AMNC Ver.

5 Additional Feature Instruction Manual

Dr.ABE_Bend

Feasibility Report Function

Version 1

Amada Co. Ltd.

1
Table of contents

Outline............................................................................................................ 3
Explanation about operation........................................................................ 4
Run the "Feasibility Report" screen. ............................................................................4
Explanation about the [Feasibility Report] screen ......................................................6
- [Detail of Failures / Warnings] screen..............................................................................................6
Message of Feasibility Report ..................................................................... 8

2
Outline

This document describes the instruction manual about the additional feature [Feasibility
Report] to the AMNC Ver.5.0.0000.0058 Patch 4.

This feature is the feature for displaying [The reason for the impossibility of bend] that is
created by DR.ABE_BEND, so unless installing the modules that are provided by DR.ABE_BEND,
it doesn't work properly. Please perform the installation / the version upgrade in advance.
[The reason for the impossibility of bend] will be saved in SDD along with the result of [Auto
Step Generation] of DR.ABE_BEND.
Please perform the setting so that [The reason for the impossibility of bend] will be saved by the
user parameter on DR.ABE_BEND side.
In addition, if DR.ABE_BEND and AMNC have the same machine name, and if overwriting the
bend data by AMNC, [The reason for the impossibility of bend] will not be saved.
We recommend giving separate name for each machine name of DR.ABE_BEND and AMNC.

3
Explanation about operation

Operation will be explained by setting machine name of AMNC as "BEND0" and by setting
machine name of data where [Auto Step Generation] is performed by DR.ABE_BEND as
"BEND0-CA".
When your using machine names are different, please replace the above names with yours.

Run the "Feasibility Report" screen.

1) Select a work of the machine name "BEND0-CA" in the "LIST" screen, and press the "Enter"
button.

4
2) If you'd like to see [Message of feasibility report], please press the [FEASIBILITY REPORT]
button in the [TOOLS PROG] screen.

3) The [Detail Status] screen will run.

5
Explanation about the [Feasibility Report] screen

Below are the explanations about the [Detail Status] screen.


Please press the "Close" button after confirming contents.

- [Detail of Failures / Warnings] screen

1 5

- Parts / Status Field (Screen 1)


The name of the selected part and results of Automatic Step Generation are displayed.

- Message Field (Screen 2)


Detailed information on failures and warnings is displayed together with instructions on
how to respond to them.

- Bending Sequence Field (Screen 3)


The bending sequence data created in Automatic Step Generation is displayed. Each
parenthesized group represents a single piece of step data, with the first number being the
bend line number and the last number the face number. Bend line numbers and face
numbers appear in red and blue respectively in the Figure Display Area.

6
- [Drawing Bend Information] Button (Screen 4)
Displays the information of drawing bendline. It displays values of [Material Type],
[Thickness], [Inner-R of each bendline], [Bend Deduction], [Angle], [Front/Back] and
[V-width].

- Figure Display Area (Screen 5)


Shows the plane view, bend line numbers and face numbers for the part.
(Note) The numbers attached to the bend lines do Not represent the bending sequence.

- Plane View [Show Bend Line ID] Check Box


You can display and hide the bend line numbers in the plane view by checking and
unchecking the box.

- Plane View [Show Bend Face ID] Check Box


You can display and hide the face numbers in the plane view by checking and
unchecking the box.

-[Restore the Zoom] Button


Restore the zoom to the original size in the plane view in the Figure Display Area.

7
Message of Feasibility Report

Please refer to [3.4.2 Message list of Generated Results] in [DR.ABE_BEND Instruction Manual]
for the list of contents in the displayed messages.
As for other than the following message, the same contents as the contents, which are output by
the error details indication feature of DR.ABE_BEND, will be displayed.

Message of Failure (Initial Processing)

No. Outline of message Detailed message Note


AMNC ABE Environment/ (Contents) Please confirm by the error
Setting Error There were problems in the setup or the details indication function of the
parameter of the Dr.ABE_Bend Dr.ABE_Bend.
automatic,
and it failed in the formation of the
automatic bend process.
(Solution)
Please confirm by the error
details indication function of the
Dr.ABE_Bend.

Anda mungkin juga menyukai