BPSP

Top of DAM UD m 485.00


MWL UD m 482.00
FRL UD m 480.00
MDDL (Gen) UD m 460.83
MDDL (Irri) UD m 456.50
Intake Invert Level m 439.00
Pressure Shaft (HRT) Dia m 8.30
Pressure Shaft (HRT) Length m 847.00
Penstock Dia m 5.90
Penstock Length m 112.00
Dead Storage UD m 8.34
Live Storage UD m 13.49

Top of DAM LD m 346.00


MWL LD m 343.00
FRL LD m 341.00
MDDL LD m 325.00
Outlet Invert Level m 306.00
TRT (dia) before bifur m 7.00
TRT (Length) before bifur m 100.00
TRT (dia) after PH m 9.80
TRT (Length) after PH m 628.00
Dead Storage LD m 8.34
Live Storage LD m 13.49
Power House Overt Level m 330.00
Errection Bay /M/c hall floor Level m 308.00
Generator-Motor Floor Level m 303.00
Pump-Turbine Floor Level m 298.00
Main Inlet Valve (MIV) Floor Level m 292.00
C/L of penstock Level m 293.00
Drainage & Dewatering Gallery Floor Level m 287.00

Transformar Hall Overt Level m 322-324


Transformar Hall Floor Level m 308.00

Static Head
a) Maximum: m
b) Normal: m
c) Minimum: m
Operating Head range as Turbine
a) Maximum Head m
b) Rated Head m
c) Minimum Head m
Turbine Basic Data
a) Rated Output at rated head of 126.5 m
b) Turbine Output at 10% overload operation
c) Specific Speed
d) Rated Speed
e) Max. Discharge at normal net head 126.5 m :