Anda di halaman 1dari 31

Isi Hal.

Tujuan .................................................................................................................................................. 2
SIMATIC Overview ............................................................................................................................ 3
S7-200™ ............................................................................................................................................. 4
S7-200™: Modules: S7-21x Series .................................................................................................. 5
S7-200™: Modules: S7-22x Series ...............................................................................................… 6
S7-200™: CPU Design: S7-21x Series ............................................................................................ 7
S7-200™: CPU Design: S7-22x Series ............................................................................................ 8
S7-300™ .............................................................................................................................................. 9
S7-300™: Modules ........................................................................................................................... 10
S7-300™: CPU Desain ....................................................................................................................... 11
S7-400™ ............................................................................................................................................. 12
S7-400™: Modules ........................................................................................................................... 13
S7-400™: CPU Desain ..................................................................................................................... 14
Perangkat Pemrograman ..................................................................................................................... 15
Persyaratan untuk Instalasi STEP 7 di PG/PC ……........................................................................... 16
Installasi perangkat Lunak pada STEP 7 ............................................................................................ 17
Hasil Instalasi ....................................................................................................................................... 18
Tool / Alat pada STEP 7 ...................................................................................................................... 19
Dari Proses ke Proyek.......................................................................................................................... 20
Strutur Proyek STEP 7.......................................................................................................................... 21
Memulai SIMATIC® Manager............................................................................................................... 22
Menu SIMATIC® Manager dan Toolbars …....………......................................................................... 23
Toolbar pada SIMATIC® Manager...................................................................................................... 24
Membuat Projek S7 …......................................................................................................................... 25
Menyisipkan sebuah Blok Program pada S7....................................................................................... 26
Tampilan Offline / Online pada SIMATIC® Manager ........................................................................... 27
Standard Library .......………........……................................................................................................. 28
Latihan : Membuat sebuah Projek ....................................................................................................... 29
Latihan : Menyisipkan sebuah Program S7 ........................................................................................ 30
Latihan : Mengkopi sebuah Blok dari Standard Library......................................................................... 31

MPSL Intermediate
Maintenance Personel Skill Level Page 1 SIMATIC® Manager
MPSL Intermediate
Maintenance Personel Skill Level Page 2 SIMATIC® Manager
Pengenalan Di masa lalu, tugas kendali diselesaikan dengan individu Kontrol Logika
terisolasi Programmable (PLC) untuk mengontrol mesin atau proses. Saat ini
agar perusahaan untuk tetap kompetitif, tidaklah cukup untuk mengotomatisasi
hanya stasiun pemrosesan berdiri sendiri atau mesin secara terpisah. Tuntutan
untuk fleksibilitas yang lebih dengan produktivitas yang lebih tinggi agar dapat
terpenuhi dengan mesin individu yang terintegrasi dalam suatu sistem secara
menyeluruh.

Otomasi Terintegrasi Totally Integrated Automation (TIA) menyediakan secara umum pada
Secara Menyeluruh lingkungan softwarenya, yang mengintegrasikan semua komponen, meskipun
keanekaragaman teknologi yang diterapkan, ke dalam satu sistem yang
seragam. Ini menyatukan semua yang anda perlu program, mengkonfigurasi,
mengoperasikan, menangani data, berkomunikasi, dan memelihara solusi
kontrol Anda.
Step 7 SIMATIC Manager, bekerja pada Siemens PGs atau PCs, menyediakan
seperangkat alat yang terintegrasi untuk semua sistem komponen yang
memungkinkan untuk mempermudah pembuatan, pengujian, start-up,
pengoperasian dan solusi pemeliharaan sistem kendali anda. Sementara Anda
mengkonfigurasi dan memprogram, perangkat lunak Siemens menempatkan
semua data Anda dalam sebuah pusat data yang mana dapat diakses oleh
semua peralatan.

Database Terpusat Sebuah database yang umum dari semua komponen Sistem Otomasi yang
terintegrasi secara Terpadu/ Menyeluruh yang mana data hanya dimasukkan
sekali dan kemudian tersedia untuk seluruh proyek. Integrasi secara total dari
seluruh lingkungan otomatisasi ini dimungkinkan dengan bantuan dari:
• Satu software yang umum (Step 7 SIMATIC Manager) yang
mengintegrasikan semua komponen dan tugas ke dalam satu sistem yang
seragam dan mudah digunakan.
• Manajemen Data yang Umum.
• Standart protokol yang terbuka seperti Ethernet, PROFIBUS, MPI, AS-I
yg menghubungkan seluruh komponen ke lainnya, dari level management
sampai ke lapangan.
MPSL Intermediate
Maintenance Personel Skill Level Page 3 SIMATIC® Manager
Bentuk • Modular small control system untuk performa dengan range paling rendah.
• Performa-graded range CPUs (diatas 8KB memory, 8-40 terintegrasi
I/O terpasang pada CPU).
• Masing – masing CPU tersedia dengan tegangan power supply 24 VDC
atau 120 VAC - 230 VAC .
• Desain dapat diupgrade sampai dengan tujuh modul ekspansi tergantung
pada CPU (tidak dengan CPU 210 atau CPU 221).
• Ekstensif seleksi modul . Catatan: Penggunaan kombinasi CPU dan modul
dari seri S7-21x dengan seri S7-22x TIDAK memungkinkan!
• CPU terhubung ke modul terintegrasi dengan kabel pita yang fleksibel (S7-
22x seri) dan dengan bus konektor (S7-21x seri).
• Kemampuan Jaringan - RS 485 interface komunikasi (bukan CPU 210)
- PROFIBUS slave (CPU 215 atauCPU 222 atau
lebih besar)
• Koneksi terpusat PG/PC dapat mengakses seluruh modul.
• Menggunakan software tersendiri S7 Micro/WIN32, oleh karena itu STEP
7™ tidak diperlukan.
• “Total Paket” (brick) dengan power supply, CPU dan terintegrasi I/O dalam
satu paket.
• Password proteksi user program - sampai 3 levels.

MPSL Intermediate
Maintenance Personel Skill Level Page 4 SIMATIC® Manager
Expansion • Digital input modules:
Modules (EM) - 24 VDC
- 120/230 VAC
• Digital output modules:
- 24 VDC
- Relay
• Analog input modules:
- Voltage / tegangan
- Current / arus
- Resistance / tahanan
- Thermocouple
• Analog output modules:
- Voltage / tegangan
- Current / arus

CPU S7-21x seri hanya dapat diperpanjang dengan modul ekspansi S7-21x
seri. Catatan: Penggunaan kombinasi CPU dan modul dari seri S7-21x dengan
seri S7-22x TIDAK memungkinkan!

Communications Anda dapat menggunakan CP 242-2 untuk secara signifikan menambah jumlah
Processors (CP) input / output SIMATIC S7-200™ (S7-21x series). CP bertindak sebagai master
untuk sebuah aktuator dan sensor interface (AS-Interface). Hasilnya, 31 AS-
Interface slave dapat mengendalikan hingga 248 elemen biner.

Aksesoris Bus connector (hanya S7-21x series)

MPSL Intermediate
Maintenance Personel Skill Level Page 5 SIMATIC® Manager
Expansion • Digital input modules:
Modules (EM) - 24 VDC
- 120/230 VAC
• Digital output modules:
- 24 VDC
- Relay
• Analog input modules:
- Voltage / tegangan
- Current / arus
- Resistance / tahanan
- Thermocouple
• Analog output modules:
- Voltage / tegangan
- Current / arus

CPU S7-22x series (CPU 222/224/226) hanya dapat diperpanjang


menggunakan modul ekpansi S7-22x series. Catatan: Penggunaan kombinasi
CPU dan modul dari seri S7-21x dengan seri S7-22x TIDAK memungkinkan!

Communications Pada S7-22x series dapat menggunakan CP 243-2 untuk menghubungkan S7-
Processors (CP) 200™ sebagai Master ke AS-Interface. CP243-2 terbaru mensupports sampai
diatas 62 AS-Interface slaves yang terhubung (max. 31 analog slaves). Diatas
tiga (CPU 224, CPU 226) CP243-2 processors dapat dioperasikan bersamaan
dengan S7-200 CPU ini.

EM277 PROFIBUS-DP module memungkinkan koneksi S7-22x series CPU


(6ES7-22x-xxx21-xxxx dan terakhir) ke PROFIBUS-DP (sebagai slave) dan
MPI. Secara Simultan bisa sebagai MPI slave dan PROFIBUS-DP slave.
PROFIBUS-DP mensupport transfer data rate sampai 12 Mbits/detik.

MPSL Intermediate
Maintenance Personel Skill Level Page 6 SIMATIC® Manager
Mode Selector Untuk manual mode selection:
STOP = Stop mode, program tidak di eksekusi.
TERM = Eksekusi Program , memungkinkan akses read/write dari PG.
RUN = Eksekusi Program, memungkinkan akses baca saja dari PG.

Status Indicators SF = Group error; internal CPU fault; red


(LEDs) RUN = Run mode; hijau
STOP = Stop mode; kuning
DP = PROFIBUS-DP ( hanya CPU 215)

Memory Card Slot memory card. Memory card menyimpan isi program pada saat power tidak
ada tanpa membutuhkan batere.

PPI Connection Programming device, tampilan text, atau CPU yang lain dihubungkan disini.

MPSL Intermediate
Maintenance Personel Skill Level Page 7 SIMATIC® Manager
Mode Selector Untuk manual mode selection:
STOP = Stop mode, program tidak dieksekusi.
TERM = Eksekusi Program ‚ dapat mengakses read/write dari PG.
RUN = Eksekusi Program, hanya dapat akses membaca /read dari PG.

Status Indicators SF = Group error; internal CPU fault; merah


(LEDs) RUN = Run mode; hijau
STOP = Stop mode; kuning
DP = PROFIBUS-DP ( hanya CPU 215)

Memory Card Slot untuk memory card. Memory card menyimpan isi program pada saat power
lost tanpa memerlukan battery.

PPI Connection Tool Programming, text display, atau CPU yang lain terkoneksi disini, kecuali
untuk CPU 210 yang diprogram pada sistem programming (PDS210) dan di
transfer ke CPU via memory submodule.

Untuk tipe CPU yang Higher end berisi dua port dan memperbolehkan
terkoneksi ke tool programming dan text display dalam waktu bersamaan.

MPSL Intermediate
Maintenance Personel Skill Level Page 8 SIMATIC® Manager
Bentuk • Modular small control system untuk performa dengan range paling rendah
• Performance-graded range dari CPU
• Ekstensif seleksi modul .
• Dapat di expand sampai dengan 32 modules
• Bus Backplane terintegrasi dalam modul
• Kemampuan jaringan - Multipoint interface (MPI),
- PROFIBUS atau
- Industrial Ethernet.
• Koneksi terpusat PG/PC dapat mengakses seluruh modul.
• Tidak ada pembatasan slot
• Konfigurasi dan setting parameter dengan bantuan "HWConfig" tool.

MPSL Intermediate
Maintenance Personel Skill Level Page 9 SIMATIC® Manager
Signal Modules • Digital input modules: 24 VDC, 120/230 VAC
(SM) • Digital output modules: 24 VDC, Relay
• Analog input modules: Voltage, current,
resistance, thermocouple
• Analog output modules: Voltage, current

Interface Modules IM360/IM361 dan IM365 memungkinkan membuat konfigurasi multi-tier.


(IM) Modul interface menge-loop bus dari satu tier ke berikutnya.

Dummy Modules DM 370 dummy module cadangan slot untuk modul parameter sinyal yang belum
(DM) ditetapkan. Sebuah modul dummy juga dapat digunakan, misalnya, untuk cadangan
slot untuk instalasi dari modul Interface di kemudian hari.

Function Modules Melakukan "special functions":


(FM) - Counting
- Positioning
- Closed-loop control.

Communication Menyediakan fasilitas jaringan berikut:


Processors (CP) - Point-to-Point connections
- PROFIBUS
- Industrial Ethernet.

