Anda di halaman 1dari 1

ref.

600lbs Indoor Electromagnetic


Lock VIS-ML600LED
Technology Within Your Reach

Scan the QR code to watch


Installation User Guide the installation video

(Indoor Models) https://youtu.be/xSwbvApnXjw


12/24 VDC U1 Bracket For
General Installation Glass Door
Power
Door Cable Wire
Frame Door Frame

Glass
Door
Mounting Plate

Self-tapping Screw x10


EM Lock EM Lock
Out Swing
Door
Out-Swing

DSU Bracket For Cover ZL Bracket For


Glass Frame & Glass Door Screw In-Swing Door With Cover

Glass CSK M8 x16


Frame

Door
Frame
EM Lock
EM Lock

Fixing Screw
x2 M4 Set
In-Swing PCB Cover Door Screw

Armature In-Swing
Ø8 AL Bush
Glass Screw
Door
Mag. Ctc.
ZL Bracket For
LS Bracket For Magnet In-Swing Door
Out-Swing Door Self-tapping Screw

Door Anti Tamper


Frame Nut x2 Self Lock Pin Door
M3x12 - 2pcs Frame
EM Lock

Allen Wrench Rubber


Washer Sexnut Bolt Door
P/H MC Screw
M4 x 8
EM Lock
Out-Swing
Metal
Door In-Swing

Armature Plate Washer

General Installation Steps & Maintenance


1. Drill the armature plate holes in the door using the sticker template provided.
2. Attach the armature plate to the door with the hardware provided as per the illustration.
3. With the door closed, mark the door frame at the edge of the armature in order to properly align
the electromagnet to the armature.
4. Attach the mounting plate to the door frame using the self-tapping screws provided. Align the
mounting plate with the mark from the previous instruction.
5. Insert the wires through the hole in the mounting plate and into the electromagnet unit. Attach the
electromagnet unit to the mounting plate with the Allen head fixing screw.
6. Screw in the anti-tamper nuts to prevent unauthorized access and to prevent the fixing screw from
loosening over time.
7. Connect the power wires according to the instruction and test the system.
8. It is recommended that to apply a light coat of silicon lubricant to the mating surface on a monthly
basis to prevent rust.

Trouble Shooting
1. Sensor not functioning
- Improper attachment of electromagnet and armature plate
- Modification of the PCB
2. Door not locked
- Incorrect wiring or no power from power supply
3. Reduced holding force
IMPORTANT!
- Poor contact of electromagnet and armature.
Set the jumper position according to the power input
correctly before switch ON the power - Be sure armature is loose enough that it can fully contact electromagnet along the entire length.
- Mating surface is dusty or damaged.
- Improper input voltage or wire size.

Disclaimer: VISIONIS reserve the right to go ahead with any modifications of models or features or price without forewarning. All the sales@visionistech.com
information and specifications stated in this document are current at the time of publication. Attention: We are not responsible for the
improper installation of this kit. If you are not handy with electrical equipment you should contact a professional electrician. You will also
need to check with your local Fire authority to see if you need anything else to comply with local Fire Codes. We are not responsible for www.visionistech.com
any damage or fees that can occur.

Anda mungkin juga menyukai