A. INPUT DATA
Footing Name:
NOTE: All inputs of axial loads must be positive (compression) with their respective positive/negative moments about y axis
In determining the reinforcement, always consider the left and right earthquake load directions.
Loadings:
db_footing ≔ 16 mm column_steel_percent ≔ 2%
soil_backfill_unit_weight ≔ 18 kN/m^3
reinforced_concrete_unit_weight ≔ 25 kN/m^3
Strength Parameters:
Strap Beam Parameter:
db_strap ≔ 20 mm
db_sk ≔ 10 mm
footing1_width ≔ 1 m
footing1_length ≔ .8 m
footing2_width ≔ 1.8 m
footing2_length ≔ 1.8 m
q_footing1 = 57.5
q_footing2 = 62.04
q_footing = 61.14
qnet = 96.3
Footing_Soil_Pressure = “Safe”
ex_load = 3.81
ex_footing = 3.81
Footing_Dimension = “Safe”
P1U = 58.8 kN
M1UY = 0 kN-m
P2U = 251.6 kN
M2UY = 0 kN-m
qu = 76.83 kPa
One_Way_Shear = “Safe”
for footing
PF_required_strength = 251.6 kN
PF_design_strength = 2053.64 kN
for column
PC_required_strength = 251.6 kN
PC_design_strength = 1026.82 kN
Use N1x ≔ 5
N1y ≔ 5
Use N2x ≔ 7
N2y ≔ 7
Percent_Ductility_strap = 100
Use NSx ≔ 5
Length_Development_column_rebar_compression = “Safe”
Length_Development_column_rebar_tension = “Safe”
Length_Development_strap_beam_rebar_tension = “Safe”
Thickness = “Safe”
space_column1_long = 208.5 mm
Spacing_column1_long = “Safe”
space_column1_traverse = 158.5 mm
Spacing_column1_traverse = “Safe”
space_column2_long = 272.33 mm
Spacing_column2_long = “Safe”
space_column2_traverse = 272.33 mm
Spacing_column2_traverse = “Safe”
spacing_strap_beam_rebar = 35 mm
Spacing_strap_beam_rebar = “Safe”
Use h ≔ 450 mm