Anda di halaman 1dari 101

Fighting Disease with Electronics

ACCESSORIES
CARDIOLOGY
2 0 1 3 / 2 0 1 4
2 Introduction www.nihonkohden.net

Introduction

Dear Customer,

For more than 60 years NIHON KOHDEN has been one of Japan’s leading players in medical technology development and
manufacturing and has subsidiaries and representative offices in Europe, the US, as well as in the Middle and Far East.

“Fighting Disease with Electronics“ – our corporate philosophy – reflects the high standards we have set ourselves in combating
disease by developing medical systems, contributing to higher quality of life for patients.

Our large product range of accessories and consumables is known for its outstanding quality, ease of use and reliability. Please
note, that only the use of original NIHON KOHDEN approved accessories and consumables guarantee optimal examination results
and make an important contribution towards ensuring that your device will continue to function impeccably and reliably even in
years to come, while preserving the device’s features and functional capabilities.

As your partner in cardiology, NIHON KOHDEN provides only tested and approved product solutions from standard vital
signs parameter such as ECG, SpO2 , NIBP or Temperature to specific parameters like Capnography or IBP Measurement. Our
commitment to ensure continually highest quality allows you the best care of your patients and enhances your ECG, AED/TRN and
Defibrillator performances.

NIHON KOHDEN invites you to discover the quality and features of our complete accessories and consumables portfolio in this
catalogue. Call today for more information or order directly!

Best regards,

NIHON KOHDEN EUROPE GmbH

Kristin Baar
Product Manager Accessories & Consumables
3 Content www.nihonkohden.net

Accessories & Consumables Cardiology

User Guide 6

Product Innovation & Smart Cable TM Technology 7

Highest Safety and Quality Standards 8

Quick Guide Electrocardiographs, Defibrillators, AED/TRN 9

1 ECG Measurement 10

Typical Arrhythmia Waveforms 11

12
1.1 ECG Cables

1.1.1 ECG 10-Lead Cable 13


1.1.2 ECG 12/15-Lead Cable 14
1.1.3 ECG Veterinary 5-Lead Cable 15
1.1.4 Additional Cable Accessories 15

1.2 ECG Electrodes 16

1.2.1 Clip Electrodes 17


1.2.2 Chest & Plate Electrodes 18
1.2.3 Tab Electrodes 19
1.2.4 ECG Electrodes for Adults 20
1.2.5 ECG Electrodes for Children, Infants & Neonates 21
1.2.6 ECG Electrode Adapter 21

1.4 ECG Batteries 22

1.5 ECG Paper 24

1.6 Additional ECG Accessories 27

2 Accessories for Defibrillators 30

2.1 Defibrillator Batteries & Battery Charger 31

2.2 Defibrillator Paper 33

2.3 Defibrillator Bags 35


4 Content www.nihonkohden.net

2.4 Disposable Defibrillator Pads 37

2.4.1 Disposable Pads with NIHON KOHDEN Connector 38


2.4.2 Disposable Pads with R2 Connector 39

2.5 Paddle Electrodes 40

2.5.1 Internal Paddle Electrode with Discharge Button for Series TEC-8300 41
2.5.2 Internal Paddle Electrode with Discharge Button for TEC-5500/7700 42
2.5.3 Neonate Paddle Adapter for TEC-5500/7700 42

2.6 ECG Measurement 43

Typical Arrhythmia Waveforms 44

2.6.1 ECG Cables 45

2.6.1.1 ECG Cables for TEC-8300 46

2.6.1.1.1 ECG 3/6-Lead Cables 47


2.6.1.1.2 ECG 10-Lead Cables 48

2.6.1.2 ECG Cables for TEC-5500 & TEC-7700 49

2.6.1.2.1 ECG 3-Lead Cables 50


2.6.1.2.2 ECG 5-Lead Cables 51
2.6.1.2.3 Further Defibrillator Connection Cables 52

2.7 ECG Electrodes for Defibrillators 53

2.7.1 ECG Electrodes for Adults 54


2.7.2 ECG Electrodes for Children, Infants & Neonates 55

2.8 SpO2 Measurement 56

2.8.1 SpO2 Cables 57

2.8.2 SpO2 Probes 59

2.8.2.1 Reusable SpO2 Probes 61


2.8.2.2 Disposable SpO2 Probes 63
2.8.2.2.1 Disposable SpO2 Probes 24 pcs/box - cable length: 0.8 m 63
2.8.2.2.2 Disposable SpO2 Probes 24 pcs/box - cable length: 1.6 m 64
2.8.2.2.3 Disposable SpO2 Probes 5 pcs/box - cable length: 0.8 m 64
2.8.2.2.4 Disposable SpO2 Probes 5 pcs/box - cable length: 1.6 m 66
5 Content www.nihonkohden.net

2.9 ETCO2 Measurement (Capnography) 68

ETCO2 Selection Guide 69

ETCO2 Measurement Overview 70

2.9.1 ETCO2 Mainstream 71

2.9.1.1 Intubated Expired ETCO2 72


2.9.1.2 Intubated Expired and Inspired ETCO2 - “Opening a New Era in Capnography“ 73
2.9.1.3 Intubated and Non-Intubated Expired ETCO2 CapOne - “Opening a New Era in Capnography“ 74

2.10 Temperature Measurement 76

2.10.1 Standard Temperature Measurement 77


2.10.2 Measurement of 2 Additional Temperatures 77

2.11 NIBP Measurement (Non-invasive Blood Pressure) 78

2.11.1 NIBP Air Hoses 79


2.11.2 Reusable NIBP Cuffs - NEW YAWARA CUFF 2 80
2.11.3 Disposable NIBP Cuffs 82
2.11.3.1 Disposable NIBP Cuffs for Infants & Children 82
2.11.3.2 Disposable NIBP Cuffs for Adults 83

2.12 IBP Measurement (Invasive Blood Pressure) 84

2.12.1 IBP Transducer Cable with Direct Connection 85


2.12.2 IBP Transducer Cable with Adapter Cable K952 86

2.13 Portable CPR 88

2.14 Additional Defibrillator Accessories 90

3 Accessories for AED & Training Unit 92

3.1 Accessories for AED Units 96


3.2 Accessories for AED Training Unit TRN-2100K 96

Accessory Order Form 97

Index as per Supply Code 98

Index as per Model Code 100


6 User Guide www.nihonkohden.net

User Guide
Care of Environment
NIHON KOHDEN is making every possible effort to ensure that the actions of the company and its employees contribute to
preserving the environment. In order to conserve paper resources, we decided a more environment friendly approach which allows
us to update the catalogue more frequently in the future. Therefore the new accessories and consumables catalogue was designed
for view on your computer. It allows you to zoom pictures in order to see more details of the product. If you need indeed certain
chapters in print version, you can easily select and print them.

Find the right accessories in the catalogue


You do not know exactly which article you need for your examination?

Following this user guide you will find the content of this catalogue which is organized into parameter categories. In a particular
category you will see a list of accessories and consumables with corresponding supply codes, model codes, descriptions and
pictures. If you are not sure if one of the listed products will fit to your requirements, please contact us or one of our regional
representatives.

You already know the article that you need for your examination?

In the index of the catalogue , from page 98 to page 99, the articles are listed alphabetically as per supply code; page 100, the products are
listed alphabetically as per model code. They will help you to find directly the according product page.

If you are using the PDF version, simply use the “search function” of this by entering the description, supply or model code.
Or just click on the related chapter on the left side of the document.

Order information
To order NIHON KOHDEN accessories and consumables or to get more information, please refer to the indicated regional
NIHON KOHDEN representatives below.

For your convenience, we have a printable order form at the end of this catalogue so that you can fax in your order directly or
mail/e-mail it to us. Please make sure to fill out all requested information as well as the required supply code and according
quantity. Please check the general terms and conditions including delivery time, payment and general warranty with your
responsible regional NIHON KOHDEN representatives:

For Germany, Austria, Switzerland and Benelux For France


NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland NIHON KOHDEN FRANCE SARL
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland 8, rue François Delage, 94230 Cachan, France
Fax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de Fax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.fr
For Spain and Portugal For Italy
NIHON KOHDEN IBERICA S.L. NIHON KOHDEN ITALIA S.r.l.
C/Ulises, 75A, 28043 Madrid, Spain Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +34 91 300 46 76, E-Mail: info@nkib.es Fax: +39 (0) 35-232546, E-Mail: info@nkitaly.com
For United Kingdom For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN UNITED KINGDOM Ltd. NIHON KOHDEN EUROPE GmbH
Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Surrey KT6 7EL, United Kingdom Fax: +49 (0) 6003/827-599, E-Mail: info@nke.de
Fax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk
7 Product Innovation & Smart Cable™ Technology www.nihonkohden.net

Synthesized 18-lead ECG - Identify Invisible Ischemia -


A New Technology for More Informative ECG Exam

What is Synthesized ECG ?

Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R)
and back leads (V7, V8, V9). The measurement procedure is the same as the standard 12-lead ECG but more information can be obtained.
18-lead synthesized ECG is expected to be useful in detecting right side and posterior infarction.

The most common ECG exam is the standard 12-lead ECG. It is simple to measure, has low burden on the body, and observing the heart
from these 12 directions provides a lot of information which has a wide range of clinical applications.

However, some areas, especially pathological change in the right ventricle and the posterior wall cannot be observed from the
12-lead ECG. In order to actually measure the right chest (V3R, V4R, V5R) and back (V7, V8, V9) areas, it is necessary to use different elec-
trode positions than the standard 12-lead ECG. In particular,
electrodes must also be attached to the patient’s back so that V1 V2 V3 V1 V2 V3
syn-V3R
normal suction cup electrodes cannot be used. Also, the pati-
V4 syn-V4R V4
ent must be turned over in some cases and in an emergency it is
often difficult to use back electrodes. This complicates the exam pro- V5 V5

cedure. Synthesized 18-lead ECG uses the 12-lead ECG waveforms to syn-V5R
V6 V6
mathematically derive the waveforms of the right chest leads (V3R,
V4R, V5R) and back leads (V7, V8, V9).
syn-V7
syn-V8
syn-V9

Standard 12-lead ECG Synthesized 18-lead ECG


Synthesized right side leads (V3R-V5R) and
synthesized back leads (V7 -V9) are added

NIHON KOHDEN - Smart Cable™ Technology


A Cost-Effective Solution to Modular Monitoring
With NIHON KOHDEN Smart Cable Technology, you will get complete mo-
dular flexibility at a significantly reduced cost and without all of the incon-
venience associated with traditional modular systems. Smart CableTM
technology miniaturizes circuits found in traditional modules and em-
beds that circuitry into the cable. When you plug a Smart CableTM into
a MULTI connector, it automatically detects the type of parameter and
starts measuring.
Smart Connector Technology is available for the following parameters:
= Available – = N/A Defibrillator Patient Monitors

Version 08/2013; Subject to


change without notice Current Products Older Products

Parameter Series TEC-8300 BSM-1700 PVM-2700 BSM-3000 BSM-6000 BSM-9100 BSM-2300

initial SW initial SW SW-V.03-30 SW V.04-12 SW V.04-12 SW-V.13-05 SW V.04-31

Flo Trac (APCO) – – – –


BISx Bispectral Index – –
with YJ-671P with YJ-671P with YJ-230P
BISx remarks – – – –
via JA-69xP (DAU) via AUX port only
Dual SpO₂ (Second SpO2) – –
via JA-69xP (DAU) –
IBP (Invasive Blood Pressure)
only PVM-2703
CO (Cardiac Output) – – –
EtCO₂ (Capnography)
with PVM-2703
TEMP (Temperature) – – – –
RESP (Respiration) – – – – –
FiO₂ (Fraction of inspired oxygen) – – – – –
8 Highest Safety and Quality Standards www.nihonkohden.net

Highest Safety and Quality Standards


Comprehensive quality assurance systems ensure that each of the more than 4,000 NIHON KOHDEN staff members
makes his/her contribution towards development, manufacture, marketing and customer services such that
maximum product quality is guaranteed.

NIHON KOHDEN is certified according to ISO 9001, ISO 13485 and ISO 14001.

NIHON KOHDEN designs and manufactures medical equipment in conformity with the standards of IEC 60601-1
(Medical Electrical Equipment: General Requirements for Safety).

NIHON KOHDEN products have earned a reputation for quality and long life. One reason is that all export products
and major components are manufactured in our own ISO 9001 and IEC 13485 certified factories.

In 1984, NIHON KOHDEN implemented a comprehensive companywide quality system, IQC – Integrated Quality
Control. Under this system, quality begins at the earliest stage of every product’s life. Our IQC applies to the entire
manufacturing process, from the planning stage through product development, design, parts procurement,
production, inspection, storage, sales, distribution and after-sales support. IQC also involves nearly every employee.

