PRODUCT DATA SHEET

Bentley Hevacomp Simulator V8i


Intuitive Interface to Industry Standard EnergyPlus™ Energy Simulation

Bentley Hevacomp Simulator V8i provides a quick and easy way to perform building energy
analysis using Dynamic Simulator with EnergyPlus.

Provides 3D Modeler in Design Database Summer overheating frequency can be simulated using
Bentley Hevacomp Simulator V8i offers consultant and CIBSE summer design weather data, and hours of
design contractors, building services design and MEP overheating can be obtained from cumulative frequency
professionals a tool that is easy and quick to use for results to check against U.K. Part L code requirements.
building energy analysis using Dynamic Simulator with Natural infiltration can be examined by defining flowpaths
Air Flow Visualization and opening windows. This enables complex natural and
EnergyPlus. Using the 3D modeler in the design database,
projects can be fully simulated in EnergyPlus. EnergyPlus is mixed-mode ventilation systems to be examined, including
fast emerging as the global standard for dynamic simulation. controlled opening of windows.
It is used for all building load and energy calculations, plant
energy calculations and passive design simulations. Includes Database of over 7,000 Locations
Hevacomp provides an extensive Meteonorm weather
Increasingly, engineers are required to carry out more database of over 7,000 locations worldwide for annual
complex analysis, such as over-heating frequency, mixed energy simulation. A detailed profiling and scheduling
mode ventilation and CFD analysis. To meet this demand, module is available so users can set up required plant,
Bentley has developed a Dynamic Simulator package, gains, occupancy and temperature schedules. Typical
that enables simulation to be carried out using the same schedules for a large range of buildings are provided,
Multi-Zone Air Flow Simulation
project data engineers have set up to use with simple load compatible with U.K. Part L requirements.
calculations. This means simulation studies can be carried
out without re-entering project data. A plant simulation module enables engineers to simply
define HVAC systems such as radiators, warm air, constant
Extensive Roof and Floor Modeling Program Available volume a/c, VAV, fan coils, room a/c units, etc. Central plant
With Hevacomp software, a building is set up by tracing items such as boilers, chillers and cooling towers can also
the internal perimeter of each room, and adjacent surfaces be defined. Databases of common plant and equipment are
are automatically detected as partitions. Databases of provided. From a brief HVAC set of data, the package will
constructional elements are used. An extensive roof and automatically set up all the required HVAC components,
floor modeling program enables simple or complex roofs water and air networks and central plant. Although simple
to be traced from DXF files. Walls and partitions are to set up, complex systems can be defined, which are not
automatically trimmed vertically to fit the roof, and rooms limited to Compact HVAC components.
Weather Data
above and below target rooms are detected. This enables Moreover, plant sizing can be carried out, using summer and
a full 3D model to be produced for little more effort than winter design days, producing plant and equipment sizing
required for a simple 2D tracing. schedules. In addition, annual energy consumption can be
Once the building has been set up, building simulation, computed, together with fuel cost and CO2 consumption.
linking to EnergyPlus, can be performed to examine room Bentley has an alliance with CHAM (U.K.) so that results from
heat losses and gains, summer overheating, peak design Dynamic Simulator can automatically be used to carry out
months, overheating frequency, and building energy. The CFD analysis, enabling room air movement and temperature
package will also produce 3D external shading graphics studies. Hevacomp software provides an extensive object
and internal solar penetration graphics, showing moving library so that users can place items such as furniture and
sunshine patches within rooms. people in rooms to see the effect on air movement.
Design Simulation Results Viewer
SYSTEM REQUIREMENTS Bentley Hevacomp Simulator V8i At-A-Glance
Processor: Dynamic Simulation Predefined HVAC Systems Renewable and
P4 @3+GHz
with EnergyPlus • Predefined standard HVAC Low Energy Systems
Memory: • Easy interface to powerful systems are included • Define renewable systems
2 GB engine as well as an emerging • Significant time is saved such as wind and solar
Graphics: industry standard using predefined systems for • Design low carbon buildings
AGP/PCIe with 256m • Detailed analysis of complex standard designs
buildings and systems Biomass Systems
Operating System: User Defined HVAC Systems • Biomass boilers can be setup
Win 2000 or XP pro • Confidence in engine with
significance support and backup • User defined HVAC systems • Design low energy designs
USB: from a simple interface with
Yes Extensive Weather Databases a graphical mimic Passive Design
CD-ROM: • Over 2900 locations worldwide • Full flexibility to defined actual • Full control over windows,
Yes • Confidence that project location systems for shaded designs natural and mechanical
data is available ventilation strategies
Plant and Building Simulation • Detailed analysis of low
Localized Weather Databases is Fully Coupled energy and passive designs
• Local databases available • Room demand is affected by HVAC
Find out about Bentley equipment within the space
• Locally sourced databases are
at: www.bentley.com included where required • Fully coupled simulation allows
Contact Bentley plant energy calculations to be
1-800-BENTLEY (1-800-236-8539)
Overheating Calculations executed in coordination, rather
Outside the US +1 610-458-5000 • Assess low energy designs and than two separate calculations
comfort conditions • More accurate plant
Global Office Listings
• More accuracy from analysis of low energy analysis
www.bentley.com/contact
energy designs
Built-in Part Load Curves
Overheating Frequency • Part load efficiency curves
• Annual summer temperature for all plant items
calculations can identify • More accurate results as
overheating risk plant efficiencies will vary
• Minimize overheat days per year throughout the year

Shadow Analysis Airflow Analysis Using CFD