PROJECT: NLEX – MAPULANG LUPA TRICYCLE/PEDESTRIAN OVERPASS B.

B. ALL REINFORCING STEEL SHALL BE FREE FROM RUST, PAINT, OIL OR ANY OTHER DELETERIOUS MATERIAL
THAT WILL TEND TO WEAKEN BOND WITH CONCRETE
LOCATION: VALENZUELA CITY
3. STRUCTURAL STEEL

A. DESIGNED LOADS FOR BRIDGE SHALL MEET THE REQUIRED STRUCTURAL DESIGN CRITERIA.
DESIGN CRITERIA: B. ALL STRUCTURAL WORKS SHALL BE IN ACCORDANCE WITH AISC SPECIFICATION FOR DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDING.

A. SPECIFICATIONS C. STEEL PLATES, SHAPES, BARS AND METAL FABRICATIONS: ASTM A-36
1. NSCP - NATIONAL STRUCTURAL CODE OF THE PHILIPPINES VOL. 1, 7TH EDITION, 2015
2. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION 14TH EDITION, 2011 D. STRUCTURAL BOLTS AND NUTS SHALL BE ASTM A-325 HOT DIP GALVANIZED
3. ASTM - APPLICABLE STANDARDS OF AMERICAN SOCIETY FOR TESTING AND MATERIALS
4. AASHTO LRFD - LRFD GUIDE SPECIFICATION FOR THE DESIGN OF PEDESTRIAN BRIDGES,2009 E. STRUCTURAL ANCHORAGE BOLTS SHALL CONFORMT TO ASTM A307
5. BSDS-DPWH - LRFD BRIDGE SEISMIC DESIGN SPECIFICATIONS 1ST EDITION, 2013
6. DPWH-DGCS – DPWH DESIGN GUIDELINES & CRITERIA & STANDARDS, VOL. 5, 2015 EDITION F. ELECTRODE FOR WELDING: ASTM A233 E_70XX SERIES; COMPLY WITH AWD D1.1 CODE REQUIREMENTS.

B. DESIGN LOADS G. ALL BUTT WELDS SHALL BE FULL PENETRATION WELDS AND SHALL BE PROPERLY BACK-CHIPPED OR GOUGED,
1. DEAD LOAD BACK UP PLATES SHALL BE PROVIDED AS REQUIRED.
CONCRETE - 24.00 KN/CU.M.
STEEL - 77.00 KN/CU.M. H. ALL WELDS NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS, USING NOT LESS THAN THE MINIMUM SIZE
BASE ON THINNER PART OF JOINED PER AISC / AWS.
2. LIVE LOAD
PEDESTRIAN - 4.80 KPA I. USE NON - SHRINK GROUT BETWEEN COLUMN BASEPLATE AND CONCRETE PEDESTAL WITH COMPRESSIVE
STRENGTH OF 65 N/MM² AFTER 28 DAYS.
3. WIND LOAD (CALCULATED AS PER NSCP 2015
STRUCTURE TYPE - OPEN
J. STRUCTURAL STEEL SHALL BE APPLIED BY THE FOLLOWING COATING SYSTEM:
EXPOSURE CATEGORY - C
SURFACE PREPARATION :SSPC-SP10 NEAR WHITE BLAST CLEAN
BUILDING CLASSIFICATION CATEGORY IV
PRIMER :INORGANIC ZINC RICH PRIMER APPLIED WITHIN 4 HOURS OF BLASTING, MINIMUM
BASIC WIND SPEED - 250 KPH
BUILD THICKNESS 75 MICRONS
TIE COATS :EPOXY POLYAMINE 125 MICRONS
4. EARTHQUAKE LOAD
TOP COAT :POLYURETHANE FINISH TWO COATS EACH 75 MICRONS
CALCULATED AS PER DPWH BSDS SPECIFICATION
TOTAL FILM BUILD :350 MICRONS
OPERATIONAL CLASSIFICATION = II (ESSENTIAL BRIDGES)
ACCELERATION COEFFICIENT, PGA = 0.6
4. FOUNDATION
SPECTRA RESPONSE, SS = 1.30
SPECTRA RESPONSE, S1 = 0.50
A. FOUNDATION SHALL REST AT THE TOP OF ROCK LAYER, NO PART OF THE FOUNDATION SHALL REST ON FILL.
GROUND TYPE = I (HARD)
B. EXCAVATION FOR STRUCTURES SHALL BE NEAT LINES AS SHOWN ON THE PLANS AND THE GROUND
UNDERNEATH THE STRUCTURE FOUNDATION SHALL NOT BE DISTURBED. LEAN CONCRETE IS NECESSARY
CONSTRUCTION NOTES: BEFORE POSITIONING OF THE STEEL REINFORCEMENT.