Accessories Bus connectors dan front connectors

MPSL Intermediate
Maintenance Personel Skill Level Page 10 SIMATIC® Manager
Mode Selector MRES = Fungsi Memory reset (Module Reset)
STOP = Stop mode, program tidak di eksekusi.
RUN = Eksekusi Program, PG hanya memungkinkan akses membaca
saja.
RUN-P = Eksekusi Program, PG dapat mengakses baca dan tulis .
Status Indicators SF = Group error; internal CPU fault atau fault dalam module dengan
diagnosa
(LEDs) capability.
BATF = Battery fault; battery empty atau non-existent.
DC5V = Indikator tegangan 5 VDC.
FRCE = FORCE; mengindikasikan input atau output yang di-forced.
RUN = Berkedip saat CPU sedang starting up, kemudian diam pada Run
mode.
STOP = Menyala diam saat Stop mode.
Berkedip pelan saat permintaan mereset memori,
Berkedip cepat saat reset memori sedang berlangsung,
Berkedip pelan saat reset memori diperlukan karena memori card
telah dimasukkan.

Memory Card Sebuah slot yg menyediakan memory card. Memory card menyimpan isi program
saat tidak ada power tanpa memerlukan battery.

Battery Compartment Ada tempat untuk baterai lithium di bawah penutup. The battery provides backup
power to save the contents of the RAM in the event of a power outage.

MPI Connection Connection for a programming device or other device with an MPI interface.

DP Interface Interface for direct connection of distributed I/Os to the CPU.

MPSL Intermediate
Maintenance Personel Skill Level Page 11 SIMATIC® Manager
Bentuk • PLC yang powerful untuk performance menengah ke atas
• Performance-graded range dari CPUs
• Ekstensif seleksi modul .
• Dapat di expand sampai dengan 300 modules
• Bus Backplane terintegrasi dalam modul
• Kemampuan jaringan - Multipoint interface (MPI),
- PROFIBUS atau
- Industrial Ethernet
• Koneksi terpusat PG/PC dapat mengakses seluruh modul.
• Tidak ada pembatasan slot
• Konfigurasi dan setting parameter menggunakan bantuan "HWConfig" tool
• Multicomputing (sampai 4 CPU dapat digunakan di dalam central rack )

MPSL Intermediate
Maintenance Personel Skill Level Page 12 SIMATIC® Manager
Signal Modules (SM) • Digital input modules: 24 VDC, 120/230 VAC
• Digital output modules: 24 VDC,Relay
• Analog input modules: Voltage, current, resistance, thermocouple
• Analog output modules: Voltage, current.

Interface Modules (IM) IM460, IM461, IM463, IM467 interface modules menyediakan koneksi diantara b
eberapa rack :
• UR1 (Universal Rack) sampai dengan 18 modules
• UR2 (Universal Rack) sampai dengan 9 modules
• ER1 (Expansion Rack) sampai dengan 18 modules
• ER2 (Expansion Rack) sampai dengan 9 modules.

Function Modules (FM) Perform "special functions":


• Counting
• Positioning
• Closed-loop control.

Communication Processors (CP)


Menyediakan fasilitas jaringan seperti berikut :
• Point-to-Point connections
• PROFIBUS
• Industrial Ethernet.

MPSL Intermediate
Maintenance Personel Skill Level Page 13 SIMATIC® Manager
Fault LEDs Slot LED pada CPU mengindikasikan status dan fault, internal maupun ekternal
untuk Memory Cards Dengan S7-400™ CPUs kita dapat, tergantung pada kebutuhan Anda, sisipkan
RAM atau flash EPROM cards as external load memory :
• RAM cards ada beberapaa kapasitas yaitu: 64KByte, 256KByte, 1MByte,
2Mbyte . Batere CPU membackup isi programs.
• Flash EPROM cards ada beberapa kapasitas: 64KByte, 256KByte, 1MByte,
2MByte, 4MByte, 8MByte, 16MByte. Backup isi program terintregrasi pada
EEPROMs.

Mode Selector MRES = Fungsi Reset Memori(Module RESet)


STOP = STOP mode, artinya, tidak ada eksekusi program dan output di-
disable ("OD" mode = Output Disabled).
RUN = Eksekusi Program, hanya dapat akses baca dari PG.
RUN-P = Eksekusi Program, dapat akses read/write dari PG.

MPI / DP Interface MPI / DP interface (parameter-assignable in HW-Config) for


• membangun koneksi online ke perangkat pemrograman
• koneksi kedistributed peripherals (DP)
• pertukaran data dengan stasiun lainnya(S7 Communication)

DP Interface Untuk koneksi distributed peripherals (DP, hanya untuk CPUs dgn 2 interfaces)

EXT-BATT Tambahan external soket untuk 5 VDC sampai15 VDC untuk membackup RAM
jika power supply diganti.

MPSL Intermediate
Maintenance Personel Skill Level Page 14 SIMATIC® Manager
Field PG adalah standart perangkat pemrograman dalam industri. Field PG sangat
powerful dan mudah digunakan, terutama untuk maintenance dan service. Tool
ini juga sesuai untuk programming dan konfigurasi- alat yang ideal untuk
aplikasi .
Bentuk:
• Dimensi seperti format Notebook
• Operasi batere 2 jam
• Compatible AT
• TFT color display
• Dilengkapi dengan semua port antarmuka yang diperlukan SIMATIC

Power PG Sebuah perangkat portabel pemrograman, ideal untuk semua aplikasi dalam
sebuah proyek otomatisasi. Ini juga merupakan, standar PC industri yang
sangat kuat

Bentuk:
• Kinerja sistem tingkat tinggi
• Fasilitas ekpansi yang lengkap
• TFT color display
• Design sangat kasar
• Dilengkapi dengan semua port antarmuka yang diperlukan SIMATIC

Catatan Tool pemrograman menggunakan Hand-held juga ada untuk memprogram


S7-200™ dalam STL (Statement List). Perangkat Pemrogramana ini adalah
PG702 = kira-kira 230 grams, 144 x 72 x 27mm, 2 lines x 20 character LC
display.

.
MPSL Intermediate
Maintenance Personel Skill Level Page 15 SIMATIC® Manager
Requirements SIMATIC PG menyediakan keperluan yang optimal untuk menggunakan
software STEP 7.
Kita juga dapat menggunakan PC yang telah memenuhi persyaratan list diatas.
Agar kita dapat online ke PLC menggunakan PC, PC harus dilengkapi dengan
salah satu interface yang terdapat di list diatas.

Jika program di load ke memory card, PC harus juga adilengkapi dengan


interface programming .

MPSL Intermediate
Maintenance Personel Skill Level Page 16 SIMATIC® Manager
Instalasi 1. Actifkan "Setup.exe" dengan memilih "Add/Remove Programs" pada
"Winxx- >Control Panel".
2. Pilih “Options“.
3. Pilih “Language“.
4. Masukkan autorisasi disk jika diminta.
5. Lakukan Re-boot jika diminta.

Proteksi Software Software STEP 7 diproteksi untuk di-copy dan hanya digunakan pada satu
perangkat pemrograman.
Saat kita sudah menginstalasi software, kita tidak bisa menggunakannya
sampai kita telah menstransfer autorisasinya ke dalam hardisk dari disket
autorisasi.

Catatan • Yakinkan sudah membaca README.TXT file pada autorisasi disket. Jika
Anda tidak mengamati petunjuk ini, Anda berisiko kehilangan otorisasi Anda.
• Seperti STEP 7 V5.0, Paket dasar STEP 7 dapat juga dioperasikan tanpa
autorisasi sampai autorisasi bari diterima. Oleh karena itu jangan menggunakan
opsi paket, seperti S7 Graph, jika dia sudah diinstall.
• Seperti STEP 7 V4.0, software hanya ada pada CD-ROM
• Software Service Packs dapat juga di-download dari Internet.

Service Packs Free-of-Charge


Software Service Packs dapat di-download dari Internet via
http://www.ad.siemens.de/simatic-cs.

MPSL Intermediate
Maintenance Personel Skill Level Page 17 SIMATIC® Manager
Pengenalan Alat utama pada STEP 7 adalah SIMATIC® Manager. Ada 2 cara untuk
mengaktifkannya:

1. melalui Task bar -> Start -> SIMATIC® -> SIMATIC® Manager

2. melalui ikon "SIMATIC® Manager".

MPSL Intermediate
Maintenance Personel Skill Level Page 18 SIMATIC® Manager
SIMATIC® Manager SIMATIC® Manager me-manage STEP 7 proyek. Ini adalah program utama dan
juga muncul pada desktop WINDOWS.

Notes "STEP 7 - Readme" memberikan informasi rinci tentang versi, prosedur


instalasi, dll
LAD, STL, FBD Alat untuk menulis pada program user STEP 7 yaitu "Ladder Diagram",
"Statement List„ atau "Function Block Diagram" program bahasa.

Memory Card Anda dapat menyimpan program-program Anda pada kartu EPROM
Parameter menggunakan programming device atau external prommer.
Assignment. Driver yang berbeda diperlukan, tergantung pada aplikasi.

Configuring Konfigurasi jaringan ini dibahas dalam bab tentang "Komunikasi".


Networks

Setting the PG-PC Alat ini digunakan untuk menetapkan alamat node lokal, kecepatan transmisi
Interface dan alamat node tertinggi di jaringan MPI.

PID Control Paket software basic STEP 7 juga termasuk block untuk menyelesaikan
Parameter masalah kontrol PID (closed-loop) .Pilih "PID Control Parameter
Assignment Assignment" untuk memulai program untuk menetapkan parameter pada blok
kontrol closed-loop .

Converting S5 Files Program STEP5 dapat dikonversi menjadi STEP 7 programs dengan bantuan
S5/S7 converter.

Configure SIMATIC Opsi ini menyediakan fasilitas untuk mengkonfigurasi sistem multi-user.
Workspace

Converting TI Files Program SIMATIC TI dapat dikonversi menjadi vSTEP 7 program dengan
bantuan dari TI/S7 converter.

MPSL Intermediate
Maintenance Personel Skill Level Page 19 SIMATIC® Manager
Isi H
al.

Tujuan .......................................................................................................................................................... 2
Dari Proses ke Proyek ................................................................................................................................ 3
Strutur Proyek STEP 7 ................................................................................................................................ 4
Memulai SIMATIC® Manager ....................................................................................................................... 5
Menu SIMATIC® Manager dan Toolbars …....………................................................................................. 6
Toolbar pada SIMATIC® Manager .............................................................................................................. 7
Membuat Projek S7 …................................................................................................................................. 8
Menyisipkan sebuah Blok Program pada S7............................................................................................... 9
Tampilan Offline / Online pada SIMATIC® Manager ...................................................................................10
Standard Library .......………........…….....................................................................................................11
Latihan : Membuat sebuah Projek ............................................................................................................12
Latihan : Menyisipkan sebuah Program S7 ...............................................................................................13
Latihan : Mengkopi sebuah Blok dari Standard Library.............................................................................14

MPSL Intermediate
Maintenance Personel Skill Level Page 20 SIMATIC® Manager
Proses Saat kita ingin melihat lebih dekat sebuah proses yang ingin kita otomasikan,
kita menemukan beberapa bagian seksi –seksi kecil dan sub-proses yang
mana semuanya saling berkaitan dan saling tergantung dengan yang lainnya.
Untuk memudahkan proses otomasi, secara keseluruhan proses dipecah
menjadi sub-proses.

Hardware dan Masing-masing sub-mendefinisikan hardware tertentu dan perangkat lunak yang
dibutuhkan oleh sistem otomasi ;
Software :
• Hardware:
- Nomor dan tipe inputs dan outputs
- Nomor dan tipe module
- Nomor racks
- Kapasitas dan tipe CPU
- Sistem HMI
- Sistem jaringan
• Software:
- Struktur Program
- Data management untuk proses otomasi
- Data konfigurasi
- Data komunikasi
- Dokumentasi program dan project.

Proyek pada SIMATIC® S7 semua hardware dan software di proses otomasi di manage
oleh sebuah proyek.
Sebuah proyek terdiri dari hardware (+ konfigurasi), network
(+ konfigurasi), seluruh programs, dan data managemen sebagai solusi
automation.