Our rigid test procedures are structured to exceed the provisions of the GMP, Good Manufacturing Practice, codes
enforced by the US Food and Drug Administration. NIHON KOHDEN also has 130 in-house quality control inspection
staff to ensure that standards are implemented and maintained in every department of the company.

IQC extends beyond production and into sales and support at each subsidiary. This staff is responsible for ongoing
contact with customers to determine their needs and making sure that these changing requirements are reflected
in new products. Service engineers are responsible for communicating any problem that may arise in the use of
NIHON KOHDEN products, and assuring the customers of NIHON KOHDEN’s commitment to their satisfaction.

In 1995, NIHON KOHDEN received ISO 9001 certification, the international standard for quality systems. In addition,
NIHON KOHDEN’s four manufacturing facilities in Japan are the first factories in the medical equipment industry to
be certified by the CSA, Canadian Standards Association, under their category certification system. Most products
sent to North America carry the CSA label.

Quality improvement is and always has been an ongoing process for NIHON KOHDEN.
Convince yourself of our expertise and the high quality of our products and services! Order directly!
9 Quick Guide NIHON KOHDEN www.nihonkohden.net

Quick Guide
Electrocardiographs, Defibrillators, AED/TRN

ECG-2350 ECG-2550 ECG-1500/1550 ECG-1150 ECG-1250 ECG-1350


ELECTROCARDIOGRAPHS

ECG-1950 ECG-9620 ECG-9320 ECG-9130/9132 ECG-9110 ECG-9020/9022

ECG-9010 ECG-8830 ECG-8820/8823 ECG-8420/8450 ECG-8350/8370 ECG-8330/8340

ECG-8240/8270 ECG-8110 ECG-6851


DEFIBRILLATORS

TEC-8321/8322/8332/ TEC-5521/5531 TEC-7721/7731 TEC-7621/7631 TEC-7511/7521/7531 TEC-7100/7200/7300


8342/8352

TEC-6100 TEC-2202/2203
AED/TRN

AED-2100 AED-2150/2151/2152 TRN-2100 TRN-2150


ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.

Number of false alarms


3000

2500 V. Rhythm

Tachy
2000
VPC Run
1500
VT

1000 Ext. Tachy

VF
500

0
Without ec1 With ec1
11 Cardiology › Typical Arrhythmia Waveforms www.nihonkohden.net

Typical Arrhythmia Waveforms


Premature Supraventricular Contractions
(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)

P P

• Narrow QRS (excluding aberrant ventriular conduction) • Slight ripples on the baseline • Irregular R-R intervals
• Ectopic focus higher than His-bundle • Non-compensatory pause • Inverted QRS complexes • Non-compensatory pause

Premature Ventricular Contractions (PVC) Ventricular Tachycardia (VT)

• Premature contractions • Bizarre and wide QRS complexes • Fast pulse rate greater than 100 bpm • 3 or more irregular beats
• Full compensatory pause • Frequent PVCs are serious • Needs emergency treatment and countershock • May progress to

Multi- focal PVC Ventricular Fibrillation (VF)

2
1
• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes
• Needs emergency treatment and countershock

Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II

P P P

• Consecutive PVCs • May progress to ventricular tachycardia • Sudden absence of QRS complexes (P-waves observed) • May progress
to cardiac arrest • Possibillity of Adams-Stokes syndrome
• Occasionally needs pacing

R-on-T PVC Third-degree (complete) atrioventricular (AV) block

P P P P P P P P P P P

• PVC on summit of T-wave • Bizarre and wide QRS complexes • Independent development of P-waves and QRS complexes • Possibility
of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing

Nihon Kohden products


which detect arrhythmia

Electrocardiographs / Defillibrators / Bedside Monitors

Diagnostic ECG Electrode Placement Heart Anatomy Cardiac Conduction Sytem


R and L electrodes should be placed just below 1. Inferior vena cava Atria His bundle 1 The sinoatrial (SA) node generates
the right and left clavicle. N and F electrodes should 2. Superior vena cava SA node a wave of electrical excitation.
15 16 17 3. Right atrium
1 2
Left 2 The excitation travels through
be placed on the lower edge of the rib cage, or at 2 bundle the internodal pathways to the
2 4. Tricuspid valve 3
branch
the level of the umbilicus at the mid-clavicular line. AV node atria and the atrial muscles contract.
7 7
5. Right ventricle Purkinje This is recorded as the P-wave.
8 14 6. Pulmonary valve Right
4
fibers 3 The excitation travels to the
Lead Electrode Placement 7. Pulmonary artery bundle 5

9 8. Pulmonary vein branch atrioventricular (AV) node.


C1 Fourth intercostal space at the 5

right border of the sternum 13 8 9. Left atrium 4 The excitation then travels through
10 Purkinje Ventricles the bundle of His and down through
3 7 10. Mitral valve fibers
C2 Fourth intercostal space at the R L 12 the right and left bundle branches.
right border of the sternum 6 11 11. Left ventricle R 5 The excitation terminates at the
12. Aortic valve
C3 Midway between locations C2 Purkinje fibers in the ventricles and
and C4 C1 C2 1 4 5
13. Coronary artery P T
the ventricular muscles contract. This
C3 C6 14. Aorta is the depolarization and is recorded
-------------
-------------

C4 At the mid-clavicular line in the


-------------------

-------------------

C4 C5
--------------------------

15. Brachiocephalic artery


--------------------------

Q S 1 as the QRS complex.


fifth intercostal space
Disposable accessories are intended for single use only, on one patient, during
18 a single examination! Do not re-use
16. Left common disposable accessories!
carotid artery 2 6 The ventricular muscles relax. This is
C5 At the anterior axillary line on the 17. examinations.
Left subclavian artery 3.4
Reusable accessories are intendedNfor repeated patient
F use on different patients during different Please make sure to clean reusable accessories 5
after each patient or and is recorded as
the repolarization
same horizontal level as C4 18. Descending aorta the T- wave.
between different applications to prevent or reduce the risk of cross infections! 6
C6 At the mid-axillary line on the
same horizontal level as C4 and C5
ECG Cables

ECG 10-Lead Cable

ECG 12/15-Lead Cable

ECG Veterinary 5-Lead Cable

Additional Cable Accessories


13 Electrocardiographs > ECG Cables www.nihonkohden.net

ECG 10-Lead Cable


Supply Code Model Description
K081 BJ-902D 10-Lead ECG Patient Cable, 4 mm banana plug (IEC), limb 3.4 m/chest 2.9 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs

K082 BJ-903D 10-Lead ECG Patient Cable, snap (IEC), limb 3.4 m/chest 2.9 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs

K079 BJ-901D 10-Lead ECG Patient Cable, 3 mm banana plug (IEC), limb 1.2 m/chest 0.7 m
For current products: ECG-1150/1250/1350/2350
Packing unit: 1 pcs

K093C BR-912D 10-Lead ECG Patient Cable, 4 mm banana plug (IEC), for input-box JC-901D,
for resting ECG, limb 1.2 m/chest 0.7 m
For current products: ECG-1550
Packing unit: 1 pcs

K093D BR-913D 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for resting ECG,
limb 1.2 m/chest 0.7 m
For current products: ECG-1550
Packing unit: 1 pcs

K093F BR-913E 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for stress test,
limb/chest 0.6 m
For current products: ECG-1550
Packing unit: 1 pcs

K096A 490933 Connection Cable for Patient Input-Box JC-901D, cable length: 2.0 m
For current products: ECG-1550
Packing unit: 1 pcs

K096B 669269 Connection Cable for Patient Input-Box JC-901D, cable length: 5.0 m
For current products: ECG-1550
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
14 Electrocardiographs > ECG Cables www.nihonkohden.net

ECG 12/15-Lead Cable


Supply Code Model Description
K093L BR-921D 15-Lead ECG Patient Cable, 3 mm banana plug (IEC), for input-box JC-901D,
for stress test, limb/chest 1.2 m
For current products: ECG-1550
Packing unit: 1 pcs

KB010 BR-202D 12-Lead Set (Electrode Leads: R,L,F,N,C1,C2,C3,C4,C5,C6), 4 mm banana plug


For current products: ECG-2550
Packing unit: 1 pcs
KB012 BR-202D XYZ-Lead Set, 4 mm banana plug
For current products: ECG-2550
Packing unit: 1 pcs
K118 Slide Clipper for Chest
For current products: ECG-2550
Packing unit: 1 pcs

K119 Slide Clipper for Limb


For current products: ECG-2550
Packing unit: 1 pcs

Supply Code Model Chest Lead Label Color Cable Length Cable Color For current Packing unit
products
KB01A BR-202D C1 red
KB02A BR-202D C2 yellow
KB03A BR-202D C3 green
KB04A BR-202D C4 brown
KB05A BR-202D C5 black 0.7 m white
KB06A BR-202D C6 violet
KB07A BR-202D CX1
KB08A BR-202D CX2 white
KB09A BR-202D CX3
KB10C red
1.2 m grey ECG-2550 1 pcs
KB11C yellow
KB12D green 1.4 m
KB13B 1.0 m
black
KB13D 1.4 m
KB14B yellow
KB15B red
KB16B blue 1.0 m white
KB17B orange
KB18B brown
KB19C white 1.2 m

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
15 Electrocardiographs > ECG Cables www.nihonkohden.net

ECG Veterinary 5-Lead Cable


Supply Code Model Description
K098 BJ-904D 5-Lead Veterinary ECG Connection Cable, 3 mm banana plug (IEC)
For current products: ECG-1950
Packing unit: 1 pcs

Additional Cable Accessories


Supply Code Model Description
K097 BM-901D Adapter for ECG Vacuum Equipment with 15 PIN Sub-D Connector to
input-box JC-901D
For current products: ECG-1500/1550
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Electrodes
Standard Electrodes Placements
It is important to prepare the skin before attaching the electrodes
by cleaning it and removing chest hair. After this please attach
the lead wire to the electrodes before placing them on the skin.
This avoids pain to the patient. Secure the lead wire to the skin
(stress loop) preventing moving of the lead wire and therefore
noise on the ECG signal.

Three electrodes Ten electrodes

Clip Electrodes

Chest & Plate Electrodes

Tab Electrodes

ECG Electrodes for Adults,


Children, Infants & Neonates

ECG Electrode Adapter


17 Electrocardiographs > ECG Electrodes www.nihonkohden.net

Clip Electrodes
Facts
The NIHON KOHDEN Fastclip ECG Electrodes allow a flexible application for routine work and emergency on every paediatric and adult
patient thanks to a simple adjustability of the clip pressure (clip size). A more comfortable handling is guaranteed due to different con-nectors for any
existing adapter type, a big contact area for reliable ECG measurements and easier cleaning after the measurement because of less asperity of the clip.
In addition to this IEC colored label sets are delivered with NIHON KOHDEN Fastclip ECG Electrodes.
By following the next steps, optimized derivations can be realized with NIHON KOHDEN Fastclip ECG Electrodes:

1.) Clean the according skin areas with alcohol in order to remove traces of dirt and oil on the skin.
2.) Apply a thin layer of CardioCream F010 on the cleaned skin areas and on the electrode part.
3.) Clip the electrode on the wrist or ankle. Adjust the electrode positon by sliding the electrode part according to the thickness of the limb.

Adjustability Easy to handle

strong wide
middle
weak narrow
spring
Contact pressure and position of elec- Opens more widly*, and round
trodes section can be adjusted accor- form brings easy to grip.
ding to patients΄ conditions. (*compared to the previous model)

Three types of connectors available Easy cleaning


Trench shape Raised dots

Tip Clip Snap


Any of tip, clip and snap type connector Previous model New model
is available. Less asperity easy cleaning.

