

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA3 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

A333 Provision of manpower [for a period of 12 months]. sum

A334 Provision of chemicals and consumable [for a period of sum


12 months].

A335 Utility cost [for a period of 12 months]. sum

Maintenance of Road

A341 Routine maintenance for existing road as per sum


Specification clause […..].

A342 Periodic maintenanceas for existing road per sum


Specification clause […..].

A343 Routine maintenance for temporary road diversion as sum


per Specification clause […..].

A344 Periodic maintenance for temporary road diversion as sum


per Specification clause […..].

A350 Clearance of site upon completion. sum

A400 AUTHORITIES' REQUIREMENTS

Occupational Safety and Health Requirements

A411 Health and safety plan. sum

A412 Occupational safety and health officer [for duration of man-mth


the contract period].

A413 Personnel protective equipment as per Specification sum


clause […..].

A414 Health and safety report [in five sets. Rate to include mth
tool box meeting].

A415 Training of health and safety as per Specification clause sum


[…..].

A416 Safety signages. sum

A420 Permits and fees [to KTMB for pipe jacking work across sum
railway tracks at (…….)].

A430 Deposit [to JKR for pipelaying work along road verge sum
from (……..) to (……………)].

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA4 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

A500 CONTRACTOR'S REQUIREMENTS

Facilities
Item shall be deemed to include the provision of water
supply, electricity, and sanitary facilities and their
continuing operation and/or maintenance.

A511.1 Set up offices and remove upon completion; fixed sum


charge.

A511.2 Maintain office for duration of contract period; time- sum


related charge.

A512.1 Provision of office equipment and remove upon sum


completion; fixed charge.

A512.2 Maintain office equipment for duration of contract sum


period; time-related charge.

A513.1 Set up laboratories and remove upon completion; fixed sum


charge.

A513.2 Maintain laboratories for duration of contract period; sum


time-related charge.

A514.1 Provision of laboratories equipment and remove upon sum


completion [with type and quantity as per Specification
clause (……)].

A514.2 Maintain laboratories equipment for duration of contract sum


period; time-related charge.

A515.1 Set up stores and remove upon completion; fixed charge. sum

A515.2 Maintain store for duration of contract period; time- sum


related charge.

A516.1 Set up workshops and remove upon completion; fixed sum


charge.

A516.2 Maintain workshop for duration of contract period; time- sum


related charge.

A517.1 Set up workmen accomodation and remove upon sum


completion; fixed charge.

A517.2 Maintain workmen accomodation for duration of sum


contract period; time-related charge.

A518.1 Provision of transport. sum

A518.2 Maintain transport for duration of contract period; time- sum


related charge.

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA5 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Temporary Work

A521.1 Construct temporary access roads to site; fixed charge. sum

A521.2 Maintain temporary access roads for duration of contract sum


period; time-related charge.

A522.1 Construct temporary bridges and remove upon sum


completion [over Sg. (……)]; fixed charge.

A522.2 Maintain temporary bridges for duration of contract sum


period; time-related charge.

A523.1 Construct cofferdams for [water intake] and remove sum


upon completion; fixed charge.

A523.2 Maintain cofferdam for duration of construction; time- sum


related charge.

A524.1 Install pumping and dewatering at [pumphouse] and sum


remove upon completion; fixed charge.

A524.2 Operation and maintenance of pumping and dewatering sum


for duration of construction; time-related charge.

A525.1 Construct river diversion for [water intake] and reinstate sum
to its original alignment upon completion; fixed charge.

A525.2 Maintain river diversion for duration of construction; sum


time-related charge.

A526.1 Construct temporary jetty [at Sg. (……)] and remove sum
upon completion; fixed charge.

A526.2 Maintain temporary jetty for duration of contract period; sum


time-related charge.

A527.1 Construct temporary staging over [Sg. (…….)] and sum


remove upon completion; fixed charge.

A527.2 Maintain temporary staging for duration of construction; sum


time-related charge.

Site Management

A531 Site agent for the duration of conract period; time- sum
related charge.

A532 QA/QC officer for the duration of contract period. man-mth

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA6 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

A540 Mobilisation and demobilisation. [Rate to include sum


remobilisation for testing and commissioning of the
plant after the completion of the pipelaying work under
Package (2)].

A600 DESIGN AND BUILT ELEMENT

A610 Preliminary engineering studies. sum

A620 Design survey. sum

A630 Utilities survey. sum

A640 Site investigation. sum

A650 Design fees. sum

Independent Checkers

A661 Structural. sum

A662 Geotechnical. sum

A663 Road safety. sum

A670 Supervision fees. sum

A700 PROVISIONAL/PRIME COST SUMS

Provisional Sums

A711.1 Provisional Sum of [RM: Two hundred thousands only sum


for TNB contribution].

A711.2 Provisional Sum of [RM: Five hundred thousands only sum


for piling work].

A711.3 Provisional Sum of [RM: Three hundred thousands only sum


for staff quarters to be procured by the Employer].

A711.4 Attendance [for Item A711.3]. sum

A711.5 Profit for [Item A711.3]. %

Prime Cost Items

A721 Prime Cost Sum of [RM: One million only for reinforced sum
soil wall].

A722 Attendance. sum

A723 Profit. %

Page Total carried to Summary of Class A

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA7 of BQA173
CLASS A
General Items

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class A: General Items

Page BQA1

Page BQA2

Page BQA3

Page BQA4

Page BQA5

Page BQA6

Page BQA7

Total of Class A carried to Grand Summary

Class A: General Items


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQA8 of BQA173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

B100 ENVIRONMENTAL MANAGEMENT PLAN


(EMP)

B110 Preparation of environmental management plan which sum


shall include erosion and sediment control plan (ESCP),
flora and fauna management plan by a consultant,
registered with the Department of Environment.

B120 Appointment of environmental officer (EO) for the man-mth


duration of the contract period.

B200 EROSION AND SEDIMENT CONTROL PLAN


(ESCP)
Items for silt fence, silt curtain, sand bags, gabion wall,
and rock check dam shall be deemed to include
provisions as per Specification clause (............) and
removal of the items upon completion.

B210 Silt fence of [1.0 m height] as per Specification clause m


(…..) and as shown in the drawings.

B220 Silt curtain as per Specification clause (….) and as m2


shown in the drawings.

B230 Sand bag as per Specification clause (….) and as shown nr


in the drawings.

B240 Rock-filled gabion wall with PVC coated wire gauge m3


size of [2.7 mm] as per Specification clause (….) and as
shown in the drawings.

B250 Rock check dam as per Specification clause (….) and as m3


shown in the drawings.

Sediment Basin

B261 Excavation. m3

B262 Granular filling. Rate to include imported fill as m3


necessary.

B263 Concrete grade [C25]. Rate to include formwork and m3


reinforcement.

B264 Class X, 1.0 m diameter reinforced concrete pipe. m

B265 Geotextile as per Specification clause (….). m2

B266 Rock-filled gabion with PVC-coated wire gauge size of m3


[2.7 mm] as per Specification clause (….).

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB9 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

B267 Rock-filled gabion mattress, 300 mm thick with PVC- m2


coated wire gauge size of [2.7 mm] as per Specification
clause (….).

B268 Riprap of 300 mm average thickness. m2

Silt Trap

B271 Excavation. m3

B272 Granular filling. Rate to include imported fill as m3


necessary.

B273 Concrete grade [C25]. Rate to include formwork and m3


reinforcement.

B274 Class X, 1.0 m diameter reinforced concrete pipe. m

B275 Geotextile as per Specification clause (….). m2

B276 Rock-filled gabion with PVC-coated wire gauge size of m3


[2.7 mm] as per Specification clause (….).

B277 Rock-filled gabion mattress, 300 mm thick with PVC- m2


coated wire gauge size of [2.7 mm] as per Specification
clause (….).

B278 Riprap of 300 mm average thickness. m2

Maintenance

Items for maintenance of silt fence, silt curtain, sand


bags, gabion wall, rock check dam, sediment basin, and
silt trap shall be deemed to include disposal of
accumulated debris, sediment and silt to approved site,
unless otherwise stated.

B281 Silt fence. sum

B282 Silt curtain. sum

B283 Sand bag. sum

B284 Gabion wall. sum

B285 Rock check dam. sum

B286 Sediment basin. sum

B287 Silt trap. sum

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB10 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

B300 WATER QUANTITY CONTROL AND


MONITORING

B310 Skid tank bund [at workshop area in reinforced concrete sum
of size 6 m x 4 m x 1 m high] as per Specification clause
(……) and as shown in the drawing. Rate to include
traps, oil and grease separators, and its maintenance and
removal upon completion.

B320 Water treatment facilities for [effluent from tunnel work sum
to comply with Standard (A/B) of the Environmental
Quality Act].

B330 Sewage treatment facilities for [workmen sum


accomodation].

Water Quality Sampling and In situ Testing

Water quality sampling and monitoring by accredited


laboratory on a monthly basis [at the discharge outlet of
silt trap/sedimentation basin to comply with the
requirements of Standard (A/B) of the Environmental
Quality Act for the following parameters].

B341 pH nr

B342 Total suspended solid (TSS). nr

B345 Dissolved Oxygen (DO) nr

B347 Ammoniacal nitrogen nr

Water Quality Sampling and Laboratory Testing

Water quality sampling and monitoring by accredited


laboratory on a monthly basis [at the effluent discharge
point at workmen accommodation, workshop, and
canteen to comply with the requirements of Standard
(A/B) of the Environmental Quality Act for the
following parameters].

B351 pH. nr

B352 Total suspended solid (TSS). nr

B353 Biochemical oxygen demand (BOD). nr

B354 Chemical oxygen demand (COD). nr

B355 Dissolved oxygen (DO). nr

B356 Escherichia coli (E.coli). nr

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB11 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

B357 Ammoniacal nitrogen. nr

B358 Oil and grease. nr

B400 AIR QUALITY CONTROL AND MONITORING

B410 Tyre washing facilities [in reinforced concrete of size 6 set


m x 3.6 m as per Specification clause (…..) and as
shown in the drawing]. Rate to include construction of
tyre washing concrete platform, and provision and
maintenance of water supply system and portable water
jets.

B420 Wash trough of [size 6 m x 3.6 m in reinforced concrete, nr


hardcore, and aggregate layers as per Specification
clause (…..) and as shown in the drawing].

B430 Water bowser truck [for carrying out water spraying nr


along haul/access roads and existing roads, and near
settlements, for at least three times per day]. Rate to
include the provision and maintenance of the vehicle
and water supply, and the driver.

B440 Water sprinkler [for control of dust at quarry/batching sum


plant using pumping system]. Rate to include provision
and maintenance of water supply.

Air Quality Sampling

Air quality sampling by accredited laboratory on a


quarterly basis for the following parameters:

B451 Total suspended particulates (TSP) over a 24 hours nr


period.

B452 Wind velocity and direction. nr

B453 Particulate matter (PM10). nr

B500 NOISE AND VIBRATION CONTROL AND


MONITORING

B510 [Polycarbonate] noise barrier [of 1.5 m height] as per m


Specification clause (….). Rate to include supply,
fabrication, installation, bolts, nuts, posts, and other
ancillary work and maintenance.

B520 Vibration control. sum

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB12 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Noise Level Measurement

Noise level measurement and monitoring by accredited


laboratory [including L10, L90, and Leq on a quarterly
basis near Taman (…..)] for the following parameters.

B531 Ambient noise level measurement. nr

B532 Spot noise level measurement. nr

B540 Vibration measurement and monitoring by accredited sum


laboratory on a quarterly basis near Taman (…..).

B600 WASTE MANAGEMENT

B610 Scheduled wastes as per Specification clause (……). sum


Rate to include storage, labelling, and transportation
from site by a licensed contractor for disposal as per the
Department of Environment (DOE) regulation.

B620 Household solid waste as per Specification clause sum


(……). Rate to include provision of collection bins,
temporary storage area, and disposal to approved site.

B630 Construction solid waste as per Specification clause sum


(……). Rate to include provision of collection bins,
temporary storage area, and disposal to approved site.

B640 Biomass disposal as per Specification clause (……). sum


Rate to include preparation and construction of
temporary area, and the disposal to approved site.

B700 CONSERVATION/PRESERVATION

Preservation of Flora

B711 Flora survey report [in five sets]. sum

B712 Relocation of flora of the (….) species to the temporary nr


site near the [site office] and finally to the (……..) forest
reserve. Rate to include the cost of relocation to the
temporary and the final site specified. It shall also
include excavation, transportation, protection, watering,
fertilizing required, and nurturing until the flora are
established at the temporary and the final site of
relocation.

B713 Relocation of flora of the (…) species to arboreta. nr

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB13 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Preservation of Fauna

B721 Fauna survey report [in five sets]. sum

B722 Relocation of fauna of the (……) species to the nr


temporary site near the [site office] and finally to the
(……..) forest reserve. Rate to include the cost of
temporary relocation to the rehabilitation centre and
final relocation to sites specified. It shall also include
trapping, transportation and protection, and treatment
required for the well being of the fauna at the
rehabilitation centre and before their release at the final
site of relocation/rehabilitation.

Preservation of Archeological/Heritage

B731 Report [in five sets]. sum

B732 Protection. sum

B800 ENVIRONMENT REPORT

B810.1 Environmental monitoring report [in five sets on a sum


monthly basis for the TSS content at the discharge outlet
of the silt trap/sedimentation basin].

B810.2 Environmental monitoring report [in five sets on a sum


quarterly basis for pH, TSS, BOD, COD, DO, e.coli,
ammoniacal nitrogen, and oil and grease, for the
discharge point from the project site at Sg. (………….)].

B810.3 Environmental monitoring report [in five sets on a sum


quarterly basis for pH, TSS, BOD, COD, DO, e.coli,
ammoniacal nitrogen, and oil and grease, for the effluent
discharge point at workmen accomodation, workshop
and canteen].

B810.4 Environmental monitoring report [in five sets on a sum


quarterly basis for ambient air quality].

B810.5 Environmental monitoring report [in five sets on a sum


quarterly basis for noise and vibration measurement].

B820 Environmental audit report [on a annual basis in five sum


sets].

B830 Environmental closure audit report in [five sets]. sum

Page Total carried to Summary of Class B

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB14 of BQB173
CLASS B
Environmental Protection and Enhancement

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class B: Environmental Protection and


Enhancement

Page BQB1

Page BQB2

Page BQB3

Page BQB4

Page BQB5

Page BQB6

Total of Class B carried to Grand Summary

Class B: Environmental Protection and Enhancement


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQB15 of BQB173
CLASS C
Traffic Management and Control

Item No. Code No. Description Unit Qty. Rate Amount (RM)

C100 TRAFFIC MANAGEMENT PLAN

Traffic management plan shall be deemed to include


emergency response plan and the associated work.

C110 Traffic Impact Study sum

C120 Preparation of traffic management plan. Rate to include sum


the cost of any survey required, literature, references,
consultations, and the production of the document. It
shall also include the cost for the engagement of
qualified traffic engineers required for carrying out the
respective study and the preparation of the said plan.

C130 Traffic Management Team

C131 Traffic manager. man-mth

C132 Traffic management officer. man-mth

C133 Supervisor. man-mth

C134 Traffic controller. man-mth

C200 TEMPORARY ROAD FURNITURE

Items for temporary road furniture shall be deemed to


include the supply, installation, maintenance, and
removal upon completion.

The supply of temporary road furniture shall be deemed


to include base preparation, cost of materials,
fabrication, and fixing including posts, struts, bolts and
nuts, base, storage, and transportation.

Installation of temporary road furniture shall be deemed


to include cost for multiple shifting within the
contractual boundaries and its vicinities that is affected
by the traffic management plan.

Temporary road furniture shall be deemed to include


cost for the inspection, immediate repair and
replacement of any damaged, missing or stolen items
throughout the duration of the construction, and removal
upon completion.

Page Total carried to Summary of Class C

Class C: Traffic Management and Control


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQC16 of BQC173
CLASS C
Traffic Management and Control

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Temporary Traffic Signs

Temporary traffic signs shall be in accordance with JKR


Arahan Teknik (Jalan) 2C/85 .

C211.1 Portable non-illuminated retro-reflective in [aluminium] nr


sheeting for [advance warning sign].

C211.2 Portable non-illuminated retro-reflective in [aluminium] nr


sheeting for [detour sign].

C211.3 Portable non-illuminated retro-reflective in [aluminium] nr


sheeting for [obstruction marker].

C211.4 Portable non-illuminated retro-reflective in [aluminium] nr


sheeting for [apologetic sign].

C212 Portable changeable message signs (PCMS) of [2.5 m] x nr


[1.5 m] as per Specification clause (…).

C213.1 Traffic signals with [3] optical system mounted on set


[poles] as per Specification clause (….). Rate to include
signal post, signal lanterns, traffic controllers, cabling,
and removal upon completion.

C213.2 Traffic signals with [3] optical system mounted on set


[gantry]as per Specification clause (….). Rate to include
signal lanterns, traffic controllers, cabling, and removal
upon completion.

Barriers and Barricades

C221 Heavy duty water- or sand-filled PVC barrier of the nr


[New Jersey] type.

C222 [Precast movable reinforced] concrete barrier of the nr


[New Jersey] type.

C223 Wooden barricade. nr

C224 Vehicle mounted impact attenuator. nr

C225 Sand bags. m3

C226 Temporary guardrail. m

Delineators

C231 [750mm] PVC Traffic cones with reflective bands. nr

C232 [Double sided reflective] string delineators. m

C233 [750 x 600mm] battery operated flashing arrows on nr


powder coated mild steel plate.

Page Total carried to Summary of Class C

Class C: Traffic Management and Control


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQC17 of BQC173
CLASS C
Traffic Management and Control

Item No. Code No. Description Unit Qty. Rate Amount (RM)

C234 [115mm] diameter battery operated revolving beacon nr


lights.

C235 [150mm] diameter polycarbonate lens battery operated nr


blinkers.

Temporary Road Markings

C241 Letters and shapes. nr

C241.1 Single straight arrow. nr

C241.2 Single turning arrow. nr

C241.3 Double headed arrow. nr

C242 [150mm] wide continuous line. m

C243 [100mm] wide intermittent line with [1000mm] line and m


[1700mm] gap.

C244 Chevron marking. m2

C245 Transverse bars. m2

C250.1 Mechanical robot flagman [of the full-man type]. nr

C250.2 Mechanical robot flagman [of the full-man type]. nr

C260 Temporary street lightings. nr

C300 TRAFFIC MANAGEMENT REPORT

C310 Traffic management safety report [on a monthly basis in sum


five sets].

C320 Road safety audit report [on a quarterly basis in five sum
sets]. Rate to include the cost of any survey required,
literatures, references, consultations, and the production
of the document. It shall also include the cost for the
engagement of the road safety auditor required for
carrying out the audit and the preparation of the said
audit report.

Page Total carried to Summary of Class C

Class C: Traffic Management and Control


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQC18 of BQC173
CLASS C
Traffic Management and Control

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class C: Traffic Management and


Control

Page BQC1

Page BQC2

Page BQC3

Total of Class C carried to Grand Summary

Class C: Traffic Management and Control


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQC19 of BQC173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D100 MOBILISATION AND DEMOBILISATION


Rate shall be deemed to include provision of all plant
and equipment, transportation to the Site, including
transfer between different locations within the Site,
handling, assembling amd removal off the Site after
completion of operation.

D110 Deep Boring sum

D120 Cone Penetration Tests sum

D130 Field Tests sum

D200 DEEP BORING

Rate to include ground water observation as per


Specification clause (…..…….).

Plant Movement

Shifting of plant and equipment from one borehole


position to the next borehole position, rate to include
dismantling from one position and erecting at another
position where the borehole is to be carried out on:

D211 Flat land. nr

D212 Hillslopes. nr

D213 Floating platform. nr

D214 Fixed platform. nr

D215 Swampy ground. nr

Boring in Soil

Carrying out vertical boring in soil using [rotary wash


boring equipment (NW size)] for depth measured from
Commencing Surface. Rate to include provision of
casing where necessary.

Water [as drilling fluid]

D221.1 Not exceeding 10 m. m

D221.2 10 – 20 m. m

D221.3 20 – 30 m. m

D221.4 30 – 40 m. m

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD20 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D221.5 40 – 50 m. m

D221.6 Exceeding 50 m. m

Water with bentonite or polymer [as drilling fluid]

D222.1 Not exceeding 10 m. m

D222.2 10 – 20 m. m

D222.3 20 – 30 m. m

D222.4 30 – 40 m. m

D222.5 40 – 50 m. m

D222.6 Exceeding 50 m. m

Air/foam [as drilling medium]

D223.1 Not exceeding 10 m. m

D223.2 10 – 20 m. m

D223.3 20 – 30 m. m

D223.4 30 – 40 m. m

D223.5 40 – 50 m. m

D223.6 Exceeding 50 m. m

Drilling in Rock
Carry out vertical diamond core drilling of [52 mm]
diameter into rock including storing of core samples in
standard boxes. [Core boxes shall become property of
the Employer].

Water [as drilling fluid]

D231.1 Not exceeding 10 m. m

D231.2 10 – 20 m. m

D231.3 20 – 30 m. m

D231.4 30 – 40 m. m

D231.5 40 – 50 m. m

D231.6 Exceeding 50 m. m

Air/foam [as drilling medium]

D232.1 Not exceeding 10 m. m

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD21 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D232.2 10 – 20 m. m

D232.3 20 – 30 m. m

D232.4 30 – 40 m. m

D232.5 40 – 50 m. m

D232.6 Exceeding 50 m. m

Reaming casing

D233.1 Not exceeding 10 m. m

D233.2 10 – 20 m. m

D233.3 20 – 30 m. m

D233.4 30 – 40 m. m

D233.5 40 – 50 m. m

D233.6 Exceeding 50 m. m

Grouting

D234.1 Not exceeding 10 m. m

D234.2 10 – 20 m. m

D234.3 20 – 30 m. m

D234.4 30 – 40 m. m

D234.5 40 – 50 m. m

D234.6 Exceeding 50 m. m

Test

Standard penetration test

D241.1 Not exceeding 10 m. nr

D241.2 10 – 20 m. nr

D241.3 20 – 30 m. nr

D241.4 30 – 40 m. nr

D241.5 40 – 50 m. nr

D241.6 Exceeding 50 m. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD22 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

Vane shear test

D242.1 Not exceeding 10 m. nr

D242.2 10 – 20 m. nr

D242.3 20 – 30 m. nr

D242.4 30 – 40 m. nr

D242.5 40 – 50 m. nr

D242.6 Exceeding 50 m. nr

Pressure meter test

D243.1 Not exceeding 10 m. nr

D243.2 10 – 20 m. nr

D243.3 20 – 30 m. nr

D243.4 30 – 40 m. nr

D243.5 40 – 50 m. nr

D243.6 Exceeding 50 m. nr

Field permeability test

D244.1 Not exceeding 10 m. nr

D244.2 10 – 20 m. nr

D244.3 20 – 30 m. nr

D244.4 30 – 40 m. nr

D244.5 40 – 50 m. nr

D244.6 Exceeding 50 m. nr

Dynamic cone test

D245.1 Not exceeding 10 m. nr

D245.2 10 – 20 m. nr

D245.3 20 – 30 m. nr

D245.4 30 – 40 m. nr

D245.5 40 – 50 m. nr

D245.6 Exceeding 50 m. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD23 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

Sampling

Carry out the following sampling in borehole. Rate to


include transportation and protection as per
Specification clause (…………………).

[5 kg] Disturbed samples

D251.1 Not exceeding 10 m. nr

D251.2 10 – 20 m. nr

D251.3 20 – 30 m. nr

D251.4 30 – 40 m. nr

D251.5 40 – 50 m. nr

D251.6 Exceeding 50 m. nr

Undisturbed sample using thin wall tube sampler

D252.1 Not exceeding 10 m. nr

D252.1 10 – 20 m. nr

D252.3 20 – 30 m. nr

D252.4 30 – 40 m. nr

D252.5 40 – 50 m. nr

D252.6 Exceeding 50 m. nr

Undisturbed sample using Mazier sampler

D253.1 Not exceeding 10 m. nr

D253.2 10 – 20 m. nr

D253.3 20 – 30 m. nr

D253.4 30 – 40 m. nr

D253.5 40 – 50 m. nr

D253.6 Exceeding 50 m. nr

Undisturbed sample using piston sampler

D254.1 Not exceeding 10 m. nr

D254.2 10 – 20 m. nr

D254.3 20 – 30 m. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD24 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D254.4 30 – 40 m. nr

D254.5 40 – 50 m. nr

D254.6 Exceeding 50 m. nr

Undisturbed sample using Denison sampler

D255.1 Not exceeding 10 m. nr

D255.2 10 – 20 m. nr

D255.3 20 – 30 m. nr

D255.4 30 – 40 m. nr

D255.5 40 – 50 m. nr

D255.6 Exceeding 50 m. nr

Water sample [minimum 1 litre]

D256.1 Not exceeding 10 m. nr

D256.2 10 – 20 m. nr

D256.3 20 – 30 m. nr

D256.4 30 – 40 m. nr

D256.5 40 – 50 m. nr

D256.6 Exceeding 50 m. nr

Miscellaneous

D261 Borehole marker. nr

D300 CONE PENETRATION TESTS

Plant movement

Shifting of plant and equipment from one test position to


the next test position, rate to include dismantling from
one position and erecting at another position where the
test is to be carried out on:

D311 Flat land. nr

D312 Hillslopes. nr

D313 Floating platform. nr

D314 Fixed platform. nr

D315 Swampy ground. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD25 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

Test

Dutch cone penetration test [using cone type (…) and


(….) kg ram as per Specification clause (….)]

D321.1 Not exceeding 10 m. m

D321.2 10 – 20 m. m

D321.3 20 – 30 m. m

D321.4 30 – 40 m. m

D321.5 40 – 50 m. m

D321.6 Exceeding 50 m. m

Piezocone

D322.1 Not exceeding 10 m. m

D322.2 10 – 20 m. m

D322.3 20 – 30 m. m

D322.4 30 – 40 m. m

D322.5 40 – 50 m. m

D322.6 Exceeding 50 m. m

Dissipation test [maximum 2 hours per test]

D323.1 Not exceeding 10 m. nr

D323.2 10 – 20 m. nr

D323.3 20 – 30 m. nr

D323.4 30 – 40 m. nr

D323.5 40 – 50 m. nr

D323.6 Exceeding 50 m. nr

Miscellaneous

D331 Test location marker. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD26 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D400 FIELD TESTS

Rate for field tests shall be deemed to include plant


movements on site and logging of daily field records.

Hand Auger

Rate for augering in soil shall be deemed to include


ground water observation as per Specification clause
(………………).

D411 Augering in soil. m

D412 Disturbed sample [min. 1 kg]. nr

D413 Undisturbed samples using thin wall tube sampler. nr

D414 Water sample [min. 3 litres]. nr

Trial Pit

Pit size [2 m wide x 2 m long x 2 m deep]. Rate shall be


deemed to include lateral support, logging and mapping
of side wall and backfilling, and ground water
observation as per Specification clause
(…………………).

Rate for sampling shall be deemed to include


transportation and protection as per Specification clause
(…………………..).

D421 Excavation. nr

D422 Small disturbed sample [1 kg]. nr

D423 Bulk sample [min. 50 kg]. nr

D424 Block sample [300 mm x 300 mm]. nr

D425 Water sample [min. 3 litres]. nr

Testing

D431 Mackintosh or JKR probes. m

D432 Vane shear. nr

D433 Plate bearing [300 mm square plate, test pressure 250 nr


kPa with range from uploading and downloading cycle].

D434 In situ CBR at locations as shown in drawings. nr

D435 Pocket penetrometer. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD27 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D436 Field density as per Specification clause (………..). nr

Sampling

Carry out the following sampling at location as indicated


in the drawing. Rate for sampling shall be deemed to
include transportation and protection as per
Specification clause (…………………..).

D441 Small disturbed sample [1 kg]. nr

D442 Bulk sample [min. 50 kg]. nr

D443 Undisturbed samples using thin wall tube sampler. nr

D444 Block sample [300 mm x 300 mm]. nr

D445 Water sample [3 litres]. nr

D500 LABORATORY TESTS

All laboratory tests shall be to [BS 1377:1990], unless


stated otherwise. Rate to include preparation of
specimens.

Classification Test

D511 Mositure content. nr

D512 Atterberg limits. set

D513 Specific gravity. nr

D514 Particle size distribution for fine-grained soils. nr

D515 Particle size distribution for coarse-grained soils. nr

Soil Strength Tests

Each set shall consist of 3 nos. of [50 mm diameter x


100 mm length undisturbed] specimen.

D521 Unconfined compressive strength. nr

D522 Unconsolidated undrained triaxial compression. set

D523 Consolidated undrained triaxial compression test with set


pore water pressure measurement.

D524 Consolidated drained triaxial compression test with pore set


water pressure measurement.

D525.1 [60 mm square] direct shear box test. set

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD28 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D525.2 [100 mm square] direct shear box test. set

D525.3 [300 mm square] direct shear box test. set

D526.1 [60 mm square] multi-reversal shear box test. set

D526.2 [100 mm square] multi-reversal shear box test. set

Soil Compaction Related Tests

Each set shall consist of 5 nos. of specimen.

D531 Standard compaction (2.5 kg hammer). set

D532 Heavy compaction (4.5 kg hammer). set

D533 Vibrating hammer. set

D534 Unsoaked CBR [on both ends]. nr

D535 Soaked CBR [on both ends]. nr

Chemical and Electro-chemical Tests

D541 Organic matter content. nr

D542 Loss on ignition. nr

D543 Total sulphate content. nr

D544 Sulphate content. nr

D545 Chloride content. nr

D546 pH value. nr

D547 Resistivity test. nr

D548 Contaminants […..….] as per [ BS standard]. nr

Rock Strength Tests

D551 Unconfined compressive strength. nr

D552 Unconfined compressive strength with Young's modulus nr


and Poisson's ratio measurement.

D553 Point load test. nr

D554 Petrographic examination as per Specification clause nr


(…………….).

Compressibility and Permeability Tests

D561 One-dimensional consolidation. nr

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD29 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D562 Variable head permeability. nr

D563 Fixed head permeability. nr

D600 INSTRUMENTATION

D610 Piezometer as per Specification clause (…..) and as nr


shown in the drawings. Rate to include pre-boring and
installation.

D620 Inclinometer as per Specification clause (…..) and as nr


shown in the drawings. Rate to include pre-boring and
installation.

D631 Settlement surface marker. nr

D632 Settlement plate as per Specification clause (…..) and as nr


shown in the drawings.

D633 Settlement displacement marker. nr

D640 Magnetic extensometer as per Specification clause nr


(……….).

D650 Deep levelling datum. nr

D660 Monitoring of instrument for the above instrument at the nr


project site by [Geologist] as per Specification clause
(…..……). Rate to include preparation of monitoring
report to be submitted on a [monthly ] basis.

D700 GEOPHYSICAL SURVEY AND MAPPING

Seismic Refraction Survey

D711 Setting out sets of seismic lines, rentising and produce sum
geophone, reduce levels, and topographical profile of
each seismic line using EDM.

D712 Carry out seismic refraction survey with a 24-channel set


seismograph with geophones at intervals of not more
than 5 m measured along the slope, and 7 shots per set,
using sledge hammer as the seismic energy source. Rate
to include data analysis to produce geological profile
incorporating borehole data where available.

D713 Prepare maps of soil isopach and bedrock contour of the sum
Site as per Specification clause (……), based on rock
levels obtained from seismic refraction survey.

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD30 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

Resistivity Profiling

D721 Setting out sets of resistivity profiling, rentising and sum


produce electrodes reduce levels and topographical
profile of each resistivity profile line including
topographical coordinates of each electrode.

D722 Carry out [2D] resistivity profiling using [Schlumberger- set


Wenner configuration and roll-along technique with 40
electrodes at 5-meter intervals], each interval measured
as the slope distance between adjacent electrodes.

D723 Process data for preparation of resistivity profiles. sum

D730 Geological terrain mapping as per Specification clause m2


(….) and in accordance to guidelines by the Minerals
and Geoscience Department, Malaysia, covering area as
shown in the drawings.

Utilities Detection and Mapping

D741 Locate, detect, and map all utilities and services as per m2
Specification clause (...………), for area as shown in
drawings.

D742 Verification with utilities provider. Rate to include sum


purchase of necessary documents and verification on the
utilities detected as compared with the records of the
utilities provider.

D743 Conduct site verification. sum

D800 REPORT

Preliminary Report

D811 Soil investigation report including laboratory test results sum


as per Specification clause (…………) to be submitted
in [two sets] with comb binding.

D812 Seismic refraction survey report as per Specification sum


clause (…………) to be submitted in [two sets] with
comb binding. Rate to include geological sections and
interpretation of data by specialists.

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD31 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

D813 Resistivity profiling report as per Specification clause sum


(…………) to be submitted in [two sets] with comb
binding. Rate to include geological sections and
interpretation of data by specialists.

D814 Geological terrain mapping report as per Specification sum


clause (…………) to be submitted in [two sets] with
comb binding.

D815 Utilities detection and mapping report as per sum


Specification clause (………… ) to be submitted in [two
sets] with comb binding.

Final Report

D821 Soil investigation report including laboratory test results sum


as per Specification clause (…………) to be submitted
in [five sets] in hard cover.

D822 Seismic refraction survey report as per Specification sum


clause (…………) to be submitted in [five sets] in hard
cover.

D823 Resistivity profiling report as per Specification clause sum


(…………) to be submitted in [five sets] in hard cover.

D824 Geological terrain mapping report as per Specification sum


clause (…………) to be submitted in [five sets] in hard
cover.

D825 Utilities detection and mapping report as per sum


Specification clause (…………) to be submitted in [five
sets] in hard cover.

Page Total carried to Summary of Class D

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD32 of BQD173
CLASS D
Site Investigation Work
Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class D: Site Investigation Work

Page BQD1

Page BQD2

Page BQD3

Page BQD4

Page BQD5

Page BQD6

Page BQD7

Page BQD8

Page BQD9

Page BQD10

Page BQD11

Page BQD12

Page BQD13

Total of Class D carried to Grand Summary

Class D: Site Investigation Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQD33 of BQD173
CLASS E
Demolition and Site Clearance

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Items for demolition and site clearance shall be deemed


to include disposal of the materials arising.

E100 GENERAL CLEARANCE

Above Ground

E110.1 General clearance to [primary forest]. Rate to include the ha


removal of trees and stumps, undergrowth, shrubs, roots,
and the likes. [All trees of 0.5 m girth and above shall
become the property of the Employer].

E110.2 General clearance to [palm oil estate]. ha

E120 At water bodies. Rate to include removal and disposal of ha


items as per Specification clause (…..) in or at [Lake
Project] including objects either floating, submerged or
at the bed of the the [lake].

E200 TREES
Felling of trees shall be deemed to include uprooting and
removal of stumps. [All trees of 0.5 m girth and above
shall become the property of the Employer].

E210 Trees of girth: 0.5 ‒ 1 m. nr

E220 Trees of girth: 1 ‒ 2 m. nr

E230 Trees of girth: 2 ‒ 5 m. nr

E240 Trees of girth exceeding 5 m. nr


[Holes after the removal of stumps shall be filled with
granular material].

E300 BUILDING

Concrete

E311 Individual building ‒ [2-storey bungalow with sum


reinforced concrete walls of total gross built-up area of
2000 m2].

E312 Group of buildings ‒ [10 units of single storey chalet sum


with a gross built-up area of 100 m2 each].

Page Total carried to Summary of Class E

Class E: Demolition and Site Clearance


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQE34 of BQE173
CLASS E
Demolition and Site Clearance

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Brickwork and Masonry

E321 Individual building ‒ [single storey bungalow of total sum


gross built‒up area of 200 m2].

E322 Group of buildings ‒ [10 units of single storey chalet sum


with a gross built‒up area of 100 m2 each].

Timber

E331 Individual building ‒ [3 m x 3 m guard house]. sum

E332 Group of buildings ‒ [10 units of single storey chalet sum


with a gross built‒up area of 100 m2 each].

Metal

E341 Individual buildings ‒ [50 m x 10 m steel portal frame sum


factory].

E342 Group of buildings ‒ [2 units of 10 m x 6 m steel stores]. sum

No predominant material

E351 Individual buildings ‒ [single storey reinfoced concrete sum


frame with brick infill and steel roof structure house of
total gross built‒up area of 300 m2].

E352 Group of buildings ‒ [single storey reinfoced concrete sum


frame with brick infill and steel roof structure chalet of
gross built‒up area of 100 m2 each].

E400 STRUCTURES

Concrete

E411 Above ground ‒ [10 m long x 6 m wide x 6 m deep sum


mixing chamber].

E412 Below ground ‒ [Precast concrete box culverts including sum


headwall, wingwall and foundation 20 m long x 3 m
wide x 2 m deep].

Brickwork and Masonry

E421 Above ground ‒ [2 m x 2 m x 3 m high manhole]. sum

E422 Below ground ‒ [2 m x 2 m x 3 m deep manhole]. sum

Timber

E431 Above ground ‒ 3 m x 3 m timber shed. sum

Page Total carried to Summary of Class E

Class E: Demolition and Site Clearance


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQE35 of BQE173
CLASS E
Demolition and Site Clearance

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Metal

E441 Above ground ‒ [2 m x 2 m x 20 m high truss support to sum


cooling tower].

No Predominant Material

E451 Above ground ‒ [10 m long x 6 m wide x 3 m high sum


water tank with timber roof].

E452 Below ground ‒ [10 m x 6 m wide x 5 m deep tank with sum


steel bracing].

E500 PIPELINES
Demolition of pipelines shall be deemed to include
demolition and removal of supports.

E510 [Dismantle 400 mm DN elevated mild steel pipeline]. m


The pipeline shall become the property of the Employer
and shall be delivered to the store at (…….).

Page Total carried to Summary of Class E

Class E: Demolition and Site Clearance


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQE36 of BQE173
CLASS E
Demolition and Site Clearance

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class E: Demolition and Site Clearance

Page BQE1

Page BQE2

Page BQE3

Total of Class E carried to Grand Summary

Class E: Demolition and Site Clearance


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQE37 of BQE173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

F100 EXCAVATION

Stripping

F111.1 Topsoil of average depth of 150 mm and disposed to the m2


Contractor's dumpsite as approved by the
Engineer/S.O./P.D.

F111.2 Topsoil of average depth of 150 mm and stockpile for re- m2


use as top soil for turfing.

Cut to Fill

Excavation in cut shall be deemed to include trimming


and preparation of excavated surface and transportation
from source to place of fill or disposal.

F121.1 Excavate in earth material from original ground level [to m3


form embankment].

F121.2 Excavate in earth material commencing from [104 m] m3


[to form embankment].

F121.3 Excavate manually in earth material commencing from m3


[104 m] to [103.5 m].

F122 Excavate in natural hard material to form embankment. m3

F123.1 Excavate in rock material by open blasting [to form m3


embankment].

F123.2 Excavate in rock material by controlled blasting [to form m3


embankment].

F123.3 Excavate in rock material by hydraulic rock breaker [to m3


form embankment].

F123.4 Excavate in rock material by pneumatic tools [to form m3


embankment].

Cut and Dispose

Excavation in cut shall be deemed to include trimming


and preparation of excavated surface and transportation
from source to place of fill or disposal.

F131.1 Excavate in earth material commencing from [104 m] to m3


[100 m] to disposal site approved by the
Engineer/S.O./P.D.

Page Total carried to Summary of Class F

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF38 of BQF173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

F131.2 Excavate in earth material commencing from [104 m] to m3


[100 m] to disposal site approved by the
Engineer/S.O./P.D. [Rate to include compaction at
disposal site].

F132 Excavate in natural hard material by ripper unit m3


commencing from [104 m] to [100 m] to disposal site
approved by the Engineer/S.O./P.D.

F133.1 Excavate in rock by controlled blasting commencing m3


from [104 m] to [100 m] to disposal site approved by the
Engineer/S.O./P.D.

F133.2 Excavate in rock by open blasting commencing from m3


[104 m] to [100 m] to disposal site approved by the
Engineer/S.O./P.D.

F134 Excavate in artificial hard material by hydraulic rock m3


breaker to disposal site approved by the
Engineer/S.O./P.D.

F135 Excavate in unsuitable material commencing from [104 m3


m] to [103 m] to disposal site approved by the
Engineer/S.O./P.D.

Foundation

Excavation for foundation shall include upholding sides


of excavation, preparation of excavated surface,
additional excavation to provide working space and
removal of dead services.

F141 Excavate in earth material commencing from level [104 m3


m] to [102 m] to [clear water tank].

F142 Excavate in natural hard material using ripper unit m3


commencing from level [104 m] to [102 m] to [raft
foundation for chemical building].

F143 Excavate in rock using [hydraulic rock breaker] m3


commencing from level [104 m] to [101 m] to [raft
foundation for treated water pumping station].

F144 Excavate in artificial hard material at [TNB sub-station]. m3

F145 Excavate in unsuitable material commencing from level m3


[102 m] to [101 m] at [clear water tank].

F150 Excavate under water at Sg. (…) from river bed level of m3
[54 m] to [52 m]. Rate shall include all necessary
temporary work.

Page Total carried to Summary of Class F

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF39 of BQF173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

F161 Provision of plant and equipment for dredging work at sum


Sg. (….). Rate to include mobilisation and
demobilisation.

F162 Excavation by dredging at Sg. (…..) to limits as shown m3


in Drawing No. (……). Rate shall include transportation
from source to place of disposal and mopping up of silt
which accumulates after the Final Surface has been
reached.

F200 EXCAVATION ANCILLARIES

Double Handling of Excavated Material

F211 In earth material to temporary stockpile approved by the m3


Engineer/S.O./P.D.

F212 In natural hard material to temporary stockpile approved m3


by the Engineer/S.O./P.D.

F213 In rock to temporary stockpile approved by the m3


Engineer/S.O./P.D.

F214 In artificial hard material to temporary stockpile before m3


final disposal.

F230 Timber support left-in. m2

F240 Metal support left-in. m2

F300 FILLING

The following items for filling shall include compaction,


and additional filling necessitated by settlement or
penetration into underlying material as applicable.

General

F311 Using suitable excavated material to grading limits as m3


per Specification clause (……).

F312.1 Imported material from Contactor's own source with m3


grading limits as per Specification clause (…..).

F312.2 Imported material from borrow pit as shown in the m3


drawing with grading limits as per Specification clause
(…..).

F313 Grade C20 mass concrete. m3

Page Total carried to Summary of Class F

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF40 of BQF173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

F314 Other stated material – granular material as per m3


Specification clause (…..).

Embankments

F321 Using suitable excavated material to grading limits as m3


per Specification clause (……) to form embankment.
Rate to include formation of benches.

F322 Imported material from Contactor's own source with m3


grading limits as per Specification clause (…..) to form
embankment. Rate to include formation of benches.

F323 Grade C20 mass concrete. m3

F324 Other stated material – granular material as per m3


Specification clause (…..) to form drainage layer to
embankment.

Replacement

F331 Replace unsuitable material using excavated material. m3

F332 Replace unsuitable material using imported material m3


from Contactor's own source.

F333 Replace excavated unsuitable material with Grade C20 m3


mass concrete.

F334 Other stated material – granular material as per m3


Specification clause (…..) to replace unsuitable material.

F340.1 To structures – filling around column stumps. m3

F340.2 To structures – filling sides of wall above raft m3


foundation.

F350 Filling to embankment at Sg. (….) below water level. m3

F400 FILLING ANCILLARIES

F410 [Continuous polypropylene filament, nonwoven] m2


geotextile with tensile strength of 19 kN/m, effective
opening size of 0.09mm and nominal mass of 250 g/m2
as per Specification clause (….).

Page Total carried to Summary of Class F

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF41 of BQF173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

F500 LANDSCAPING

Items for landscaping shall be deemed to include


digging, planting media, bedding, stalking, protection,
watering, weeding, required fertilising, and replacement
of dead item until the vegetation is established.

F510.1 Spot turfing to flat areas. m2

F510.2 Close turfing to slopes. Rate to include pegging down m2


with stakes.

F520.1 Hydroseeding as per Specification clause (….). m2

F520.2 Hydroseeding with fibromat or equivalent. m2

F530 Bio-degradable erosion control blanket to slope of m2


embankment with fastening hook at […mm] spacing.
Rate to include fastening hook and netting.

F540 Vertiver grass or equivalent at 250 mm spacing (in m


group of 3 rows).

F550 Trees of the (….) species with minimum girth of [200 nr


mm] and [3 m] tall.

Page Total carried to Summary of Class F

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF42 of BQF173
CLASS F
Earthworks

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class F: Earthworks

Page BQF1

Page BQF2

Page BQF3

Page BQF4

Page BQF5

Total of Class F carried to Grand Summary

Class F: Earthworks
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQF43 of BQF173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

G100 PLANT AND EQUIPMENT

G110 Provision of all necessary plant and equipment, sum


transportation to the Site, handling, assembling, and
removal off the Site after completion of operation.

G120 Moving and handling all necessary plant and equipment sum
within the Site and from location to location as often as
is and whenever necessary for the execution of whole
operation.

G130 Temporary staging. sum

G200 RETAINING STRUCTURES

Gabion

G211.1 [1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVC- m3


coated wire gauge size of [2.7 mm] as per Specification
clause (….) and as shown in the drawings.

G211.2 [2.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVC- m3


coated wire gauge size of [2.7 mm] as per Specification
clause (….) and as shown in the drawings.

G211.3 [1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVC- m3


coated wire gauge size of [2.7 mm] as per Specification
clause (….) and as shown in the drawings. Rate to
include for laying underwater.

G212 Rock-filled gabion mattress, [300 mm] thick with PVC- m2


coated wire gauge size of [2.7 mm] as per Specification
clause (….) and as shown in Drawing No. (....).

G213 Non-woven geotextile as separator as per Specification m2


clause (….).

Cribwall

Item for cribwall shall be deemed to include precast


reinforced concrete (Grade 30) components and granular
infill material as per Specification clause (….).

G221 Single cell with [1200 mm] header as shown in Drawing m2


No. (….).

G222 Double cell with [1200 mm + 1200 mm] header as m2


shown in Drawing No. (…..).

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG44 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

G223 Triple cell with [1650 mm + 1650 mm + 1200 mm] m2


header as shown in Drawing No. (…….).

G224 Quadruple cell with [1200 mm + 1200 mm + 1200 mm m2


+ 1200 mm] as shown in Drawing No. (……..).

G225 Non-woven geotextile as separator as per Specification m2


clause (….).

Reinforced Soil Slope

G231 Woven geotextile with minimum long term design m2


strength of [100 kN/m] as soil reinforcement as per
Specification clause (….).

G232 Geogrid with minimum long term design strength of [75 m2


kN/m] as soil reinforcement as per Specification clause
(….).

G233 Reinforced earth filling as per Specification clause (….) m3


and as shown in Drawing No. (….).

G234 Reinforced granular filling as per Specification clause m3


(….) and as shown in Drawing No. (….).

G235 [HDPE] erosion protection mats with minimum tensile m2


strength of [1.4 kN/m] as per Specification clause (….).

Reinforced Soil Wall

[Precast reinforced concrete wall facing panels], rate to


include galvanised steel soil reinforcement, connections
and jointing, geotextile, and accessories for wall joints
for wall height:

G241.1 Not exceeding 6 m. m2

G241.2 Exceeding 6 m but not exceeding 9 m. m2

G241.3 Exceeding 9 m but not exceeding 12 m. m2

G241.4 Exceeding 12 m but not exceeding 15 m. m2

G242 Reinforced earth filling as per Specification clause (….). m3

G243 Reinforced granular filling as per Specification clause m3


(….).

G244 [350 mm wide x 150 mm thick G20 mass concrete] m


leveling pad.

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG45 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

G245 Pull out test, rate to include all necessary equipment and nr
submission of procedure, records, and report.

G300 SLOPE STABILISATION

Soil Nailing

Rate for soil nailing shall be deemed to include drilling


of borehole, corrugated HDPE pipe if applicable, sleeve
grouting, sealant compound, galvanised steel bearing
plate, and all necessary formwork.

[100 mm dia.] soil nail with [T25] reinforcement bar as


shown in Drawing No. (....).

G311.1 [6 m] long. nr

G311.2 [9 m] long. nr

G311.3 [12 m] long. nr

Pull out test on soil nail, rate to include all necessary


equipment and submission of procedure, records, and
report.

G312.1 To [1.5] times the working load of 50 kN. nr

G312.2 To [1.5] times the working load of 75 kN. nr

G312.2 To [1.5] times the working load of 100 kN. nr

Rock Bolt

Rate for rock bolt shall be deemed to include drilling of


borehole, reinforcement bar, reinforced concrete pad,
sleeve grouting, sealant compound, and all necessary
formwork.

Type A with T32 bolt as shown in Drawing No. (….).

G321.1 [2 m] long. nr

G321.2 [4 m] long. nr

G322 Pull out test on rock bolt as specified, rate to include all nr
necessary equipment and submission of procedure,
records, and report.

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG46 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Ground Anchor

Rate for ground anchor shall be deemed to include


prestressed tendons, drilling, grouting, concreting, and
all necessary formwork.

[Type 1] ground anchor as shown in Drawing No. (….).

G331 In earth. m

G332 In natural hard material. m

G333 In rock. m

G334 Pull out test on ground anchor as per Specification nr


clause (….), rate to include all necessary equipment and
submission of procedure, records, and report.

Concrete Buttress

Rate for concrete buttress shall be deemed to included


steel fabric mesh, PVC drain pipe, dowel bars, filter
material, and all necessary formworks.

G340.1 [G25] concrete buttress with average thickness [not m2


exceeding 300 mm].

G340.2 [G25] concrete buttress with average thickness m2


[exceeding 300 mm but not exceeding 400 mm].

Horizontal Drain

Rate for horizontal drain shall be deemed to include


drilling and perforated pipe.

[100 mm] diameter uPVC horizontal drain as shown in


Drawing No. (….).

G351 In earth. m

G352 In rock. m

G400 SURFACE PROTECTION

G410 [100 mm] thick [G25] guniting. Rate shall be deemed to m2


include steel fabric mesh, PVC drain pipe, dowel bar,
and filter material as shown in Drawing No. (….).

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG47 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

G420 [150 mm thick] concrete articulating slab as per m2


Specification clause (….) and as shown in Drawing No.
(....). Rate to include prepartion of surface, blinding,
aggregate, geotextile, and all necessary concrete and
formwork.

G430 Rock netting with PVC-coated wire gauge size of [2.7 m2


mm] as per Specification clause (….). Rate to include all
necessary accessories.

G440 [250 mm] thick stone pitching as per Specification m2


clause (….).

G450 [250 mm] thick stone revetment as per Specification m2


clause (….).

G500 GROUND TREATMENT

G510 [100 mm x 3 mm] prefabricated vertical drains as per m


Specification clause (…………).

G520 Dynamic compaction using [10 tonne] drop hammer nr


with [five] drops at height of 15 m.

G530 Vibro compaction up to depth of [10 m] as per Drawing nr


No (….)

G540 1000 mm diameter sand column as per Specification m


clause (….).

G550 1000 mm diameter aggregate column as per m


Specification (….).

G560 1000 mm diameter stone column as per Specification m


(….).

G570 1000 mm diameter cement column as per Specification m


(….).

G600 GROUTING WORK

Drilling for [50 mm] diameter grout holes for depth not
exceeding [10 m] in:

G611 Earth. m

G612 Rock; rate to include drilling in natural and artificial m


hard material.

G620 uPVC sleeve pipes for [50 mm] diameter grout hole. m
Rate to include grouting of annulus space between the
sleeve pipe and the drill holes.

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG48 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grout Injection

Grout mixed components:

G631 Cement. t

G632 Sand. t

G633 Bentonite. t

G634 Aluminium powder. kg

Connection for grouting for the following. Rate to


include provision of packer as expressly required.

G640.1 Ascending stage with single packer setting. nr

G640.2 Descending stage with double packer setting. nr

G650 Water pressure test as per Specification clause (….). nr

G700 DIAPHGRAGM WALLS

Excavation
Excavation for [1.2 m] thick diaphragm wall not
exceeding depth 15 m for the following. Rate to include
preparation and upholding sides of excavation.

G711 Earth. m3

G712 Natural hard material. m3

G713 Rock. m3

G714 Artificial hard material. m3

G720 [Grade C40] tremie mix concrete. m3

Reinforcement, Rate To Include Labour for Cutting,


Bending and Placing

Mild steel bar reinforcement

G731.1 Nominal diameter: [10 mm]. t

G731.2 Nominal diameter: [12 mm]. t

High tensile steel bar reinforcement

G732.1 Nominal diameter: [12 mm]. t

G732.2 Nominal diameter: [16 mm]. t

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG49 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

G732.3 Nominal diameter: [20 mm]. t

G732.4 Nominal diameter: [25 mm]. t

G732.5 Nominal diameter: [32 mm]. t

G740 Waterproofed joints. sum

G750 Guide walls. m

G760 Preparing top of walls to receive cappings as per m


Specification clause (….).

G770 Preparing cast in pockets or chases as shown in Drawing m


No. (....).

