Anda di halaman 1dari 1

B30 B30 B30

B30
B30 B30 B03 B05 B06
B04
B01 B02

E.M.D.B. ROOM
NOVEC CLOSET
00 B30-07-02 C
00 B30-07-06 C

B30
A08

GENERATOR ROOM
00 B30-07-01 C

ELEC. ROOM
00 B30-10-01 C

BUILDING 30 REFER TO B32


C01
BUILDING 04 REFER TO
SHEET 1101 DN
SHEET 1104
MECH. ROOM B32
00 B30-07-04 C C02
Copyright by the Supreme Committee for Delivery & Legacy (SC). All rights reserved. This document may
not, in whole or in part, be reproduced, stored, transmitted or distributed in any form or by any means,
whether electronic, mechanical, by photocopy, recording or otherwise, without the prior written permission
B32 of SC. Except where otherwise expressly agreed in writing by SC, SC shall have no responsibility or liability
C03
B32 for any loss (direct, consequential or otherwise) which may arise from reliance on or use of this document or
X01 the information contained therein.
MECH. ROOM
B32 A
00 B32-04-02
X02 DO NOT SCALE THIS DRAWING.
B32
B30 C04
A08
L.V. CABLE ENTRY ROOM
00 B32-05-01 C NOVEC CLOSET
00 B32-05-02 C

B32 ENGINEERING DEPARTMENT 1103 1110 1112 1113


B30 ELEC. ROOM 1101
1114
A09
C05 00 B32-04-03 A

?
?
? ?
00 P01-05-03 D

N 1104 1106
1108 1117

M7 1102 1111 1115 1116 1118


1105 1107 1109
B32 B32
X06 X05

C
C
C T1

Notes
SERVICE ROOM ? 1- FOR GRAPHICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES REFER TO DWG. NO. DPP-DAH-D-MDP-L-EL-AL-AZ -0001.
00 P01-05-02 C ? ? ? 2- FOR EARTHING SYSTEM SCHEMATIC DIAGRAMS REFER TO DWG.NO. DPP-DAH-D-MDP-L-EL-AL-AZ-7001 TO 7005.
3- FOR L.V. SCHEMATIC DIAGRAMS REFER TO DWG. NO. DPP-DAH-D-MDP-L-EL-AL-AZ-7021 TO 7025.
B32 4- FOR EMERGENCY L.V. SCHEMATIC DIAGRAMS REFER TO DWG. No. DPP-DAH-D-MDP-L-EL-AL-AZ-7026 TO 7028.
CINEMA 01
D01 5- FOR EARTHING SYSTEM DETAILS AND TYPICAL LOW VOLTAGE SURGE PROTECTION REFER TO DETAILS DRAWINGS.
00 B32-04-01 A 6- PROTECTIVE EARTH CONDUCTORS SHALL BE RUN WITH THE PHASE CONDUCTORS SIZED AS PER CODE AND AS INDICATED ON DRAWINGS.
7- MAIN EARTH LOOP SHALL BE BARE COPPER CONDUCTOR INSTALLED AT A DEPTH OF 0.5m AND A DISTANCE OF 1m AROUND EXTERNAL WALLS, UNLESS
ATS ELEC. CLOSET
OTHERWISE INDICATED ON DRAWINGS.
00 B32-04-28 A 8- OVERALL RESISTANCE TO EARTH OF THE GROUND ELECTRODE SYSTEM SHALL NOT EXCEED 1 OHM, UNLESS OTHERWISE APPROVED BY QATAR GENERAL
MECH. ROOM
MAINTENANCE DEPARTMENT ELECTRICITY & WATER CORPORATION "KAHRAMAA".
00 P01-05-01 D 9- WHERE GROUND CONDITIONS MAKE IT DIFFICULT TO ACHIEVE THE REQUIRED RESISTANCE TO EARTH, SUITABLE BACKFILL MATERIAL SHALL BE USED AS
00 B32-04-04 A
REQUIRED TO BRING DOWN THE EARTH RESISTANCE TO THE SPECIFIED VALUE, SUBJECT TO THE ENGINEER'S APPROVAL.
10- EACH EARTH ELECTRODE SHALL BE DRIVEN TO A DEPTH SUCH THAT IT PENETRATES THE SUMMER WATER TABLE BY A MINIMUM OF 2m AS PER KAHRAMAA
MAIN EARTH BAR FOR REGULATIONS.
( MECHANICAL EQUIPMENT ) A 11- THE DESIGN IS BASED ON EARTH RODS WITH DIMENSIONS AS FOLLOWS:
- TYPE A: 16mm DIAMETER AND 3600MM LENGTH (SEALED INSPICTION PITS).
A - TYPE B: 16mm DIAMETER AND 4800MM LENGTH (SEALED INSPICTION PITS).
- TYPE C: 16mm DIAMETER AND 6000MM LENGTH (NON-SEALED INSPICTION PITS).
B32
D02
A 12- EACH EARTH ELECTRODE SHALL BE PROVIDED WITH A DEDICATED TEST LINK AND INSPECTION PIT AS PER KAHRAMAA REGULATIONS.
13- CONTRACTOR IS RESPONSIBLE TO PROVIDE COMPLETE EARTHING SYSTEM IN ACCORDANCE TO BS 7430 AND LOCAL REGULATIONS. ALL NECESSARY
SERVICE CORRIDOR
EQUIPMENT AND ACCESSORIES ARE CONSIDERED PART OF THE CONTRACTOR'S SCOPE.
00 B32-06-01 C
MECH. ROOM
T1 ELEC. ROOM 00 P01-04-17 C
CORRIDOR
MAIN EARTH BAR FOR 00 P01-01-02 C
( MECHANICAL EQUIPMENT ) 00 P01-05-27 C

