AV.
DE
F
LOS
LP A B C D E
GO
A B C
BER
D
E
NAD
15.88 F 34.00
G
OR
2.19 5.00
ES
LP 8.60 9.40 8.50 8.50 8.50 8.50
3.20
3.20 34.80
0.15
1 3.00
MURO PARA MEDIDORES
1.40
N
AUTOSOPORTADO
ACOMETIDA
DESCONECTADOR
ACOPLAMIENTO
COMBINADO
TRANSFORMADOR
QD LOGIC
TABLERO
S.S
THRIAL 1600 KVA +2.63
1´ NPT +0.60
A
TRANSFORMADOR
ERO
TRANSFORMADOR
SECO
3.50
+2.64
hp
PACKARD
HEWLETT
+3.00
B
IGU
(ESQUEMÁTICO)
CONGELADOR
CUARTO
(ESQUEMÁTICO)
F
FFO
ELECTRICO
RPBI +2.20
RU
2.10
CUARTO
2.10
ESME
VIGILANCIA ELECTRICO PLANTA EMERGENCIA LOCKERS CARCAMO
HOMBRES
NPT +0.60 OFICINA DE CONTENEDOR DE
RALD
CASA
NPT +4.00 TRANSFER. TRANSFER. TRANSFER. MANTO. BASURA
C. RETARDO AUTOMAT. AUTOMAT. +2.08
B.A.P. +1.86
2 REG ELEC.
GASOLINERA
TSV0
TN0
EQUIPOS
TE0
S. DE VIDA C.CRITICOS
POSTE TEL +0.09
A
S
B.A.P. B.A.P
B.N. ±0.00 3.00 SEPTICO AREA PERMEABLE
ACCESO PEATONAL
. muro bajo H= 1.10 m
1.45
1.10
1.39
0.90
corre +2.20
ALTURA0.50 m 1.10
1.10
FRACC.
PASO PEATONAL
REFORMA
MOJON
1.10 B.A.P. +2.50
B.A.P.
+2.77 +3.03 proyeccion losa B.A.N.
PASO PEATONAL
1 1
SALIDA VEHICULAR
2.79
+3.00 +3.00 +3.00 +3.00 SIMBOLOGIA:
C C
+3.00
CORTE EN PLANTAS
proy. trabe
ELEVADOR
proy. losa
I
proy. trabe
R
CAPACIDAD
ICULA
16 15
1000 KG
CASETA DE
VEH
VIGILANCIA 0.00 ANCHO TERMINADO DE VANO (VENTANAS / PUERTAS) (EN MTS.)
ESO
14 13 12
proy. ducto
1.20 x 0.70 m
1.25
ACC
11 10 9
0.86
Sube Pendiente 0.00 ANCHO TERMINADO DE PASILLO O LOCAL (EN MTS.)
1.08
8 7 6
+0.60
B.A.P.
2.10
1.69 CAMBIO DE NIVEL (ESCALÓN)
ENTRADA VEHICULAR
proy. losa
8.50
2.89
proy. trabe
proy. trabe
5
POSTE CFE
A
RO
+2.20 N.P.T. + 0.00 NIVEL DE PISO TERMINADO N.L.B.P.F. NIVEL DE LECHO BAJO DE
UNIDAD HAB
UE
4.34
ITACIONAL + 0.00 PLAFÓN FALSO
UNIVERSITA +3.00 +3.00
F
+3.00 +3.00 +3.00
FIG
4
RIA N.PV.T. + 0.00 NIVEL DE PAVIMENTO TERMINADO
2.20
2 2 B.A.P. BAJADA DE AGUA PLUVIAL
FO
+3.25
14
18
17
16
15
13
19
MOJON
20
N.A.T. + 0.00 NIVEL DE AZOTEA TERMINADA
UF
3.91 2.65 1.95 2.66 3.90 2.71 B.A.N. BAJADA DE AGUAS NEGRAS
A B
.R
12
+3.00
D D
21
B.A.P.
1.10 2.14 2.14 1.85 1.15 N.PR.T. + 0.00 NIVEL DE PRETIL TERMINADO T.V.
Su
B.A.N.
TUBO DE VENTILACIÓN
AV
11
be
muro bajo H =1.10 m
BAJA
BASURA TEMPORAL MORTUORIO 10
Ra
+3.25
m
9
SS SS
pa
1.90
1.36
VACIO 8
COMEDOR 3
+3.25
EMPLEADOS 7
SUBE
+3.25 NOTAS GENERALES:
1.25
0.90
0.90
25.50
6
ATN DEUDOS
8.50
5
1
4
3.
LOCKERS LOCKERS
1.80
+3.25
52
HOMBRES +3.25 MUJERES +3.25
0.90
+3.25
0.90
+3.25
+3.25 SITE
CTO.
ELECT 2
0.90
+3.02
UN
ID
2.07
VIDEO
AD
VIGILANCIA
+3.25
0.93
3.33
HA
0.93 ELEVADOR
2.10
INTENDENCIA
+3.23
BI
CAMILLERO
12
ASEO
TA
+3.25 +3.00 +3.00
.0
Pend. 13%
1.17
CI
2
3 3
8.
NA
50
B.A.N.
B.A.P. proy. ducto
proyeccion de losa
1.20 x 1.70 m
ALMACEN DE
UN
1.49
+3.46 B.A.P.
B.A.N.
MEDICAMENTOS +3.25
IV
2.00
ER
1.43
I +3.25
SI
corre 3.00 corre
TA
GASES
Fachada Este
MEDICINALES
RI
EQUIPO
+3.67 +3.25
A
HIDRONEUMATICO
VALVULA
BODEGA DE SUAVIZADOR
COMPUERTA 3"Ø TABLERO
ARCHIVO MUERTO
VALVULA
TABLERO
3. 2
MARIPOSA 3"
8.50
07
3.
BOMBA DE VACIO
MARCADOR
FILTRO TURBIDEZ DE FLUJO 3"
+3.25
5
VALVULA
BOLA 1 1/4"Ø
CIRCULADORAS
[ 3 ]BOMBAS
RETORNO 1 1/4"
CLORADOR
BOMBA JOCKEY
CLORADOR
CUADRO DE AREAS
SILENCIADOR
LINEA DE
PRUEBA 1 1/4"Ø
MOTOR DIESEL
2.
59
COMPRESOR DE AIRE
VALVULA CHECK 1 1/4"
VALVULA
DE ALIVIO 3/4"
TANQUE
+4.11
PRECARGADO
TANQUE DIESEL
EDIFICIO:718.10 M2 CONST.
12
TABLERO JOCKEY TABLERO ELECTRICO TABLERO DIESEL
V. FLOTADOR
.0
2
ACCESO Y CTOS DE MAQS: 155.20 M2 CONST.
proy. ducto
proy. ducto
4 4
8.
50
+4.34
5.
B.A.N.
46
B.A.P.
B
+4.84
+4.93
+5.02
UNID
AD H
ABIT
ACIO
A B NAL
UNIV C D E
ERS NOMBRE DEL PROYECTO:
ITAR
IA
ESCRITURA PÚBLICA:
NÚMERO OFICIAL:
USO DE SUELO:
PROPIETARIO:
UNID DIBUJO:
AD H
ABIT ING. JOSE MIGUEL CRUZ MARTINEZ
ACIO
NAL
UNIV
ERS
ITAR
IA DRO:
PLANO:
ARQUITECTONICOS
PLANTA NIVEL
ARQ-1
SEMISOTANO
ESCALA: ACOTACIÓN: FECHA: