Pad: (Pad Footing PF17) 2600mm long x 1000mm wide, 600mm deep OK (0.99)
f'c = 25MPa, Bearing = 215kPa < 250kPa OK (0.86)
Reinf't: N20-200 cts (BLL), N20-200 cts (BUL) (BLL bars in L dir.) , 60mm cover
Column: 300mm long x 600mm wide, P* = 761kN
Geometry
Eccentricity (EccL) = 0 mm
Eccentricity (EccW) = 0 mm
Design capacities
Bending - Cl 8.1 & Cl 15.4.2 alpha (α2 = 1.00-0.003*f'c) = 0.850 (0.67 ≤ α2 ≤ 0.85) Eq 8.1.3(1)
gamma (γ = 1.05-0.007*f'c) = 0.850 (0.67 ≤ γ ≤ 0.85) Eq 8.1.3(2)
ø = 1.19-13*kuo/12 = 0.800 (0.60 ≤ ø ≤ 0.80) Table 2.2.2 for N Class
Moment (ML*) = 193.6 kNm/m øMuo.L = 321.4 kNm/m OK (0.60)
Moment (MW*) = 5.9 kNm/m øMuo.W = 308.8 kNm/m OK (0.02)
Plain concrete ø = 0.6 Table 2.2.2
øMuo.ur = 90.8 kNm/m
One-way shear - Cl 8.2 & Cl 15.4.3 fcv = f'c¹′³ ≤ 4MPa = 2.92 MPa
1-way shear (VL*) = 181.5 kN/m øVu.L = 183.4 kN/m OK (0.99) - Refer Cl 8.2.5(ii)
1-way shear (VW*) = 0.0 kN/m øVu.W = 182.1 kN/m OK (0.00)
β1.L = 1.177 β1.W = 1.199 øVu.ur = 144.7 kN/m
Reinforced Unreinforced
Moment L OK (0.60) No Good (2.13)
Moment W OK (0.02) OK (0.06)
Shear L OK (0.99) No Good (1.25)
Shear W OK (0.00) OK (0.00)
Punching OK (0.21) OK (0.38)
Bearing OK (0.86) OK (0.86)
Column area:
Column area calculated at the level of the bottom
tensile steel for reduction in punching shear.
Unreinforced:
For unreinforced, the designer should
consider providing Ast for M*.
Reinf't notation:
BUL - Bottom upper layer, BLL - Bottom lower layer
Ast.min - Cl 16.3.1
Ast.min = 0.19*(D/ds)²*f'ct.f/fsy*b*ds
f'ct.f = 0.6*√f'c (Cl 3.1.1.3)
'.ur' values:
*.ur are values for unreinforced section.
Refer to AS 3600, Cl 12.1.1.1 & Section 15
øMuo.ur = ø*f'ct.f*Z (ø=0.6)
øVu.ur = ø*0.15*b*(D-50)*f'c¹′³ (ø=0.6)
øVp.ur = does not allow for moment transfer
Shear β values:
β1.L = 1.1*(1.6-do/1000) ≥ 0.8
Shear perimeter:
dom taken as the min. depth of tensile steel.