Page Total carried to Summary of Class G

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG50 of BQG173
CLASS G
Geotechnical Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class G: Geotechnical Work

Page BQG1

Page BQG2

Page BQG3

Page BQG4

Page BQG5

Page BQG6

Page BQG7

Total of Class G carried to Grand Summary

Class G: Geotechnical Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQG51 of BQG173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

H100 PLANT AND EQUIPMENT

H110 Provision of all necessary piling plant and equipment, sum


transportation to the Site, handling, assembling, and
removal off the Site after completion of operation.

H120 Moving and handling of all piling plant and equipment sum
within the Site and from location to location as often as
is, and whenever necessary for the execution of the
whole piling operation.

H130 Temporary staging [for piling work at the banks of Sg. sum
(…..)].

H200 PILES

Items for piling work shall be deemed to include piling


records and disposal of excavated and surplus materials.

Bored Piles

Items for bored piles shall be deemed to include


temporary casings, stabilising agent, and enlarged bases.

[900 mm] diameter bored piles as working piles.

H211.1 Boring in earth, up to [20 m] for [50] nos. of pile points. m

H211.2 Boring in earth, raked at inclination of ratio [1:5] for m


[10] nos. of pile points.

H212.1 Boring through rock, up to [10 m] for [50] nos. of pile m


points. Rate to include natural and artificial hard
material.

H212.2 Boring through rock and raked at inclination ratio of m


[1:6] for [10] nos. of pile points. Rate to include natural
and artificial hard material.

H213 [12 mm] thick mild steel permanent casings. Rate to m


include the supply and jointing of casings, driving
heads, and shoes.

H214 High tensile reinforcement straight bars, nominal t


diameter not exceeding 20 mm. Rate to include
supporting reinforcement.

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH52 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

H215 High tensile reinforcement straight bars, nominal t


diameter exceeding 20 mm. Rate to include supporting
reinforcement.

H216 High tensile reinforcement helical bars, nominal t


diameter exceeding 20 mm.. Rate to include supporting
reinforcement.

H217 Concreted length with grade [C40/20]. m

H218 Cut-off piles. Rate to include preparing heads. nr

Driven Cast In situ Concrete Piles

[900 mm] diameter cast in situ concrete piles as


working piles.

H221 Drive [12 mm] thick mild steel casing in earth for [50] m
nos. of pile points. Rate to include pre-boring.

H222 Boring through rock. Rate to include natural and m


artificial hard material.

Reinforcement straight bars nominal diameter:

H224 High tensile reinforcement straight bars, nominal t


diameter not exceeding 20mm. Rate to include
supporting reinforcement.

H225 High tensile reinforcement straight bars, nominal t


diameter exceeding 20 mm. Rate to include supporting
reinforcement.

H226 High tensile reinforcement 12 mm diameter helical bars. t


Rate to include supporting reinforcement.

H227 Concreted length with grade [40/20]. m

H228 Cut-off piles. Rate to include preparing heads. nr

Caisson Piles

[2500 mm] diameter caisson piles as working piles.

H231 Excavate in earth, up to [20 m] for [25] nos. of pile m


points.

H232 Excavate through rock, up to [10 m] for [25] nos. of pile m


points. Rate to include natural and artificial hard
material.

H233 [20 mm] thick mild steel permanent casings. Rate to m


include the supply and jointing of casings, driving
heads, and shoes.

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH53 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

H234 High tensile reinforcement straight bars, nominal t


diameter not exceeding 20 mm. Rate to include
supporting reinforcement.

H235 High tensile reinforcement straight bars, nominal t


diameter exceeding 20 mm. Rate to include supporting
reinforcement.

H236 High tensile reinforcement helical bars. Rate to include t


supporting reinforcement.

H237 Concreted length with grade [C40/20]. m

Micropiles

[200 mm] diameter micropiles as working piles.

H241 Boring in earth, up to [20 m] for [30] nos. of pile points. m

H242 Boring through rock, up to [10 m] for [30] nos. of pile m


points. Rate to include natural and artificial hard
material.

H243 Supply and install [127 mm OD x 9 mm thick Grade N- m


80 API pipe].

H244 High tensile reinforcement straight bars, nominal t


diameter not exceeding 20 mm. Rate to include
supporting reinforcement.

H245 High tensile reinforcement straight bars, nominal t


diameter exceeding 20 mm. Rate to include supporting
reinforcement.

H246 High tensile reinforcement helical bars. Rate to include t


supporting reinforcement.

H247 Grouting with non-shrink cement grout Grade [C30] as m3


specified into drilled hole. Rate shall include excess
cement required when the grout volume exceeded the
theoretical volume.

H248 Cut-off piles. Rate to include preparing heads. nr

Precast Reinforced Concrete Piles

[200 mm] G40 square precast reinforced concrete piles


with a working load of [….] kN.

H251.1 Supply initial piles with rock shoes of [12 m] length. nr

H251.2 Supply extension piles of [9 m] length. nr

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH54 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

H252.1 Depth driven. m

H252.2 Depth driven raked at inclination ratio of [1:6]. m

H252.3 Depth driven using jack-in method. m

H253 Pre-boring, [18.0 m] depth. Rate to include backfilling m


between the pile and the bore.

H254 Jointing with butt weld all round as shown in Drawing nr


No. (….).

H256 Cut-off piles. Rate to include preparing heads. nr

Precast Prestressed Concrete Piles

[600 mm] diameter spun piles with a working load of


[….] kN.

H261.1 Supply initial pile with rock shoes of [12 m] length. nr

H261.2 Supply extension pile of [9 m] length. nr

H262.1 Depth driven. m

H262.2 Depth driven raked at inclination ratio of [1:6]. m

H262.3 Depth driven using jack-in method. m

H263 Pre-boring, [18.0 m] depth. Rate to include backfilling m


between the pile and the bore.

H264 Jointing with butt weld all round as shown in Drawing nr


No. (….).

H265 Filling hollow piles with concrete grade [C30]. Rate to m


include removal of materials from within the piles before
concreting.

H266 Cut-off piles. Rate to include preparing heads. nr

Steel H-Piles

533 mm x 210 mm x 138 kg/m UB Grade 43A.

H271 Supply of steel H-piles with metal-filled primers of [6 m] nr


length. Rate to include cathodic protection using the
impressed current system as per Specification clause
(…..).

H272.1 Depth driven. m

H272.2 Depth driven raked at inclination ratio of [1:6]. m

H272.3 Depth driven using jack-in method. m

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH55 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

H273 Jointing with welded splice plates as shown in Drawing nr


No. (…..).

H274 Cut-off piles. Rate to include preparing heads. nr

Steel Pipe Piles

[323.9 OD x 10 mm thick x 77.4 kg/m] mild steel pipe


piles Grade 43A.

H281 Supply of steel pipe piles with metal-filled primers of [9 nr


m] length. Rate to include cathodic protection using the
sacrificial anode system as per Specification clause
(…..).

H282.1 Depth driven. m

H282.2 Depth driven raked at inclination ratio of [1:6]. m

H282.2 Depth driven using jack-in method. m

H283 Jointing with butt weld all round as shown in Drawing nr


No. (….).

H284 Cut-off piles. Rate to include preparing heads. nr

H300 PILES

Timber Piles

[150 mm square] Grade B, Kempas timber piles pressure


treated with CCA.

H311 Supply in [12 m] length. nr

H312.1 Depth driven. m

H312.2 Depth driven raked at inclination ratio of [1:6]. m

H312.3 Depth driven using jack-in method. m

H313 Jointing using mild steel welded boxes [450 mm] long nr
fabricated from 5 mm thick plates.

H314 Cut-off piles. Rate to include preparing heads. nr

Precast Prestressed Concrete Sheet Piles

[996 mm wide x 325 mm high x 110 mm thick] with


cross section area of 1315 cm2 precast pretressed
concrete sheet piles.

H321 Supply in [12 m] length. nr

H322 Depth driven. m2

H323 Cut-off piles. Rate to include preparing heads. m

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH56 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Interlocking Steel Sheet Piles

Interlocking Grade 43A steel sheet piles, [Z-section] , at


66.1 kg/m, section modulus of 1200 cm³/m.

H331 Supply in [12 m] length. m

H332 Depth driven. m2

H333 Special piles for 90o corners with mass of 14.4 kg/m. m

H334 Cut-off piles. Rate to include preparing heads. m

H335 305 mm x 165 mm x 54 kg/m Grade 43A universal m


beam as waling. Rate to include supply and installation.

H336 [Type 1] ground anchor as shown in Drawing No. (….). nr

H400 MISCELLANEOUS WORK

Obstructions

H411 Excavation through obstructions for [900 mm diameter m


bored piles].

H500 PILE TESTS

H510.1 Initial static load test on 900 mm diameter bored pile up nr


to two times working load of 16,000 kN.

H510.2 Subsequent static load test, on 900 mm diameter bored nr


pile up to two times working load of 16,000 kN (Test
load of 32,000 kN).

H510.3 Static load test on preliminary 300 mm diameter precast nr


prestressed concrete pile to failure (Test load of ….kN).

H520 PDA test on [300 mm] diameter prestressed concrete nr


pile.

H530 Pile integrity test (sonic echo test) on [300 mm] diameter nr
prestressed concrete pile.

H540 Sonic logging test on 900 mm diameter bored piles as nr


per Specification clause (….).

H550 Lateral test on [300 mm] diameter prestressed concrete nr


pile.

H560 Statnamic test on [300 mm] diameter prestressed nr


concrete pile.

Page Total carried to Summary of Class H

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH57 of BQH173
CLASS H
Piling Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class H: Piling Work

Page BQH1

Page BQH2

Page BQH3

Page BQH4

Page BQH5

Page BQH6

Total of Class H carried to Grand Summary

Class H: Piling Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQH58 of BQH173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I100 IN SITU CONCRETE DESIGN MIX

Rate for in situ concrete designed mix shall be deemed


to include placing and compaction of concrete.

Grade C15 Concrete

I111.1 Mass concrete blinding, [50 mm] thick [to footing]. m2

I111.2 Mass concrete blinding, [50 mm] thick [to raft m2


foundation].

I112 Mass concrete benching to sumps. m3

Grade: C20

I121 Mass concrete blinding, [75 mm] thick [to clear water m2
tank].

I122.1 Mass concrete benching to sumps. m3

I122.2 Mass concrete benching to trenches. m3

I122.3 Mass concrete surround to pipes. m3

I122.4 Mass concrete screed to fall for roof. m3

Grade: C25

I132.1 Reinforced concrete to base of [valve chamber]. m3

I132.2 Reinforced concrete to footing of [guard house]. m3

I132.3 Reinforced concrete to pile caps of [workshop]. m3

I132.4 Reinforced concrete to ground slab to [store]. m3

I133 Reinforced concrete to olumns of [guard house]. m3

I134 Reinforced concrete beams to [workshop]. m3

I135 Reinforced concrete to walls of [valve chambers]. m3

I136 Reinforced concrete to suspended slabs [at first floor of m3


workshop].

I137 Other concrete forms, reinforced concrete to [steps and m3


staircase].

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI59 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grade: C30

I142.1 Reinforced concrete base to [trenches]. m3

I142.2 Reinforced concrete footings to [Administration m3


Building].

I142.3 Reinforced concrete pile caps to [Workshop]. m3

I142.4 Reinforced concrete ground slab to [Workshop]. m3

I143 Reinforced concrete columns to [Administration m3


Building].

I144 Reinforced concrete beams to [Administration m3


Building].

I145 Reinforced concrete walls to [trenches]. m3

I146 Reinforced concrete to suspended slabs [at first floor of m3


workshop].

I147 Other concrete forms, reinforced concrete to [steps and m3


staircase].

Grade: C35

I152.1 Reinforced concrete base to [elevated water tank]. m3

I152.2 Reinforced concrete to footings [of TNB sub-station]. m3

I152.3 Reinforced concrete pile caps. m3

I152.4 Reinforced concrete ground slabs. m3

I153.1 Reinforced concrete to columns for [Chlorine Building]. m3

I153.2 Reinforced concrete to piers for [pedestrian brudge]. m3

I154 Reinforced concrete beams to [pedestrian bridge]. m3

I155 Reinforced concrete walls to [bridge abutment]. m3

I156 Reinforced concrete suspended slabs to [bridge deck]. m3

I157 Other concrete forms. m3

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI60 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grade: C35A

I162 Reinforced concrete bases to [clear water tank]. m3

I163 Reinforced concrete columns to [clear water tank]. m3

I164 Reinforced concrete beams [to support static mixer]. m3

I165 Reinforced concrete walls to [clear water tank]. m3

I166 Reinforced concrete suspended [flat] slabs to [roof of m3


clear water tank].

I167 Other concrete forms – mass concrete benching to m3


[washwater channel].

Grade: C40

I172.1 Reinforced concrete bases. m3

I172.2 Reinforced concrete footings. m3

I172.3 Reinforced concrete pile caps. m3

I172.4 Reinforced concrete ground slabs. m3

I173.1 Reinforced concrete columns. m3

I173.2 Reinforced concrete piers. m3

I174 Reinforced concrete beams. m3

I175 Reinforced concrete walls. m3

I176 Reinforced concrete suspended slabs. m3

I177 Other concrete forms. m3

Grade: C50

I182.1 Reinforced concrete bases. m3

I182.2 Reinforced concrete footings. m3

I182.3 Reinforced concrete pile caps. m3

I182.4 Reinforced concrete ground slabs. m3

I183.1 Reinforced concrete columns. m3

I183.2 Reinforced concrete piers. m3

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI61 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I184 Reinforced concrete beams. m3

I185 Reinforced concrete walls. m3

I186 Reinforced concrete suspended slabs. m3

I187 Other concrete forms. m3

I200 IN SITU CONCRETE PRESCRIBED MIX

Rate for in situ concrete prescribed mix shall be deemed


to include placing and compaction of concrete.

1:3:6

I211 Mass concrete blinding, [50 mm] thick [to footing]. m2

I212 Mass concrete benching to sumps. m3

1:2:4

I221 Mass concrete blinding, [75 mm] thick [to clear water m2
tank].

I222.1 Mass concrete benching to sumps. m3

I222.2 Mass concrete benching to trenches. m3

I222.3 Mass concrete surround to pipes. m3

I222.4 Mass concrete screed to fall for roof. m3

I223 Reinforced concrete columns. m3

I224 Reinforced concrete beams. m3

I225 Reinforced concrete walls. m3

I226 Reinforced concrete suspended slabs. m3

I227 Other concrete forms. m3

1:1.5:3

I232.1 Reinforced concrete base to [trenches]. m3

I232.2 Reinforced concrete footings to [Administration m3


Building].

I232.3 Reinforced concrete pile caps to [Workshop]. m3

I232.4 Reinforced concrete ground slab to [Workshop]. m3

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI62 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I233 Reinforced concrete columns to [Administration m3


Building].

I234 Reinforced concrete beams to [Administration m3


Building].

I235 Reinforced concrete walls to [trenches]. m3

I236 Reinforced concrete to suspended slabs [at first floor of m3


workshop].

I237 Other concrete forms, reinforced concrete to [steps and m3


staircase].

1:1:2

I242.1 Reinforced concrete base to [elevated water tank]. m3

I242.2 Reinforced concrete to footings [of TNB sub-station]. m3

I242.3 Reinforced concrete pile caps. m3

I242.4 Reinforced concrete ground slabs. m3

I243 Reinforced concrete to columns for [Chlorine Building]. m3

I244 Reinforced concrete beams to [pedestrian bridge]. m3

I245 Reinforced concrete walls to [bridge abutment]. m3

I246 Reinforced concrete suspended slabs to [bridge deck]. m3

I247 Other concrete forms. m3

I300 PRECAST CONCRETE

Item for precast concrete shall be deemed to include


reinforcement, formwork, joints, and finishes; and items
for prestressed precast units shall include prestressing.

I310.1 [Grade C35] [400 mm x 300 mm x 4 m long] columns to nr


first floor.

I310.2 [Grade C45] columns with dimension as shown in nr


Drawing No. (…) to mezzanine floor.

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI63 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I320 [Grade 45] [600 mm x 300 mm x 6 m long] beams to nr


first floor.

I330 [Grade 45] prestressed pre-tensioned main beam, [ I- nr


section 800 mm x 1400 mm x 22 m long] as per
Drawing No. (…..) and Specification clause (……).

I340 [Grade 45] Prestressed post-tensioned main beam,[ T- nr


section 800 mm x 1400 mm x 22 m long] as per
Drawing No. (…..) and Specification clause (……).

I350 [Grade 35], 6 m x 3 m x 150 mm thick walls to the first nr


floor up to the fourth floor.

I360 [Grade 35] [half] slab, [3 m x 2 m x 75 mm thick] to the nr


first floor.

I370 Segmental units with dimensions as shown in Drawing nr


No. (……)

I380 Units for subways and vehicular or pedestrian culverts m


and ducts with dimensions as shown in Drawing No.
(….)

I400 FORMWORK

Rate for formwork shall be deemed to include the


projections and intrusions and any temporary staging
required.

Sides

I411.1 F1: rough finish to bases. m2

I411.2 F1: rough finish to footings. m2

I411.3 F1: rough finish to pile caps. m2

I411.4 F1: rough finish to ground slabs. m2

I412.1 F2: fair finish to columns. m2

I412.2 F2: fair finish to piers. m2

I412.3 F3: smooth finish to columns. m2

I412.4 F3: smooth finish to piers. m2

I413.1 F2: fair finish to beams. m2

I413.2 F3: smooth finish to beams. m2

I414.1 F2: fair finish to walls. m2

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI64 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I414.2 F3: smooth finish to walls. m2

I414.3 F3: smooth finish to walls, curved on plan. m2

Soffit

I425.1 F2: fair finish to suspended slabs. m2

I425.2 F3: smooth finish to suspended slabs. m2

I425.3 F3: smooth finish to curved roof slabs. m2

Sides and Soffit

I433.0 F2: fair finish to beams. m2

I433.0 F3: smooth finish to beams. m2

Sloping

I441 F2: fair finish to upper surface to base, [height 0.3 – 0.5 m2
m].

I442 F2: fair finish to columns, [0.3 – 0.4 m]. m2

I444 F3: smooth finish to walls, [width 0.6 m – 0.3 m]. m2

For Voids

I451 [300 x 300 x 150 mm deep] opening. nr

I452 [1 m x 2 m x 1.5 m deep] opening in wall. m2

I500 REINFORCEMENT

Rate for reinforcement shall be deemed to include labour


for cutting, bending, and placing.

Mild Steel Bars

I511 Nominal diameter: 6 mm. t

I512 Nominal diameter: 10 mm. t

I513 Nominal diameter: 12 mm. t

I514 Nominal diameter: 16 mm. t

I515 Nominal diameter: 20 mm. t

I516 Nominal diameter: 25 mm. t

I517 Nominal diameter: 32 mm. t

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI65 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I518 Nominal diameter: larger than 40 mm. t

High Tensile Bars

I521 Nominal diameter: 6 mm. t

I522 Nominal diameter: 10 mm. t

I523 Nominal diameter: 12 mm. t

I524 Nominal diameter: 16 mm. t

I525 Nominal diameter: 20 mm. t

I526 Nominal diameter: 25 mm. t

I527 Nominal diameter: 32 mm. t

I528 Nominal diameter: larger than 40 mm. t

Reinforcing Bars of Other Stated Material

I531 Nominal diameter: 6 mm. t

I532 Nominal diameter: 10 mm. t

I533 Nominal diameter: 12 mm. t

I534 Nominal diameter: 16 mm. t

I535 Nominal diameter: 20 mm. t

I536 Nominal diameter: 25 mm. t

I537 Nominal diameter: 32 mm. t

I538 Nominal diameter: larger than 40 mm. t

I540.1 Special joints using [500 mm long] mechanical grip nr


sleeve as per Specification clause (…) to [20 mm
nominal diameter high tensile bars].

I540.2 Special joints using [600 mm long sleeve filled with nr


epoxy] as per Specification clause (….) to [20 mm
nominal diameter high tensile bars].

I550.1 High tensile steel fabric – mesh A98 (A4), 1.54 kg/m2. m2

I550.2 High tensile steel fabric – mesh A142 (A5), 2.22 kg/m2. m2

I550.3 High tensile steel fabric – mesh A193 (A7), 3.02 kg/m2. m2

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI66 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I550.4 High tensile steel fabric – mesh A252 (A8), 3.95 kg/m2. m2

I550.5 High tensile steel fabric – mesh A393 (A10), 6.16 m2


kg/m2.

I550.6 High tensile steel fabric – mesh B196 (B5), 3.05 kg/m2. m2

I550.7 High tensile steel fabric – mesh B283 (B6), 3.73 kg/m2. m2

I550.8 High tensile steel fabric – mesh B385 (B7), 4.53 kg/m2. m2

I550.9 High tensile steel fabric – mesh B503 (B8), 5.93 kg/m2. m2

I550.10 High tensile steel fabric – mesh B785 (B10), 8.14 m2


kg/m2.

I550.11 High tensile steel fabric – mesh B1131 (B12), 10.90 m2


kg/m2.

I550.12 High tensile steel fabric – mesh C283 (C6), 2.61 kg/m2. m2

I550.13 High tensile steel fabric – mesh C385 (C7), 3.41 kg/m2. m2

I550.14 High tensile steel fabric – mesh C503 (C8), 4.34 kg/m2. m2

I550.15 High tensile steel fabric – mesh C636 (C9), 5.55 kg/m2. m2

I550.16 High tensile steel fabric – mesh C785 (C10), 6.72 m2


kg/m2.

I560 Fabric of other stated material. m2

I600 CONCRETE ANCILLARIES

Joints

Rate for joints shall be deemed to include formwork.

I611 Construction joint, [150 mm wide]. m

I612 Contraction joints, [200 mm wide]. [Rate to include m


surface of joint with two coats of polyether paint].

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI67 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I613 Expansion joints, [250 mm wide]. [Rate to include 25 m


mm thick resin bonded cork filler].

I614.1 [230 mm] wide rubber waterstop. Rate to include cutting m


and jointing of waterstops and provision of special
fittings at angles and junctions.

I614.2 [230 mm] wide rubber waterstop with central bulb. Rate m
to include cutting and jointing of waterstops and
provision of special fittings at angles and junctions.

I615.1 Sealed [20 mm x 20 mm] grooves with polyether sealant. m

I615.2 Sealed [40 mm x 20 mm] grooves with polyether sealant. m

I616 Dowels – plain, [25 mm diameter x 300 mm long] steel nr


bars at [600 mm] centres.

I617 Dowels – sleeved and capped, [25 mm diameter x 300 nr


mm long] steel bars at [600 mm] centres.

Post-Tensioned Prestressing

Rate for prestressing shall be deemed to include ducts,


jacking, grouting, and other components and tasks
ancillary to prestressing.

I621 Horizontal internal tendons in in situ concrete, [seven] nr


wire standard strand to BS 5896, Class 1; [nominal
diameter 12 mm]; concrete cone anchors to BS 1477, [7
– 10] length for Beam No. [2].

I622 Inclined internal tendons in in situ concrete, [seven] nr


wire standard strand to BS 5896, Class 1; [nominal
diameter 12 mm]; concrete cone anchors to BS 1477, [7
– 10] length for Beam No. [2].

I623 Horizontal internal tendons in precast concrete, [seven] nr


wire standard strand to BS 5896, Class 1; [nominal
diameter 12 mm]; concrete cone anchors to BS 1477, [7
– 10] length for Beam No. [2].

I624 Inclined internal tendons in precast concrete, [seven] nr


wire standard strand to BS 5896, Class 1; [nominal
diameter 12 mm]; concrete cone anchors to BS 1477, [7
– 10] length for Beam No. [2].

Finishing of Top Surfaces

Rate for finishing of top surfaces shall be deemed to


include wood float or steel trowel.

I631 Power float. m2

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI68 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I632 Class U3 finish. m2

I633 Class U4 finish. m2

Finishing of Formed Surfaces

I641 Aggregate exposure using retarder. m2

I642 Bush hammering. m2

I643 Other stated surface treatment carried out after striking m2


formwork.

Inserts

I651 100 mm diameter GVC pipe. m

I652.1 10 mm diameter, 25 mm deep expanding bot projecting nr


from one surface.

I652.2 15 mm diameter, 40 mm deep rag bolt projecting from nr


one surface.

I652.3 25 mm diameter, 100 mm long mild steel holding down nr


bolt projecting from one concrete surface.

I652.4 150 mm DN ductile iron pipe with puddle flange, nr


projecting from both surfaces of concrete.

I660 Grouting with [1:3 cement sand motar] under plate of nr


size [200 mm x 200 mm].

I700 ANCILLARY WORK FOR WATER RETAINING


STRUCTURE

I710 Water proofing admixtures using [XYPEX] or m3


equivalent to be in mix proportion as recommended by
the manufacturer.

I720 Water tightness testing of [1000 m3 clear water] tanks. m3


Rate to include provision of water and all testing
equipment as per Specification clause (……..).

I730 Sterilizing and flushing of [1000 m3 clear water] tank. m3


Rate to include provision of potable water and chemicals
as per Specification clause (…..).

Linings and Coatings

Rate for linings and coatings shall be deemed to include


supply and installation/application.

I741 [20 mm thick] high alumina cement lining to [inlet m2


chamber].

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI69 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

I742 [1 mm thick] PVC lining as per Specification clause m2


(….) to sludge tanks.

I743 [2 mm thick] HDPE lining as per Specification clause m2


(….) to sludge tanks.

I744 Sodium silicate solution as per Specification clause (….) m2


to internal surfaces in contact with water of reservoir.

I745 Epoxy coatings as per Specification clause (….) to m2


sludge tanks.

Page Total carried to Summary of Class I

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI70 of BQI173
CLASS I
Concrete Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class I: Concrete Work

Page BQI1

Page BQI2

Page BQI3

Page BQI4

Page BQI5

Page BQI6

Page BQI7

Page BQI8

Page BQI9

Page BQI10

Page BQI11

Page BQI12

Total of Class I carried to Grand Summary

Class I: Concrete Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQI71 of BQI173
CLASS J
Brickwork, Blockwork, and Masonry

Item No. Code No. Description Unit Qty. Rate Amount (RM)

J100 BRICKWORK

Item for brickwork shall be deemed to include joint


reinforcement, movement joints, fixing ties, bonds to
existing work, and fixing clamps.

J111.1 [115 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for vertical straight
walls.

J111.2 [115 mm] thick [cement sand brickwork] laid in m2


stretcher bond, jointed in [1:3] cement mortar for
vertical straight walls.

J111.3 [230 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for vertical straight
walls.

J111.4 [230 mm] thick [cement sand brickwork] laid in m2


stretcher bond, jointed in [1:3] cement mortar for
vertical straight walls.