Supply Code Description


H068A Fastclip ECG Electrode, 3 mm, child/adult, blue, adjustable size
For current products: all ECG/EEG
Packing unit: 4 pcs

H068B Fastclip ECG Electrode, 4 mm, child/adult, blue, adjustable size


For current products: all ECG/EEG
Packing unit: 4 pcs

H072 Veterinary Clip Electrode, 3 mm, cable length: 0.3 m, for K098
For current products: ECG-1950/9022
Packing unit: 5 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
18 Electrocardiographs > ECG Electrodes www.nihonkohden.net

Chest & Plate Electrodes


Supply Code Model Description
H041A 6144-000427 Chest Suction Electrode, 3 mm, adult, size: 20 mm dia, grey rubber ball
Packing unit: 3 pcs

H043A 6144-011852 Chest Suction Electrode, 4 mm, adult, size: 20 mm dia, grey rubber ball
Packing unit: 3 pcs

H044A NC-124D Chest Suction Electrode Tako, 4 mm, child, size: 14 mm dia, pink octopus
rubber ball
Packing unit: 3 pcs

H044B NC-124D Chest Suction Electrode Kuma, 4 mm, child, size: 14 mm dia, blue bear
rubber ball
Packing unit: 3 pcs

H049 Grey Rubber Ball Set for Adult Suction Electrode H043A
Packing unit: 3 pcs

H052A Pink Octopus Rubber Ball Set for Children Suction Electrode H044A
Packing unit: 3 pcs

H052B Blue Bear Rubber Ball Set for Children Suction Electrode H044B
Packing unit: 3 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
19 Electrocardiographs > ECG Electrodes www.nihonkohden.net

Supply Code Description


NKD-Z715 Plate Electrode, adult, size: 30 mm dia, suitable limb electrode straps, for NKD-Z722
Packing unit: 1 pcs

NKD-Z722 Rubber Strap, chest, size: 135 cm x 7 cm, black, 5 rows of holes, for plate electrode
NKD-Z715
Packing unit: 1 pcs

NKD-Z723 Attachment Button for Rubber Strap NKD-Z722


Packing unit: 1 pcs

Tab Electrodes
Supply Code Description
NKD-ECG/TAB1 ECG Tab Electrode Normal, Ag/AgCl, child/adult, radiolucent (X-ray, MRI),
size: 26 x 34 mm, bio-solid gel, backing material: graphite, for resting ECG
Packing unit: 500 pcs

NKD-ECG/TAB2 ECG Tab Electrode Small, Ag/AgCl, child, radiolucent (X-ray, MRI), size: 13 x 34 mm,
bio-solid gel, backing material: graphite, for resting ECG
Packing unit: 500 pcs

NKD-H/ADAPTER2 ECG Tab Electrode Clamps for NKD-ECG/TAB1 & NKD-ECG/TAB2, 4 mm banana plug
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
20 Electrocardiographs > ECG Electrodes www.nihonkohden.net

ECG Electrodes for Adults


NIHON KOHDEN VITRODE Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.

The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical
signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an extended period of time (over
48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause “noisy’’ ECG signals because of
the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting capabilities intermittently, and this leads
to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your annual volume! Use the possibility of call orders!

Supply Code Model Description


G203 L-150 ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape,
solid gel, general use
Packing unit: 5 x 30 pcs

G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony
softcloth with an elastic quality for tension, solid gel
Packing unit: 5 x 30 pcs

G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray),
foam tape, solid gel
Packing unit: 5 x 30 pcs

G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially
for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs

G236 M-150 ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape,
highbrid gel, for stress test
Packing unit: 5 x 30 pcs

G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel,
excellent adhesion even on sweaty skin
Packing unit: 5 x 30 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
21 Electrocardiographs > ECG Electrodes www.nihonkohden.net

ECG Electrodes for Children, Infants & Neonates


Supply Code Model Description
G210C F-150S ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm,
cotton tape especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs

ECG Electrode Adapter


Supply Code Description
N-00 Snap Adapter for Disposable ECG Electrodes, 4 mm dia plug to clip connector
Packing unit: 5 pcs

N-08 Clip Adapter for Disposable ECG Electrodes, 4 mm dia plug to snap connector
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Batteries
23 Electrocardiographs > ECG Batteries www.nihonkohden.net

ECG Batteries
Supply Code Model Description
X065 NKB-301V Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1350/2350/TEC-5500/7700
Packing unit: 1 pcs

X071 SB-901D Battery Pack, 12V, 1950 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1150/1250/1950
Packing unit: 1 pcs

X073 SB-150D Battery Pack, 12V, 3600 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-1500/1550
Packing unit: 1 pcs

X078 SB-201D Battery Pack, 14.4V, 3400 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: ECG-2550
Packing unit: 1 pcs

X040 LCS-2012NK Battery Pack, 12V, 2000 mAh, lead-acid, rechargeable


For old products: ECG-6000/OEC-8110
Packing unit: 1 pcs

X041A LCT-1912ANK Battery Pack, 12V, 1900 mAh, lead-acid, rechargeable


For old products: ECG-9022/9132
Packing unit: 1 pcs

X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeable


For old products: ECG-9320/TEC-7500
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Paper
25 Electrocardiographs > ECG Paper www.nihonkohden.net

ECG Paper
Supply Code Model Description
A052 FQW210-10-295 Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages,
with queue mark/perforation
For old products: ECG-9320
Packing unit: 10 pcs

A053 FQW210-30-295 Thermal Paper, Z-fold, 210 mm x 300 m (page 295 mm), 1017 pages,
without grid, with queue mark/perforation
For current products: ECG-2550/1550 | For old products: ECG-9320
Packing unit: 1 pcs

A128 RQS50-3 Thermal Paper, roll, 50 mm x 30 m, orange grid


For current products: TEC-8300
For old products: ECG-6651/TEC-7100/7200/7300
Packing unit: 10 pcs

A129 RQS63-3 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue


mark/perforation
For old products: ECG-1150
Packing unit: 10 pcs

NKD-210-10/295 Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages,
without grid, with queue mark/perforation, equivalent to
A052 & NKD-210-10A
For old products: ECG-9320/old MEB
Packing unit: 10 pcs

NKD-210-5-295 Thermal Paper, Z-fold, 210 mm x 50 m (page 295 mm), 169 pages,
without grid, equivalent to A053
For current products: ECG-2550/1550 | For old products: ECG-9320
Packing unit: 10 pcs

NKD-A054 Thermal Paper, Z-fold, 210 mm x 30 m (page 140 mm), 214 pages,
without grid, with queue mark/perforation
For current products: ECG-1350/2350 | For old products: ECG-9132
Packing unit: 10 pcs

NKD-A730 Thermal Paper, Z-fold, 110 mm x 20 m (page 140 mm), 143 pages,
without grid, with queue mark/perforation
For current products: ECG-1250/1950 | For old products: ECG-9022
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
26 Electrocardiographs > ECG Paper www.nihonkohden.net

Supply Code Description


NKD-63 Thermal Paper, Z-fold, 63 mm x 30 m (page 75 mm), 400 pages, with grid,
without queue mark/perforation
For old products: ECG-9620
Packing unit: 10 pcs

NKD-A129 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforation,


equivalent to A129
For current products: ECG-1150 | For old products: ECG-9620
Packing unit: 10 pcs

NKD-145-2,5 Thermal Paper, Z-fold, 145 mm x 25 m (page 100 mm), 85 pages, orange grid,
equivalent to A036B
For old products: ECG-8400
Packing unit: 10 pcs

NKD-145-6A300 Thermal Paper, roll, 145 mm x 60 m (page 300 mm), 200 pages, orange grid,
equivalent to A132 but without queue mark/perforation
For old products: ECG-8821
Packing unit: 10 pcs

NKD-A134A Thermal Paper, roll, 210 mm x 30 m, without grid/queue mark/perforation


For old products: ECG-9110/9130/9132
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Additional ECG Accessories
28 Electrocardiographs > Additional ECG Accessories www.nihonkohden.net

Additional ECG Accessories


Supply Code Model Description
F010 Z-101BC “CardioCream” ECG Electrode Paste, 100 g tube
Packing unit: 2 pcs

NKD-G711 Electrode Spray Gyrolux, skin preparation for use of suction vacuum pumps,
250 ml bottle
Packing unit: 1 pcs

NKD-SD1GB Memory SD Card 1 GB


Packing unit: 1 pcs

Y011 404617 Thermal Head Cleaner Pen


For current products: all ECG/TEC/old MEB/EEG/allBSM/PVM/OPV/WEP
Packing unit: 1 pcs

NKD-BAG Carrying Bag for ECG & Accessories


For current products: ECG-1150/1250/1350/1950/2350
Packing unit: 1 pcs

NKD-L936 Power Cable, Schuko plug, cable length: 2.0 m


Packing unit: 1 pcs

NKD-POWERLINE Multiple Power Socket (4 slots), medical certification


Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
29 Electrocardiographs > Additional ECG Accessories www.nihonkohden.net

Supply Code Description


K117A Connection Cable for Input Box, cable length: 2.0 m
For current products: ECG-2550
Packing unit: 1 pcs

K117B Connection Cable for Input Box, cable length: 5.0 m


For current products: ECG-2550
Packing unit: 1 pcs

K117C Connection Cable for Input Box, cable length: 10.0 m


For current products: ECG-2550
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Accessories for Defibrillators
Defibrillator Batteries & Battery Charger
32 Defibrillators > Defibrillator Batteries & Battery Charger www.nihonkohden.net

Defibrillator Batteries & Battery Charger


Supply Code Model Description
X065 NKB-301V Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: TEC-5500/7700/ECG-1350
Packing unit: 1 pcs

X077 SB-831V Battery Pack, 14.4V, 6300 mAh, lithium-ion battery, rechargeable
For current products: TEC-8300
Packing unit: 1 pcs

X041 LCT-1912NK-1 Battery Pack, 12V, 1900 mAh, lead-acid, rechargeable


For old products: TEC-7100/7200
Packing unit: 1 pcs

X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeable


For old products: ECG-9320/TEC-7500
Packing unit: 1 pcs

X060A NKB-102V Battery Pack, 12V, 1700 mAh, nickel-cadmium (NiCd), rechargeable
For old products: TEC-8200
Packing unit: 1 pcs

SB-801V External Dual Battery Charger, for 2x battery X077


For current products: TEC-8300
Packing unit: 1 pcs

SC-831V AC/DC Module for Series TEC-8300K


For current products: TEC-8300
Packing unit: 1 pcs

SB-551V External Dual Battery Charger, for 2x battery X065


For current products: TEC-5500/7700
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Defibrillator Paper
34 Defibrillators > Defibrillator Paper www.nihonkohden.net

Defibrillator Paper
Supply Code Model Description
A128 RQS50-3 Thermal Paper, roll, 50 mm x 30 m, orange grid
For current products: TEC-8300 | For old products: ECG-6651/TEC-7100/7200/7300
Packing unit: 10 pcs

A222 FQS50-3-100 Thermal Paper, Z-fold, 50 mm x 30 m (page 100 mm), 300 pages, orange grid
For current products: TEC-7700
Packing unit: 10 pcs

A226 FQS50-2-100 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange grid
For current products: TEC-5500/BSM-2300/3000
Packing unit: 10 pcs

A238 PS50-2 Thermal Paper, roll, 50 mm x 20 m, orange grid, without queue mark/perforation
For old products: TEC-6600
Packing unit: 10 pcs

NKD-A226 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange grid
For current products: TEC-5500
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Defibrillator Bags
36 Defibrillators > Defibrillator Bags www.nihonkohden.net

Defibrillator Bags
Supply Code Description
NKD-DEFIBAG83 Softbag for Series TEC-8300K incl. Warning Sign Label
Please indicate the specified abbreviation letter for the required language when
ordering: English (K), German (G), French (F), Italian (R), Spanish (E), Turkish (TR)
or Russian (RU)!
For current products: TEC-8300
Packing unit: 1 pcs

NKD-STRAP83 Shoulder Strap for Series TEC-8300K Softbag


For current products: TEC-8300
Packing unit: 1 pcs

NKD-DEFIBAG2 Carrying Bag 2 with 2 Additional Attached Accessory Bags


For current products: TEC-7700
Packing unit: 1 pcs

NKD-DEFIBAG3 Carrying Bag 3 with 1 Additional Attached Accessory Bag


For current products: TEC-5500
Packing unit: 1 pcs

NKD-DEFIBAG6 Accessory Bag


For current products: TEC-5500/7700
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Disposable Defibrillator Pads

Disposable Pads with


NIHON KOHDEN Connector

Disposable Pads with


R2 Connector
38 Defibrillators > Disposable Defibrillator Pads www.nihonkohden.net

Disposable Pads with NIHON KOHDEN Connector


Supply Code Model Description
H312 P-513 Defibrillation Pads with Outside Connector, infant (< 10 kg), for use with adapter
cable JC-765V/K342B, weight: 80 g ± 10 g, size: 73 mm ± 8 mm x 110 mm ± 11 mm,
conductive surface: 48.40 cm2 ± 10%, cable length: 1.5 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair

H327 P-511 Defibrillation Pads with Outside Connector, child/adult (> 10 kg), for use with
adapter cable JC-765V/K342B, weight: 90 g ± 15 g, size: 108 mm ± 10 mm x 159 mm ±
10 mm, conductive surface: 99 cm2 ± 10%, cable length: 1.5 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair

K342B JC-865V Adapter Cable for Disposable Defibrillator Pads H312/H327/H324A,


cable length: 3.5 m
For current products: TEC-8300
Packing unit: 1 pcs

JC-765V Adapter Cable for Disposable Pads H312/H327/H324A, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