D. WORKS
A. GENERAL
1. CONSTRUCTION NOTES AND TYPICAL DETAILS TO APPLY DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. MODIFY
1. REINFORCING STEEL BARS
TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
A. FABRICATION
B. DIMENSIONS, ELEVATIONS AND STATIONINGS
1. ALL DIMENSIONS ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED ON THE PLANS
REINFORCING BARS SHALL BE ACCURATELY FORMED TO THE SHAPES AND DIMENSIONS INDICATED ON THE
2. ALL ELEVATIONS ARE IN METERS AND BASED ON MEAN SEA LEVEL ELEVATION 0.00.
PLANS AND SHALL BE FABRICATED IN A MANNER THAT WILL NOT INJURE THE MATERIAL.
3. ALL STATIONINGS ARE IN KILOMETERS + METERS
4. UNLESS OTHERWISE SHOWN ON THE PLANS, ALL EXPOSED EDGES SHALL BE CHAMFERED 2CM.
B. BAR BENDING, SPLICING AND PLACING
5. ALL ELEVATIONS, STATIONINGS, AND DIMENSIONS SHALL BE VERIFIED PRIOR TO ACTUAL CONSTRUCTION
UNLESS OTHERWISE PERMITTED, ALL REINFORCING BARS REQUIRING BENDING SHALL BE BENT COLD. BAR
C. MATERIALS
BENDING LIST SHALL BE PREPARED BY THE CONTRACTOR SUBJECT TO THE APPROVAL OF THE ENGINEER.
1. CONCRETE – UNLESS SPECIFICALLY INDICATED ON THE PLANS, THE MINIMUM CYLINDER STRENGTH OF CONCRETE AT 28
WELDED SPLICES SHALL DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF BAR. IF
DAYS SHALL BE AS FOLLOWS:
PERMITTED, NOT MORE THAN 50% OF THE BARS SHALL BE SPLICED AT ANY ONE SECTION.
DESCRIPTION CLASS F’C MPA (PSI) MAXIMUM SIZE OF CONCRETE MINIMUM CONCRETE C. SPACER DIAMETER AND SPACING
AGGREGATES (MM) COVER (MM)
SLAB AA 21 (3000) 19MM 19MM MINIMUM BAR DIAMETER OF SPACER TO USE IN MULTIPLE LAYER REINFORCEMENT SHALL BE EQUAL TO THE BAR
DIAMETER OF THE REINFORCEMENT BUT NO LESS THAN 30MM. MINIMUM SPACING OF BAR SHALL BE 40MM.
COLUMN AA 28 (4000) 19MM 50MM
2. CONCRETE MIXES AND PLACING
FOUNDATION AA 28 (4000) 19MM 75MM
A. DESIGN OF CONCRETE STRENGTH SHALL BE AS SET FORTH UNDER ITEM 1 OF MATERIALS.
LEAN CONCRETE A 17 (2430) 19MM
B. CONCRETE SHALL BE DEPOSITED, VIBRATED AND CURED IN ACCORDANCE WITH THE SPECIFICATIONS.
2. REINFORCING STEEL C. FOR CONCRETE DEPOSITED AGAINST THE GROUND, LEAN CONCRETE WITH A MINIMUM THICKNESS OF 75MM
SHALL BE LAID FIRST BEFORE PLACING THE REINFORCEMENT. THIS LEAN CONCRETE SHALL NOT BE
A. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 40 ON Ø 12 AND SMALLER BARS AND GRADE CONSIDERED IN MEASURING THE STRUCTURAL DEPTH OF THE SECTION.
60 FOR Ø16MM AND LARGER BARS.