J111.5 [115 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for vertical straight
walls cavity wall construction type.

J121.1 [115 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for vertical curved
walls.

J121.2 [230 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for vertical curved
walls.

J131 [Common brickwork] laid in stretcher bond, jointed in m2


[1:3] cement mortar for battered straight walls, average
thickness of [172.5 mm], varying from 230 mm to 115
mm.

J141 [Common brickwork] laid in stretcher bond, jointed in m2


[1:3] cement mortar for battered curved walls, average
thickness of [172.5 mm], varying from [230 mm to 115
mm].

J151 [115 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar as vertical facing to
concrete.

J161 [Common brickwork] laid in stretcher bond, jointed in m2


[1:3] cement mortar for battered facing to concrete,
average thickness of [172.5 mm], varying from [230 mm
to 115 mm].

Page Total carried to Summary of Class J

Class J: Brickwork, Blockwork and Masonry


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQJ72 of BQJ173
CLASS J
Brickwork, Blockwork, and Masonry

Item No. Code No. Description Unit Qty. Rate Amount (RM)

J171 [115 mm] thick [common brickwork] laid in stretcher m2


bond, jointed in [1:3] cement mortar for casing to metal
sections.

J180.1 [Common brickwork] laid in stretcher bond, jointed in m3


[1:3] cement mortar for [600 mm x 600 mm] column.

J180.2 [Common brickwork] laid in stretcher bond, jointed in m3


[1:3] cement mortar for [600 mm x 600 mm] piers.

J200 BLOCKWORK

Item for blockwork shall be deemed to include joint


reinforcement, movement joints, fixing ties, bonds to existing
work, and fixing clamps.

J211 [115 mm] thick lightweight blockwork laid in stretcher m2


bond and jointed in [1:3] cement mortar for vertical
straight walls.

J221 [115 mm] thick lightweight blockwork laid in stretcher m2


bond and jointed in [1:3] cement mortar for vertical
curved walls.

J251 [115 mm] thick lightweight blockwork laid in stretcher m2


bond and jointed in [1:3] cement mortar as vertical
facing to concrete.

J271 [115 mm] thick lightweight blockwork laid in stretcher m2


bond and jointed in [1:3] cement mortar for casing to
metal sections.

J280.1 [Lightweight blockwork] laid in stretcher bond, jointed m3


in [1:3] cement mortar for [600 mm x 600 mm] column.

J280.2 [Lightweight blockwork] laid in stretcher bond, jointed m3


in [1:3] cement mortar for [600 mm x 600 mm] piers.

J300 MASONRY

Item for masonry shall be deemed to include fair face


finish.

J311 [300 mm] thick natural stone masonry jointed in [1:3] m2


cement mortar flush pointed for vertical straight walls.

J321 [300 mm] thick natural stone masonry jointed in [1:3] m2


cement mortar flush pointed for vertical curved walls.

Page Total carried to Summary of Class J

Class J: Brickwork, Blockwork and Masonry


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQJ73 of BQJ173
CLASS J
Brickwork, Blockwork, and Masonry

Item No. Code No. Description Unit Qty. Rate Amount (RM)

J331 Natural stone masonry jointed in [1:3] cement mortar m2


flush pointed for battered straight walls, average
thickness of [172.5 mm], varying from [230 mm to 115
mm].

J342 Natural stone masonry jointed in [1:3] cement mortar m2


flush pointed for battered curved walls, average
thickness of [225 mm], varying from [300 mm to 150
mm].

J351 [300 mm] thick natural stone masonry jointed in [1:3] m2


cement mortar flush pointed as vertical facing to
concrete.

J361 Natural stone masonry jointed in [1:3] cement mortar m2


flush pointed for battered facing to concrete, average
thickness of [172.5 mm], varying from [230 mm to 115
mm].

J371 [200 mm] thick natural stone masonry jointed in [1:3] m2


cement mortar flush pointed for casing to metal sections.

J380.1 Natural stone masonry jointed in [1:3] cement mortar m3


flush pointed for [600 mm x 600 mm] column.

J380.2 Natural stone masonry jointed in [1:3] cement mortar m3


flush pointed for [600 mm x 600 mm] piers.

J400 MISCELLANEOUS WORK

Surface Features

J411.1 Brick on edge coping. m

J411.2 Bullnosed copings. m

J411.3 Rounded copings as shown in Drawing No. (…). m

J411.4 Special sills as shown in Drawing No. (…). m

J412 [100 mm] deep rebates in brickwall. m

J413 Decorative cornices as shown in Drawing No. (….). m

J414 Band courses for brickwall as shown in Drawing No. m


(…..).

J415 Bullnose corbel as shown in Drawing No. (….). m

J416 Common brickwork pilasters as shown in Drawing No. m


(….).

Page Total carried to Summary of Class J

Class J: Brickwork, Blockwork and Masonry


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQJ74 of BQJ173
CLASS J
Brickwork, Blockwork, and Masonry

Item No. Code No. Description Unit Qty. Rate Amount (RM)

J417 Brickwork plinths as shown in Drawing No. (….). m

J418 [115 mm] thick fair facing brickwork. m2

Ancillaries

J421 Damp proof courses; width [115mm] to BS 743 Type D. m

J422 Concrete Grade C20 infills of 50 mm thick. m2

J423.1 Built-in 150 mm DN uPVC drainage pipes. nr

J423.2 Built-in 50 mm DN uPVC cable ducts. nr

Page Total carried to Summary of Class J

Class J: Brickwork, Blockwork and Masonry


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQJ75 of BQJ173
CLASS J
Brickwork, Blockwork, and Masonry

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class J: Brickwork, Blockwork, and


Masonry

Page BQJ1

Page BQJ2

Page BQJ3

Page BQJ4

Total of Class J carried to Grand Summary

Class J: Brickwork, Blockwork and Masonry


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQJ76 of BQJ173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Timber work shall be deemed to include fixing


components, fixing, fastening, boring, cutting, and
jointing.

K100 TIMBER COMPONENTS

Grade A Heavy Hardwood; Wrot Finish

K111.1 [150 mm x 150 mm cengal to columns]; length not m


exceeding 6 m.

K111.2 [100 mm x 50 mm cengal to floor joist]; length not m


exceeding 6 m.

K112 [200 mm x 75 mm cengal to floor girders]; length m


exceeding 6 m.

Grade B Medium Hardwood; Wrot Finish

K121.1 [150 mm x 75 mm keruing ] with preservative m


treatment as per Specification clause (….) to [floor
joists, girders, column……..]; length not exceeding
6 m.

K121.2 [150 mm x 75 mm keruing ], kiln dry as per m


Specification clause (….) to [floor joists, girders,
column……..]; length not exceeding 6 m.

K122.1 [150 mm x 75 mm keruing ] with preservative m


treatment as per Specification clause (….) to
[girders, ……..]; length exceeding 6 m.

K122.2 [150 mm x 75 mm keruing ], kiln dry as per m


Specification clause (….) to [girders, ……..]; length
exceeding 6 m.

Grade C Light Hardwood; Wrot Finish

K131.1 [150 mm x 75 mm meranti ] with preservative m


treatment as per Specification clause (….) to [floor
joists, girders, column……..]; length not exceeding
6 m.

K131.2 [150 mm x 75 mm meranti ], kiln dry as per m


Specification clause (….) to [floor joists, girders,
column……..]; length not exceeding 6 m.

K132.1 [150 mm x 75 mm meranti ] with preservative m


treatment as per Specification clause (….) to
[girders, ……..]; length exceeding 6 m.

K132.2 [150 mm x 75 mm meranti ], kiln dry as per m


Specification clause (….) to [girders, ……..]; length
exceeding 6 m.

Page Total carried to Summary of Class K

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK77 of BQK173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grade D Softwood; Wrot Finish

K141 [150 mm x 75 mm damar minyak ], kiln dry as per m


Specification clause (….) to [floor joists, girders,
column……..]; length not exceeding 6 m.

K142 [150 mm x 75 mm damar minyak ], kiln dry as per m


Specification clause (….) to [girders, ……..]; length
exceeding 6 m.

K200 DECKING AND BOARDING

Rate for decking and boarding shall be deemed to


include framework where expressly required; walls
and soffits shall include for any temporary staging
required.

Grade A Heavy Hardwood; Wrot Finish

K211 [150 mm wide x 32 mm thick balau ] floor deck m2


boards.

K212.1 [100 mm wide x 12 mm thick balau ] panelling to m2


wall. [Rate to include 50 mm x 50 mm balau studs
at 600 mm centres as framework].

K212.2 [150 mm wide x 40 mm thick cengal ] baffle wall to m2


flocculation tanks.

K213 [100 mm wide x 12 mm thick balau ] panelling to m2


ceiling. [Rate to include 50 mm x 50 mm balau
studs at 600 mm centres as framework].

Grade B Medium Hardwood; Wrot Finish

K221 [150 mm wide x 32 mm thick kempas ] with m2


[preservative treatment] as per Specification clause
(….) to floor deck.

K222 [100 mm wide x 12 mm thick keruing ] with m2


[peservative treatment to Specification clause (…..)]
to wall panelling. [Rate to include 50 mm x 50 mm
keruing studs at 600 mm centres as framework].

K223 [100 mm wide x 12 mm thick keruing ] with m2


[peservative treatment to Specification clause (…..)]
for panelling to ceiling. [Rate to include 50 mm x 50
mm balau studs at 600 mm centres as framework].

Page Total carried to Summary of Class K

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK78 of BQK173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grade C lLght Hardwood; Wrot Finish

K231 [150 mm wide x 25 mm thick nyatoh ] with m2


[preservative treatment] as per Specification clause
(….) to floor deck.

K232 [100 mm wide x 12 mm thick nyatoh ] with m2


[peservative treatment to Specification clause (…..)]
to wall panelling. [Rate to include 50 mm x 50 mm
keruing studs at 600 mm centres as framework].

K233 [100 mm wide x 12 mm thick nyatoh ] with m2


[peservative treatment to Specification clause (…..)]
for panelling to ceiling. [Rate to include 50 mm x 50
mm balau studs at 600 mm centres as framework].

Grade D Softwood; Wrot Finish

K241.1 [150 mm wide x 12 mm thick damar minyak ], [kiln m2


dry as per Specification clause (….) to floor deck].

K241.2 [150 mm wide x 12 mm thick sempilor ], [kiln dry as m2


per Specification clause (….) to floor deck. [Rate to
include 75 mm x 50 mm sempilor floor joists at 600
mm centres].

K242 [100 mm wide x 12 mm thick damar minyak ], kiln m2


dry as per Specification clause (…..)] to wall
panelling. [Rate to include 50 mm x 50 mm damar
minyak studs at 600 mm centres as framework].

K243 [100 mm wide x 12 mm thick nyatoh ], kiln dry as m2


per Specification clause (…..)] for panelling to
ceiling. [Rate to include 50 mm x 50 mm damar
minyak studs at 600 mm centres as framework].

K300 MISCELLANEOUS WORK

Grade A Heavy Hardwood; Wrot Finish

K311 [100 mm high x 12 mm thick chengal ] wall skirting m


to [floor].

K312 [Cengal ] hand rails with 75 mm x 75 mm post and m


75 mm x 50 mm rails as shown in Drawing No.
(………).

Page Total carried to Summary of Class K

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK79 of BQK173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

K313 [100 mm high x 50 mm wide chengal] cornice to m


ceiling with profile as shown in Drawing No.
(…….).

K314 [50 mm wide x 25 mm high chengal] dado with m


profile as shown in Drawing No. (…….) to be fixed
at [1.2 m] from the finished floor level.

Grade B Medium Hardwood; Wrot Finish

K321 [100 mm high x 12 mm thick kempas ] wall skirting m


to [floor]. Timber to be treated with preservatives as
per Specification clause (….).

K322 [Kempas ] hand rails with 75 mm x 75 mm post and m


75 mm x 50 mm rails as shown in Drawing No.
(………). Timber to be treated with preservatives as
per Specification clause (….).

K323 [100 mm high x 50 mm wide kempas] cornice to m


ceiling with profile as shown in Drawing No.
(…….). Timber to be treated with preservatives as
per Specification clause (….).

K324 [50 mm wide x 25 mm high kempas] dado with m


profile as shown in Drawing No. (…….) to be fixed
at [1.2 m] from the finished floor level. Timber to be
treated with preservatives as per Specification clause
(….).

Grade C Light Hardwood; Wrot Finish

K331 [100 mm high x 12 mm thick nyatoh ] wall skirting m


to [floor]. Timber to be treated with preservatives as
per Specification clause (….).

K332 [Nyatoh ] hand rails with 75 mm x 75 mm post and m


75 mm x 50 mm rails as shown in Drawing No.
(………). Timber to be treated with preservatives as
per Specification clause (….).

K333 [100 mm high x 50 mm wide nyatoh] cornice to m


ceiling with profile as shown in Drawing No.
(…….). Timber to be treated with preservatives as
per Specification clause (….).

K334 [50 mm wide x 25 mm high nyatoh] dado with m


profile as shown in Drawing No. (…….) to be fixed
at [1.2 m] from the finished floor level. Timber to be
treated with preservatives as per Specification clause
(….).

Page Total carried to Summary of Class K

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK80 of BQK173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Grade D Softwood; Wrot Finish

K341 [100 mm high x 12 mm thick damar minyak ] wall m


skirting to [floor]. Timber to be kiln dry as per
Specification clause (….).

K342 [Damar minyak ] hand rails with 75 mm x 75 mm m


post and 75 mm x 50 mm rails as shown in Drawing
No. (………). Timber to be kiln dry as per
Specification clause (….).

K343 [100 mm high x 50 mm wide damar minyak] cornice m


to ceiling with profile as shown in Drawing No.
(…….). Timber to be treated with preservatives as
per Specification clause (….).

K344 [50 mm wide x 25 mm high damar minyak] dado m


with profile as shown in Drawing No. (…….) to be
fixed at [1.2 m] from the finished floor level. Timber
to be treated with preservatives as per Specification
clause (….).

Page Total carried to Summary of Class K

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK81 of BQK173
CLASS K
Timber Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Su mmary of Class K: Timber Work

Page BQK1

Page BQK2

Page BQK3

Page BQK4

Page BQK5

Total of Class K carried to Grand Summary

Class K: Timber Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQK82 of BQK173
CLASS L
Metal Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

L100 SUPPLY AND ERECTION OF STRUCTURAL


MEMBERS

Item for supply and erection of structural members shall


be deemed to include delivery, protective and/or
decorative surface treatment, fabrication, handling,
hoisting, welded connections, bolted connections using
bolts of nominal diameter less than 16 mm, and
nondestructive testing as per Specification clause (...).

Supply and erection of structural members for frames;


steel to [BS:4360].

Hot-Rolled Sections

L111 [457 mm x 191 mm x 98 kg/m] mild steel universal t


column to [Grade 43A, BS 4360].

L112 [457 mm x 152 mm x 82 kg/m] mild steel universal t


beam to [Grade 43A, BS 4360].

L113 [406 mm x 146 mm x 32.74 kg/m] universal beam as t


portal frame as shown in Drawing No. (….).

15 m span mild steel truss, Grade 43A: BS 4360 for 250


mm DN pipe stream crossing as shown in Drawing No.
(….).

L114.1 203 mm x 102 mm x 23 kg/m universal beam. t

L114.2 150 x 75 x 10 mm thick x 17 kg/m angle. t

L114.3 80 x 80 x 8 mm thick x 9.63 kg/m angle. t

L114.4 60 x 60 x 6 mm thick x 5.42 kg/m angle. t

L115 12.5 mm thick x 103.1 kg/m2 Grade 43A mild steel t


chequred plates to BS 4360 as decking.

L116 [200 x 68 x 16 mm thick x 4.75 kg/m C-channel as wall t


bracings.

L117 [305 mm x 165 mm x 54 kg/m] universal beam at 800 t


mm centres as grillages.

Cold-Rolled Sections

L121 [150 x 150 x 5 mm thick] box section as column. t

L122 [200 x 100 x 5 mm thick] C-section as wall framing. t

Page Total carried to Summary of Class L

Class L: Metalwork
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQL83 of BQL173
CLASS L
Metal Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

L125 [200 x 75 x 2 mm thick] hat-section as decking to t


composite floor concstruction.

L126 [200 x 68 x 2 mm] thick C-channel as wall bracings. t

Built-up or Fabricated Sections

L131 [600 mm x 600 mm] built-up column comprising 20 mm t


thick steel plates as shown in Drawing No. (….).

L132 Built-up box girders as shown in Drawing No. (…..). t

L133 Pre-engineered steel portal frame as shown in Drawing t


No. (….).

Extruded Sections

L141 [76.1mm OD x 3.2mm thick x 5.75 kg/m] circular hollw t


section to [wall].

L142 [50 x 30 x 2.6mm thick x 3.03 kg/m] rectangular hollow t


section to [wall]

L144 [48.3 mm OD x 3.2 mm thick x 3.56 kg/m] circular t


hollow section to frame as shown in Drawing No. (….).

L146 [200 x 68 x 16 mm x 4.75 kg/m] C-channel as wall t


bracings.

Rate for black bolts shall be deemed to nuts, washers,


gusset and end plates, and other accessories.

Black Bolts

L151 Nominal diameter: 16 – 20 mm. nr

L152 Nominal diameter: 20 – 24 mm. nr

L153 Nominal diameter: 24 – 30 mm. nr

L154 Nominal diameter: 30 – 36 mm. nr

L155 Nominal diameter: 36 – 42 mm. nr

L156 Nominal diameter: 42 – 48 mm. nr

L157 Nominal diameter: 48 – 56 mm. nr

L158 Nominal diameter of [60 mm]. nr

Page Total carried to Summary of Class L

Class L: Metalwork
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQL84 of BQL173
CLASS L
Metal Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Items for high strength friction grip bolts shall be


deemed to nuts, washers, gusset and end plates, and
other accessories expressly required.

High Strength Friction Grip Bolts

L161 HSFG bolts to [BS 4604], nominal diameter [16 mm] nr


with proof load of [92.1 kN].

L162 HSFG bolts to [BS 4604], nominal diameter [22 mm] nr


with proof load of [177 kN].

L163 HSFG bolts to [BS 4604], nominal diameter [24 mm] nr


with proof load of [207 kN].

L164 HSFG bolts to [BS 4604], nominal diameter [30 mm] nr


with proof load of [286 kN].

L165 HSFG bolts to [BS 4604], nominal diameter [36 mm] nr


with proof load of [418 kN].

L166 HSFG bolts to [BS 4604], nominal diameter [42 mm] nr


with proof load of […. kN].

L167 HSFG bolts to [BS 4604], nominal diameter [48 mm] nr


with proof load of […. kN].

L168 HSFG bolts to [BS 4604], nominal diameter [60 mm] nr


with proof load of […. kN].

Anchorages and Holding Down Bolt Assemblies

L170 Anchorages and holding down bolt assemblies nr


comprising [4 Nos. 450 x 24 bolts with plates 150 x 150
x 10 mm].

L200 MISCELLANEOUS METALWORK

Item for miscellaneous metalwork shall be deemed to


include fixing to other work, supply of fixing
components, and drilling or cutting of other work.

L210 Stairways and landings; [150 mm riser with 250 mm nr


treads] as per Drawing No. (…..).

L220 [2 m] wide walkways as per Drawing No. (….). m2

L230 Galvanised mild steel ladders; [70 x 70 x 10 mm thick x m


10.3 kg/m stringer 400 mm] apart, with [20 mm]
diameter steel rungs at [300 mm] centres. Rate to
include full assemblies.

Page Total carried to Summary of Class L

Class L: Metalwork
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQL85 of BQL173
CLASS L
Metal Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

L240 Galvanised mild steel handrail of 42.4 mm diameter m


tubular section of 3.2 mm thickness and 1100 mm high
with fixing accessories as shown on the drawing.

L250 114.3 mm OD x 5.0 mm thick x 13.5 kg/m circular m


hollow section as parapets. Rate to include full
assemblies.

Decking

Rate for decking shall be deemed to include supporting


metalwork as framework.

L261 [8 mm] thick galvanised mild steel chequered plates m2


trench covers.

L262 Galvanised mild steel open mesh cover complete with m2


50 mm x 50 mm x 5.82 kg/m angle frame built-in into
the floor inclusive of RHS as supports.

L263 Welded mesh paneling. m2

L264 [6 mm] thick galvanised mild steel chequered plates m2


flooring.

L270 [Colourbond metal deck, 0.48 mm] base steel thickness m2


to wall cladding.

L280 305 mm x 165 mm x 54 kg/m mild steel Grade 43A m


universal beam as waling.

L300 MISCELLANEOUS METALWORK

Miscellaneous Framing

L311 [50 x 50 x 5 mm thick x 3.77 kg/m] angle section. m

L312 [102 mm x 51 mm x 10.42 kg/m] C-channel section. m

L313 [152 mm x 89 mm x 17.09 kg/m] I-section. m

L314 [100 x 50 x 3.2 mm thick x 7.18 kg/m] rectangular m


hollow section.

Tanks

L321 Uncovered metal steel tanks; capacity: [2140] litres; nr


dimension: [3000 L x 1670 H x 465 W] as per
Specification and as shown in the drawings.

L322 Covered stainless steel water tank; capacity: [1000] nr


litres; grade [304]; dimension [1060 dia. x 1060 H] as
per Specification and as shown in the drawings.

Page Total carried to Summary of Class L

Class L: Metalwork
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQL86 of BQL173
CLASS L
Metal Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class L: Metalwork

Page BQL1

Page BQL2

Page BQL3

Page BQL4

Total of Class L carried to Grand Summary

Class L: Metalwork
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQL87 of BQL173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M100 ROOFING WORK

Timber Roof Structure

Rate shall include connecting plates, bolts and nuts, and


other fastening system.

M111.1 [100 mm x 50 mm Group B] sawn timber rafter, as m


shown in Drawing No. (….).

M111.2 [50 mm x 25 mm Group B] sawn timber batten, as m


shown in Drawing No. (…..).

M111.3 [150 mm x 50 mm Group B] sawn timber wall plate, as m


shown in Drawing No. (….).

M112 Timber roof truss system using Grade B sawn timber m2


and components to be designed by Contractor as per
Specification clause (….). Rate shall include connecting
plates, bolts and nuts, and other fastening system.

Metal Roof Structure

Rate to include connecting plates, bolts, nuts, all


welding, and other fastening system.

M113.1 [457 mm x 191 mm x 98 kg/m] mild steel universal kg


column. [Grade 43A to BS 4360] as rafter as shown in
Drawing No. (….).

M113.2 [75 x 75 x 4 mm thick x 8.60 kg/m] mild steel square kg


hollow section, [Grade 43A to BS 4360] as top chord
member as shown in Drawing No. (….).

M113.3 [150 x 75 x 4 mm thick x 18.60 kg/m] C-channel kg


purlins. [Grade 43A to BS 4360] as shown in Drawing
No. (….).

M113.4 [200 x 68 x 2 mm] thick cold formed galvanised mild kg


steel C-channel as purlins.

M114.1 Mild steel, Grade 43A to BS 4360 roof truss system and m2
components to be designed by Contractor as per
Specification clause (….). Rate to include connecting
plates, bolts, nuts, all welding, and other fastening
system.

M114.2 Galvanised mild steel roof truss system and components m2


using cold-rolled steel to be designed by Contractor as
per Specification clause (….). Rate to include
connecting plates, bolts, nuts, all welding, and other
fastening system.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM88 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Roof Covering

Rate to include preparing surfaces, forming joints,


overlaps, mitres, angles, fillets, built-up edges, and
laying to falls or cambers, cutting, notching, bending,
and bedding.

M121.1 [6 mm thick polycarbonate flat sheet] as per m2


Specification clause (….) laid at [15 degrees to the
horizontal] as shown in Drawing No. (….).

M121.2 [6 mm thick polycarbonate flat sheet] as per m2


Specification clause (….), [with curve at radius of 10 m]
as shown in Drawing No. (….).

M122 [0.48 mm base steel thickness colourbond corrugated m2


roofing sheet] as per Specification clause (….) laid at
[15 degrees to the horizontal] as shown in Drawing No.
(….).

M123 [Interlocking concrete roofing tiles] as per Specification m2


clause (….) laid to [30 degrees to the horizontal ] as
shown in Drawing No. (….).

Underlay

Rate to include preparing surfaces, forming joints,


overlaps, mitres, angles, fillets, built-up edges, and
laying to falls or cambers, cutting, notching, bending,
and bedding.

M131 [One layer of 50 mm x 50 mm x 22 SWG galvanised m2


wire mesh fixed with tying wire as per Specification
clause (….).

M132 [One layer of double sided aluminium foil sisalation] as m2


per Specification clause (….).

Insulation

Rate to include preparing surfaces, forming joints,


overlaps, mitres, angles, fillets, built-up edges, and
laying to falls or cambers, cutting, notching, bending,
and bedding.

M141 [50 mm thick rock wool sheet size 1200 mm x 600 mm] m2
as per Specification clause (….).

M142 [50 mm thick fiberglass insulation] as per Specification m2


clause (….).

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM89 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Roofing Ancillaries

Rate to include forming holes, cutting, and making good


for services, preparing surfaces, forming joints, mitres,
angles, fillets, built-up edges, and laying to cambers or
falls.

M151.1 [180 mm x 25 mm thick timber] eave. m

M151.2 [180 mm x 25 mm thick] verge. m

M152 [180 mm x 25 mm thick timber] fascia. m

M153 [20 SWG thick galvanised mild steel flashing 300 mm m


girth].

M154 [Timber] kerbs. m

M155 [22 SWG galvanised mild steel] hood. nr

M156 Roof ventilators as per Specification clause (….). nr

M157 Soaker. nr

Flat/Profiled Sheet Components

Rate to include forming holes, cutting, and making good


for services, preparing surfaces, forming joints, mitres,
angles, fillets, built-up edges, and laying to cambers or
falls.

M161.1 [One layer of 20 mm thick asphalt to roof upstand] as m


per Specification clause (….) and as shown in Drawing
No. (….).

M161.2 [One layer of 20 mm thick asphalt to twin kerb at m


expansion joint] as per Specification clause (….) and as
shown in Drawing No. (….).

M162.1 [0.48 mm thick galvanised mild steel ridge capping 500 m


mm girth].

M162.2 [0.48 mm thick galvanised mild steel hip capping to match m


profiled metal deck roof].

M163 [2 m x 1 m x 6 mm thick] polycarbonate skylight as per nr


Specification clause (….).

M164 [2 m x 1 m x 6 mm thick corrugated transparent sheet] nr


as per Specification clause (….).