MPSL Intermediate
Maintenance Personel Skill Level Page 21 SIMATIC® Manager
Pengantar The SIMATIC® Manager adalah antarmuka grafis untuk mengubah online/offline
objek S7 (projects, user program files, blocks, stasiun hardware dan tools).
Dengan SIMATIC® Manager kita dapat:
• manage projects dan libraries,
• mengaktifkan STEP 7 tools,
• mengakses PLC online,
• mengubah memory cards.

Memulai Ada "SIMATIC® Manager" icon di Windows desktop dan


SIMATIC® Manager "SIMATIC® Manager" program item dibawah SIMATIC® pada Start menu.
Kita dapat juga mengaktifkan program dengan cara double-click icon
atau menggunakan Start menu

START -> SIMATIC® ->

Catatan Jika membutuhkan bantuan pada setiap window, kita dapat menekan F1
sebagai kunci bantuan secara online.

MPSL Intermediate
Maintenance Personel Skill Level Page 22 SIMATIC® Manager
Judul Bar Judul Bar berisi judul jendela dan tombol-tombol untuk mengontrol jendela.
Menu Bar Berisi semua menu yang tersedia untuk jendela aktif.

Toolbar Berisi tugas yang paling sering digunakan sebagai simbol. Simbol-simbol yang
cukup jelas.

Status Bar Menampilkan status saat ini dan informasi lebih lanjut.

Taskbar Taskbar berisi semua aplikasi yang terbuka dan jendela sebagai tombol. Anda
dapat memposisikan taskbar di kedua sisi layar dengan menggunakan tombol
kiri mouse dan menyeretnya ke posisi baru.

MPSL Intermediate
Maintenance Personel Skill Level Page 23 SIMATIC® Manager
MPSL Intermediate
Maintenance Personel Skill Level Page 24 SIMATIC® Manager
Membuat Project Sorot menu options File -> New atau symbol in the toolbar untuk
membuka "New" dialog box untuk membuat project baru atau library baru.
Masukkan nama proyek di kotak "Nama" dan klik "OK" untuk konfirmasi.

catatan 1. "Storage location (path)" menampilkan lokasi yang telah di set sebelumnya
pada SIMATIC® Manager Options -> Customize.

MPSL Intermediate
Maintenance Personel Skill Level Page 25 SIMATIC® Manager
Menyisipkan Program Select Insert -> Program -> S7 Program menu untuk menyisipkan program baru
pada proyek ini.
Ketika kita memasukkan sebuah objek, sistem secara otomatis memberi nama
yang relevan, seperti “S7 Program(1)".
Kita kemudian dapat mengubah nama ini sesuai yang kita sukai.

catatan Kita menggunakan metode yang dijelaskan di atas untuk membuat program
hardware-independen.

MPSL Intermediate
Maintenance Personel Skill Level Page 26 SIMATIC® Manager
Tampilan Offline Pada jendela proyek dari SIMATIC® Manager, tampilan offline struktur program
di simpan pada hardisk dari programming device.
"S7 Program" folder berisi "Sources" dan "Blocks" objects.
"Blocks" folder berisi sistem data yang dibuat dengan HWConfig tool dan Block
yang dibuat oleh LAD/STL/FBD Editor.

Tampilan Online tampilan online diatas menunjukan struktur project offline di kiri window dan
kanan window itu menunjukan block yang disimpan di dalam CPU.
Pada, " S7 Program " terlihat dalam tampilan online hanya berisi "Blok" folder
yang berisi berikut:
• System data blocks (SDB)
• User blocks (OB, FC, FB)
• System blocks (SFC, SFB).

Merubah tampilan Mengubah antara tampilan offline dan online :


• melalui View -> Offline atau View -> Online menu items
atau
• dengan simbol yang sesuai pada toolbar :

Online

Offline

Catatan Kita dapat mengatur tampilan "ONLINE" dan "OFFLINE" di samping satu sama
lain atau di bawah satu sama lain menggunakan Window -> pilih option di menu
bar.

MPSL Intermediate
Maintenance Personel Skill Level Page 27 SIMATIC® Manager
Standard STEP 7 berisi Standard Library, yang disimpan pada STEP 7 Software
Library folder yaitu di C:\Siemens\Step7\S7libs\stlib30 setelah STEP 7 diinstall. Kita
dapat mengakses standard blocks ini dari SIMATIC® Manager dengan cara
"Open->Libraries" menu option.