Y206A AX-250V AED Cable Testing Unit for NIHON KOHDEN-Pads with
Adapter Cable JC-765V/K342B
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
39 Defibrillators > Disposable Defibrillator Pads www.nihonkohden.net

Disposable Pads with R2 Connector


Supply Code Model Description
NKD-H405 Defibrillator Pads with Outside R2 Connector, adult, for use with adapter cable
JC-755V/K342A, size: 159.93 cm², conductive surface: 114.75 cm²,
cable length: 1.28 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair

NKD-H406 Defibrillator Pads with Outside R2 Connector, child, for use with adapter cable
JC-755V/K342A, size: 78.13 cm², conductive surface: 53.80 cm², cable length: 1.28 m
For current products: TEC-5500/7700/8300
Packing unit: 1 pair

K342A JC-855V Adapter Cable for Disposable Defibrillator Pads NKD-H405/NKD-H406


with R2 Connector, cable length: 3.5 m
For current products: TEC-8300
Packing unit: 1 pcs

JC-755V Adapter Cable for Disposable Defibrillator Pads NKD-H405/NKD-H406


with R2 Connector, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

Y206B AX-251V AED Cable Testing Unit for R2 Pads with Adapter Cable JC-755V/K342A
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Paddle Electrodes

Internal Paddle Electrode

Neonate Paddle Adapter


41 Defibrillators > Paddle Electrodes www.nihonkohden.net

Internal Paddle Electrode with Discharge Button


for Series TEC-8300
Supply Code Description
ND-893V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 35 mm dia
For current products: TEC-8300
Packing unit: 1 pair

ND-894V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 45 mm dia
For current products: TEC-8300
Packing unit: 1 pair

ND-895V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 55 mm dia
For current products: TEC-8300
Packing unit: 1 pair

ND-896V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 65 mm dia
For current products: TEC-8300
Packing unit: 1 pair

ND-897V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 75 mm dia
For current products: TEC-8300
Packing unit: 1 pair

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
42 Defibrillators > Disposable Defibrillator Pads www.nihonkohden.net

Internal Paddle Electrode with Discharge Button


for TEC-5500/7700
Supply Code Description
ND-593V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 35 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

ND-594V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 45 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

ND-595V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 55 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

ND-596V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 65 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

ND-597V Internal Paddle Electrode with Discharge Button, including handle & electrode,
size: 75 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

Neonate Paddle Adapter for TEC-5500/7700


Supply Code Description
ND-612V Paddle Adapter, neonate, size: 44 mm dia
For current products: TEC-5500/7700
Packing unit: 1 pair

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.

Some functions are limited on series TEC-8300K. Contact your NIHON KOHDEN repre-
sentative for details.

Number of false alarms


3000

2500 V. Rhythm

Tachy
2000
VPC Run
1500
VT

1000 Ext. Tachy

VF
500

0
Without ec1 With ec1
44 Cardiology › Typical Arrhythmia Waveforms www.nihonkohden.net

Typical Arrhythmia Waveforms


Premature Supraventricular Contractions
(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)

P P

• Narrow QRS (excluding aberrant ventriular conduction) • Slight ripples on the baseline • Irregular R-R intervals
• Ectopic focus higher than His-bundle • Non-compensatory pause • Inverted QRS complexes • Non-compensatory pause

Premature Ventricular Contractions (PVC) Ventricular Tachycardia (VT)

• Premature contractions • Bizarre and wide QRS complexes • Fast pulse rate greater than 100 bpm • 3 or more irregular beats
• Full compensatory pause • Frequent PVCs are serious • Needs emergency treatment and countershock • May progress to

Multi- focal PVC Ventricular Fibrillation (VF)

2
1
• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes
• Needs emergency treatment and countershock

Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II

P P P

• Consecutive PVCs • May progress to ventricular tachycardia • Sudden absence of QRS complexes (P-waves observed) • May progress
to cardiac arrest • Possibillity of Adams-Stokes syndrome
• Occasionally needs pacing

R-on-T PVC Third-degree (complete) atrioventricular (AV) block

P P P P P P P P P P P

• PVC on summit of T-wave • Bizarre and wide QRS complexes • Independent development of P-waves and QRS complexes • Possibility
of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing

Nihon Kohden products


which detect arrhythmia

Electrocardiographs / Defillibrators / Bedside Monitors

Diagnostic ECG Electrode Placement Heart Anatomy Cardiac Conduction Sytem


R and L electrodes should be placed just below 1. Inferior vena cava Atria His bundle 1 The sinoatrial (SA) node generates
the right and left clavicle. N and F electrodes should 2. Superior vena cava SA node a wave of electrical excitation.
15 16 17 3. Right atrium
1 2
Left 2 The excitation travels through
be placed on the lower edge of the rib cage, or at 2 bundle the internodal pathways to the
2 4. Tricuspid valve 3
branch
the level of the umbilicus at the mid-clavicular line. AV node atria and the atrial muscles contract.
7 7
5. Right ventricle Purkinje This is recorded as the P-wave.
8 14 6. Pulmonary valve Right
4
fibers 3 The excitation travels to the
Lead Electrode Placement 7. Pulmonary artery bundle 5

9 8. Pulmonary vein branch atrioventricular (AV) node.


C1 Fourth intercostal space at the 5

right border of the sternum 13 8 9. Left atrium 4 The excitation then travels through
10 Purkinje Ventricles the bundle of His and down through
3 7 10. Mitral valve fibers
C2 Fourth intercostal space at the R L 12 the right and left bundle branches.
right border of the sternum 6 11 11. Left ventricle R 5 The excitation terminates at the
12. Aortic valve
C3 Midway between locations C2 Purkinje fibers in the ventricles and
and C4 C1 C2 1 4 5
13. Coronary artery P T
the ventricular muscles contract. This
C3 C6 14. Aorta is the depolarization and is recorded
-------------
-------------

C4 At the mid-clavicular line in the


-------------------

-------------------

C5
--------------------------

C4 15. Brachiocephalic artery


--------------------------

Q S 1 as the QRS complex.


fifth intercostal space
Disposable accessories are intended for single use only, on one patient, during 18 a single examination!
16. LeftDo not re-use
common carotiddisposable
artery accessories! 2 6 The ventricular muscles relax. This is
C5 At the anterior axillary line on the 17. examinations.
Left subclavian artery 3.4 the repolarization and is recorded as
sameReusable
horizontalaccessories
level as C4 are intended Nfor repeated patient
F use on different patients during different
18. Descending aorta
Please make sure to clean reusable accessories 5 after each patient or
the T- wave.
C6
between different applications to prevent or reduce the risk of cross infections! 6
At the mid-axillary line on the
same horizontal level as C4 and C5
ECG Cables
ECG Cables for TEC-8300

ECG 3/6-Lead Cables

ECG 10-Lead Cables


47 Defibrillators > ECG Measurement www.nihonkohden.net

ECG 3/6-Lead Cables


6-lead ECG measurement
V4 V5
Powerful ECG measurement
ST Change Detection Report • II + V5 lead symbol 80%
96 % of an ischaemia change can be • Only with I lead symbol 33% • II + V5 + V4 lead symbol 96%
detected by 6 electrodes (II, V4, V5) • Only with V5 lead symbol 75% More accurate ischaemia detection

Supply Code Model Description


6124-039432 Connection Cable Cover for DIN Type Electrodes for K922
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs

K120 NA-0003 Electrode Lead Tube for K911/K910A


For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs

K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs

K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-8300/5500/7700/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs

K913A BR-906V 6-Lead ECG Electrode Cable, clip, cable length: 0.6 m
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs

K912 BR-906P 6-Lead ECG Electrode Cable, clip, cable length: 0.8m requires K922
For current products: TEC-8300/all BSM/PVM; ZM-920/930/940PG
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
48 Defibrillators > ECG Measurement www.nihonkohden.net

Supply Code Model Description


K915 BR-916P 6-Lead ECG Electrode Cable, snap, cable length: 0.8m,requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs

K922 JC-906P 3/6-Lead ECG Connection Cable for K910A/K911/K912/K915 to patient


monitors/defibrillator, cable length: 3.0 m
For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;
ZM-920/930/940PG
Packing unit: 1 pcs

ECG 10-Lead Cables


Supply Code Model Description
K901 BJ-900P 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 3.8 m, incl. patient
electrode lead & connection cable
For current products: BSM-1700/3000/5100/6000/9100/TEC-8300
Packing unit: 1 pcs

K354 BJ-831V 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 2.5 m
For current products: TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Cables for TEC-5500 & TEC-7700

ECG 3-Lead Cables

ECG 5-Lead Cables

Additional Defibrillator
Connection Cables
50 Defibrillators > ECG Measurement www.nihonkohden.net

ECG 3-Lead Cables


Supply Code Model Description
K120 NA-0003 Electrode Lead Tube, for K911/K910A
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs

K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-5500/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs

K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-5500/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-5500/7700/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs

K225 BR-018P 3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs

K226 BR-019P 3-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs

K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode Lead
K225/K226/K227/K228
For current products: TEC-5500/7700
Packing unit: 1 pcs

K352A BC-763VA 3-Lead ECG Connection Cable (AHA), snap, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

K353A BC-763V 3-Lead ECG Connection Cable (IEC), snap, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
51 Defibrillators > ECG Measurement www.nihonkohden.net

ECG 5-Lead Cables


Supply Code Model Description
K227 BR-020P 5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs

K228 BR-021P 5-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152
For current products: TEC-5500/7700
Packing unit: 1 pcs

K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode Lead
K225/K226/K227/K228
For old products: TEC-8250/8251
Packing unit: 1 pcs

K352B BC-765VA 5-Lead ECG Connection Cable (AHA), clip, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

K353B BC-765V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
52 Defibrillators > ECG Measurement www.nihonkohden.net

Further Defibrillator Connection Cables


Supply Code Model Description
K232 BR-002P 3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m
For old products: TEC-7000
Packing unit: 1 pcs

K350A BC-753V 3-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For old products: TEC-7500
Packing unit: 1 pcs

K234 BR-004P 5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m
For old products: TEC-7000
Packing unit: 1 pcs

K332 JC-002P Connection Cable (IEC) for ECG Electrode Lead K234, cable length: 3.0m
For old products: TEC-7000
Packing unit: 1 pcs

K351A BC-755V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 m
For old products: TEC-7500
Packing unit: 1 pcs

L151 JC-761V External ECG Input Cable, connection to patient monitors, cable length: 2.9 m
For current products: TEC-5500/7700
Packing unit: 1 pcs

L152 JC-762V External Defibrillator Connection Cable, cable length: 3.0 m,


for ECG Electrode Lead K225/K226/K227/K228
For current products: TEC-5500/7700
Packing unit: 1 pcs

L153 JC-763V External Defibrillator Connection Cable, cable length: 3.0 m,


for ECG Electrode Lead K910A/K911
For current products: TEC-5500/7700
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ECG Electrodes for Defibrillators

NIHON KOHDEN Vitrode Disposable ECG Electrodes –


The result of over 30 years experience in disposable electrode manufacturing.

The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that
the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an exten-
ded period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause
“noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting
capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is
to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your annual volume! Use the possibility of call orders!

Standard Electrodes Placements


It is important to prepare the skin before attaching
the electrodes by cleaning it and removing chest
hair. After this please attach the lead wire to the
electrodes before placing them on the skin. This
avoids pain to the patient. Secure the lead wire to
the skin (stress loop) preventing moving of the
Three electrodes Six electrodes Ten electrodes
lead wire and therefore noise on the ECG signal.

ECG Electrodes for Adults

ECG Electrodes for Children,


Infants & Neonates
54 Defibrillators > ECG Measurement www.nihonkohden.net

ECG Electrodes for Adults


Supply Code Model Description
G203 L-150 ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape,
solid gel, general use
Packing unit: 5 x 30 pcs

G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony soft-
cloth with an elastic quality for tension, solid gel
Packing unit: 5 x 30 pcs

G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam
tape, solid gel
Packing unit: 5 x 30 pcs

G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape
especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs

G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel,
excellent adhesion even on sweaty skin
Packing unit: 5 x 30 pcs

G272A V-09OM3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,


cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 30 x 3 pcs

G272B V-040M4 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,


cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
4 pre-wired electrodes with 1.5 mm touch proof connector for limb leads
Packing unit: 10 x 4 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
55 Defibrillators > ECG Measurement www.nihonkohden.net

Supply Code Model Description


G272C V-06OM6 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,
cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape,
6 pre-wired electrodes with 1.5 mm touch proof connector for chest leads
Packing unit: 10 x 6 pcs

G278A V-09IO3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm,


cable length: 1.5 m, radiolucent (X-ray), foam tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 30 x 3 pcs

ECG Electrodes for Children, Infants & Neonates


Supply Code Model Description
G210C F-150S ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm,
cotton tape especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs

G271A V-120S3 ECG Electrode Vitrode V, Ag/AgCl, neonate/infant, without motif print,
size: 20 mm dia, cable length: 0.6 m, radiolucent (X-ray), foam & cotton tape,
3 pre-wired electrodes with 1.5 mm touch proof connector
Packing unit: 40 x 3 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
SpO₂ Measurement
A Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation
in the blood by use of a clip-on finger probe. Pulse oximeter works with the integration of a
probe placed onto patient’s fingertip or toe, obtains signals from the probe and the main
device calculates oxygen saturation in the body.