M165 [6 mm thick corrugated] ventilator sheet. nr

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM90 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M166 Roofing sheet with soaker flanges. nr

M167 Ridge ventilator. nr

Tiles Components

Rate to include forming holes, cutting, and making good


for services, preparing surfaces, forming joints, mitres,
angles, fillets, built-up edges, and laying to cambers or
falls.

M171 Valley tiles (coloured) to match interlocking tiles. m

M172 Mitred hip tiles (coloured) to match interlocking tiles. m

M173 Mitred vertical angle tiles (coloured) to match m


interlocking tiles.

M174.1 Ridge capping [500 mm girth]. m

M174.2 Hip capping [500 mm girth]. m

M175 Vertical angle tiles (coloured) to match interlocking m


tiles.

M176 Saddle (coloured) to match interlocking tiles. nr

M177 Glass tiles to match interlocking tiles. nr

Gutters and Downpipes

Rate for gutters and downpipes to include fixing and


supply of fixing components.

M181 [150 mm half round uPVC] rainwater gutters. m

M182 [150 mm half round uPVC] elbow for gutters. nr

M183 [100 diameter uPVC] rain water down pipes. m

M184 [100 diameter uPVC] elbow for rain water down pipes. nr

M200 WATER PROOFING

Rate for water proofing to include preparing surfaces,


forming joints, overlaps, mitres, angles, fillets, built-up
edges, and laying to falls or cambers.

Asphalt

M211 [One layer of 20 mm thick asphalt] laid on sloping m2


surface area.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM91 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M212 [One layer of 20 mm thick asphalt] laid on horizontal m2


surface area.

M213 [One layer of 20 mm thick asphalt] laid on vertical m2


surface area.

M214 [One layer of 20 mm thick asphalt laid on 250 mm wide m


concrete gutter].

M215 [One layer of 20 mm thick asphalt] laid on isolated nr


group of surfaces not exceeding 1 m2.

M216 [One layer of 20 mm thick asphalt lining to 100 mm nr


diameter vent pipe].

Bituminous

M221 [One layer of 6 mm thick bituminous sheet] laid on m2


sloping surface area.

M222 [One layer of 6 mm thick bituminous sheet] laid on m2


horizontal surface area.

M223 [One layer of 6 mm thick bituminous] laid on vertical m2


surface area.

M224 [One layer of 6 mm thick bituminous] laid on 300 mm m


wide concrete gutter.

M225 [One layer of 6 mm thick bituminous sheet] lay on nr


isolated group of surfaces not exceeding 1 m2.

M226 [One layer of 6 mm thick bituminous lining] to sides of nr


concrete gutter.

Sheet Metal

M231 [One layer of 0.5 mm thick zinc sheet] laid on sloping m2


timber boarding roof.

M232 [One layer of 0.5 mm thick zinc sheet] laid on m2


horizontal timber boarding roof.

M233 [One layer of 0.5 mm thick zinc sheet] laid on vertical m2


surface area.

M234 [One layer of 0.5 mm thick zinc sheet] laid on timber m


surfaces of width not exceeding 300 mm.

M235 [One layer of 0.5 mm thick zinc sheet] laid on isolated nr


group of surfaces not exceeding 1 m2.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM92 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Waterproofing Sheeting

M241 [One layer of 1 mm thick polyethylene sheet] laid on m2


sloping surface area.

M242 [One layer of 1 mm thick polyethylene sheet] lay on m2


horizontal surface area.

M243 [One layer of 1 mm thick polyethylene sheet] laid on m2


vertical surface area.

M244 [One layer of 1 mm thick polyethylene sheet] laid on m


surface of width not exceeding 300 mm.

M245 [One layer of 1 mm thick polyethylene sheet] laid on nr


isolated group of surfaces not exceeding 1 m2.

M246 [One layer of 1 mm thick polyethylene lining to concrete nr


surfaces.

Waterproof Coating

M251 [One layer of 5 mm thick waterproofing membrane] as m2


per Specification clause (….) laid on sloping surface
area.

M252 [One layer of 5 mm thick waterproofing membrane] as m2


per Specification clause (….) laid on horizontal surface
area.

M253 [One layer of 5 mm thick waterproofing membrane] as m2


per Specification clause (….) laid on vertical surface
area.

M254 [One layer of 5 mm thick waterproofing membrane] as m


per Specification clause (….) laid on surface of width
not exceeding 300 mm.

M255 [One layer of 5 mm thick waterproofing membrane] as nr


per Specification clause (….) laid on isolated group of
surfaces not exceeding 1 m2.

M256 [One layer of 5 mm thick waterproofing membrane] as nr


per Specification clause (….) to concrete gutter.

Rendering in Ordinary Cement Mortar

M261 [One layer of 25 mm thick 1:3 cement sand mortar] laid m2


on sloping surface area.

M262 [One layer of 25 mm thick 1:3 cement sand mortar] laid m2


on horizontal surface area.

M263 [One layer of 25 mm thick 1:3 cement sand mortar] laid m2


on vertical surface area.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM93 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M264 [One layer of 25 mm thick 1:3 cement sand mortar] bed m


at verge of roof] of width not exceeding 300 mm.

M265 [One layer of 25 mm thick 1:3 cement sand mortar] laid nr


on isolated group of surfaces not exceeding 1 m2.

M266 [One layer of 25 mm thick 1:3 cement sand mortar] at nr


rainwater outlet.

Rendering in Water Proof Cement Mortar

M271 [One layer of 25 mm thick 1:3 cement sand mortar with m2


waterproofing agent] as per Specification clause (….)
laid on sloping surface area.

M272 [One layer of 25 mm thick 1:3 cement sand mortar with m2


waterprofing agent] as per Specification clause (….) laid
on horizontal surface area.

M273 [One layer of 25 mm thick 1:3 cement sand mortar with m2


waterproofing agent] as per Specification clause (….)
laid on vertical surface area.

M274 [One layer of 25 mm thick 1:3 cement sand mortar with m


waterproofing agent] as per Specification clause (….)
laid on surface of width not exceeding 300 mm.

M275 [One layer of 25 mm thick 1:3 cement sand mortar with nr


waterproofing agent] as per Specification clause (….)
laid on isolated group of surfaces not exceeding 1 m2.

M276 [One layer of 25 mm thick 1:3 cement sand mortar with nr


waterproofing agent] as per Specification clause (….)
laid rainwater outlet.

Sprayed or Brushed Waterproofing

M281 [One layer of 2 mm thick waterproofing material as per m2


manufacturer's instruction] sprayed on sloping surface
area.

M282 [One layer of 2 mm thick waterproofing material as per m2


manufacturer's instruction] sprayed on horizontal surface
area.

M283 [One layer of 2 mm thick waterproofing material as per m2


manufacturer's instruction] sprayed on vertical surface
area.

M284 [One layer of 2 mm thick waterproofing material as per m


manufacturer's instruction sprayed concrete gutter
(measured separately) not exceeding 300 mm wide].

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM94 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M285 [One layer of 2 mm thick waterproofing material as per nr


manufacturer's instruction] sprayed on isolated group of
surfaces not exceeding 1 m2.

M286 [One layer of 2 mm thick waterproofing material as per nr


manufacturer's instruction sprayed at construction joint].

M300 WINDOWS AND DOORS

Rate for windows and doors to include fixing, supply of


fixing components, drilling or cutting of associated
work, and all associated glazing work.

Timber

M312 [Grade A] timber windows; [1200 mm x 1200 mm] nr


fitted with standard sill and complete with 6 mm thick
float glass louvres and 10 mm security bar as shown in
Drawing No. (……).

M313 [Grade A, 2100 mm x 900 mm] timber doors frames as nr


shown in Drawing No. (….).

M314.1 Single leaf solid [Grade A] timber door type (…….] as nr


shown in Drawing No. (….).

M314.2 Double leaf solid [Grade A] timber door type (…….] as nr


shown in Drawing No. (….).

M315 [Two-hour rated fire resistant] double leaf solid timber nr


door type (…..) as per Specification clause (….).

All ironmongery to include necessary fixing screws.

M317.1 Pair of stainless steel hinges; [75 mm x 50 mm]. nr

M317.2 Pair of stainless steel butt hinges; [100 mm x 75 mm]. nr

M317.3 ["Mobel C3600-70-SS-Ent-HOM" ] cyclindrical knobset nr


with stainless steel finish.

M317.4 ["St Guchi D264-70-SS-HOM"] half deadbolt. nr

M317.5 ["Dorma"] door closers, [140 mm x 22 mm]. nr

M318 Supply and fix anti-vermin netting on outside to nr


window.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM95 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Metal

M321 Natural anodised windows sub-frames to suit [1200 mm nr


x 1200 mm] side hung casement window as per
Specification clause (…..) and as shown the Drawing
No. (…).

M322 [1200 mm x 1200 mm] natural anodised aluminium side nr


hung casement window complete with 6 mm thick clear
float glass as shown in Drawing No. (…).

M323 Natural anodised aluminium door frames to suit [2100 nr


mm x 900 mm] door as shown the Drawing No. (…).

M324 Natural anodised aluminium door complete with 6 mm nr


thick clear glass as showin in the drawings [Size: 900
mm x 2100 mm].

M326 Natural anodised motorised aluminium roller shutter nr


door complete with rollers, guide, pelmet, and locks;
[4000 mm x 3500 mm] as shown in Drawing No. (…..).

Plastics

M334 PVC doors; 32 mm thick; [2100 mm x 900 mm]. nr

M337.1 Pair of stainless steel hinges; [75 mm x 50 mm]. nr

M337.2 ["St Guchi D264-70-SS-HOM"] half deadbolt. nr

M400 GLAZING

M410.1 6 mm clear float glass, fixed with putty. m2

M410.2 10 mm tinted glass, fixed with putty. m2

M420 [3000 x 2000 x 10 mm thick] clear float glass panel to m2


be fixed with silicone.

M430 [3000 x 2000 x 10 mm thick] laminated glass panel to be nr


fixed with silicone.

M440 Hermetically sealed units for double glazed panel. nr

M450 500 x 500 x 4 mm thick mirror with 4 nos. drilled holes, nr


fixed with dome head mirror screws.

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM96 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M500 FINISHES

Floor Finishes

Rate for floor finishes to include fixing, supply of fixing


components, drilling or cutting of associated work,
preparing surfaces, forming joints, mitres, angles, fillets,
built-up edges, and laying to chambers or falls.

M511 Homogeneous tiles; [300 x 300 x 7.6 mm thick]. Rate to m2


include cement mortar screed.

M512 [25 mm thick] cement and sand pavings to floor. m2

M513 [25 mm] thick granolithic finish to floor. m2

M514 [10 mm] thick wash aggregates finish to floor. m2

M515 [500 mm x 500 mm] square carpet tiles with knot m2


density of 30 knots per cm2 as per Specification clause
(….).

M516 [4 mm] thick vinyl sheet floor covering. Rate to include m2


approved adhesive bedding component.

M517 Floor hardener with iron aggregate or 100% ferrous m2


metallic surface applied at the rate of 4.0 kg/m2, finished
with a layer of acrylic based curing compound.

Skirting to Floor

Rate for skirting to floor shall be deemed to include


fixing, supply of fixing component, drilling or cutting of
associated work, preparing surfaces, forming joints,
mitres, angles, fillets, built-up edges, laying to cambers
or falls and cement mortar screed.

M520 Homogenous tiles skirting [100 mm high x 7.6 mm] m


thick; rounded top edge.

Wall Finishes

Rate for wall finishes to include fixing, supply of fixing


components, drilling or cutting of associated work,
preparing surfaces, forming joints, mitres, angles, fillets,
and built-up edges.

M531 [200 mm x 250 mm] ceramic wall tiles. Rate to include m2


cement mortar screed.

M532 [20 mm] thick cement and sand plastering to wall. m2

M533 [20 mm] thick granolithic finish to wall. m2

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM97 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M534 [10 mm] thick wash aggregates finish to wall. m2

M535 Spray tiles. m2

M536 Prefabricated panel [200 x 200 x 25 mm thick] to be m2


fixed at wall as decorative panel.

Ceiling Finishes

Rate for ceiling finishes to include any temporary


staging required.

M541 Skim coat plaster to soffits and sides of beam. m2

M542 [20 mm] thick cement and sand rendering to soffit of m2


roof slab.

M543.1 [600 x 1200 x 22 mm thick] fibreglass suspended m2


ceilings. Rate to include aluminium tees and stainless
steel hangers.

M543.2 [600 x 1200 x 3.2 mm thick] autoclaved cellulose fibre m2


cement board suspended ceilings. Rate to include
aluminium tees and stainless steel hangers.

M543.3 [10 mm thick] gypsum plasterboard ceilings. Rate to m2


include [50 mm x 50 mm] pressure treated sawn timber
at 600 mm centres as framework.

M543.4 [10 mm thick] gypsum plasterboard ceilings. Rate to m2


include [50 x 25 x 1 mm thick] galvanised cold formed
mild steel section at 600 mm centres as framework.

M544 Cornices. m

M545 [600 mm x 600 mm] access panel. nr

M600 FLOOR AND WALL SYSTEM

Wall Partition

Rate for wall partitions to include fixing, supply of


fixing components, drilling or cutting of associated
work, forming holes, cutting, and making good for
services.

M611 [100 mm] thick eco-solid wall system. m2

M612 [10 mm] thick full board m2

Page Total Carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM98 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

M613 [10 mm] thick half board with 6 mm thick fixed float m2
glass

M614 [2000 mm x 1500 mm x 2200 mm] cubicle sets nr

M620 Raised access floor, [600 x 600 x 33 mm thick] high m2


density processed timber panels sandwiched between
two sheets of equal thickness plastic laminates. Rate to
include all accessories such as cable outlets, skirting
boards, PVC fascias, panel lifters, etc.

M700 PLUMBING WORK

Cold Water Plumbing System

M710 Cold water plumbing system as per Specification clause sum


(….) and as shown schematically in Drawing No. (….).
Rate to include all fittings, stop-cocks, and taps.

Water Storage Tank

M720 [3000 litres] HDPE water storage tank as per nr


Specification clause (….). Rate to include supporting
frame.

Sanitary Plumbing System

M730 Sanitary plumbing system as per Specification clause sum


(….) and as shown schematically in Drawing No. (….).
Rate to include all fittings.

Sanitary Appliances and Fittings

M740 Water closets; [Claytan 404 6-litre single flush side nr


lever], bottom inlet overflow cistern with flapper valve
internal fittings including medium duty plastic seat and
cover.

Page Total carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM99 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Septic Tanks

Rate for septic tanks shall be deemed to include


foundation, excavation, upholding sides of excavation,
bedding, installation, backfilling, and all other related
works where expressly required.

M751 Septic tank for five population equivalent (PE) with a nr


minimum of 24 hours of hydraulic retention time and a
dual size aggregate down flow filter media as shown in
Drawing No. (….).

M752 Pre-fabricated polyethylene septic tank for five nr


population equivalent (PE) with incorporated filter
chamber on the oulet section. Rate to include
foundation, excavation, upholding sides of excavation,
bedding, installation, backfilling, and all other related
work where expressly required.

Page Total carried to Summary of Class M

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM100 of BQM173
CLASS M
Building Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class M: Building Work

Page BQM1

Page BQM2

Page BQM3

Page BQM4

Page BQM5

Page BQM6

Page BQM7

Page BQM8

Page BQM9

Page BQM10

Page BQM11

Page BQM12

Page BQM13

Total of Class M carried to Grand Summary

Class M: Building Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQM101 of BQM173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Painting shall be deemed to include preparation of


surfaces, application of base primer/sealer required
before painting and all necessary temporary staging.

N100 OIL PAINT

Metal Surfaces

Rate for painting of metal shall be deemed to include


painting the surfaces of connecting plates, brackets,
rivets, bolts, nuts, and similar projections.

Prepare and apply [two] coats of base primer and [two]


coats of oil paint to:

N111 Metal surfaces of [columns, beams, ….] exceeding 300 m2


mm girth.

N112 Metal surfaces of [columns, ….] not exceeding 300 mm m


girth.

Timber

Rate for painting of timber shall be deemed to include


painting the surfaces of recesses, projections, and
fittings.

Prepare and apply [one] coat of base primer and [two]


coats of oil paint to:

N121 Timber surfaces of [columns, beams, …..] exceeding m2


300 mm girth.

N122 Timber surfaces of [columns, …..] not exceeding 300 m


mm girth.

Pipework

Rate for painting of pipework shall be deemed to include


painting the surfaces of flanges, valves, and other
projecting fittings and hangers.

Prepare and apply [one] coat of base primer and [two]


coats of oil paint to:

N161 Pipework surfaces of members exceeding 300 mm girth. m2

N162 Pipework surfaces of members not exceeding 300 mm m


girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN102 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

N200 ALKYD GLOSS PAINT

Metal Surfaces

Rate for painting of metal shall be deemed to include


painting the surfaces of connecting plates, brackets,
rivets, bolts, nuts, and similar projections.

Prepare and apply [one] coat of base primer and [two]


coats of alkyd gloss paint to:

N211 On metal surfaces of [columns, beams, ….] exceeding m2


300 mm girth.

N212 On metal surfaces of [columns, ….] not exceeding 300 m


mm girth.

Timber

Rate for painting of timber shall be deemed to include


painting the surfaces of recesses, projections, and
fittings.

Prepare and apply [one coat ] of base primer and [two]


coats of alkyd gloss paint to:

N221 Timber surfaces of [colums, beams, …..] exceeding 300 m2


mm girth.

N222 Timber surfaces of [colums, …..] not exceeding 300 mm m


girth.

Pipework

Rate for painting of pipeworks shall be deemed to


include painting the surfaces of flanges, valves, and
other projecting fittings and hangers.

Prepare and apply [one] coat of base primer and [two]


coats of alkyd gloss paint to:

N261 Pipework surfaces of members exceeding 300 mm girth. m2

N262 Pipework surfaces of members not exceeding 300 mm m


girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN103 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

N300 EMULSION PAINT OR ACRYLIC PAINT

Smooth Surfaces

Prepare and apply [one] coat of sealer and [two] coats of


emulsion paint to:

N331.1 Smooth plastered surfaces of internal [walls, columns, m2


….] exceeding 300 mm girth.

N331.2 Smooth concrete surfaces of internal [walls, column,….] m2


formed using Class F2 formwork exceeding 300 mm
girth.

N331.3 Smooth concrete surfaces of internal [walls, column, m2


….] formed using Class F3 formwork, exceeding 300
mm girth.

Prepare and apply [one] coat of sealer and [two] coats of


acrylic paint to:

N331.4 Smooth plastered surfaces of external [walls, colums, m2


….] exceeding 300 mm girth.

N331.5 Smooth concrete surfaces of external [walls, column, m2


….] formed using Class F2 formwork, exceeding 300
mm girth.

N331.6 Smooth concrete surfaces of external [walls, column, m2


….] formed using Class F3 formwork, exceeding 300
mm girth.

Rough Surfaces

Prepare and apply [one] coat of sealer and [two] coats of


emulsion paint to:

N341.1 Rough rendered surfaces of internal [ceiling soffit] m2


exceeding 300 mm girth.

Prepare and apply [one] coat of sealer and [two] coats of


acrylic paint to:

N341.2 Rough rendered surfaces of external [walls, column, m2


…...] exceeding 300 mm girth.

N341.3 Rough concrete surfaces of external [walls, column, ….] m2


formed using Class F1 formwork, exceeding 300 mm
girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN104 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Masonry

Prepare and apply [one] coat of sealer and [two] coats of


acrylic paint to:

N351 Masonry surfaces of members exceeding 300 mm girth. m2

N400 CEMENT PAINT

Prepare and apply [one] coat of sealer and [two] coats of


cement paint externally to:

Rough Surfaces

N441 Concrete surfaces of members exceeding 300 mm girth. m2

Masonry

N451 Masonry surfaces of members exceeding 300 mm girth. m2

N500 EPOXY OR POLYURETHANE PAINT

Metal Surfaces

Rate for painting of metal shall be deemed to include


painting the surfaces of connecting plates, brackets,
rivets, bolts, nuts, and similar projections.

Prepare and apply [one] coat of base primer and two


coats of epoxy paint externally to:

N511.1 Metal surfaces other than pipework; surfaces of m2


members exceeding 300 mm girth.

N512.1 Metal surfaces other than pipework; surfaces of m


members not exceeding 300 mm girth.

Prepare and apply [one] coat of base primer and two


coats of polyurethane paint externally to:

N511.2 Metal surfaces other than pipework; surfaces of m2


members exceeding 300 mm girth.

N512.2 Metal surfaces other than pipework; surfaces of m


members not exceeding 300 mm girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN105 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Smooth Surfaces

Prepare and apply [one] coat of base primer and two


coats of epoxy paint externally to:

N531.1 Smooth plastered surfaces of [walls, columns, ….] m2


exceeding 300 mm girth.

N531.2 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F2 formwork exceeding 300 mm
girth.

N531.3 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F3 formwork exceeding 300 mm
girth.

Prepare and apply [one] coat of base primer and two


coats of polyurethane paint externally to:

N531.4 Smooth plastered surfaces of [walls, columns, ….] m2


exceeding 300 mm girth.

N531.5 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F2 formwork exceeding 300 mm
girth.

N531.6 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F3 formwork exceeding 300 mm
girth.

Rough Surfaces

Prepare and apply [one] coat of base primer and two


coats of epoxy paint externally to:

N541.1 Rough rendered surfaces of [walls, columns, …...] m2


exceeding 300 mm girth.

N541.2 Rough concrete surfaces of [walls, columns, ….] formed m2


using Class F1 formwork, exceeding 300 mm girth.

Prepare and apply [one] coat of base primer and two


coats of polyurethane paint externally to:

N541.3 Rough rendered surfaces of [walls, columns, …...] m2


exceeding 300 mm girth.

N541.4 Rough concrete surfaces of [walls, columns, ….] formed m2


using Class F1 formwork, exceeding 300 mm girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN106 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Pipework

Rate for painting of pipework shall be deemed to include


painting the surfaces of flanges, valves, and other
projecting fittings and hangers.

Prepare and apply [one] coat of base primer and two


coats of epoxy paint externally to:

N561.1 Pipework surfaces of members exceeding 300 mm girth. m2

N562.1 Pipework surfaces of members not exceeding 300 mm m


girth.

Prepare and apply [one] coat of base primer and two


coats of polyurethane paint externally to:

N561.2 Pipework surfaces of members exceeding 300 mm girth. m2

N562.2 Pipework surfaces of members not exceeding 300 mm m


girth.

N600 BITUMINOUS OR COAL TAR PAINT

Prepare and apply [two] coats of bituminous or coal tar


paint to:

Metal Surfaces

Rate for painting of metal shall be deemed to include


painting the surfaces of connecting plates, brackets,
rivets, bolts, nuts, and similar projections.

N611 Metal surfaces other than pipework; surfaces of m2


members exceeding 300 mm girth.

N612 Metal surfaces other than pipework; surfaces of m


members not exceeding 300 mm girth.

Smooth Surfaces

N631.1 Smooth plastered surfaces of [walls, columns, ….] m2


exceeding 300 mm girth.

N631.2 Smooth concrete surfaces of class F2 exceeding 300 mm m2


girth.

N631.3 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F2 formwork, exceeding 300 mm
girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN107 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Rough Surfaces

N641.1 Rough rendered surfaces of [walls, columns, …...] m2


exceeding 300 mm girth.

N641.2 Rough concrete surfaces of [walls, columns, ….] formed m2


using Class F1 formwork exceeding 300 mm girth.

Pipework

Rate for painting of pipeworks shall be deemed to


include painting the surfaces of flanges, valves, other
projecting fittings and hangers.

N661 Pipework surfaces of members exceeding 300 mm girth. m2

N662 Pipework surfaces of members not exceeding 300 mm m


girth.

N700 CHLORINATED RUBBER PAINT

Prepare and apply [one] coat of base primer and [two]


coats of chlorinated rubber paint to:

Metal Surface

Rate for painting of metal shall be deemed to include


painting the surfaces of connecting plates, brackets,
rivets, bolts, nuts, and similar projections.

N711 Metal surfaces other than pipework; surfaces of m2


members exceeding 300 mm girth.

N712 Metal surfaces other than pipework; surfaces of m


members not exceeding 300 mm girth.

Smooth Surfaces

N731.1 Smooth plastered surfaces of [walls, columns, ….] m2


exceeding 300 mm girth.

N731.2 Smooth concrete surfaces of [walls, column, ….] formed m2


using Class F2 formwork exceeding 300 mm girth.

N731.3 Smooth concrete surfaces of [walls, columns, ….] m2


formed using Class F3 formwork exceeding 300 mm
girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN108 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Rough Surfaces

N741.1 Rough rendered surfaces of [walls, columns, …...] m2


exceeding 300 mm girth.

N741.2 Rough concrete surfaces of [walls, columns, ….] formed m2


using Class F1 formwork exceeding 300 mm girth.

Pipework

Rate for painting of pipework shall be deemed to include


painting the surfaces of flanges, valves, and other
projecting fittings and hangers.

N761 Pipework surfaces of members exceeding 300 mm girth. m2

N762 Pipework surfaces of members not exceeding 300 mm m


girth.

Page Total carried to Summary of Class N

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN109 of BQN173
CLASS N
Painting Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class N: Painting Work

Page BQN1

Page BQN2

Page BQN3

Page BQN4

Page BQN5

Page BQN6

Page BQN7

Page BQN8

Total of Class N carried to Grand Summary

Class N: Painting Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQN110 of BQN173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O100 TRENCH EXCAVATION

Trench excavation shall be deemed to include


preparation of surfaces, excavation for bedding, multiple
handling, disposal of surplus excavated material
(including unsuitable material), upholding sides of
excavation, allowance for working space, backfilling,
removal of dead services, and reinstatement of original
surface unless covered by separate items.

