Date:

8/20/2018

Project 0
Project 0 8/20/2018

Project 0 / Table of contents

Table of contents
Project 0
Site 1
Building 2
first
Room 2
Room summary....................................................................................................................................................................................... 3
Luminaire layout plan.............................................................................................................................................................................. 4
Calculation surface 7 / UGR....................................................................................................................................................................7

Page 2
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Room summary

Room 2

Clearance height: 2.800 m, Reflection factors: Ceiling 70.0%, Walls 23.8%, Floor 20.1%, Light loss factor: 0.80

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane 2 Perpendicular illuminance (adaptive) [lx] 473 (≥ 500) 34.2 843 0.07 0.04
Height: 0.800 m, Wall zone: 0.000 m

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

13 Fagerhults Belysning AB - 57755 Discovery Evo 4K 1898 14.0 135.6

60 ONOK LIGHTING - - Focus 80 20W 4K 60º Clear CRI95 2695 22.5 119.8

10 ONOK LIGHTING - LINE C_29W_4000K LINE C_29W_4000K 3382 31.6 107.2

Total via all luminaires 220194 1848.0 119.2

Lighting power density: 5.08 W/m² = 1.08 W/m²/100 lx (Floor area of room 363.64 m²)

The energy consumption quantities refer to the lights planned for the room without taking into account light scenes and their dimming levels.
Consumption: 5100 kWh/a of maximum 12750 kWh/a
The results were calculated without consideration of objects and furniture. No results were determined on their surfaces.

Page 3
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Luminaire layout plan

Room 2

ONOK LIGHTING LINE C_29W_4000K LINE C_29W_4000K

No. X [m] Y [m] Mounting height [m]


1 23.407 10.967 2.500
2 23.407 12.756 2.500
3 21.699 10.967 2.500
4 21.699 12.756 2.500
5 25.179 10.939 2.500
6 26.792 10.928 2.500
7 28.406 10.918 2.500
8 25.191 12.743 2.500
9 26.804 12.732 2.500
10 28.418 12.722 2.500

Fagerhults Belysning AB 57755 Discovery Evo 4K

No. X [m] Y [m] Mounting height [m]


11 27.836 9.365 2.800
12 25.000 9.375 2.800
13 22.165 9.384 2.800
14 27.431 4.186 2.800
15 24.595 4.195 2.800
16 21.760 4.205 2.800
17 28.164 2.461 2.800
18 28.164 0.817 2.800
19 25.420 3.072 2.800
20 25.406 1.586 2.800

Page 4
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Luminaire layout plan

No. X [m] Y [m] Mounting height [m]


21 25.406 0.485 2.800
22 23.363 2.788 2.800
23 23.381 0.497 2.800

ONOK LIGHTING - Focus 80 20W 4K 60º Clear CRI95

No. X [m] Y [m] Mounting height [m]


24 2.105 0.638 2.800
25 2.105 1.993 2.800
26 2.105 3.349 2.800
27 2.105 4.704 2.800
28 2.105 6.060 2.800
29 2.105 7.415 2.800
30 2.105 8.770 2.800
31 2.105 10.126 2.800
32 2.105 11.481 2.800
33 2.105 12.837 2.800
34 5.324 0.666 2.800
35 5.324 2.021 2.800
36 5.324 3.377 2.800
37 5.324 4.732 2.800
38 5.324 6.087 2.800
39 5.324 7.443 2.800
40 5.324 8.798 2.800
41 5.324 10.154 2.800
42 5.324 11.509 2.800
43 5.324 12.865 2.800
44 8.519 0.864 2.800
45 8.519 2.219 2.800
46 8.519 3.574 2.800
47 8.519 4.930 2.800
48 8.519 6.285 2.800
49 8.519 7.641 2.800
50 8.519 8.996 2.800
51 8.519 10.352 2.800
52 8.519 11.707 2.800
53 8.519 13.063 2.800
54 12.083 0.864 2.800
55 12.083 2.219 2.800
56 12.083 3.574 2.800
57 12.083 4.930 2.800
58 12.083 6.285 2.800
59 12.083 7.641 2.800
60 12.083 8.996 2.800
61 12.083 10.352 2.800
62 12.083 11.707 2.800
63 12.083 13.063 2.800
64 15.093 0.728 2.800
65 15.093 2.084 2.800
66 15.093 3.439 2.800
67 15.093 4.794 2.800
68 15.093 6.150 2.800

Page 5
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Luminaire layout plan

No. X [m] Y [m] Mounting height [m]


69 15.093 7.505 2.800
70 15.093 8.861 2.800
71 15.093 10.216 2.800
72 15.093 11.572 2.800
73 15.093 12.927 2.800
74 17.964 0.856 2.800
75 17.964 2.211 2.800
76 17.964 3.567 2.800
77 17.964 4.922 2.800
78 17.964 6.277 2.800
79 17.964 7.633 2.800
80 17.964 8.988 2.800
81 17.964 10.344 2.800
82 17.964 11.699 2.800
83 17.964 13.055 2.800

Page 6
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Calculation surface 7 / UGR

Calculation surface 7 / UGR

Calculation surface 7: UGR (Grid)


Light scene: Light scene 1
Strongest glare at: 330°, Max: >30, Threshold value: ≤19.0, Viewing sector: 0° - 360°, Step width: 15°, Height: 1.411 m

Page 7
Project 0 8/20/2018

Site 1 / Building 2 / first / Room 2 / Calculation surface 7 / UGR

16
16
13 16
13 16
13 16
13 16
36 13 16
39 13 16
39 13 16
40 13 16
40 13 16
38 13 16
40 13 16
32 13
41 13
30
42
27
40

16
16
13 16
13 16
13 16
13 16
37 13 16
39 13 16
36 13 16
40 13 16
36 13 16
36 13 16
40 13 16
33 13
41 13
28
41
27
40

16
16
13 16
13 16
13 16
13 16
35 13 16
38 13 16
38 13 16
39 13 16
38 13 16
36 13 16
39 13 16
31 13
40 13
29
41
26
38

16
16
13 16
13 16
13 16
13 16
36 13 16
38 13 16
36 13 16
39 13 16
36 13 16
35 13 16
39 13 16
32 13
40 13
27
40
25
40

16
16
13 16
13 16
13 16
35 13 16
38 13
38 13 16
16
38 13 16
36 13 16
39 13 16
13
40 13
29
42
25
37

16
16
13 16
13 16
13 16
13 16
36 13 16
38 13 16
36 13 16
39 13 16
37 13 16
35 13 16
39 13 16
32 13
40 13
27
40
24
41

16
16
13 16
13 16
13 16
13 16
35 13 16
38 13 16
38 13 16
39 13 16
38 13 16
36 13 16
40 13 16
31 13
41 13
30
42
24
36

16
16
13 16
13 16
13 16
13 16
36 13 16
38 13 16
37 13 16
38 13 16
37 13 16
35 13 16
39 13 16
32 13
41 13
28
40
23
42

16
16
13 16
13 16
13 16
13 16
36 13 16
40 13 16
38 13 16
40 13 16
38 13 16
37 13 16
41 13 16
32 13
42 13
31
44
23
36

The results were calculated without consideration of objects and furniture. No results were determined on their surfaces.