Oxygen saturation measured by a Pulse Oximeter is SpO2. “P” stands for “pulse”, and the
measurement principle is based on beat-by-beat changes in blood volume. In general, arteri-
al oxygen saturation measured by spectroscopic analysis is called “SaO2”, and oxygen satura-
tion measured by pulse oximeter is called “SpO2”.

The method for determination of arterial oxygen saturation, based on the photoelectric ple-
thysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer
Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear den-
sitometer for recording dilution curves for dyes (pigments). The first commercial oximeter
“OLV-5100” was presented by NIHON KOHDEN back in 1975.

Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In
2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.
The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.

Disposable
SpO2 Cables
58 Defibrillators > SpO2 Measurement www.nihonkohden.net

SpO2 Cables
Supply Code Model Description
K931 JL-900P SpO2 Connection Cable, cable length: 2.5 m, rectangular connector
For current products: TEC-8300/all BSM/PVM/PSG-1100
Packing unit: 1 pcs

Y095A JL-550T2 SpO2 Connection Cable, cable length: 2.5 m, round connector
For current products: TEC-5500/7700/JE-912A/921A/921AG
Packing unit: 1 pcs

Note
SpO2 measurement starts when the SpO2 connection cable and SpO2 probe are connected to the device, and the SpO2 probe
is attached to the patient.

When not measuring SpO2, disconnect the SpO2 connection cable from the device. Otherwise, noise from the probe sensor
may interfere and incorrect data is displayed on the screen.

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
SpO₂ Probes

BluPRO® SpO₂ Probes – A Unique Sensing Technology


Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient
comfort. The comfortable, sure fitting and lightweight characteristic reduces the effect of hand movement for
highly reliable SpO2 measurement.

This ensures patient safety, reduces the costs of care and increases therefore clinical efficiency and cost
effectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.

Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manu-
factured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN
probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on
NIHON KOHDEN devices. NIHON KOHDEN is not responsible for problems caused by using other manufacturer’s probes.

Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!

Reusable SpO2 Probes

Disposable SpO2 Probes


60 Defibrillators > SpO₂ Measurement www.nihonkohden.net

SpO₂ Probes
Su
p
ply

Low birth Neonate Infant Child Adult


Ca
b

Pa
Co

le

weight
ck
d

len
e(

in
gt

gu
M

h(
od

nit
m)
el)

1000 g 2 kg 3 kg 10 kg 20 kg 30 kg 40 kg 50 kg

P203A (TL-271T) 0.8


24
P203E (TL-271T3) 1.6
P204A (TL-271T) 0.8
5
P204E (TL-271T3) 1.6

P203B (TL-272T) 0.8


24
P203F (TL-272T3) 1.6
P204B (TL-272T) 0.8
5
P204F (TL-272T3) 1.6

P203C (TL-273T) 0.8


Disposable

24
P203G (TL-273T3) 1.6
P204C (TL-273T) 0.8
5
P204G (TL-273T3) 1.6

P203D (TL-274T) 0.8


24
P203H (TL-274T3) 1.6
P204D (TL-274T) 0.8
5
P204H (TL-274T3) 1.6

P228A (TL-051S) 0.8


5
P228B (TL-052S) 1.6

P229A (TL-061S) 0.8


5
P229B (TL-062S) 1.6

P225F (TL-201T) 1.6


P225H (TL-201T1) 0.6
Reusable

P225G (TL-220T) 1.6


1

P311C (TL-631T3) 1.6


P310C (TL-630T3) 1.6
61 Defibrillators > SpO2 Measurement www.nihonkohden.net

Reusable SpO2 Probes


Reusable, but always clean – NIHON KOHDEN washable probes.

The reusable probes of the BluPRO® series are durable and washable,
so you can clean them under running water or even immerse them in a
soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 %
or hydrochloric alkyl diaminoethylene glycine 0.5 %)! P225F / P225H P225G P310C / P311C
Durable, washable, demand-oriented!

Facts
NIHON KOHDEN reusable SpO2 finger-clips probes have parallel mounted upper and lower sensor shells, thus, providing an exact alignment of the op-
tical sensor components and markedly enhanced comfort during long-term attachment. In addition, flexible lateral flaps shield the measuring signals
from the external light, thus resulting to minimize the interference by additional artificial light sources! Bright LEDs provide more accurate measure-
ment even for thicker fingers or dark skin tones. The finger-clip reusable probe is the most popular type of SpO2 probes. Instead of the typical hinge near
the finger tip, P225F/P225H have a unique sure fitting and comfortable mechanism using two sliding pieces for the front and back of the finger with
two rubber flaps along both sides of the finger. When you press the button, the two halves of the probe slide directly open, parallel to each other. No
additional fixation tape is needed. For a stable and comfortable measurement P225F/P225H, always keep the light emitters and detector aligned. NIHON
KOHDEN provides unique reusable SpO2 probes.

Supply Code Model Description


P225F TL-201T SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger,
cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs

P225H TL-201T1 SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger,
cable length: 0.6 m, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs

Facts
The multi-site probe P225G can be used for neonatal feet as well as adult fingers as its curved contact surface is designed to fit on different attachment
sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding
adjuster gives the best fit on the attachment site secured by taping.

Supply Code Model Description


P225G TL-220T SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep,
child/adult ( > 3 kg) finger/toe, cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
62 Defibrillators > SpO2 Measurement www.nihonkohden.net

Facts
Our special designed finger-tip probes, P310C and P311C, fit immediately on the finger and are perfect for long-term measurement. A less covered finger
area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fit.
In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one
attachment site. A stable measurement is assured by gentle fixation tapes P263 or P267 that avoid the falling off of the probes and reduce artifact from
cable movement.
Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their
fingers or obese patients.

Supply Code Model Description


P310C TL-630T3 SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs

P311C TL-631T3 SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 1 pcs

P263 Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mm
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 3 x 30 pcs

P267 YS-093P2 Disposable Probe Fastener Tape for P310C/P311C,


size: 15 x 140 mm
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 30 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
63 Defibrillators > SpO2 Measurement www.nihonkohden.net

Disposable SpO2 Probes


NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and
detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment
with each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site.
Paediatric probes have a cute cartoon character printed on the tape to reassure children.

Self-adhesive, soft and thin tape provides a secure fit. The special design allows an easy application to the attachment site. To get
the most comfortable fit, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and
do not push the tip of the finger with the attachment tape.

Disposable SpO2 Probes 24 pcs/box – cable length: 0.8 m

Supply Code Model Description


P203A TL-271T SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203C TL-273T SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203D TL-274T SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
64 Defibrillators > SpO2 Measurement www.nihonkohden.net

Disposable SpO2 Probes 24 pcs/box – cable length: 1.6 m


Supply Code Model Description
P203E TL-271T3 SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203F TL-272T3 SpO2 BluPRO® Probe, child ( 10 – 50 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

P203H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products:all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 24 pcs

Disposable SpO2 Probes 5 pcs/box – cable length: 0.8 m

Supply Code Model Description


P204A TL-271T SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

P204B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
65 Defibrillators > SpO2 Measurement www.nihonkohden.net

Supply Code Model Description


P204C TL-273T SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

P204D TL-274T SpO2 BluPRO® Probe, infant ( 3 –20 kg) finger/toe, cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!
The light emitter and detector are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation.
Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around
the finger with attachment tape P259.

Supply Code Model Description


P228A TL-051S SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs

P229A TL-061S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 0.8 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs

P259 COTTONY Tape for fixing disposable SpO2 Probes


For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 20 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
66 Defibrillators > SpO2 Measurement www.nihonkohden.net

Disposable SpO2 Probes 5 pcs/box – cable length: 1.6 m

Supply Code Model Description


P204E TL-271T3 SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

P204F TL-272T3 SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

P204G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

P204H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 5 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
67 Defibrillators > SpO2 Measurement www.nihonkohden.net

Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced! The light emitter and detector
are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation. Since the probe itself is not
self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around the finger with attachment
tape P259.

Supply Code Model Description


P228B TL-052S SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs

P229B TL-062S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs

P259 COTTONY Tape for fixing disposable SpO2 Probes, disposable


For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG;
ZM-930/940PG
Packing unit: 20 pcs

Handling of the probe affects measurement accuracy and patient safety


For the proper placement of the probe on the finger, it is advisable that the light emitter and detector are placed just opposite to each
other. When using a finger clip probe, it is necessary to ensure that the probe covers the finger properly, otherwise some portion of the light
never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.

The more distant the light emitter and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part
tends to have small amount of blood, which makes it difficult to extract the arterial blood signal component. The most suitable thickness
of the probe site is about 10 mm.

Too loose probes may interfere with alignment of LEDs and detector, come off easily by body movement, cause larger motion artifacts or
be effected by venous pulse.

Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower
pulsatile signal.

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
ETCO2 Measurement (Capnography)
Reasons to measure ETCO₂ (the level of carbon dioxide in the air exhaled from the body –
normal value is about 38 mm Hg): Capnography helps to detect life-threatening problems in:
• Airway
• Breathing
• Circulation and
• Metabolism

Capnography is a fast and reliable help to determinate respiratory difficulties, wrong connections of airway
adapters, leaks in the ventilator circuit due to its placement in the respiratory circuit. An early detection by
capnography might help to avoid inadequate oxygen supply of the body.
69 Defibrillators > ETCO2 Measurement www.nihonkohden.net

ETCO2 Measurement (Capnography)


The necessity of monitoring ETCO2 is recognized
by various health care associations guidelines: Capnometer Mainstream Method
Canadian Anesthesia Society (CAS) In a mainstream system, the
Guidelines for Sedation – January, 2012 sensor is located directly in

Anesthesia Patient Safety Foundation (APSF) the patient’s breathing circuit.


Monitoring with Use of Post-op Opioids – August, 2011 Real time measurement values.

American Society for Anesthesiologists (ASA)


Standards for Basic Anesthetic Monitoring – July, 2011 CO2 Sensor
Association of Anaesthetists of Great Britain & Ireland (AAGBI)
The use of capnography outside the operating theatre – May, 2011

American Association of Respiratory Care (AARC)


Capnometer
CPG for Capnography/Capnometry During Mechanical Sidestream Method
Ventilation – April, 2011 CO2 Sensor In a sidestream system, a gas
British Royal College of Anesthetists sample is removed from the
Airway Recommendation (NAP4) – March, 2011 patient’s airway and delivered

European Resuscitation Council (ERC) to a distant sensor.


Guidelines for Resuscitation – November, 2010 Measurement values delayed.
Suck in
American Heart Association (AHA) Not possible with
Sampling tube
Resuscitation Guideline – November, 2010 NIHON KOHDEN defibrillators.

ETCO2 Selection Guide


Start
Yes No
Is CO2 the only gas to measure? Multi-gas measurement
No Please use NIHON KOHDEN
Is the patient a neonate? patient monitors!

Yes

No measurement possible Mainstream measurement

Yes No
Is the patient intubated?

Emergency

No
CO2 sensor kit
Is a humidifier or nebulizer used? No
P907 (TG-920P) & P908 (TG-921T3)

Yes Both intubated & non-intubated

With nebulizer
CO2 sensor kit P909 (TG-970P) Intubated Non-intubated
R805 (YG-211T) Airway adapter adult (> 7 kg) R804 (YG-111T) Airway V921 (YG-120T) Nasal adapter (> 10 kg)
adapter (> 7 kg)
V922 (YG-121T) Nasal/Oral adapter (>10 kg)
V923 (YG-122T) Nasal/Oral adapter with O₂
CO2 sensor kit P903 (TG-900P) supply tube adapter (> 10 kg)
R801 (YG-101T) Airway adapter adult, (> 10 kg) NKD-02-Cap Oxygen cannula

CO2 sensor kit P909 (TG-970P)


R805 (YG-211T) Airway adapter adult (> 7 kg)
ETCO2 Measurement Overview
The best way to observe the patient‘s respitatory condition

ETCO2 shows clinical and technical problems


mmHg Normal capnograph and ETCO2 waveform
Hypoventilation
Increasing CO
Malignant high fever
Pain of light anesthesia ETCO2
45
Normal range

35 Hyperventilation
Decreasing CO
Pulmonary embolism
Deep anesthesia
PaCO2 level Normal range: steep rising and flat expiratory phase Hyperventilation Hypoventilation

Breathing circuit abnormality Respiratory abnormality Trend


· Breathing circuit abnormality · Obstructive defect, bronchial spasm ETCO2=PaCO2 · Downward · Upward
40 40
40
40

Sudden decrease of CO2 Gentle expiratory phase

· Ventilation disconnection · Rebreathing 40 40

40 40

Hyperventilation
Hypoventilation
Sudden decrease of CO2 toward zero Gentle expiratory phase Decreasing CO
Temperature increase
Pulmonary embolism
· Esophageal intubation · Spontaneous breathing Malignant high fever
Temperature decrease
40 40 Partial obstruction of
Disconnection in
breathing circuit breathing circuit
Asphyxia
Ventilator stop Sudden disappearance of
Zero CO2 or very low CO2 Cumulative irregular respiratory waveform
CO2 waveform

5 phases of the capnograph Conditions reflected by ETCO2

Blood Breathing
circulation Airway Connector Ventilator

Beginning of Start exhalation Plateau of CO2 in End of Inhalation CO2 Respiratory Circuit
monitor
exhalation of CO2 in alveoli alveoli of the lung exhalation phase
of the lung
Metabolism Gas exchange
Pulmonary circulation CO2 absorber Fresh gas

Early detection of trouble in breathing or ventilation equipment

Inadequate Indequate ETCO2 and PaCO2 show ventilation and pulmonary blood flow condition
ventilation Kink Disconnection gas flow

Normal ventilation Abnormal ventilation and Normal ventilation and


normal pulmonary blood flow abnormal pulmonary
blood flow
Malfunction 40 mmHg 40 mmHg 20 mmHg
( ETCO2) ( ETCO2) ( ETCO2)
46 mmHg 46 mmHg 46 mmHg 46 mmHg 46 mmHg 46 mmHg
40 40 40 40 0
40 40 46 40 40
Leak
40 mmHg ( PaCO2) 43 mmHg ( PaCO2) 40 mmHg ( PaCO2)
Esophageal intubation
Apnea Obstruction

CO2 Measurement is useful in many hospital sites Nihon Kohden Unique Sensing Technology

ER Neonate OR ICU PSG With ventilator or Sedation Both intubated and non-intubated cap-ONE CO2 Sensor
nebulizer
ETCO2 Mainstream

Application Fields of Airway Adapters for Application Fields of Nasal Adapters for
Intubated Patients Non-Intubated Patients

Emergency / Pre-hospital Care Transport / Pre-hospital Care


• Detection of endotracheal tube • Detection of changes in respiratory status
displacement (over- or underventilation of trauma / shock
victims; COPD patients)
• Control of CPR efficacy
• Detection of respiratory depression of
• ROSC detection
sedated patients or anaesthesia without
(Return of Spontaneous Circulation)
intubation
• Oxygenation management
• Spot-checking of ETCO2 level & respiration
• Airway circuit management rate of critically ill non-intubated patients
• Keeping ICP appropriate by checking ETCO2 level • Detection of effectiveness of treatment
(i.e. patients with craniocerebral injury – CCI)
• Detection of respiratory distress
(occlusion, connection leak, accidental
extubation, ventilator trouble etc.)
• Detection of poor pulmonary perfusion
• Apnea monitor
• Detection of effectiveness of treatment
72 Defibrillators > ETCO2 Measurement www.nihonkohden.net

Intubated Expired ETCO2


Supply Code Model Description
P906 TG-901T3 CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement,
incl. CO2 sensor and CO2 adapter, expiratory CO2, cable length: 3.0 m
For Airway Adapters: R801
For current products: TEC-5500/7700
Packing unit: 1 pcs

P903 TG-900P CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement,
incl. P922A/K981, expiratory CO2, cable length: 3.0 m
For Airway Adapters: R801
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs

P922A TG-101T CO2 Sensor for Expiratory CO2 for Intubated Patients, part of CO2 Sensor Kit P903,
cable length: 1.0 m, requires Adapter Cable: K981
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs

K981 JG-900P CO2 Adapter Cable for P922A/P903, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs

R801 YG-101T Airway Adapter for P903/P906/P922A, intubated, semi-quantitative method,


child/adult (>10 kg), dead space: 5 ml
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 50 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
73 Defibrillators > ETCO2 Measurement (Capnography) www.nihonkohden.net

Intubated Expired and Inspired ETCO2


“Opening a New Era in Capnography“
Facts
NIHON KOHDEN CO2 Sensor Sensation - P909 World‘s smallest and lightest mainstream ETCO2 sensor (quantitative method) with only 4 g (±2 g).
This avoids tube pressures and increases patient comfort. Especially for this reason as well as the dead space of approximately 1 ml it is perfectly suited to
the most sensible intubated patients – neonates in critical care (application on neonates only with patient monitors). Besides this P909 can be also applied
to children and adults. Easy and simple handling is guaranteed by its waterproofness (IPX7 standard) and our Smart CableTM Technology so that no additional
module is needed. Just plug in and start a continuous measurement after only 10 seconds warm-up time. Those features make the P909 an unbeatable help for
daily work routine in OR, ER, ICU or Ward.

Supply Code Model Description


P909 TG-970P cap-ONE CO2 Sensor Kit for Intubated Patients,
quantitative measurement, incl. P924/K987,
size: 8 x 13 x 35 mm, cable length: 3.5 m
For Airway Adapters: R805
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

P924 TG-221T cap-ONE CO2 Sensor for Intubated Patiens, part of CO2 Sensor Kit P909,
cable length: 3.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

K987 JG-970P cap-ONE CO2 Adapter Cable for P909/P924, cable length: 0.5 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

R805 YG-211T Airway Adapter for P909, intubated, quantitative method, adult (> 7 kg),
dead space: 4 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 30 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
74 Defibrillators > ETCO2 Measurement (Capnography) www.nihonkohden.net

Intubated and Non-Intubated Expired ETCO2


“Opening a New Era in Capnography“
Facts
NIHON KOHDEN cap-ONE–when every breath counts!
World’s first wearable mainstream ETCO2 sensor P907 (semi-quantitative method) for intubated and non-intubated patients which is applicable for
children and adults.
Unique oral-nasal airway adapters catch oral as well as nasal expired CO2 – this increases accuracy. The cap-ONE is not only small but has also a
mini-weight of only 4 g. This avoids tube pressures and increases patient comfort. Easy and simple handling is guaranteed by our Smart CableTM Technology so
that no additional module is needed, just plug in and start measuring after only 5 seconds. A continuous, stable and accurate measurement is ensured
due to no lag time and no need to change tubes because of occlusions. Its waterproofness and outstanding shock resistance are an unbeatable advan-
tage in daily work routine.
Those features make the cap-ONE P907 an excellent measurement tool in OR, ICU, Recovery Room, PACU, Transport, ER, Cardiac Catheter Laboratory,
GI Endoscopy, Pain Management, Abdominal Operation, Obstetric/Orthopedic/Eye Surgery, Plastic or Dental Surgery.

Supply Code Model Description


P908 TG-921T3 cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients,
semi-quantitative measurement, incl. CO2 sensor and CO2 Adapter,
size: 11 x 11 x 40 mm, cable length: 3.5 m
For Airway Adapters:
Intubated patients: R804
Non-Intubated patients: V921/V922/V923
For current products: all EEG/TEC-5500/7700; EEG-1200/9100/9200
with JE-921A/921AG
Packing unit: 1 pcs

P907 TG-920P cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative
measurement, incl.P923/K984, size: 11 x 11 x 40 mm, cable length: 3.5 m
For Airway Adapters:
Intubated patients: R804
Non-Intubated patients: V921/V922/V923
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

P923 TG-121T cap-ONE CO2 Sensor for Intubated/Non-Intubated Patients, part of CO2 Sensor Kit
P907/P908, cable length: 1.5 m
Requires Adapter Cable: K984
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

K984 JG-920P cap-ONE CO2 Adapter Cable for P923/P907, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
75 Defibrillators > ETCO2 Measurement (Capnography) www.nihonkohden.net

Supply Code Model Description


R804 YG-111T Airway Adapter for P907/P908/P923, intubated, child/adult (> 7 kg),
dead space: 4 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100
Packing unit: 30 pcs

V921 YG-120T CO2 Nasal Adapter for Nasal Breathing, non-intubated, child/adult (> 10kg)
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs

V922 YG-121T CO2 Nasal Adapter for Nasal/Oral Breathing, non-intubated, child/adult (> 10 kg)
For current products:all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs

V923 YG-122T CO2 Nasal Adapter for Nasal/Oral Breathing with Oxygen Cannula Holder,
non-intubated, child/adult (> 10kg)
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100
Packing unit: 30 pcs

NKD-O2-CAP Oxygen Cannula for Nasal Adapter V923 for P907/P908


For current products: all BSM/PMV-2703/OLG-2800/TEC-8300/EEG
Packing unit: 50 pcs

NKD-CO2GAS Calibration Gas for CO2 Measurement


Please store the gas below 50°C!
For current products: all BSM/TEC-8300
Packing unit: 1 pcs

NKD-VENTIL3 CO2 Gas Valve


For current products: all BSM/TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Temperature Measurement

Standard
Temperature

Measurement of
2 Additional Temperatures
77 Defibrillators > Temperature Measurement www.nihonkohden.net

Standard Temperature Measurement


Supply Code Model Description
NKD-P240A YSI-401 Oesophagus/Rectum Thermistor Probe, adult, 6.3 mm jack connector,
size: 4 mm dia, length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-P241A YSI-402 Oesophagus/Rectum Thermistor Probe, neonate/child, 6.3 mm jack connector,


size: 3.3 mm dia, length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-P242B YSI-409B Body Surface Temperature Probe, 6.3 mm jack connector, disk size: 9.5 mm dia,
cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 1 pcs

NKD-P249 ZM: S616 Temperature Probe Cover for NKD-P240A/241A


For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 10 pcs

NKD-TEMPHEARTS4009 Tempheart Adhesive Pads, to fix temperature probes, size: 1.5 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs

NKD-TEMPHEARTS4012 Mini-Tempheart Adhesive Pads, to fix temperature probes, size: 1.13 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs

Measurement of 2 Additional Temperatures


Supply Code Model Description
K961 JT-900P Temperature Connection Cable for NKD-P241/242x, cable length: 0.3 m
For current products: BSM-5100/6000/9100/ TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
NIBP Measurement (Non-Invasive Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition
of the pumping function of the heart as an important vital sign.

A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This me-
thod is using an inflated blood pressure cuff which is applied to the patient’s arm or thigh. The blood pressure is detected
by partial occlusion of the artery by the cuff. The so called Korotkoff sound is generated by the distension of the arterial
wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of
the device based on the mean arterial pressure and changing amplitude of the Korotkoff sounds.

For a proper non-invasive measurement it is important to use the correct cuff size due to the fact that a cuff too small will
lead to faulty high pressure, while a large cuff can lead to wrong low pressure readings.

NIBP Air Hoses

Reusable NIBP Cuffs – NEW YAWARA CUFF 2

Disposable NIBP Cuffs


79 Defibrillators > NIBP Measurement (Non-invasive Blood Pressure) www.nihonkohden.net

NIBP Air Hoses


Supply Code Model Description
S901 YN-900P Child/Adult NIBP Air Hose, cable length: 1.5 m
For current products: all BSM/PVM/TEC-7700/8300
Packing unit: 1 pcs

S902 YN-901P Child/Adult NIBP Air Hose, cable length: 3.5 m


For current products: all BSM/PVM/TEC-7700/8300
Packing unit: 1 pcs

S903 YN-990P NIBP Air Hose Extension Cable, cable length: 1.5 m
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
80 Defibrillators > NIBP Measurement (Non-invasive Blood Pressure) www.nihonkohden.net

Reusable NIBP Cuffs – NEW YAWARA CUFF 2


• Soft and gentalon the skin
• Highly accurate
• Easy to use
Facts
The trade name YAWARA CUFF comes from the Japanese word, YAWARAKAI, which
means soft in touch.
YAWARA CUFF 2 is available in 6 sizes. The exterior size-scale quickly helps in
selecting the proper cuff size, from infant to large adult or thigh.
The velcro part of the cuff is divided into two high quality velcro types. This helps
to fix the cuff on the arm with the first velcro part whereas you can completely
adjust the cuff with the second velcro part.
YAWARA CUFF 2 uses a soft and smooth cloth together with a buffer sheet to reduce
the risk of subcutaneous bleeding. The fabric is hypoallergic and allows the skin to
breathe. Furthermore, the material of the cloth can be easily wiped clean.
A wider opening of the cuff cover allows very easy removal of the bladder for
cleaning.
The watertight connector cap keeps out liquid during cleaning the bladder. There
is a nylon fibre inside the air tube for kink-free tube. There is a nylon fibre inside the
air tube preventing kinking and incidents associated with tube kinking. YAWARA
CUFF 2, a new generation of NIBP cuffs.

Reducing internal bleeding


If wrinkles are formed as below, part of the measuring site may be
trapped in the valley portions of the wrinkles, which could cause internal
bleeding. YAWARA CUFF 2 has a cushion between an inflation bag and skin
to avoid these wrinkles and reduces internal bleeding.

inflation bag
Easy handling of
wrinkles
an inflation bag
With a wide slit, it is easy
to remove and replace the
cushion inflation bladder.

Indicator of appropriate Easy to clean with watertight Kink-free tube


range of attachment site connection cap
With a clear indication of YAWARA CUFF 2 has a watertight YAWARA CUFF 2 has a kink-free
PROPER SIZE printed on the connector cap, which prevents tube. The tube will not
cuff, you can see at a glance fluid from entering the tube (and kinked - even if bent through
if the cuff size is correct for bladder) during cleaning. a 180-degree angle.
your patient.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
81 Defibrillators > NIBP Measurement (Non-invasive Blood Pressure) www.nihonkohden.net

Supply Code Model Description


S951A YP-710T Infant NIBP YAWARA CUFF 2, width: 5 cm, arm-circumference: 8 to 13 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

S951B YP-711T Child NIBP YAWARA CUFF 2, width: 7 cm, arm-circumference: 13 to 19 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

S951C YP-712T Adult Small NIBP YAWARA CUFF 2, width: 10 cm, arm-circumference: 19 to 23 cm,
latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

S951D YP-713T Adult NIBP YAWARA CUFF 2, width: 13 cm, arm-circumference: 23 to 33 cm, latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

S951E YP-714T Adult Large NIBP YAWARA CUFF 2, width: 16 cm, arm-circumference: 33 to 45 cm,
latex-free
For current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 pcs

S951F YP-715T Adult Thigh NIBP YAWARA CUFF 2, width: 19 cm, thigh-circumference: 45 to 55 cm,
latex-free
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
82 Defibrillators > NIBP Measurement (Non-invasive Blood Pressure) www.nihonkohden.net

Disposable NIBP Cuffs


Disposable NIBP Cuffs for Infants & Children

Supply Code Description


NKD-NIBP/K2 Disposable NIBP Cuff Trial Kit for Children
Set contains:
3 cuffs of NKD-S947A
4 cuffs of NKD-S947B
3 cuffs of NKD-S947C
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 set

NKD-S947A Infant NIBP Cuff, width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947B Child NIBP Cuff, width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947C Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm,


color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs D

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
83 Defibrillators > NIBP Measurement (Non-invasive Blood Pressure) www.nihonkohden.net

Disposable NIBP Cuffs for Adults

Supply Code Description


NKD-NIBP/K3 Disposable NIBP Cuff Trial Kit for Adults
Set contains:
1 cuff of NKD-S947C
4 cuffs of NKD-S947D
3 cuffs of NKD-S947F
2 cuffs of NKD-S947H
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 1 set

NKD-S947C Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm,


color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947D Adult NIBP Cuff, width: 14 cm, arm-circumference: 26 to 35 cm,


color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947E Adult Long NIBP Cuff, width: 15 cm, arm-circumference: 29 to 38 cm,


color: red, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947F Large Adult NIBP Cuff, width: 17 cm, arm-circumference: 32 to 42 cm,


color: green, latex-free, disposable
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947G Large Adult Long NIBP Cuff, width: 18 cm, arm-circumference: 35 to 44 cm,
color: orange, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

NKD-S947H Adult Thigh NIBP Cuff, width: 20 cm, arm-circumference: 42 to 50 cm,


color: blue, latex-free
For current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PG
Packing unit: 20 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
IBP Measurement (Invasive Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the
blood pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the
condition of the pumping function of the heart as an important vital sign.

A direct method to measure the blood pressure is the invasive blood measurement using catheters inserted into the
blood vessels, filled with saline solution and measure the pressure electrically with a connected transducer.

Transducer Cable with Direct Connection

IBP Transducer Cable with


Adapter Cable K952
85 Defibrillators > IBP Measurement (Invasive Blood Pressure) www.nihonkohden.net

IBP Transducer Cable with Direct Connection


Supply Code Model Description
K951 JP-900P IBP Connection Cable for Becton Dickinson Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

K952 JP-910P IBP Adapter Cable for IBP Transducer Cables, BF type, cable length: 0.3 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

K957 JP-960P IBP Connection Cable for Biosensors Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

L901 JP-920P IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

L902 JP-921P IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 1.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
86 Defibrillators > IBP Measurement (Invasive Blood Pressure) www.nihonkohden.net

IBP Transducer Cable with Adapter Cable K952


Supply Code Description
NKD-5203201 IBP Connection Cable for B. Braun Transducers, cable length: 3.0 m, requires K952
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-BDP178NK1 IBP Connection Cable Set for Codan Transducers, incl. adapter cable with
1 Pressure Connection, contact board Xtrans BDC901 and holding plate B180090,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 set

NKD-BDP178NK4 IBP Connection Cable for Codan Transducers with 4 Pressure Connections,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-BDPT-1078 IBP Connection Cable for Codan Transducers with 1 Pressure Connection,
cable length: 3.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-6000
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/LOGICAL IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/LOGICAL2 IBP Connection Cable for Medex Transducers with 2 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
87 Defibrillators > IBP Measurement (Invasive Blood Pressure) www.nihonkohden.net

Supply Code Description


NKD-IBP/LOGICAL3 IBP Connection Cable for Medex Transducers with 3 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/LOGICAL4 IBP Connection Cable for Medex Transducers with 4 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/NOVATRANS IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Novatrans
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/TRANSPAC IBP Connection Cable for TRANSPAC Transducers with 1 Pressure Connection,
cable length: ca. 4.5 m, requires K952
Applicable for Abbott Transducers: Transpac IT, Transpac IV
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/TRANSTAR IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Transtar
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/UTAH IBP Connection Cable PMK225 for Pulsion Transducers for PiCCO 2 and PiCCO plus
with 1 Pressure Connection, cable length: 3.0 m, requires K952 and NKD-IBP/UTAH2
Applicable for Pulsion Transducers for PiCCO: PV81x, PV82xx
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

NKD-IBP/UTAH2 AUX Adapter Cable PC85200 to External Monitor for Pulsion PiCCO 2,
cable length: 0.3 m, requires NKD-IBP/UTAH
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
88 Defibrillators > Portable CPR www.nihonkohden.net

Portable CPR – For use by anyone!


Reusable, portable and smart – a simple and fast emergency aid tool for chest compression!

For inexperienced users, for first aid trainings, in hospitals, airports and aircrafts/trains and/or for rescue operations.

Continuous acoustic and visual real time feedback for compression


frequence and depth during chest compression
(metronome/verbal directions/light-emitting diodes)

Perfecting of chest compression effectiveness


(ideal compression depth 4 - 5 cm, 100 compressions/minute)
complies with current ERC Guidelines

Ideal tool for professionals and inexperienced users due to


continuous real time feedback during chest compression

Enhancement of patient status due to optimized quality and


effectiveness of chest compression (detectable with ETCO2 value) NKD-CPR
• Applicable to adults and children from 8 years!
• 10 hours non-stop operation (acoustic warning) or up to 5 years stand-by time!
• Available in 17 different languages!
(stock: German, English, Italian, French, Spanish; on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian,
Polish, Portuguese, Russian, Swedish, Hebrew, Croatian)

Only a few steps may help save a life:


• Stay calm!
• Check the responsiveness/consciousness of the person with cardiac arrest (victim)!
• Call to an emergency doctor! / Call for help!
• If available, use an AED (defibrillator for inexperienced users with verbal directions / visual aid) and a Pocket CPR!
• Check the breathing of the concerned person (victim) and free the airway if necessary!
• Start chest compression (30 x) and perform rescue breathing to the victim (2 x)!
• Continue with chest compressions and rescue breaths in a ratio of 30:2
(30 chest compressions, 2 rescue breaths) until the appearance of the emergency doctor!

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
89 Defibrillators > Portable CPR www.nihonkohden.net

Portable CPR
Supply Code Description
NKD-CPR Portable CPR
Please indicate your language when ordering!
Available languages on stock : German, English, French, Italian, Spanish
Available languages on request: Danish, Finnish, Dutch, Hungarian, Czech,
Norwegian, Polish, Russian, Swedish, Hebrew, Croatian
Packing unit: 1 pcs

NKD-SIPADS Disposable Silicone Pads for Portable CPR, 3 mm self-adhesive silicone pads for
optimal placement of the Portable CPR on patients chest
Packing unit: 5 pcs

NKD-STPADS Disposable Sticky Pads for Portable CPR, thin self-adhesive pads for optimal
placement of the Portable CPR on patients chest
Packing unit: 50 pcs

NKD-CPR/COVER Silicone Cover for Portable CPR


Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Additional Defibrillator Accessories
91 Defibrillators > Additional Defibrillator Accessories www.nihonkohden.net

Additional Defibrillator Accessories


Supply Code Model Description
F015 Z-101EA “Gelaid” Defibrillator Contact Gel, 100 g tube
For current products: all TEC
Packing unit: 5 pcs

NKD-JJ221V R2 Adapter Cable for Laerdal/Ambu Training Doll, requires R2


Adapter cable JC-755V/K342A
For current products: TEC-5500/7700/8300
Packing unit: 1 pcs

NKD-L936 Power Cable, Schuko plug, cable length: 2.0 m


Packing unit: 1 pcs

NKD-POWERLINE Multiple Power Socket (4 slots), medical certification


For current products: all TEC
Packing unit: 1 pcs

NKD-SD1GB Memory SD Card 1 GB


Packing unit: 1 pcs

Y011 404617 Thermal Head Cleaner Pen


For current products: all ECG/TEC/old MEB/EEG/all BSM/PVM/OPV/WEP
Packing unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Accessories for AED & Training Unit
Dont let premature death
claim the lives around you
Sudden Cardiac Arrest (SCA) is among the leading causes of death in the
world. In SCA, the heart suddenly and unexpectedly stops functioning.
When this happens, the heart is no longer able to pump blood to the rest
of the body. This usually results in death if not treated within minutes.

Heavy chest pains, nausea and weakness are common symptoms of SCA.
More often than not, the victim also feels an impending sense of doom
reflecting their predicament.

SCA can strike anytime and any place, and can happen to anyone.

Dont let SCA claim lives prematurely when something can be done about it.

ACT NOW!
Give every life a chance to live.
94 Defibrillators > Accessories for AED & Training Unit www.nihonkohden.net

A strong Chain of Survival


improves chance of survival

The “Chain of Survival” is a proven approach to the early treatment of sudden cardiac
arrest, heart attack, stroke and any other emergency. It consists of four crucial links:

EARLY ACCESS EARLY CPR EARLY DEFIBRILLATION EARLY ACLS


to get help to buy time to restart heart to stabilize

1. Early Access - to activate the Emergency Medical Services (EMS).


2. Early Cardiopulmonary Resuscitation (CPR) – to slow the rate of deterioration
of the brain and heart, and buy time to enable defibrillation.
3. Early Defibrillation – to restore to a normal heart rhythm.
4. Early Advanced Cardiac Life Support (ACLS) – to stabilise the patient.

Any delay in any of these links could potentially be fatal or decrease the chance of survival.
Most people who die of heart attacks experience irregular heartbeats known as ventricular
fibrillation (VF); a condition where the heart stops circulation of blood. lf left untreated, the
victim will die within minutes. By far, defibrillation (electric shock) is the only known treat-
ment to revert a troubled heart from VF to its normal rhythm.

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
95 Defibrillators > Accessories for AED & Training Unit www.nihonkohden.net

Importance of AED in the Chain of Survival

Automated External Defibrillator or AED is perhaps the most important


link in the chain to improve the SCA victim‘s survival chances.
An AED is a device that is used to diagnose and treat potentially life thre-
atening abnormal heart rhythms by providing the means to apply con-
trolled electrical shocks (known as defibrillation shocks) to the heart in
an attempt to stop these abnormal rhythms, thereby allowing the heart
to establish again an effective rhythm.
It will also provide guidance by simple and clear vocal instructions to the
rescuer during the rescue sequence.
Studies have shown that the time to first defibrillation shock is the most
crucial factor in determining survival rates for SCA*. When an AED is
available, it should always be applied to the SCA victim at the earliest.

* Report of Japan FDMA (Fire and Disaster Management Agency/2008)


50,0%

45,0%
43,8%
For over 90% of SCA cases,
40,0% death usually occurs if
35,0%
without intervention.
However, as many as
30,0% 38,2% 30-50% would likely
survive if AED and CPR
25,0%
was administered within
20,0% first 5 minutes of collapse.
Survival chance can
15,0% be significantly increased
with early defibrillation.
10,0%
9,8% Use AED
0,5%
5,6% Non use AED
0
Survival rate Rehabilitation rate
(after 1 month) (after 1 month)

For every minute of delay in giving CPR and defibrillation following collapse, the survival rate
decreases by 7–10%. So, why let tragedies happen where there is prevention available now?
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
The result
Reusable ofarenot
accessories having
intended for repeatedan AED
patient use onmay
different well be another
patients during fatalPlease
different examinations. case.make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
96 Defibrillators > Accessories for AED & Training Unit www.nihonkohden.net

Accessories for AED Units


Supply Code Model Description
H324A P-530K Defibrillation Pads, child/adult, for use with adapter cable JC-765V/K342B,
weight: 85 g ± 15 g), size: 109 mm x 15 mm (± 10 mm),
conductive surface: 86.68 cm2 (±10%), cable length: 1.5 m
For current products: AED-21xx
Packing unit: 1 pair

SB-210VK X212A 2-Years Standby Battery for all devices until SN: 5000
For current products: AED-21xx
Packing unit: 1 pcs

SB-212VK X216A 2-Years Standby Battery for all devices starting from SN: 5001
For current products: AED-21xx
Packing unit: 1 pcs

SB-214VK X217A 4-Years Standby Battery for all devices starting from SN: 5001
For current products: AED-21xx
Packing unit: 1 pcs

Y184A YC-210V AED Carrying Bag.


AED usage is possible without taking
out from the bag!
For current products: AED-21xx
Packing unit: 1 pcs

Accessories for AED Training Unit TRN-2100K


Supply Code Description
H326 Training Pads, child/adult
For current products: TRN-2100K
Packing unit: 1 pair

Y262B Replacement Stickers for TRN-2100K Training Pads


For current products: TRN-2100K
Packing unit: 10 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
www.nihonkohden.net

ACCESSORY ORDER FORM


For your convenience we have a printable order form so that you can fax in your order directly or mail/e-mail it to us.
Please make sure to fill out all the information requested below!

Hospital/Practice

Contact Person Department

Customer Code Address

ZIP City

Phone Fax

E-Mail

ACCESSORY ORDER FORM

Standard 3 Days 2 Days Overnight

Monthly, please contact me for more details Other

Supply Code Description Required Quantity Price each in EUR / £ Price Total in EUR / £

Send in your order today! For Germany, Austria, Switzerland and Benelux For France
Fax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de Fax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.fr
For Spain and Portugal For Italy
Fax: +34 91 300 46 76, E-Mail: info@nkib.es Fax: +39 (0) 35-232546, E-Mail: info@nkitaly.com
For United Kingdom For all other European Countries, Russia, Turkey
Fax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk and Israel
Fax: +49 (0) 6003/827-599, E-Mail: info@nke.de
98 Index as per Supply Code www.nihonkohden.net

Index as per Supply Code

Supply Code page Supply Code page Supply Code page Supply Code page

6124-039432 47 JC-755V 39 K901 48 KB18B 14

A052 25 JC-765V 38 K910A 47, 50 KB19C 14


A053 25 K079 13 K910A 47, 50 L151 52
A128 25, 34 K081 13 K911 47, 50 L152 52
A129 25 K082 13 K912 47 L153 52
A222 34 K093C 13 K913A 47 L901 85
A226 34 K093D 13 K915 48 L902 85
A238 34 K093F 13 K922 48 N-00 21
F010 28 K093L 14 K931 58 N-08 21
F015 91 K096A 13 K951 85 ND-593V 42
G203 20, 54 K096B 13 K952 85 ND-594V 42
G204 20, 54 K097 15 K957 85 ND-595V 42
G207 20, 54 K098 15 K961 77 ND-596V 42
G210C 21, 55 K117A 29 K981 72 ND-597V 42
G210D 20 ,54 K117B 29 K984 74 ND-612V 42
G236 20 K117C 29 K987 73 ND-893V 41
G250 20, 54 K118 14 KB01A 14 ND-894V 41
G271A 55 K119 14 KB02A 14 ND-895V 41
G272A 54 K120 47, 50 KB03A 14 ND-896V 41
G272B 54 K225 50 KB04A 14 ND-897V 41
G272C 55 K226 50 KB05A 14 NKD-145-2,5 26
G278A 55 K227 51 KB06A 14 NKD-145-6A300 26
H041A 18 K228 51 KB07A 14 NKD-210-10/295 25
H043A 18 K232 52 KB08A 14 NKD-210-5-295 25
H044A 18 K234 52 KB09A 14 NKD-5203201 86
H044B 18 K332 52 KB010 14 NKD-63 26
H049 18 K336 50, 51 KB012 14 NKD-A054 25
H052A 18 K342A 39 KB10C 14 NKD-A129 26
H052B 18 K342B 38 KB11C 14 NKD-A134A 26
H068A 17 K350A 52 KB12D 14 NKD-A226 34
H068B 17 K351A 52 KB13B 14 NKD-A730 25
H072 17 K352A 50 KB13D 14 NKD-BAG 28
H312 38 K352B 51 KB14B 14 NKD-BDP178NK1 86
H324A 96 K353A 50 KB15B 14 NKD-BDP178NK4 86
H326 96 K353B 51 KB16B 14 NKD-BDPT-1078 86
H327 38 K354 48 KB17B 14 NKD-CO2GAS 75
99 Index as per Supply Code www.nihonkohden.net

Index as per Supply Code

Supply Code page Supply Code page Supply Code page Supply Code page

NKD-CPR 89 NKD-S947E 83 P229A 65 V923 75


NKD-CPR/COVER 89 NKD-S947F 83 P229B 67 X040 23
NKD-DEFIBAG2 36 NKD-S947G 83 P259 65, 67 X041 32
NKD-DEFIBAG3 36 NKD-S947H 83 P263 62 X041A 23
NKD-DEFIBAG6 36 NKD-SD1GB 28, 91 P267 62 X041B 23, 32
NKD-DEFIBAG83 36 NKD-SIPADS 89 P310C 62 X060A 32
NKD-ECG/TAB1 19 NKD-STPADS 89 P311C 62 X065 23, 32
NKD-ECG/TAB2 19 NKD-STRAP83 36 P903 72 X071 23
NKD-G711 28 NKD-TEMPHEARTS4009 77 P906 72 X073 23
NKD-H/ADAPTER2 19 NKD-TEMPHEARTS4012 77 P907 74 X077 32
NKD-H405 39 NKD-VENTIL3 75 P908 74 X078 23
NKD-H406 39 NKD-Z715 19 P909 73 Y011 28, 91
NKD-IBP/LOGICAL 86 NKD-Z722 19 P922A 72 Y095A 58
NKD-IBP/LOGICAL2 86 NKD-Z723 19 P923 74 Y184A 96
NKD-IBP/LOGICAL3 87 P203A 63 P924 73 Y206A 38
NKD-IBP/LOGICAL4 87 P203B 63 R801 72 Y206B 39
NKD-IBP/NOVATRANS 87 P203C 63 R804 75 Y262B 96
NKD-IBP/TRANSPAC 87 P203D 63 R805 73
NKD-IBP/TRANSTAR 87 P203E 64 S901 79
NKD-IBP/UTAH 87 P203F 64 S902 79
NKD-IBP/UTAH2 87 P203G 64 S903 79
NKD-JJ221V 91 P203H 64 S951A 81
NKD-L936 28, 91 P204A 64 S951B 81
NKD-NIBP/K2 82 P204B 64 S951C 81
NKD-NIBP/K3 83 P204C 65 S951D 81
NKD-O2-CAP 75 P204D 65 S951E 81
NKD-P240A 77 P204E 66 S951F 81
NKD-P241A 77 P204F 66 SB-210VK 96
NKD-P242B 77 P204G 66 SB-212VK 96
NKD-P249 77 P204H 66 SB-214VK 96
NKD-POWERLINE 28, 91 P225F 61 SB-551V 32
NKD-S947A 82 P225G 61 SB-801V 32
NKD-S947B 82 P225H 61 SC-831V 32
NKD-S947C 82, 83 P228A 65 V921 75
NKD-S947D 83 P228B 67 V922 75
100 Index as per Model Code www.nihonkohden.net

Index as per Model Code

Model Code page Model Code page Model Code page Model Code page

404617 28, 91 C-150 20, 54 NC-124D 18 TL-630T3 62


490933 13 F-150M 20, 54 NKB-102V 32 TL-631T3 62
6144-000427 18 F-150S 21, 55 NKB-301V 23, 32 V-040M4 54
6144-011852 18 FQS50-2-100 34 P-511 38 V-06OM6 55
669269 13 FQS50-3-100 34 P-513 38 V-09IO3 55
AX-250V 38 FQW210-10-295 25 P-530K 96 V-09OM3 54
AX-251V 39 FQW210-30-295 25 PS50-2 34 V-120S3 55
BC-753V 52 J-150 20, 54 RQS50-3 25, 34 X212A 96
BC-755V 52 JC-002P 52 RQS63-3 25 X216A 96
BC-763V 50 JC-005P 50, 51 SB-150D 23 X217A 96
BC-763VA 50 JC-761V 52 SB-201D 23 YC-210V 96
BC-765V 51 JC-762V 52 SB-831V 32 YG-101T 72
BC-765VA 51 JC-763V 52 SB-901D 23 YG-111T 75
BJ-831V 48 JC-855V 39 TG-101T 72 YG-120T 75
BJ-900P 48 JC-865V 38 TG-121T 74 YG-121T 75
BJ-901D 13 JC-906P 48 TG-221T 73 YG-122T 75
BJ-902D 13 JG-900P 72 TG-900P 72 YG-211T 73
BJ-903D 13 JG-920P 74 TG-901T3 72 YN-900P 79
BJ-904D 15 JG-970P 73 TG-920P 74 YN-901P 79
BM-901D 15 JL-550T2 58 TG-921T3 74 YN-990P 79
BR-002P 52 JL-900P 58 TG-970P 73 YP-710T 81
BR-004P 52 JP-900P 85 TL-051S 65 YP-711T 81
BR-018P 50 JP-910P 85 TL-052S 67 YP-712T 81
BR-019P 50 JP-920P 85 TL-061S 65 YP-713T 81
BR-020P 51 JP-921P 85 TL-062S 67 YP-714T 81
BR-021P 51 JP-960P 85 TL-201T 61 YP-715T 81
BR-202D 14 JT-900P 77 TL-201T1 61 YS-093P2 62
BR-903P 47, 50 L-150 20, 54 TL-220T 61 YSI-401 77
BR-906P 47 L-150X 20, 54 TL-271T 63, 64 YSI-402 77
BR-906V 47 LC-S2912NK 23, 32 TL-271T3 64, 66 YSI-409B 77
BR-912D 13 LCS-2012NK 23 TL-272T 63, 64 Z-101BC 28
BR-913D 13 LCT-1912ANK 23 TL-272T3 64, 66 Z-101EA 91
BR-913E 13 LCT-1912NK-1 32 TL-273T 63, 65 ZM: S616 77
BR-913P 47, 50 M-150 20 TL-273T3 64, 66
BR-916P 48 NA-0003 47 TL-274T 63, 65

BR-921D 14 NA-0003 50 TL-274T3 64, 66


For Germany, Austria, Switzerland and Benelux For France
NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland NIHON KOHDEN FRANCE SARL
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland 8, rue François Delage, 94230 Cachan, France
Fax: +49 (0) 33203/573-19, E-Mail: bestellung@nke.de Fax: +33 (0) 1 49 08 93 32, E-Mail: info@nkfrance.fr
For Spain and Portugal For Italy
NIHON KOHDEN IBERICA S.L. NIHON KOHDEN ITALIA S.r.l.
C/Ulises, 75A, 28043 Madrid, Spain Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +34 91 300 46 76, E-Mail: info@nkib.es Fax: +39 (0) 35-232546, E-Mail: info@nkitaly.com
For United Kingdom For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN UNITED KINGDOM Ltd. NIHON KOHDEN EUROPE GmbH
Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Surrey KT6 7EL, United Kingdom Fax: +49 (0) 6003/827-599, E-Mail: info@nke.de
Fax: +44 (0) 20 83 90 46 75, E-Mail: mail@nihonkohden.co.uk

NKE-BRZ-K/A

Anda mungkin juga menyukai