100 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 100 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 100 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 100 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 100 mm DN pipe, depth 2.5 – 3.0 m. m

150 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 150 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 150 mm DN pipe, depth 1.5 – 2 m. m

O113 In earth for 150 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 150 mm DN pipe, depth 2.5 – 3.0 m. m

200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 200 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 200 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 200 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 200 mm DN pipe, depth 2.5 – 3.0 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO111 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

300 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 300 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 300 mm DN pipe, depth 1.5 – 2 m. m

O113 In earth for 300 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 300 mm DN pipe, depth 2.5 – 3.0 m. m

400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 400 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 400 mm DN pipe, depth 1.5 – 2 m. m

O113 In earth for 400 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 400 mm DN pipe, depth 2.5 – 3.0 m. m

500 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 500 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 500 mm DN pipe, depth 1.5 – 2 m. m

O113 In earth for 500 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 500 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 500 mm DN pipe, depth 3.0 – 4.0 m. m

600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 600 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 600 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 600 mm DN pipe, depth 2.0 – 2.5 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO112 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O114 In earth for 600 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 600 mm DN pipe, depth 3.0 – 4.0 m. m

800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in


Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 800 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 800 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 800 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 800 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 800 mm DN pipe, depth 3.0 – 4.0 m. m

1000 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 1000 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 1000 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 1000 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 1000 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 1000 mm DN pipe, depth 3.0 – 4.0 m. m

1200 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 1200 mm DN pipe, depth not exceeding 1.5 m


m

O112 In earth for 1200 mm DN pipe, depth 1.5 – 2 m m

O113 In earth for 1200 mm DN pipe, depth 2.0 – 2.5 m m

O114 In earth for 1200 mm DN pipe, depth 2.5 – 3.0 m m

O115 In earth for 1200 mm DN pipe, depth 3.0 – 4.0 m m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO113 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

1400 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 1400 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 1400 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 1400 mm DN pipe, depth 2.0. – 2.5 m m

O114 In earth for 1400 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 1400 mm DN pipe, depth 3.0 – 4.0 m. m

1600 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 1600 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 1600 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 1600 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 1600 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 1600 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 1600 mm DN pipe, depth 4.0 – 5.0 m. m

1800 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 1800 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 1800 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 1800 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 1800 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 1800 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 1800 mm DN pipe, depth 4.0 – 5.0 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO114 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

2000 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O111 In earth for 2000 mm DN pipe, depth not exceeding 1.5 m


m.

O112 In earth for 2000 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 2000 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 2000 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 2000 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 2000 mm DN pipe, depth 4.0 – 5.0 m. m

2200 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O112 In earth for 2200 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 2200 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 2200 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 2200 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 2200 mm DN pipe, depth 4.0 – 5.0 m. m

2400 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O112 In earth for 2400 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 2400 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 2400 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 2400 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 2400 mm DN pipe, depth 4.0 – 5.0 m. m

O117 In earth for 2400 mm DN pipe, depth 5.0 – 6.0 m. m

2600 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O112 In earth for 2600 mm DN pipe, depth 1.5 – 2.0 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO115 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O113 In earth for 2600 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 2600 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 2600 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 2600 mm DN pipe, depth 4.0 – 5.0 m. m

O117 In earth for 2600 mm DN pipe, depth 5.0 – 6.0 m. m

2800 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos. (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O112 In earth for 2800 mm DN pipe, depth 1.5 – 2.0 m. m

O113 In earth for 2800 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 2800 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 2800 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 2800 mm DN pipe, depth 4.0 – 5.0 m. m

O117 In earth for 2800 mm DN pipe, depth 5.0 – 6.0 m. m

O118 In earth for 2800 mm DN pipe, depth exceeding 6.0 m. m

3000 mm DN pipe [Jalan Paip to Jalan Besi] as shown


in Drawing Nos (…) to (…). Width of trench shall be as
shown in Drawing No. (…) and Specification clause
(…).

O113 In earth for 3000 mm DN pipe, depth 2.0 – 2.5 m. m

O114 In earth for 3000 mm DN pipe, depth 2.5 – 3.0 m. m

O115 In earth for 3000 mm DN pipe, depth 3.0 – 4.0 m. m

O116 In earth for 3000 mm DN pipe, depth 4.0 – 5.0 m. m

O117 In earth for 3000 mm DN pipe, depth 5.0 – 6.0 m. m

O118 In earth for 3000 mm DN pipe, depth exceeding 6.0 m. m

Extras to Trench Excavation

O121 Rock. m3

O122 Natural hard material. m3

O123 Artificial hard material. m3

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO116 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O124 Roads and pavement, rate to include road cutting and m2


reinstatement.

Excavation for Manholes and Chambers

O131.1 In earth for [manholes]. m3

O131.2 In earth for [valve chambers]. m3

O132.1 Roads and pavement for [manholes]. m2

O132.2 Roads and pavement for [valve chambers], rate to m2


include road cutting and reinstatement.

O133.1 Artificial hard material for [manholes]. m3

O133.2 Artificial hard material for [valve chambers]. m3

O134.1 Natural hard material for [manholes]. m3

O134.2 Natural hard material for [valve chambers]. m3

O135.1 In rock for [manholes]. m3

O135.2 In rock for [valve chambers]. m3

O200 BACKFILLING AND BEDDING MATERIALS

Bedding

O211 [150 mm thick] sand bedding as per Specification clause m


(…..) and as shown in Drawing No. (….).

O212 [150 mm thick] granular material as bedding as per m


Specification clause (…..) and as shown in Drawing No.
(….).

O213 [150 mm thick] Grade C20 mass concrete bedding. Rate m


to include formwork.

O214 [150 mm thick] Grade C25 reinforced concrete bedding m


with one layer of high tensile steel fabric – mesh A193
(A7), 3.02 kg/m2. Rate to include formwork.

Surround

O221 [250 mm] sand surround as per Specification clause m


(…..) and as shown in Drawing No. (….).

O222 [200 mm] granular material surround as per m


Specification clause (…..) and as shown in Drawing No.
(….).

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO117 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O223 [150 mm] Crade C20 mass concrete surround. Rate to m


include formwork.

O224 [150 mm] Grade C25 reinforced concrete surround with m


one layer of high tensile steel fabric – mesh A193 (A7),
3.02 kg/m2 all round. Rate to include formwork.

Backfilling

O231 Backfilling with sand to Specification clause (….). m3

O232 Backfilling with granular material to Specification m3


clause (….).

O300 PIPES

Supply, laying or install. Rate to include all pipe cutting,


wrapping, lining and lagging as required.

Sewerage Pipework

Vitrified clay pipes, spigot socket ended including


supply and making joints complete as per Specification
clause (….) for the following:

O311.1 [100 mm DN] in standard length of 1.25 m. Rate to m


include all fittings and valves.

O311.2 [150 mm DN] in standard length of 1.50 m. m

O311.3 [200 mm DN] in standard length of 1.50 m. m

O311.4 [225 mm DN] in standard length of 2.0 m. m

O311.5 [300 mm DN] in standard length of 2.50 m. m

O311.6 [400 mm DN] in standard length of 2.50 m. m

O311.7 [600 mm DN] in standard length of 2.50 m. m

O311.8 [1400 mm DN] in standard length of 2.0 m. m

[Centrifugally spun] reinforced concrete pipes, spigot


socket ended to [MS 881] lined internally with [12 mm
thick high alumina cement mortar] as per Specification
clause (….). Rate to include supply and making joint
complete for the following:

O312.1 450 mm DN in standard length of 3.0 m. m

O312.2 600 mm DN in standard length of 3.0 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO118 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O312.3 750 mm DN in standard length of 3.0 m. m

O312.4 900 mm DN in standard length of 3.0 m. m

O312.5 1200 mm DN in standard length of 3.0 m. m

O312.6 1500 mm DN in standard length of 3.0 m. m

O312.7 1800 mm DN in standard length of 3.0 m. m

High density polyethylene corrugated wall pipes to


[DIN 16961]. Rate to include supply and making joints
complete.

O313.1 100 mm DN in standard length of 6 m. Rate to include m


all fittings and valves.

O313.2 150 mm DN in standard length of 6 m. m

O313.3 200 mm DN in standard length of 6 m. m

O313.4 300 mm DN in standard length of 6 m. m

O313.5 450 mm DN in standard length of 6 m. m

O313.6 600 mm DN in standard length of 6 m. m

[Spigot socket ended] ductile iron pipes to [BS EN 545,


with metallic zinc and bitumen external coating and
cement mortar lined internally] as per Specification
clause (…). Rate to include supply and making joints
complete for the following:

O314.1 100 mm DN in standard length of 6 m. Rate to include m


all fittings and valves.

O314.2 150 mm DN in standard length of 6 m. m

O314.3 200 mm DN in standard length of 6 m. m

O314.4 300 mm DN in standard length of 6 m. m

O314.5 400 mm DN in standard length of 6 m. m

O314.6 500 mm DN in standard length of 6 m. m

O314.7 600 mm DN in standard length of 6 m. m

O314.8 700 mm DN in standard length of 6 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO119 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

[Mild] steel pipes, Grade 43A to [BS 534, with bitumen


wrap externally and concrete lining internally] as per
Specification clause (….) for the following:

O315.1 100 mm DN [spigot socket ended] in standard length of m


6 m. Rate to include all fittings, valves, and joints.

O315.2 150 mm DN [spigot socket ended] in standard length of m


6 m.

O315.3 200 mm DN [spigot socket ended] in standard length of m


6 m.

O315.4 300 mm DN [spigot socket ended] in standard length of m


6 m.

O315.5 400 mm DN [spigot socket ended] in standard length of m


6 m.

O315.6 450 mm DN [spigot socket ended] in standard length of m


6 m.

O315.7 500 mm DN [spigot socket ended] in standard length of m


10 m.

O315.8 600 mm DN [spigot socket ended] in standard length of m


10 m.

O315.9 800 mm DN [spigot socket ended] in standard length of m


10 m.

O315.10 1000 mm DN [spigot socket ended] in standard length of m


10 m.

O315.11 2200 mm DN [spigot socket ended] in standard length of m


10 m.

O315.12 2300 mm DN [spigot socket ended] in standard length of m


7.5 m.

O315.13 2600 mm DN [spigot socket ended] in standard length of m


7.5 m.

O315.14 3000 mm DN [spigot socket ended] in standard length of m


7.5 m.

Spigot socket ended glass reinforced plastic pipes, as


per Specification clause (…). Rate to include supply and
making joints complete for the following:

O316.1 [300 mm DN, PN 16] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO120 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O316.2 [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

O316.3 [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

O316.4 [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O316.5 [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O316.6 [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O316.7 [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

High density polyethylene (HDPE) solid wall plain


ended pipe to MS 1058 as per Specification clause (….)
for the following:

O317.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m

O317.2 [110 mm OD, PE 100, PN 20] in standard length of 12 m


m.

O317.3 [200 mm OD, PE 80, PN 16] in standard length of 12 m. m

O317.4 [450 mm OD, PE 80, PN 16] in standard length of 12 m. m

O317.5 [710 mm OD, PE 80, PN 12.5] in standard length of 12 m


m.

Acrylonitrile butadiene styrene (ABS) pipe plain


ended to MS 1419 as per Specification clause (…) for
the following:

O318.1 [140 mm OD, PN6] in standard length of 5.8 m. Rate to m


include all fittings, valves, and joints.

O318.2 [225 mm OD, PN 10] in standard length of 5.8 m. m

O318.3 [250 mm OD, PN 12] in standard length of 5.8 m. m

O318.4 [355 mm OD, PN 15] in standard length of 5.8 m. m

O318.5 [400 mm OD, PN 15] in standard length of 5.8 m. m

O318.6 [450 mm OD, PN 15] in standard length of 5.8 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO121 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O318.7 [560 mm OD, PN 15] in standard length of 5.8 m. m

O318.8 [630 mm OD, PN 15] in standard length of 5.8 m. m

O318.9 [710 mm OD, PN 10] in standard length of 5.8 m. m

Water Supply Pipework

[Mild] steel pipes, Grade 43A to [BS 534, with bitumen


wrap externally and concrete lining internally] as per
Specification clause (….) for the following:

O321.1 100 mm DN [spigot socket ended] in standard length of m


6 m. Rate to include all fittings, valves, and joints.

O321.2 150 mm DN [spigot socket ended] in standard length of m


6 m.

O321.3 200 mm DN [spigot socket ended] in standard length of m


6 m.

O321.4 300 mm DN [spigot socket ended] in standard length of m


6 m.

O321.5 400 mm DN [spigot socket ended] in standard length of m


6 m.

O321.6 450 mm DN [spigot socket ended] in standard length of m


6 m.

O321.7 500 mm DN [spigot socket ended] in standard length of m


10 m.

O321.8 600 mm DN [spigot socket ended] in standard length of m


10 m.

O321.9 800 mm DN [spigot socket ended] in standard length of m


10 m.

O321.10 1000 mm DN [spigot socket ended] in standard length of m


10 m.

O321.11 2200 mm DN [spigot socket ended] in standard length of m


10 m.

O321.12 2300 mm DN [spigot socket ended] in standard length of m


7.5 m.

O321.13 2600 mm DN [spigot socket ended] in standard length of m


7.5 m.

O321.14 3000 mm DN [spigot socket ended] in standard length of m


7.5 m.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO122 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

[Spigot socket ended] ductile iron pipes to [BS EN 545,


with metallic zinc and bitumen external coating and
cement mortar lined internally] as per Specification
clause (…). Rate to include supply and making joints
complete for the following:

O322.1 100 mm DN in standard length of 6 m. Rate to include m


all fittings and valves.

O322.2 150 mm DN in standard length of 6 m. m

O322.3 200 mm DN in standard length of 6 m. m

O322.4 300 mm DN in standard length of 6 m. m

O322.5 400 mm DN in standard length of 6 m. m

O322.6 500 mm DN in standard length of 6 m. m

O322.7 600 mm DN in standard length of 6 m. m

O322.8 700 mm DN in standard length of 6 m. m

High density polyethylene (HDPE) solid wall plain


ended pipe to MS 1058 as per Specification clause (….)
for the following:

O323.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m

O323.2 [110 mm OD, PE 100, PN 20] in standard length of 12 m


m.

O323.3 [200 mm OD, PE 80, PN 16] in standard length of 12 m. m

O323.4 [450 mm OD, PE 80, PN 16] in standard length of 12 m. m

O323.5 [710 mm OD, PE 80, PN 12.5] in standard length of 12 m


m.

Unplasticised polyvinyl chloride (uPVC) pipes to MS


628, with bell mouth joints as per Specification clause
(….). Rate to include supply and making joints complete
for the following:

O324.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to m


include fittings and valves.

O324.2 [155 mm DN, PN 15] in standard length of 6 m. m

O324.3 [200 mm DN, PN 15] in standard length of 6 m. m

O324.4 [250 mm DN, PN 15] in standard length of 6 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO123 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O324.5 [300 mm DN, PN 15] in standard length of 6 m. m

Spigot socket ended glass reinforced plastic pipes, as


per Specification clause (…). Rate to include supply and
making joints complete for the following:

O325.1 [300 mm DN, PN 16] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

O325.2 [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

O325.3 [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in m


standard length of [12 m].

O325.4 [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O325.5 [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O325.6 [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O325.7 [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in m


standard length of [12 m].

O326 [300 mm DN] plain ended stainless steel pipes as per m


Specification clause (….).

Acrylonitrile butadiene styrene (ABS) pipe plain


ended to MS 1419 as per Specification clause (…) for
the following:

O327.1 [88.9 mm OD, PN6] in standard length of 5.8 m. Rate to m


include all fittings, valves, and joints.

O327.2 [225 mm OD, PN 10] in standard length of 5.8 m. m

O327.3 [250 mm OD, PN 12] in standard length of 5.8 m. m

O327.4 [355 mm OD, PN 15] in standard length of 5.8 m. m

O327.5 [400 mm OD, PN 15] in standard length of 5.8 m. m

O327.6 [450 mm OD, PN 15] in standard length of 5.8 m. m

O327.7 [560 mm OD, PN 15] in standard length of 5.8 m. m

O327.8 [630 mm OD, PN 15] in standard length of 5.8 m. m

O327.9 [710 mm OD, PN 10] in standard length of 5.8 m. m

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO124 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Multilayer polyvinyl chloride(MPVC) pipes to JIS


K6742 with bell moouth joints as per Specification
clause (….). Rate to include supply and making joints
complete for the following:

O328.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to m


include fittings and valves.

O328.2 [155 mm DN, PN 15] in standard length of 6 m. m

O328.3 [200 mm DN, PN 15] in standard length of 6 m. m

O328.4 [250 mm DN, PN 15] in standard length of 6 m. m

O328.5 [300 mm DN, PN 15] in standard length of 6 m. m

Other Pipework

[Spigot socket ended] ductile iron pipes to [BS EN 545,


with metallic zinc and bitumen external coating and
cement mortar lined internally] as per Specification
clause (…). Rate to include supply and making joints
complete for the following:

O331.1 100 mm DN in standard length of 6 m. Rate to include m


all fittings and valves.

O331.2 150 mm DN in standard length of 6 m. m

O331.3 200 mm DN in standard length of 6 m. m

O331.4 300 mm DN in standard length of 6 m. m

O331.5 400 mm DN in standard length of 6 m. m

O331.6 500 mm DN in standard length of 6 m. m

O331.7 600 mm DN in standard length of 6 m. m

O331.8 700 mm DN in standard length of 6 m. m

[Mild] steel pipes, Grade 43A to [BS 534, with bitumen


wrap externally and concrete lining internally] as per
Specification clause (….) for the following:

O332.1 100 mm DN [spigot socket ended] in standard length of m


6 m. Rate to include all fittings, valves, and joints.

O332.2 150 mm DN [spigot socket ended] in standard length of m


6 m.

O332.3 200 mm DN [spigot socket ended] in standard length of m


6 m.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO125 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O332.4 300 mm DN [spigot socket ended] in standard length of m


6 m.

O332.5 400 mm DN [spigot socket ended] in standard length of m


6 m.

O332.6 450 mm DN [spigot socket ended] in standard length of m


6 m.

O332.7 500 mm DN [spigot socket ended] in standard length of m


10 m.

O332.8 600 mm DN [spigot socket ended] in standard length of m


10 m.

Unplasticised polyvinyl chloride (uPVC) pipes to MS


628, with bell moouth joints as per Specification clause
(….). Rate to include supply and making joints complete
for the following:

O333.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to m


include fittings and valves.

O333.2 [155 mm DN, PN 15] in standard length of 6 m. m

O333.3 [200 mm DN, PN 15] in standard length of 6 m. m

O333.4 [250 mm DN, PN 15] in standard length of 6 m. m

O333.5 [300 mm DN, PN 15] in standard length of 6 m. m

High density polyethylene (HDPE) solid wall plain


ended pipe to MS 1058 as per Specification clause (….)
for the following:

O334.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m

O334.2 [110 mm OD, PE 100, PN 20] in standard length of 12 m


m.

O334.3 [200 mm OD, PE 80, PN 16] in standard length of 12 m. m

O334.4 [450 mm OD, PE 80, PN 16] in standard length of 12 m. m

O334.5 [710 mm OD, PE 80, PN 12.5] in standard length of 12 m


m.

Vitrified clay pipes, spigot socket ended including


supply and making joints complete as per Specification
clause (….) for the following:

O335.1 [100 mm DN] in standard length of 1.25 m. Rate to m


include all fittings and valves.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO126 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O335.2 [150 mm DN] in standard length of 1.50 m. m

O335.3 [200 mm DN] in standard length of 1.50 m. m

O335.4 [225 mm DN] in standard length of 2.0 m. m

O335.5 [300 mm DN] in standard length of 2.50 m. m

O335.6 [400 mm DN] in standard length of 2.50 m. m

O335.7 [600 mm DN] in standard length of 2.50 m. m

O335.8 [1400 mm DN] in standard length of 2.0 m. m

Reinforced concrete pipes to [MS 881] butt jointed


with collars as per Specification clause (….). Rate to
include supply and making joint complete for the
following:

O336.1 [450 mm DN, Class X] in standard length of 3.0 m. m

O336.2 [600 mm DN, Class Y] in standard length of 3.0 m. m

O336.3 [750 mm DN, Class Z] in standard length of 3.0 m. m

O336.4 [900 mm DN, Class X] in standard length of 3.0 m. m

O336.5 [1200 mm DN, Class Y] in standard length of 3.0 m. m

O336.6 [1500 mm DN, Class Z] in standard length of 3.0 m. m

O336.7 [1800 mm DN, Class Z] in standard length of 3.0 m. m

O337 [300 mm DN] plain ended stainless steel pipes as per m


Specification clause (….).

Exposed Pipework

O341 [300 mm DN] plain ended mild steel pipes to BS 534, m


concrete lined internally and painted externally with
primer and finishing coat as per Specification clause
(…) for stream-overcrossing at Sg. (…) as shown in
Drawing No. (…).

O342 [300 mm DN] plain ended stainless steel pipes as per m


Specification clause (…) for elevated pipe as shown in
Drawing No. (…).

O343 [300 mm DN double flanged] ductile iron pipes to [BS m


EN 545, with metallic zinc and bitumen external coating
and cement mortar lined internally] as per Specification
clause (…) for drain overcrossing as shown in Drawing
No. (...).

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO127 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O400 FITTINGS, VALVES, AND JOINTS

Straight Specials

Item for straight specials shall be deemed to include


cutting where applicable.

[Mild] steel pipes and fittings, shall be to Grade 43A to


[BS 534, with bitumen wrap externally and concrete
lining internally] as per Specification clause (….):

Ductile iron pipes and fittings shall be to [BS EN 545,


with metallic zinc and bitumen external coating and
cement mortar lined internally] as per Specification
clause (…).

O411 [300 mm DN] mild steel plain ended pipes, [2000 mm] nr
long.

O412 [300 mm DN] plain and flanged ended mild steel pipes, nr
[2000 mm] long. Flanges shall be [PN 16 to BS EN
1092-1].

O413.1 [300 mm DN] flanged ended mild steel pipes, [2000 nr


mm] long. Flanges shall be [PN 16 to BS EN 1092-1].

O413.2 [300 mm DN] flanged ended ductile iron pipes, [2000 nr


mm] long. Flanges shall be [PN 16 to BS EN 1092-1].

O414 [300 mm DN] plain ended mild steel pipe, [2000 mm] nr
long with puddle flange at [1000 mm] from one end.
Details of puddle flange shall be as shown in Drawing
No. (…).

O415 [300 mm DN] plain and flanged ended mild steel pipe, nr
[2000 mm] long with puddle flange at [1000 mm] from
flange end. Flange shall be [PN 16 to BS EN 1092-1]
and details of puddle flange shall be as shown in
Drawing No. (…).

O416.1 [300 mm DN] flanged ended mild steel pipe, [2000 mm] nr
long with puddle flange at [1000 mm] from one end.
Flanges shall be [PN 16 to BS EN 1092-1] and details of
puddle flange shall be as shown in Drawing No. (…).

O416.2 [300 mm DN] flanged ended ductile iron pipe, [2000 nr


mm] long with puddle flange at [1000 mm] from one
end. Flanges shall be [PN 16 to BS EN 1092-1] and
details of puddle flange shall be as shown in Drawing
No. (…).

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO128 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Fittings

O421.1 [300 mm DN, 90-degree plain ended mild steel nr


gusseted] horizontal bend.

O421.2 [300 mm DN, 45-degree plain ended mild steel nr


gusseted] horizontal bend.

O421.3 [300 mm DN, 45-degree plain ended mild steel nr


gusseted] vertical bend.

O421.4 [300 mm DN, 45-degree plain ended mild steel nr


gusseted] vertical bend painted externally with primer
and finishing coat as per Specification clause (…).

O421.5 [300 mm DN, 90-degree double socket ended ductile nr


iron] horizontal bend.

O421.6 [300 mm DN, 90-degree double flanged ductile iron nr


short radius] horizontal bend.

O421.7 [300 mm DN, 45-degree double flanged ductile iron nr


short radius] vertical bend.

O421.8 [300 mm DN, 90-degree double flanged ductile iron nr


long radius] horizontal bend.

O421.9 [300 mm DN, 90-degree plain ended HDPE gusseted] nr


horizontal bend.

O422.1 [300 mm DN] vitrified clay bellmouth Y-junction nr

O422.2 [300 mm DN] vitrified clay bellmouth tee. nr

O423.1 [300 mm DN] plain ended barrel with [100 mm DN] nr


flanged branch concentric mild steel tee for air-valve as
shown in Drawing No. (…).

O423.2 [300 mm DN] plain ended barrel with [100 mm DN] nr


flanged branch level invert mild steel tee for washout as
shown in Drawing No. (…).

O424 [600 mm DN] plain ended barrel with [400 mm DN] nr


flanged branch concentric mild steel wye as shown in
Drawing No. (…).

O425.1 [600 mm DN] to [400 mm DN] plain ended mild steel nr


concentric taper as shown in Drawing No. (…).

O425.2 [600 mm DN] to [400 mm DN] plain ended mild steel nr


level invert taper as shown in Drawing No. (…).

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO129 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O426 [600 mm DN] ductile iron flanged bell mouth. Flanges nr


shall be [PN 6 to BS EN 1092-1].

O427.1 [600 mm DN] ductile iron blank flanges. Flanges shall nr


be [PN 10 to BS EN 1092-1].

O427.2 [600 mm DN] mild steel blank flanges. Flanges shall be nr


[PN 10 to BS EN 1092-1].

O428 [300 mm DN] double flanged ductile iron duckfoot nr


bend.

Valves

O431.1 [100 mm DN] single orifice air valves. Rate to include nr


isolating butterfly valve.

O431.2 [150 mm DN] double orifice air valves. Rate to include nr


isolating butterfly valve.

O432.1 [600 mm DN] double flanged butterfly valves, PN 10 nr


manually operated as per Specification clause (…). Rate
to include reduction gears.

O432.2 [600 mm DN] double flanged butterfly valves, PN 16 nr


complete with electric actuators as per Specification
clause (…). Rate to include reduction gears.

O433 [300 mm DN] double flanged gate valves, PN 10 nr


manually operated as per Specification clause (…). Rate
to include reduction gears.

O434 [600 mm DN] full bore altitude valves as per nr


Specification clause (…).

O435 [600 mm DN] pressure reducing valves as per nr


Specification clause (…).

O436 [600 mm DN] pressure sustaining valves as per nr


Specification clause (…).

O437 [300 mm DN] double flanged non return valves, non- nr


slam type, PN 16 as per Specification clause (…).

O438 [300 mm DN] double flanged plug, PN 16 as per nr


Specification clause (…).

Valves

O441 [600 mm square] stainless steel penstocks as per nr


Specification clause (…).

O442 [300 mm DN] cast iron flap gates as per Specification nr


clause (….).

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO130 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O443 [200 mm DN] flat seat valves. nr

O444 Pillar hydrants with double outlets as per Specification nr


clause (….).

O445 [150 mm DN] stainless steel strainer. nr

Joints

Items for joints shall include supply of all jointing


materials, bolts, nuts, washers, gaskets, making good of
joints both internally and externally.

O451.1 [600 mm DN] mild steel welded collar joints. nr

O451.2 [800 mm DN] mild steel welded collar joints. Rate to nr


include welding to internal of pipe and air testing of
joints.

O451.3 HDPE welded collar by electrofusion for [180 mm OD, nr


PE 80, PN 16] pipe.

O452.1 [600 mm DN] mild steel welded slip joints. nr

O452.2 [800 mm DN] mild steel welded slip joints. Rate to nr


include welding to internal of pipe and air testing of
joints.

O453 Butt fusion welded joints for [180 mm OD, PE 80, PN nr


16] pipe.