Blok FCs (functions) berfungsi untuk komunikasi antara CPU dan distributed I/O via
Komunikasi communication processors dengan S7-300™.

Organisasi Blok Organization blocks (OBs).

Konvert Blok S5-S7 Blocks untuk mengkonvert STEP 5 programs ke S7.

Konvert Blok TI-S7 Umumnya digunakan untuk fungsi standar seperti scaling nilai analog

Fungsi Blok IEC Blok untuk fungsi IEC (IEC: International Electrotechnical Commission),
seperti untuk waktu pemrosesan dan tanggal, untuk operasi perbandingan,
untuk pengolahan string dan untuk memilih maksimum dan minimum.

Kontrol Blok PID Fungsi Blok (FBs) untuk PID closed-loop controls.

Sistem Fungsi System functions (SFCs) dan System function blocks (SFBs).
Blok

MPSL Intermediate
Maintenance Personel Skill Level Page 28 SIMATIC® Manager
Tugas Hapus proyek lama dan buat proyek baru dengan nama „My_Project“ jika ada

Apa yang Harus Dilakukan 1. Start SIMATIC® Manager


2. Hapus proyek lama "My_Project" (if it exists):
File -> Delete -> User projects -> select "My_Project" in the list ->
confirm
3. buat proyek baru "My_Project"
File -> New... -> User projects -> enter "My_Project" in the Name box
-> confirm

MPSL Intermediate
Maintenance Personel Skill Level Page 29 SIMATIC® Manager
Tugas Menyisipkan S7 Program dengan nama "My_Program" ke proyek "My_Project"
.

Yang dikerjakan 1. sisipkan S7 Program


Select the project called "My_Project" -> Insert -> Program -> S7Program
2. rubah default nama S7 Program "S7 Program (1)" ke "My_Program":
Click S7 Program 2x (bukan double-click!) -> tulis "My_Program"
pada program lama

Hasil Kita telah membuat program "My_Program" pada proyek "My_Project". OB1
akan terinsert secara otomatis

Catatan Sebuah Program S7 berisi objek berikut :


• Blocks: dimana logika disimpan (OBs, FCs, FBs dan DBs) yang dapat di
transfer ke CPU
• Sources: untuk menyimpan source programs yang dibuat dengan text
editors,
contoh, untuk STL, S7-SCL atau S7-HiGraph
• Symbols: untuk deklarasi (nama) pada alamat global S7 seperti inputs,
outputs, bit memories, timers, counters

MPSL Intermediate
Maintenance Personel Skill Level Page 30 SIMATIC® Manager
Tugas Mengkopi FC105 blok dari STEP7 "Standard Library“ ke Blok folder dari S7
Program "My_Program“ di dalam project "My_Project".

Yang dikerjakan 1. Buka"Standard Library" pada SIMATIC® Manager:


File > Open... -> sorot "Libraries" tab -> pilih "Standard Library" pada list -
> confirm
2. Pada project "Standard Library" buka Blocks folder dari S7 Program
"TI- S7-Converting Blocks"
3. Tampilkan proyek "My_Project" dan "Standard Library" bersamaan di dua
window pada SIMATIC® Manager
Window > Arrange > Horizontally
4. Gunakan drag & drop, copy FC 105 block dari "Standard Library" ke
folder program "My_Program"
5. Tutup library.

Hasil Block FC 105 disimpan pada Blocks folder dari S7 Program "My_Program" di
samping OB masih kosong 1.

Catatan Libraries digunakan untuk menyimpan blok-blok yang berisi fungsi standar. Kita
dapat menyalin dari Library ke dalam setiap proyek yang kita inginkan., Jika
nama (nomor) dari blok yang kita salin sudah ada, kita dapat mengubah nama
blok library (nomor) saat kita memasukkan blok ke dalam folder program kita.

MPSL Intermediate
Maintenance Personel Skill Level Page 31 SIMATIC® Manager

Anda mungkin juga menyukai