TO SUBSTATION EARTHING (REFER


TO DRAWING NO. Z.V. ROOM
DPP-DAH-D-MDP-L-EL-00-AZ-1105 00 P01-04-16 C
MECH. ROOM
B32 U.P.S. ROOM
B05 00 B32-06-06 C
X07 00 P01-01-01 C
Y43 T1
Legend
B32
D03 N.O.C. ROOM STAIR
NOVEC CLOSET
00 P01-02-01 C 00 P01-05-25 D
00 P01-04-14 C
L.C. ROOM
00 P01-01-28 C
B32 SUMP PIT ROOM
X09 00 B32-06-05 C

LOBBY
00 P01-02-02 C

OPERATION ROOM
00 P01-02-04 C

SERVICE CORRIDOR SERVICE CORRIDOR


MAIN EARTH BAR 00 P01-05-28 C B32
B32 00 B32-06-04 C
D04
FOR L.C. ROOM A01
B05
Y44

NOVEC CLOSET
00 P01-04-12 C
C.M.S. ROOM
00 P01-02-03 C

B32
A02
MAIN EARTH BAR FOR
B.O.H. (CMS ROOM EQUIPMENT)
B32 00 B32-01-02 A
Y01

NOVEC CLOSET
00 P01-04-13 C
No Description
B32
A03 SAFETY, HEALTH AND ENVIRONMENT INFORMATION
? Brief details on the identified hazard symbol referencing the unusual residual hazards / risks are listed above.
? ? ?

F&B
00 B32-01-01 A

B.O.H. MECH. ROOM MECH. ROOM


MECH. ROOM 00 B32-02-02 A 00 B32-02-03 A 00 P01-03-01 C
00 B32-01-03 A SERVICE CORRIDOR
00 P01-05-21 C
SERVICE CORRIDOR
00 B32-06-02 C
T1 AS SHOWN CLOUDED M.K. T.M. 15/05/2018
T0 ISSUED FOR TENDER M.K. T.M. 08/02/2018
B32 Rev Description Apvr Chk'd Date
Y02
Client
B32
A04
MECH. ROOM
00 B32-04-05 A B32 Supreme Committee For
ELEVATOR SHAFT
A05 Delivery & Legacy
00 B32-06-07 A MECH. ROOM

B32 00 B32-03-03 A
Y03
SERVICE ROOM
B32 00 B32-06-03 C
Y04
B32
Project Manager
A06

B.O.H.
B32
Y05 00 B32-03-02 A
FAST FOOD
ARCADE
00 B32-02-01 A
00 B32-01-04 B
Design Consultant
B32
A16
B32
Y06

B05
FAST FOOD
00 B32-03-01 A
BUILDING 33 REFER TO Design Consultant Dar Al Handash
DOHA - CAIRO - BEIRUT
www.dargroup.com
- LONDON

Y07
B32
A07
SHEET 1105 Project Title
DOHA PORT REDEVELOPMENT PROJECT - DOHA
Doha, Qatar

Drawing Title GROUND FLOOR PLAN


B32
A08
Stage TENDER DOCUMENTS
B32
B32
A09 SUB PROJECT MINA DISTRICT PACKAGE
B01
Type FLOOR PLAN
B32
A10
B32 Description EARTHING SYSTEM LAYOUT - BUILDING ( 32)
B02

B32 PART 02/18


B32 A11
B03
Purpose of Issue Seal Date

B32
STAGE GATE 08/02/2018
B32
A12
B04
Designed Drawn Checked
B32
B05 H.A. / A.M. M.E. T.M.
B32
B32
A13 Model File Ref: Scale A0 (841x1189) Revision No
B06
1 : 100
B32
B32
B07
B32
B08
A14
Drawing No T1
DPP-DAH-D-MDP-L-EL-00-AZ-1102