O454.1 [300 mm DN] mechanical coupling joints. nr

O454.2 [300 mm DN] mechanical stepped coupling joints. nr

O455 [300 mm DN] flange adaptor joints as shown in nr


Drawing No. (….).

O456 [600 mm DN] expansion joints as shown in Drawing nr


No. (….).

O457 Push-on collar joints for 300 mm DN HDPE profiled nr


wall pipes.

O458 Push-on slip joints for [900 mm DN] centrifugally spun nr


reinforced concrete pipes.

O460.1 [200 mm DN] flow meter/bulk meter of the "Kent Helix" nr


type.

O460.2 [200 mm DN] electromagnetic flow meter. nr

O460.3 [200 mm DN] ultrasonic flow meter. nr

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO131 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O500 BELOW GROUND CROSSINGS

Rate for below ground crossings shall include


reinstatement work.

River, Stream, Culvert, or Canal

O511 River, stream, culvert, or canal width, 1 – 3 m for [300 nr


mm DN] pipe.

O521 River, stream, culvert, or canal width, 3 – 10 m for [300 nr


mm DN] pipe.

O531 River, stream, culvert, or canal width exceeding 10 m nr


for [300 mm DN] pipe.

Fence

O541 Crosssing under fence for [300 mm DN] pipe. nr

Sewer or Drain

O551.1 Crosssing over existing [400 mm DN] sewer pipe for nr


[300 mm DN] pipe. Rate to include concrete surround to
existing existing sewer pipe.

O551.2 Crosssing under 600 mm block drain for [300 mm DN] nr


pipe. Rate to include concrete surround to pipe.

Wall

O561 Crossing under brickwall fence for [300 mm DN] pipe. nr


Rate to include concrete surround to pipe.

Other Stated Underground Services

O571 Crossing under existing 600 mm DN water mains for nr


[300 mm DN] pipe. [Rate to include sand surround to
both existing and new pipe].

O600 SPECIAL PIPE LAYING METHODS

Item for special pipe laying methods is deemed to


include mobilisation and demobilisation.

Pipe Jacking – Road crossing for [600 mm DN] water


pipe at Jalan [Besi} by pipe jacking as shown in
Drawing No. (….).

O611 Design, excavate, construct, and maintain jacking pits nr


including sheet piling, bracing, waling, concrete thrust
wall, anchor foundation, guide rails, and backfilling, etc.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO132 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O612 Design, excavate, construct, and maintain receiving pits nr


including sheet piling, bracing, waling, concrete thrust
wall, anchor foundation, guide rails, and backfilling, etc.

O613 Supply, haul, handle, jack in, and install of 1200 mm DN m


Reinforced Concrete jacking pipe class 'Z'. Rate to
include mild steel joint and excavation within pipe
sleeve and other materials for complete installation.

O615 Install [600 mm DN mild] steel pipes, Grade 43A to [BS m


534, with bitumen wrap externally and concrete lining
internally] within pipe sleeve.

O616 Pressure grouting for annulus space in between [600 mm m3


DN steel pipe] and pipe sleeve as per Specification
clause (….).

Microtunneling – Road crossing for [600 mm DN]


water pipe at Jalan [Besi} by microtunneling as shown
in Drawing No. (….).

O621 Design, excavate, construct, and maintain jacking pits nr


including sheet piling, bracing, waling, concrete thrust
wall, anchor foundation, guide rails, and backfilling, etc.

O622 Design, excavate, construct, and maintain receiving pits nr


including sheet piling, bracing, waling, concrete thrust
wall, anchor foundation, guide rails, and backfilling, etc.

O624 Supply, haul, handle, jack in, and install of 1200 mm DN m


concrete cladded steel composite pipe. Rate to include
mild steel joint and excavation within pipe sleeve and
other materials for complete installation.

O625 Install [600 mm DN mild] steel pipes, Grade 43A to [BS m


534, with bitumen wrap externally and concrete lining
internally] within pipe sleeve.

O630 [450 mm OD, PE 80, PN 16] butt fusion welded HDPE m


pipe using the horizontal directional drilling method.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO133 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Submarine Pipelaying

O641 Bathymetric survey as per Specification clause (….) of m


approximately [25 km] by [500 m] at 25 meters line
interval with cross ties at [250 m].

O642 Sub-sea geophysical survey as per Specification clause m


(….) of approximately [25 km] by [500 m] at 50 meters
line interval with cross ties at [500 m]. Rate to include
report by a geophysicist.

O643 Mobilisation of all necessary plant and equipment, sum


marine vessels, [winches], [lar-barge], etc to suit the
method statement adopted for laying the sub-sea
pipelines. Rate to include demobilisation upon
completion of work.

O644 Provision of winch equipment to suit method statement sum


adopted for laying the sub-sea pipelines.

O645 Trenching across Sg. (….) for [300 mm DN] pipe as m


shown in Drawing No. (….) with cover of at least 1.5 m
cover at the banks and 0.3 m at the deepest section of
the river.

O646 [60 mm thick] concrete cladding to [300 mm DN] steel m


pipe.

O651 Lay [300 mm DN] API grade steel pipes by float and m
sink method.

O652 Lay [300 mm DN] API grade steel pipes by bottom pull m
method.

O653 Lay [500 mm DN] mild steel pipes by lay barge method. m

O654 Carry out tie-in of riser pipe to land pipe as detailed in sum
approved methd statement.

O655 Swabbing and gauging of completed pipeline until m


pipeline is clean and confirm integrity of pipeline to
Specification clause (….).

O656 Inspection of sub-sea pipeline by divers. sum

Pipe Bursting

O661 [450 mm OD, PE 80, PN 16] butt fusion welded HDPE m


pipe using the pipe bursting method.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO134 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Slip Lining

O671 Slip lining to existing 450 mm DN asbestos cement pipe m


using [450 mm OD, PE 80, PN 16] butt fusion welded
HDPE pipe

O700 REHABILITATION OF EXISTING PIPEWORK


SYSTEM

Preparation of Existing Pipework for Rehabilitation

For 900 mm DN sewer from Manhole A to Manhole B.

O711 Cleaning, jetting, and removal of carbonaceous m


formation intrusions. Rate to include making good
existing sewer pipe.

O712 Local internal repairs. m2

O713.1 Pipe joint sealing, with cement mortar. m

O713.2 Pipe joint sealing, with epoxy mortar under pressure. m

O714 External grouting using 4 nos. of holes. nr

O715 External grouting by injection of cement grout as per m3


Specification clause (…..).

Rehabilitation of Existing Pipework

O721 Cured in place lining with resin impregnated felt tube to m


finished internal daimeter of [600 mm].

O722 In situ jointed pipe lining using glass reinforced plastic m


as per Specification clause (….) to finished internal
diameter of 900 mm.

O723.1 Circular segmental lining using glass reinforced plastic m


as per Specification clause (….), with miniumum
finished internal diameter of 900 mm.

O723.2 Circular segmental lining using 15 mm thick glass m


reinforced concrete as per Specification clause (….),
with miniumum finished internal diameter of 900 mm.

O724 Stated proprietory lining, diameter stated. m

O725 [50 mm thick] gunite coating to [900 mm DN] sewer m2


pipe.

O726 Cement grout as per Specification clause (…..) as m3


annulus grouting to [900 mm DN} pipe.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO135 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Rehabilitation of Existing Manholes

O731 Abandonment of existing manholes as per Drawing No. nr


(….) for depth of [2.5 m] including removing cover slab,
breaking back shaft sealing off the ends of existing
pipework and backfilling with sand.

O732 Modification of existing manholes for manhole as shown nr


in Drawing No. (…..) including work to benching and
inverts, breaking out, re-haunching, and dealing with
flows.

O800 MISCELLANEOUS WORK

Sewer Manholes

O811 Brick manholes Type [A] with heavy duty cover and nr
frame for [2.5 m depth] as shown in Drawing No. (….).
Rate to include blinding, reinforced concrete base and
top slabs.

O812 Reinforced concrete manholes with heavy duty cover nr


and frame Type [1] as shown in Drawing No. (…..).

O813 Reinforced concrete manholes with backdrops, heavy nr


duty cover, and frame Type [1] as shown in Drawing
No. (…..). Rate to include the pipework and associated
fittings comprising the backdrops.

O814 Precast concrete manholes Type [2] with heavy duty nr


cover and frame as shown in Drawing No. (…..).

O815 Precast concrete manholes with backdrops Type [3] with nr


heavy duty cover and frame as shown in Drawing No.
(….). Rate to include the pipework and associated
fittings comprising the backdrops.

Testing and Inspection

Rate for testing and inspection shall be deemed to


include provision, and removal of all equipment, and
ancillaries required for testing.

O821 Testing of [300 mm DN vitrified clay pipe] gravity m


sewer. Rate to include testing by infiltration and
provision of all water required for testing.

O822 Testing of [300 mm DN vitrified clay pipe] vacuum m


sewer. Rate to include all equipment required.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO136 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O823 Pressure and leakage testing for [600 mm DN mild steel m


pipe] from Jalan [Pipe] to Jalan [Besi]. Rate to include
provision of all water required for testing.

O824 Flushing and sterilisingf or [600 mm DN mild steel pipe] m


from Jalan [Pipe] to Jalan [Besi]. Rate to include
chemicals and provision of water.

O825 Close circuit television inspection survey for [300 mm m


DN] sewer pipe from Manhole [A] to Manhole [B] as
shown in Drawing No. (…..).

O826 Radiographic test for 3% of all welds for mild steel nr


pipeline.

O827 Holiday detector test, rate to include provision of sum


equipment, testing, and maintenance.

O828 Ultrasonic test, rate to include provision of equipment, sum


testing, and maintenance.

Temporary Diversion

O831 Temporary diversion of existing utilities. Rate to include sum


coordination with relevant authorities and provision of
and removal of all equipment and ancillaries required,
including pumping over.

O832 Temporary diversion of sewage flows for [300 mm DN] sum


pipe from Manhole [A] to Manhole [B} as shown in
Drawing No. (.......). Rate to include coordination with
relevant authorities and provision of and removal of all
equipment and ancillaries required including pumping
over.

Connections to Existing Sewer System

Item for connections to existing sewer system shall be


deemed to include coordination with authorities,
payment of fees, isolations for shutdown of flows, and
dewatering.

O841 At existing [brick] manhole, size [1.5 m x 1.5 m x 2.0 m nr


deep of [600 mm DN] vitrified clay sewer pipe.

O842 At Y-junction of existing [600 mm DN] vitrified clay nr


sewer pipe.

O843 With saddle connection to existing [600 mm DN] nr


vitrified clay sewer pipe.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO137 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

O844 New manhole at existing [600 mm DN] vitrified clay nr


sewer pipe. Rate to include breaking away of existing
sewer pipe as required and all pipework and metalwork
within the manhole.

Connection to Existing Water Mains

O851 Hot tapping connection work to existing [900 mm DN nr


steel pipeline] as shown in Drawing No. (…..). Rate to
injclude tapping tees, isolating valve, and testing.

O852 Shut down connection work to existing [900 mm DN nr


steel pipeline] as shown in Drawing No. (…..). Rate to
include coordination with authorities, payment of fees,
isolations for shutdown of flows, and dewatering.

Pipework Ancillaries

O861 Marker posts for air valve, washout, and isolating valves nr
as shown in Drawing No. (….). Rate to include supply,
installation, and painting.

O862 Ring girder for [1000 mm DN] mild steel pipe stream nr
crossing at Sg. (…) as shown in Drawing No. (….). Rate
to include supply, installation, and painting.

O863 Pipe straps for [600 mm DN] exposed pipelines. Rate to nr


include supply, installation, and painting.

O864 Spike guard for [600 mm DN] mild steel pipe stream nr
crossing at Sg. (…) as shown in Drawing No. (….). Rate
to include supply, installation, and painting.

O870 Reinstatement of landscaping from Ch (….) to Ch (….) sum


for [600 mm DN] pipelaying work along Jalan [Besi].

O880 Water sampling station as per Specification clause nr


(……). Rate to include connections to mains.

Page Total carried to Summary of Class O

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO138 of BQO173
CLASS O
Pipework

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class O: Pipework

Page BQO1

Page BQO2

Page BQO3

Page BQO4

Page BQO5

Page BQO6

Page BQO7

Page BQO8

Page BQO9

Page BQO10

Page BQO11

Page BQO12

Page BQO13

Page BQO14

Page BQO15

Page BQO16

Page BQO17

Page BQO18

Page BQO19

Page BQO20

Page BQO21

Page BQO22

Page BQO23

Page BQO24

Page BQO25

Page BQO26

Page BQO27

Page BQO28

Total of Class O carried to Grand Summary

Class O: Pipework
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQO139 of BQO173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

P100 DRAIN EXCAVATION

Drain excavation shall be deemed to include preparation


of surfaces, double handling, disposal of surplus
excavated material, upholding sides of excavation,
allowance for joints, backfilling, and removal of dead
services and reinstatement of Original Surface unless
covered by separate items.

[600 mm] precast concrete block drain for Road [A] as


shown in Drawing No. (…….).

P111.1 In earth for [600 mm precast concrete block drain], m


depth not exceeding 1.5 m.

P111.2 In earth for [600 mm precast pipe culvert], m


depth not exceeding 1.5 m.

P112.1 In earth for [600 mm precast concrete block drain], m


depth 1.5 – 2.0 m.

P112.2 In earth for [900 mm precast pipe culvert], m


depth 1.5 – 2.0 m.

P113.1 In earth for [600 mm precast concrete block drain], m


depth 2.0 – 2.5 m.

P113.2 In earth for [1200 mm precast pipe culvert], m


depth 2.0 – 2.5 m.

P114.1 In earth for [600 mm precast concrete block drain], m


depth 2.5 – 3.0 m.

P114.2 In earth for [1200 mm precast pipe culvert], m


depth 2.5 – 3.0 m.

P115.1 In earth for [600 mm precast concrete block drain], m


depth exceeding 3.0 m.

P115.2 In earth for [1800 mm precast pipe culvert], m


depth exceeding 3.0 m.

Extras to Drain Excavation

P121 Roads and pavement, rate to include road cutting and m2


reinstatement.

P122 Artificial hard material. m3

P123 Natural hard material. m3

P124 Rock. m3

Page Total carried to S ummary of Class P

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP140 of BQP173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Excavation for Inlet and Outlet Structures and


Sumps

P131.1 In earth for inlet and outlet structures to [1800 mm x m3


1800 mm] precast box culvert.

P131.2 In earth for [1000 mm x 1000 mm] brick sump. m3

P132 Roads and pavement, rate to include road cutting and m2


reinstatement.

P133 Artificial hard material. m3

P134 Natural hard material. m3

P135 Rock. m3

P200 SURFACE DRAINS

Item for surface drains shall be deemed to include


cement jointing, sand and concrete beddings, shuttering,
struts, and weepholes.

P210 Interceptor drains; reinforced concrete grade 20; 1200 m


mm wide (average) x 600 mm deep x 75 mm thick
trapezoidal shape.

P220 Bench and berm drains; reinforced concrete grade 20; m


900 mm wide x 500 mm deep x 75 mm thick V-shape.

P230 Roadside drain; 600 mm wide block drain with average m


900 mm high brick wall and plastering including 600
mm x 100 mm x 100 mm precast concrete struts at 6 m
c/c.

P240 Median drain; precast concrete U-shaped drain with dry m


weather flow; 600 mm wide x 1200 mm deep including
precast concrete struts at 6 m c/c.

P250 Toe drain; precast concrete U-shaped drain with dry m


weather flow; 1200 mm wide x 1200 mm deep including
precast concrete struts at 6 m c/c.

P260 Cascade drains; precast concrete block drain; 600 mm m


wide x 400 mm deep at berms.

P270 Monsoon drain; precast concrete U-shaped drain with m


dry weather flow; 2400 mm wide x 2400 mm deep
including precast concrete struts at 6 m c/c.

P280 Grass swale; with shape as shown in Drawing No. (…..). m

Page Total carried to Summary of Class P

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP141 of BQP173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

P300 SUBSURFACE DRAINS

Item for subsurface drains shall be deemed to include


geotextiles fabric, lining, and filter material.

P310 Subsoil drains; 1000 mm deep x 400 mm wide; 100 mm m


diameter HDPE perforated pipe including aggregate (20
mm – 40 mm) wrapped with geotextiles filter.

P320 Outlet drains; 100 mm diameter UPVC pipe including m


fittings. Rate to include bends, filter fabric and concrete
surround.

P330 300 mm thick sand as drainage blanket as per m2


Specification clause (….).

P340 [150 mm] diameter scupper drains. m

P400 DRAINAGE TO STRUCTURES ABOVE GROUND

Rate for downpipes to include fixing and supply of


fixing components.

P410 [150 diameter uPVC] rain water down pipes. m

P420 [150 diameter uPVC] elbow for rain water down pipes. nr

P500 DRAIN COVERS

Item for drain covers shall be deemed to include lifting


hook/hole and all associated fittings.

P510 Precast concrete; 600 mm wide x 75 mm thick for [100 m


kN load] median drain.

P520 Galvanised mild steel grating cover for [100 kN load], m


600 mm wide as shown in Drawing No. (….) for road
side drain.
P530 Fibre reinforced plastic for [100 kN load] as per m
Specification clause (….); 225 mm wide for roadside
drain.

Page Total carried to Summary of Class P

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP142 of BQP173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)
P600 CULVERTS

Item for culverts shall be deemed to include all joints,


water stop, concrete base, and concrete surround unless
otherwise stated.

P611 [1200 mm] diameter single precast concrete pipe culvert, m


Class [X] in standard length of 1 m.

P612 [1200 mm] diameter twin precast concrete pipe culvert, m


Class [X] in standard length of 1 m.

P613 [1200 mm] diameter triple precast concrete pipe culvert, m


Class [X] in standard length of 1 m.

Precast Box Culvert

P621.1 [1200 mm x 1200 mm] single precast box culvert in m


standard length of 1 m.

P621.2 [1200 mm x 1200 mm] single precast box culvert with m


dry weather flow in standard length of 1 m.

P622.1 [1200 mm x 1200 mm] twin precast box culvert in m


standard length of 1 m.

P622.2 [1200 mm x 1200 mm] twin precast box culvert with dry m
weather flow in standard length of 1 m.

P623.1 [1200 mm x 1200 mm] triple precast box culvert in m


standard length of 1 m.

P623.2 [1200 mm x 1200 mm] triple precast box culvert with m


dry weather flow in standard length of 1 m.

Corrugated Metal Pipe

P631 [1200 mm] diameter single corrugated metal pipe culvert m


in standard length of […] m.

P632 [1200 mm] diameter twin corrugated metal pipe culvert m


in standard length of […] m.

P633 [1200 mm] diameter triple corrugated metal pipe culvert m


in standard length of […] m.

Page Total carried to Summary of Class P

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP143 of BQP173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)
P700 SUMPS

Item for sumps shall be deemed to include sand and


concrete bedding, cement plastering, and metalwork.

P710 Bricks sumps; 900 mm x 900 mm x 1.20 m deep nr


including mild steel grating cover for [100 kN load].

P720 In situ concrete; 900 mm x 900 mm x 1.20 m deep nr


including mild steel grating cover for [100 kN load].

P730 Precast concrete; 900 mm x 900 mm x 1.20 m deep nr


including mild steel grating cover for [100 kN load].

Page Total carried to Summary of Class P

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP144 of BQP173
CLASS P
Drainage Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)
Summary of Class P: Drainage Work

Page BQP1

Page BQP2

Page BQP3

Page BQP4

Page BQP5

Total of Class P carried to Grand Summary

Class P: Drainage Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQP145 of BQP173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q100 SUBGRADE PREPARATION

Q110 Earth material to receive road pavement. Rate to include m2


scarifying, levelling, and compaction of the top 300 mm
of the subgrade.

Q120 Hard material to receive road pavement. Rate to include m2


scarifying, levelling, and compaction of the top 300 mm
of the subgrade.

Q130 Rock material to receive road pavement. Rate to include m2


tri mming of protruding rock above Final Surface, filling
of all cavities with lean concrete and filling with
approved crushed rock or gravel to the Final Surface.

Q141 Stabilise subgrade for [300 mm] top layer of subgrade m2


using [100 kg] of lime per cubic metre of soil

Q142 Stabilise subgrade for [300 mm] top layer of subgrade m2


using [800 kg] of cement per cubic metre of soil

Q200 SUB-BASE

Sub-base shall be deemed to include chamfer.

Q210 Geotextile of the [non woven] type as per Specification m2


clause (….).

Q220.1 Granular material with a [CBR value of more than 30, m2


complying with Type C] of Specification clause (…..) in
[100 mm] thick.

Q220.2 Granular material with a [CBR value of more than 30, m2


complying with Type C] of Specification clause (…..) in
[100 mm] thick to road shoulders.

Q230 Laterite as per Specification clause (…..) in [100 mm] m2


thick.

Q240 [Grade C15] lean concrete in 150 mm thick. m2

Q251 Stabilised sub-base in proportion of [one part] lime to m2


[four parts] approved earth as per Specification clause
(…..) in [100 mm] thick.

Q252 Soil cement in proportion of [one part] cement to [four m2


parts] approved earth as per Specification clause (….) in
[100 mm] thick.

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ146 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q300 ROADBASE

Roadbase shall be deemed to include chamfer.

Q310 Removal of flexible surfaces. Rate to include scarifying m2


the existing roadbase before receiving the new roadbase
material.

Q320 Gravel (natural) as per Specification clause (…..) in m2


[300 mm] thick.

Q330.1 Crushed aggregates with a [CBR value of more than 80, m2


complying with Type II] of Specification clause (…..) in
[300 mm] thick.

Q330.2 Crushed aggregates with a [CBR value of more than 80, m2


complying with Type II] of Specification clause (…..) in
[300 mm] thick to road shoulders.

Q341 Stabilised sub-base in proportion of [one part] lime to m2


[four parts] approved earth as per Specification clause
(…..) in [300 mm] thick.

Q342 Cement-bound granular material in proportion of [one m2


part] cement to [three parts] granular material as per
Specification clause (….) in [300 mm] thick.

Q343 Bitumen-bound granular material in proportion of [one m2


part] bitumen to [three parts] granular material as per
Specification clause (….) in [300 mm] thick.

Macadam

Q351 Wet mix macadam as per Specification clause (….) in m2


[200 mm] thick.

Q352 Dry bound macadam as per Specification clause (….) in m2


[200 mm] thick.

Q353 Dense bituminous macadam as per Specification clause m2


(….) in [200 mm] thick.

Q400 ROAD SHOULDER

Earth shoulders shall be deemed to include verge.

Q410 Earth shoulder as per Specification clause (….) in [200 m2


mm] thick.

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ147 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q420 Gravel shoulder as per Specification clause (….) in [200 m2


mm] thick.

Q500 SURFACING

Q510.1 Removal of flexible surface. Rate to include scarifying m2


the existing exposed surface.

Q510.2 Removal of flexible surfaces. Rate to include milling of m2


existing roadbase before receiving the new roadbase
material.

Q520.1 [Bituminuous single layer] surface dressing, [20 mm m2


thick using 10 mm chippings].

Q520.2 [Bituminuous double layer] surface dressing, [30 mm m2


thick using 14 mm chippings].

Q530 Tack coat to be applied at a rate of [0.5 litre per square m2


metre] as per Specificatio clause (….).

Q540 Prime coat to be applied at a rate of [0.35 litres per m2


square metre] as per Specificatio clause (….).

Q550 [12 mm] nominal thickness polymer modified asphalt in m2


[2] layers as per Specification clause (….).

Asphaltic Concrete

Q561 Binder course, [60 mm] thick as per Specification clause m2


(….).

Q562 Wearing course [40 mm] thick as per Specification m2


clause (….).

Dense Bituminuous Macadam

Q571 Binder course, [60 mm] thick as per Specification clause m2


(….).

Q572 Wearing course [40 mm] thick as per Specification m2


clause (….).

Q580 Regulating bituminous macadam levelling course BML t


10 to the required formation level.

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ148 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q600 CONCRETE PAVEMENT

Q611 Membranes below concrete pavements, [500 grade m2


impermeable plastic sheeting].

Q612 Bond breaker as per Specification clause (….) below m2


concrete pavement.

Q613 Bitumen below concrete pavement. m2

Reinforcement

Rate for reinforcement shall be deemed to include labour


for cutting, bending, and placing.

Q621.1 Mild steel bar reinforcement to nominal diameter [10 t


mm].

Q621.2 Mild steel bar reinforcement to nominal diameter [16 t


mm].

Q622.1 High tensile steel bar reinforcement to nominal diameter t


of [12 mm].

Q622.2 High tensile steel bar reinforcement to nominal diameter t


of [16 mm].

Q622.3 High tensile steel bar reinforcement to nominal diameter t


of [20 mm].

Q623.1 High tensile steel fabric reinforcement to MS 145, A6. m2

Q623.2 High tensile steel fabric reinforcement to MS 145, A7. m2

Q623.3 High tensile steel fabric reinforcement to MS 145, A8. m2

Q624 Fabric of other stated material. m2

Q630 Carriageway slab in [Grade C30, 200 mm] thick. Rate to m2


include steel formwork.

Q640 Concrete slab to apron [Grade C30, 150 mm] thick. Rate m2
to include steel formwork.

Joints in Concrete Pavement

Joints in concrete pavements shall be deemed to include


base preparation, joints, and cutting.

Q651 Longitudinal joints, [200 mm] deep. m

Q652 Expansion joints, [200 mm] deep. m

Q653 Construction joints, [200 mm] deep. m

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ149 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q654 Warping joints, [200 mm] deep. m

Q655 Butt joints, [200 mm] deep. m

Q656 Special joints with [12 mm nominal diameter high m


tensile steel bars] for transverse joints.

Q657 Transverse joints, [200 mm] deep. m

Pavers

Rate for pavers shall be deemed to include base


preparation, joints, and cutting.

Q661 [Precast] interlocking concrete block of [200 mm x 100 m2


mm x 60 mm thick].

Q662 [Precast] concrete flags of [900 mm x 600 mm x 50 mm m2


thick].

Q663 In situ concrete pavers, [concrete imprint, 150 mm m2


thick].

Q700 KERBS, CHANNEL, AND EDGINGS

Rate for kerbs, channels, and edgings shall be deemed to


include beds, backings, reinforcement, joints, and
cutting.

Q710.1 Precast concrete kerbs, Type I as shown in Drawing No. m


(….).

Q710.2 Precast concrete kerbs, Type II as shown in Drawing No. m


(….).

Q710.3 Precast concrete kerbs, Type III as shown in Drawing m


No. (….).

Q710.4 Precast concrete kerbs, Type IV as shown in Drawing m


No. (….).

Q720 In situ concrete kerbs, Type II as shown in Drawing No. m


(….).

Q730 Concrete edgings of [150 mm x 100 mm high]. m

Q740 Concrete channels, Type A as shown in Drawing No. m


(….).

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ150 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q800 ROAD FURNITURE

Signage

Traffic signs shall generally be in accordance with JKR


Arahan Teknik (Jalan) 2E/87 . Post mounted signages
shall be deemed to include foundations, support posts,
excavation, preparation of surfaces, disposal of
excavated material, upholding sides of excavation,
backfilling, concrete, reinforcement, and joints.

Q811.1 Non-illuminated retro-reflective mounted on nr


[aluminium] sheeting for [BERHENTI SIGN, RP.1].

Q811.2 Non-illuminated retro-reflective mounted on nr


[aluminium] sheeting for [BERI LALUAN SIGN,
RP.13].

Q811.3 Non-illuminated retro-reflective mounted on nr


[aluminium] sheeting for [ROUNDABOUT AHEAD
SIGN, WD.31].

Q811.4 Non-illuminated retro-reflective in [aluminium] sheeting nr


for [SIDE ROAD, WD.27b to be mounted on gantry].

Q812 Illuminated in [plastic] sheeting for [SIDE ROAD, nr


WD.27b to be mounted on gantry].

Q813 Electronic sign of [2.5 m] x [1.5 m] as per Specification m2


clause (…).

Pavement Markings

Pavement markings shall generally be hot-applied


superimposed reflectorised thermoplastic and in
accordance with JKR Arahan Teknik (Jalan) 2D/85.

Q821.1 Letters and shapes, [single straight directional arrow]. nr

Q821.2 Letters and shapes, [single turning directional arrow]. nr

Q821.3 Letters and shapes, [double headed directional arrow]. nr

Q822.1 [150 mm] wide continuous line [centre line] m

Q822.2 [150 mm] wide continuous line [edge line] m

Q823.1 [100 mm] wide intermittent [centre] line with [1000 m


mm] line and [1700 mm] gap

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ151 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q823.2 [100 mm] wide intermittent [lane] line with [1000 mm] m
line and [1700 mm] gap.

Q823.3 [100 mm] wide intermittent [continuity] line with [1000 m


mm] line and [1700 mm] gap.

Q824.1 Chevron marking for [cross hatching]. m2

Q824.2 Chevron marking for [diverging traffic]. m2

Q824.3 Chevron marking for [merging traffic]. m2

Delineators

Q831 Non-illuminated retro-reflective in [aluminium] sheeting nr


chevron delineators.

Q832 Delineator posts as shown in Drawing No. (……). nr

Q833 [Retroreflective] roadstud as per Specification clause nr


(…..).

Traffic Barrier

Q841.1 [Preacst concrete] New Jersey barrier as shown in m


Drawing No. (….).

Q841.2 [Cast in situ concrete] New Jersey barrier as shown in m


Drawing No. (….).

Q842 Wire rope as per Specification clause (…..). Rate to m


include bolts, nuts, posts, and other ancillary work.

Q843.1 [Single mounted corrugated steel beam] guardrail [with m


post at 1.95 m spacing inclusive of delineators]. Rate to
include bolts, nuts, posts, and other ancillary work.

Q843.2 [Single mounted corrugated steel beam] guardrail [with m


post at 3.8 m spacing inclusive of delineators]. Rate to
include bolts, nuts, posts, and other ancillary work.

Q843.3 [Double mounted corrugated steel beam] guardrail [with m


post at 1.95 m spacing inclusive of delineators]. Rate to
include bolts, nuts, posts, and other ancillary work.

Q843.4 [Double mounted corrugated steel beam] guardrail [with m


post at 3.8 m spacing inclusive of delineators]. Rate to
include bolts, nuts, posts, and other ancillary work.

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ152 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Q844 Guardrail end [with 90 degrees ramped terminal nr


treatment]. Rate to include bolts, nuts, posts, and other
ancillary work.

Q845 Pedestrian barrier of [1.5 m height] as shown in m


Drawing No. (….)].

Miscellaneous

Q851 Crash cushion as per Specification clause (…). nr

Q852 [Concrete] crash barrier as shown in Drawing No. (….). nr

Q853.1 Kilometre post, [Type A]. nr

Q853.2 Kilometre post, [Type B]. nr

Q854 Hectometre marker in [3 mm] thick [galvanised steel nr


plate] at 100-metre intervals.

Q855 Anti-glare screen of [1.5 m height using corrugated m


sections].

Q856 [Polycarbonate] noise barrier [of 1.5 m height] as per m


Specification clause (….). Rate to include supply,
fabrication, installation, bolts, nuts, posts, and other
ancillary work and maintenance.

Q857 Right of way (ROW) marker as shown in Drawing No. nr


(….).

Q860 [Carbon steel overhead] gantry of [ 20 m wide and 6 m nr


high].

Page Total carried to Summary of Class Q

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ153 of BQQ173
CLASS Q
Roads and Pavings

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class Q: Roads and Pavings

Page BQQ1

Page BQQ2

Page BQQ3

Page BQQ4

Page BQQ5

Page BQQ6

Page BQQ7

Page BQQ8

Total of Class Q carried to Grand Summary

Class Q: Roads and Pavings


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQQ154 of BQQ173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

R100 SPECIAL PRELIMINARIES

Plant and Equipment

R110 Provision of all necessary plant and equipment as per sum


Specification clause (…) including transportation to the
Site, handling, assembling, and removal off the Site after
completion of operation. Tunnelling shall be carried out
by [tunnel boring machine] for the main tunnel and [drill
and blast] for the [adit, shaft, and other underground
space].

Temporary Facilities

R121 Power supply system as per Specification clause (…). sum

R122 Ventilation system as per Specification clause (…). sum

R123 Lighting system as per Specification clause (…). sum

R124 Compressed air system as per Specification clause (…). sum

R125 Telecommunication system as per Specification clause sum


(…).

R126 Dewatering system as per Specification clause (…). sum

R129 Water supply system as per Specification clause (…). sum

Tunnel Portal

R130 Tunnel portal as per Specification clause (…) and as sum


shown in Drawing No. (…). Rate to include steel ribs,
shotcrete, sandbags, and all other necessary material and
work including its subsequent removal.

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR155 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

R200 EXCAVATION

Tunnel, Shaft, and Other Underground Space

Rate for excavation shall be deemed to include:

a) all alignment and inclination;


b) scaling, washing down, multiple handling, and
disposal off the Site or to designated area within the
Site;
c) overbreak and backfill with shotcrete or other
approved material; and
d) water and power consumption for plant, equipment
and temporary facilities.

R211.1 Excavation of [3.5 m] diameter tunnel in rock class [A to m3


D] as shown in Drawing No.(…).

R211.2 Excavation of [3.5 m] diameter tunnel in rock class [E] m3


as shown in Drawing No.(…).

R212 Excavation of [3.5 m] diameter tunnel in [residual soil] m3


as shown in the drawings. [The excavated material shall
be disposed at the designated location within the Site as
shown in Drawing No.(…)].

R221.1 Excavation of [5 m] diameter shaft in rock Class [A to m3


D] as shown in Drawing No.(…).

R221.2 Excavation of [5 m] diameter shaft in rock Class [E] as m3


shown in Drawing No.(…).

R222 Excavation of [5 m] diameter shaft in [alluvium] as m3


shown in the drawings. [The excavated material shall be
disposed at the designated location within the site as
shown in Drawing No.(…)].

R231 Excavation of [5 m x 10 m x 30 m long storage m3


chamber] in rock Class [A to D] as shown in the
drawings.

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR156 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Enlarge Tunnel Section

Rate for enlarge tunnel section shall be deemed to


include all necessary tunnel support and backfilling with
[grade C30 concrete] to design profile after completion
of tunnel work.

R241 Assembly and dismantle yards. sum

R242 Vehicle turnings. sum

R243 Switching stations. sum

R244 Transformer bays. sum

R245 Pump sumps. sum

Drilling

Rate for drilling shall be deemed to include installation


of pipe as shown in the drawings.

R251 [50 mm] diameter probe ahead hole in [rock]. m

R252 [50 mm] diameter drain hole in [rock]. m

R253 [50 mm] diameter grout hole in [rock]. m

Grouting

R260.1 Cement. t

R260.2 Polyurethane. t

R300 IN SITU LINING

Shotcrete

Refer Specification clause (…) for shotcrete work.

R311.1 [100 mm] thick plain shotcrete to [smooth finish]. m2

R311.2 [50 mm] thick plain shotcrete to [rough finish]. m2

R312.1 [150 mm] thick [mesh] reinforced shotcrete to [smooth m2


finish].

R312.2 [100 mm] thick [steel fibre] reinforced shotcrete, [30 m2


kg/m3] to [fair finish].

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR157 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

In situ Concrete

Rate for in situ concrete shall be deemed to include


contact grouting at tunnel crown.

R320 Reinforced concrete [grade C35A] to [tunnel] lining m3


[with early strength admixtures] as per Specification
clause (…).

Reinforcement

Rate for reinforcement shall be deemed to include labour


for cutting, bending, and placing.

R331 Mild steel bars [6 mm to 16 mm]. t

R332.1 High tensile bars [6 mm to 16 mm]. t

R332.2 High tensile bars [20 mm to 32 mm]. t

R333 High tensile steel fabric [mesh A252 (A8), 3.95 kg/m2]. m2

R334 [Stainless steel] fabric [mesh A393(A10), 6.16 kg/m2]. m2

Formwork

Rate for formwork shall be deemed to include travel


steel form for all inclination, alignment, and end form to
construction joints.

R340 Smooth finish to [tunnel] lining. m2

Water Proofing

R351.1 [230 mm] wide rubber waterstop. Rate to include cutting m


and jointing of waterstops and provision of special
fittings at angles and junctions.

R351.2 [250 mm] wide PVC waterstop. Rate to include cutting m


and jointing of waterstops and provision of special
fittings at angles and junctions.

R352.1 [1 mm] thick [HDPE] membrane. m2

R352.2 [2 mm] thick [PVC] membrane. m2

R352.3 [Water proofing paint] as per Specification clause (…). m2

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR158 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

R400 PREFORMED LINING

Preformed Concrete Lining

Rate for preformed concrete lining shall be deemed to


include reinforcement, formwork, packing, caulking,
joint seal, finishes, and preformed threaded grout holes.

R411 [5 m] internal diameter x [200 mm] thick segmental ring m


as shown in Drawing No.(…).

R412 [200 mm] thick invert segment as shown in Drawing m


No.(…).

[Steel Lining, Cast Iron Lining and Ductile Iron


Lining]

Rate for [steel, cast iron and ductile iron] lining shall be
deemed to include cutting and jointing, internal and
external corrosion protection, stiffeners, fish tails, and
purpose-made holes for annulus grouting.

R420 [50 mm thick, grade 50B] steel lining of [3.5 m] internal m


diameter as per Specification clause (…).

R430 [40 mm thick, grade 600/3] cast iron lining of [4 m] m


internal diameter as per Specification clause (…).

R440 [30 mm thick, grade 500/7] ductile iron lining of [5 m] m


internal diameter as per Specification clause (…).

Annulus Grouting

R450 Annulus grouting with [cement grout of w/c ratio m3


0.45:1] under [2] bars pressure.

Water Proofing

R460 [1 mm] thick [HDPE] membrane. m2

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR159 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

R500 TUNNEL SUPPORT

Steel Rib

Rate for steel rib shall deemed to include all necessary


accessories such as tie rods, end plate, bolts and nuts.

R510.1 Steel rib [H100 x 100 x 8 mm thick, 17.2 kg/m]. t

R510.2 Steel rib [H125 x 125 x 9 mm thick, 23.8 kg/m]. t

Lagging

R521 C-channel [C100 x 50 x 4 mm thick, 5.87 kg/m]. t

R522 Steel plate [5 mm] thick. t

R523 Mesh fabric [A142 (A6), 2.22 kg/m2]. Rate to include m2


lapping and mesh pin.

Bolting

Rate for bolting shall be deemed to include all


accessories and ancillary work as shown in the
drawings. Exposed elements shall be protected against
corrosion.

R531.1 [T20 mm dia.] rock dowel of [1.5 m] long. nr

R531.2 [T25 mm dia.] rock dowel of [2 m] long. nr

R532.1 [T25 mm dia.] rock bolt of [2 m] long. nr

R532.2 [T25 mm dia.] rock bolt of [3 m] long. nr

R533 Pull out test for [T25 mm dia. rock bolt x 3 m long] with nr
test load of [200 kN].

Shotcrete

R541 [50 mm] thick plain shotcrete as per Specification clause m2


(…) to [rough finish].

R542 [150 mm] thick [steel fibre reinforced shotcrete (30 m2


kg/m3)] as per Specification clause (…) to [rough
finish].

Fibre Mortar

R550 [25 mm] thick fibre mortar as per Specification clause m2


(…) and as shown in the drawings.

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR160 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Forepoling

R561 Forepoling with [T25 mm] diameter dowel bar of [12 m] nr


long as shown in the drawings.

R562 Forepoling with [100 mm] diameter canopy tube of [4 nr


mm] thick and [12 m] long as shown in the drawings.

R600 BACKFILL

R611 Backfill invert with concrete [grade C20]. m3

R612 Backfill invert with plain shotcrete. m3

R613 Backfill invert with mortar [1:3]. m3

R614 Backfill invert with [cement grout 0.45:1]. m3

R615 Backfill invert with tunnel muck. m3

R621 Backfill behind lagging with concrete [grade C20]. m3

R622 Backfill behind lagging with plain shotcrete. m3

R623 Backfill behind lagging with mortar [1:3]. m3

R624 Backfill behind lagging with [cement grout 0.45:1]. m3

R631 Backfill [adit entrance] with concrete [grade C30] as m3


shown in Drawing No.(…).

R700 INSTRUMENTATION

Rate for instrumentation shall include all provision as


expressly required in Specification clause (…).

R710 Convergence measurement. nr

R720 Settlement measurement. nr

R731 Stress measurement with strain gauges. nr

R732 Stress measurement with pressure cells. nr

R733 Inclinometer. nr

R734 Stress measurement with pneumatic piezometer. nr

Page Total carried to Summary of Class R

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR161 of BQR173
CLASS R
Tunnel Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class R: Tunnel Work

Page BQR1

Page BQR2

Page BQR3

Page BQR4

Page BQR5

Page BQR6

Page BQR7

Total of Class R carried to Grand Summary

Class R: Tunnel Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQR162 of BQR173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

S100 TRACK FOUNDATION

Item for track foundation shall be deemed to include


supplying and laying of materials.

Subgrade Preparation

S111 Earth material to receive track foundation. Rate to m2


include scarifying, levelling, and compaction of the top
300 mm of the subgrade.

S112 Hard material to receive track foundation. Rate to m2


include scarifying, levelling, and compaction of the top
300 mm of the subgrade.

S113 Rock material to receive track foundation. m2

S120 [One layer of 5 mm thick waterproofing membrane] as m2


per Specification clause (….).

S130 Geotextile of the [non-woven] type as per Specification m2


clause (….).

S140 Granular material with a [CBR value of more than 30, m2


complying with Type C] of Specification clause (…..) in
[100 mm] thick.

S150 [Crushed aggregates] for sub-ballast complying with m3


Specification clause (…..).

S160 [Crushed granite] for ballast complying with m3


Specification clause (…..).

S200 SUPPLYING

Item for supplying shall be deemed to include delivery of


components to the Site.

S210 Flat bottom rails, [reference 113A] as per Specification t


clause (….), mass [56 kg/m].

S220 Check and guard rails, mass 0.10 tonne/m as per t


Specification clause (….).

S230 Conductor rails as per Specification clause (….). t

S240 Twist rails. nr

Page Total carried to Summary of Class S

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS163 of BQS173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Sleepers

Item for supplying sleepers shall be deemed to include


fittings attached by the supplier.

S251 […] x […] x [….] mm thick Grade A heavy hardwood nr


timber sleepers.

S252 […] x […] x [….] mm thick Grade [30] concrete nr


sleepers with profile as shown in Drawing No. (....).

Fittings

Item for supplying fittings shall be deemed to include


fixings, keys, clips, bolts, nuts, screws, spikes, ferrules,
track circuit insulators, pads, conductor rail insulator,
and packing.

S261 Type (….) chairs as per Specification clause (…). nr

S262 Type (….) baseplates as per Specification clause (…). nr

S263 [Pandrol] rail fastenings, type [….] as per Specification nr


clause (…).

S264 Type (….) plain fishplates as per Specification clause nr


(…).

S265 Type (….) plain insulated fishplates as per Specification nr


clause (…).

S266 Conductor rail insulators as per Specification clause nr


(….).

S267 Conductor rail side ramps. nr

S300 SUPPLYING

Item for supplying shall be deemed to include delivery of


components to the Site.

S310 Type […..] turnouts as shown in Drawing No. (…….). nr


Rate to include timbers, fittings, and check rails.

S320 Type […..] diamond crossing as shown in Drawing No. nr


(…….). Rate to include timbers, fittings, and check rails.

Page Total carried to Summary of Class S

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS164 of BQS173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Sundries

S331 Buffer stops, approximate weight 2.5 tonnes of steel rail nr


and timber sleeper construction.

S332 Wheel stops. nr

S333 Lubricators. nr

S334 Switch levers. nr

S335 Conductor rail guard boards. nr

S400 LAYING

Item for laying shall be deemed to include work carried


out after delivery of components to the Site or where
track is not to be supplied by the Contractor, to the
location stated in Specification clause (……).

Flat Bottom Rails

S411 Plain track, rail reference 113A, mass 56 kg/m and m


prefabriacted in [10m] length, fish plated joints on
timber sleepers.

S412 Form curve in plain track radius not exceeding 300 m, m


welded joints on concrete sleepers

S413 Form curve in plain track radius exceeding 300 m, m


fishplated joints on timber sleepers.

S414 Turnouts type […..] as shown on Drawing No. (….), nr


length [….] m, fishplated joints on timber sleepers.

S415 Diamond crossings type […..] as shown on Drawing No. nr


(….), length [….] m, fishplated joints on timber sleepers.

S416 Welded joints by quick thermit process as per nr


Specification clause (….).

S417 Spot re-sleepering. nr

Check and Guard Rails

S421 Rail. m

S422 Length ends. nr

S423 Side ramps. nr

S424 Welded joints by quick thermit process as per nr


Specification clause (….).

Page Total carried to Summary of Class S

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS165 of BQS173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Conductor Rails

S431 Rail. m

S432 Length ends. nr

S433 Side ramps. nr

S434 Welded joints. nr

Sundries

S441 Buffer stops, approximate weight 2.5 tonnes of steel rail nr


and timber sleeper construction.

S442 Wheel stops. nr

S443 Lubricators. nr

S444 Switch levers, rate to include laying check rails. nr

S445 Conductor rail guard boards. m

S500 DISMANTLING

Dismantling shall include taking up, lifting, packing and


slewing, and to include opening out, packing and boxing
in with ballast and insertion of closure rails.

Flat Bottom Rails

S511 Plain trackrail reference 113A, mass 56 kg/m, fish plated m


joints on timber sleepers. Dismatled material shall be
stored at [storage yard at main site office].

S512 Turnouts type […..], length [….] m, fishplated joints on nr


timber sleepers. Rate to include checkrail, guardrail, and
conductor rails.

S513 Diamond crossings type […..], length [….] m, fishplated nr


joints on timber sleepers. Rate to include checkrail,
guardrail, and conductor rails.

S520 Check and guard rails. m

S530 Conductor rails. m

Page Total carried to Summary of Class S

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS166 of BQS173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Sundries

S541 Buffer stops, approximate weight 2.5 tonnes of steel rail nr


and timber sleeper construction

S542 Wheel stops. nr

S543 Lubricators. nr

S544 Switch levers. nr

Page Total carried to Summary of Class S

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS167 of BQS173
CLASS S
Rails Track

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class S: Rail Tracks

Page BQS1

Page BQS2

Page BQS3

Page BQS4

Page BQS5

Total of Class S carried to Grand Summary

Class S: Rail Tracks


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQS168 of BQS173
CLASS T
Miscellaneous Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

T100 FENCES

Items for fences shall be deemed to include excavation,


preparation of surfaces, disposal of excavated material,
upholding sides of excavation, backfilling, concrete,
formwork, reinforcement, and all posts and foundation.

T110 [1200 mm wide x 25 mm thick close boarded wrot finish m


Grade A balau heavy hardwood complete with 150 mm x
150 mm posts at 3 m centres, 1.80 m high] as shown in
Drawing No. (……).

T120 [40 x 40 x 2.6 mm thick square mild steel hollow section m


at 100 mm centres bothways welded as a frame 1.5 m
high with 80 x 80 x 3.6 mm thick post at 2 m centres] as
shown in Drawing No. (….).

T130 [3 mm] diameter [PVC-coated galvanised] mild steel wire m


of [50 mm] square mesh, [2 m] overall height chain link
fencing complete with post at [3 m] centres as shown in
Drawing No. (….). Rate to include all posts, raked angle,
straining wires, barb wires, concrete kerbs, and
foundations as shown.

Barb/Bladed Wire

T140 [12 SWG galvanised mild steel] barbed/bladed wire m


fencing; [1.2 m] high with [50 x 50 x 4.5 mm thick] mild
steel angle as post planted in mass concrete bases at [2.0
m] centres and including [150 mm high] concrete kerb as
shown in Drawing No. (…..).

T150 [Brick and mild steel grille fencing; comprising 500 mm m


high, 115 mm thick brick wall with concrete coping
rendered with 19 mm thick cement sand plaster; 230 mm
x 230 mm brickwork post; mild steel decorative grille
fencing 750 mm high; framed and welded together, all on
and including reinforced concrete strip footing as shown
in Drawing No. (.....)].

T200 GATES

Items for gates shall be deemed to include excavation,


preparation of surfaces, disposal of excavated material,
upholding sides of excavation, backfilling, concrete,
formwork, reinforcement, posts and foundations, hinges,
bolts, rollers, lockplates, and all necessary welding.

T210 Double leave Grade A balau heavy hardwood gate [2400 nr


mm x 1500 mm high] overall complete with [100 mm x
100 mm] hardwood posts and ironmongery as shown in
Drawing No. (……).

Page Total carried to Summary of Class T

Class T: Miscellaneous Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQT169 of BQT173
CLASS T
Miscellaneous Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

T220.1 Double leave mild steel gate [3000 mm x 1500 mm high], nr


consisting of [50 x 30 x 3.2 mm thick] rectangular hollow
section as frame welded together with [30 x 30 x 2.6 mm
thick] square hollow section; including painting,
ironmongery; fixing with hinges on lugs built in masonry
backing as shown in Drawing No. (........).

T220.2 Single leaf mild steel automatic gate [3000 mm x 1500 nr


mm high], consisting of [50 x 30 x 3.2 mm thick]
rectangular hollow section as frame welded together with
[30 x 30 x 2.6 mm thick] square hollow section; including
painting, ironmongery; fixing with hinges on lugs built in
masonry backing as shown in Drawing No. (........). Rate
to include motor and automatic control system.

Chain Link

Item for chain link shall be deemed to include all posts,


raked angle, straining wires, barb wires, kerbs where
applicable and their foundation.

T230 [3 mm] diameter [PVC-costed galvanised mild steel wire nr


of 50 mm square mesh, [3.0 m wide x 2.5 m overall
height double leave chain link gate with 60.3 mm OD x 5
mm thick circular hollow section as frame as shown in
Drawing No. (.....). Rate to include all posts, hinges, bolts,
lock plates, angle braces, barb wires, all necessary
welding and foundations as shown.

T240 Double leave galvanised barbed wire [2400 mm x 2000 nr


mm high] gates; comprising [50 x 50 x 4.5 mm thick]
mild steel angle frame as shown in Drawing No
(………..).

T250 Double leave gate, [2400 mm x 1200 mm high] with 100 nr


mm x 100 mm Grade A wrot finish heavy hardwood as
frame and 12 SWG galvanised barbed wire as shown in
Drawing No. (…….).

Page Total carried to Summary of Class T

Class T: Miscellaneous Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQT170 of BQT173
CLASS T
Miscellaneous Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

T300 SIGNAGES FOR BUILDINGS AND TANKS

Rate for internal and external signages shall be deemed


to include fixing complete.

Painting of Logos

Supply and paint [SYABAS] logo and lettering for [water


tank] at [Taman Gembira Cheras] as detailed in the
drawings and the following:

T310.1 Paint [SYABAS] logo for [water tank] at [Taman nr


Gembira Cheras] as per Specification clause (……….)
and detailed in Drawing No. (……….).

T310.2 Paint [TNB] logo for sub-station as per Specification nr


clause (……….) and detailed in Drawing No. (……….).

External Signages

T320 Paint lettering for [water tank] at [Taman Gembira nr


Cheras] as per Specification clause (……….) and
detailed in Drawing No. (……….).

Internal Signage
Internal signage shall be as per Specification clause
(……).

T330.1 Laboratory. nr

T330.2 Work manager room. nr

T330.3 Control room. nr

T400 BEARING PADS

Bridge bearing
Supply and install the following bearings inclusive of
mortar grout, epoxy mortar, and all temporary work.

Roller

T411.1 Single roller bearing as shown in Drawing No. (…..). nr

T411.2 Multiple roller bearing as shown in Drawing No. (…..). nr

Page Total carried to Summary of Class T

Class T: Miscellaneous Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQT171 of BQT173
CLASS T
Miscellaneous Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Slide

T412.1 Plane sliding bearing as shown in Drawing No. (…..). nr

Rocker

T413.1 Cylindrical rocker bearing as shown in Drawing No. nr


(…..).

T413.2 Spherical rocker bearing as shown in Drawing No. (…..). nr

Plain rubber

T414 [300 x 300 x 60 mm thick] plain rubber bearing as shown nr


in Drawing No. (…..).

Laminated rubber

T415 [300 x 300 x 80 mm thick] elastomer laminated rubber nr


bearing as shown in Drawing No. (…..).

Pot bearing

T416.1 Sliding guided pot bearing as shown in Drawing No. nr


(…..).

T416.2 Free standing pot bearing as shown in Drawing No. nr


(…..).

Other bearing

T424 300 mm wide x 60 mm thick plain rubber bearing for nr


joint between dome roof and wall as shown in Drawing
No. (…..).

Page Total carried to Summary of Class T

Class T: Miscellaneous Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQT172 of BQT173
CLASS T
Miscellaneous Work

Item No. Code No. Description Unit Qty. Rate Amount (RM)

Summary of Class T: Miscellaneous Work

Page BQT1

Page BQT2

Page BQT3

Page BQT4

Total of Class T carried to Grand Summary

Class T: Miscellaneous Work


\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office Page BQT173 of BQT173

Anda mungkin juga menyukai