Anda di halaman 1dari 6

Datasheet 325-7

12/16/2011

Eclipse Single-Ended
Ceramic Radiant Tube Burners
Model SER 450
Version 5
Typical Burner Input 1000’s Btu/h (kW)
Parameter 50 (14.6) 75 (21.9) 100 (29.3)
Low firing rate, 1000’s Btu/h (kW)1
10 (3.0) 10 (3.0) 10 (3.0)
Between 150 - 220% excess air
Total static air pressure required, "w.c. (mbar)2
9.7 (24.2) 15.6 (39.0) 18.5 (46.3)
(509mm recuperator length)
Air flow, SCFH (Nm3/hr)
560 (15.0) 840 (22.5) 1120 (30.0)
At 15% excess air
Gas Inlet Pressure Required, "w.c. (mbar)3
7.8 (19.4) 13.0 (32.4) 14.0 (34.9)
Tap B (see page 4)
Maximum Furnace Temperature
2000°F (1090°C)
Refer to page 3 for maximum heat flux
Piping NPT or BSP interface is available.
Flame Detection UV Scanner
Ignition Direct Spark Ignition (6 kVAC)
Fuels
Natural Gas
For any other mixed gas contact Eclipse
Weight, lbs (kg)4
36 (16.5)
Burner Length “M” (less mounting extension, inner and outer tubes)
Approvals

1 The
low fire rate represents the capability of the burner. Achievement of this rate will be affected by the control method
and ratio regulator used in the system design. Typical ratio regulators provide a 10 to 1 turndown from high to low fire.
2 Air supply pressure required at the burner inlet is static pressure at Tap C plus the pressure drop across Tap A to

Tap C. See graphs on page 2.


3 If a ratio regulator is being used, the gas pressure into the ratio regulator should be at least 5" w.c. above the static air

pressure at Tap A.
4 All weights are approximate.

• All information is based on laboratory testing with neutral (0.0" w.c.) exhaust conditions.
• All inputs based upon gross calorific values and standard conditions: 1 atmosphere, 70°F (21°C).
• Air and fuel pressure data given in this document are based on 15% excess air and hot furnace conditions.
• Plumbing of gas will affect accuracy of orifice readings. All information based on general acceptable air and gas piping
practices.
• Eclipse reserves the right to change the construction and/or configuration of our products at any time without being
obliged to adjust earlier supplies accordingly.
Performance Graphs

Ignition Envelope Static Air Pressure at Tap C


16 70 28

Static Pressure (mbar) ± 10%

Static Pressure "w.c. ± 10%


14 60 24

12 20
50
10
40 16
%O2

8
30 12
6
20 8
4
10 4
2
0 0 0
0 25 50 75 100 125 150 10 30 50 70 90 110 130 150
Input, HHV (x 1000 Btu/h) Input, HHV (x 1000 Btu/h)
0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40
Input, LHV (kW) Input, LHV (kW)

Burner Input vs. ∆P Air @ 3% O2 Burner Input vs. ∆P Natural Gas


(Measured from Tap “A” to Tap “C”) (Measured from Tap “B” to Tap “D”)
15 10 17.5 7
9
Pressure Drop "w.c. ± 10%

Pressure Drop mbar ± 10%

6
Pressure Drop mbar ± 10%

Pressure Drop "w.c. ± 10%

15.0
fice

20 8
ice
fice

e
ific
ori
orif

7 12.5 5
ori

or
mm

m
mm
mm
fice

15 6 10.0 4
4.6

8
3.8
17

ice
5.
ori

5 if
or
mm

m 7.5 3
10 4 m
22
15

3 5.0 2
5 2
2.5 1
1
0 0 0.0 0
0 25 50 75 100 125 150 0 25 50 75 100 125 150
Input, HHV (x 1000 Btu/h) Input, HHV (x 1000 Btu/h)
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
Input, LHV (kW) Input, LHV (kW)

2 Eclipse Ceramic SER Burner, Model SER450 V5, Datasheet 325-7, 12/16/2011
Efficiency Graphs

“M” Length Burner (509 mm)


87 78 558 292

84 76 640 337
82 74 1600°F 718 381
% Efficiency Based on LHV

% Efficiency Based on HHV

Flue Gas Temperature °C


Flue Gas Temperature °F
(871°C)
80 72 795 423
78 70 875 468
1900°F
76 68 (1038°C) 952 511

74 66 1030 554

72 2300°F
64 1105 596
(1260°C)
70 62 1180 668
68 60 1255 679
66 58
20 30 40 50 60 70 80 90 100 110 120 130 140
Input, HHV (x 1000 Btu/h)

5 10 15 20 25 30 35 37
Input, LHV (kW)

60
Recommended Heat Flux
130
External Tube Surface kW per m2
Maximum Heat Transfer Rate of

120

50 110

100
Btu/h per in2

40 90

80

70
30

60

50
1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
Furnace Temperature °F

800 850 900 950 1000 1050 1100 1150 1200 1250 1316
Furnace Temperature °C

Eclipse Ceramic SER Burner, Model SER450 V5, Datasheet 325-7, 12/16/2011 3
Horizontally Mounted Burner
Dimensions & Specifications
Dimensions in mm (inches)

Ø101.6
(4.0)

Exhaust Tap Tap A

Tap C 4X Ø15
(0.6)
208
(8.2)
Peepsight
104.5
(4.1)
Ø175
148 (6.9)
(5.8)
67
(2.6)

Sparkrod UV Scanner
Adapter or
Pipe Plug
Section A-A
238
(9.4)

229
(9.0)
109 16.5
Exhaust (4.3) (0.7)
Outlet 19.5
3” NPT (0.8)

Mounting Extension Length


50-250mm (2.0-9.8)
Air Inlet IN 50mm (2.0) Increments
1” NPT/Rc 1.0
A
47 8.5
(1.9) (0.3)

Tap Effective Length


D 800-1400mm (31.5-55.1)
Gas Inlet in 50mm (2.0) increments
Tap 1/2” NPT/Rc 0.5 1500-1900mm (59.1-74.8)
B 311.1 A in 100mm (3.9) increments
(12.3)
572.3
(22.5) Burner Length “M” = 509mm (20.0)

4 Eclipse Ceramic SER Burner, Model SER450 V5, Datasheet 325-7, 12/16/2011
Vertically Mounted Burner
Dimensions & Specifications
Dimensions in mm (inches)

Ø101.6
(4.0)

Exhaust Tap
Section B-B

208 Tap A
(8.2) Tap C
104.5 Ø173.3
(4.1) Peepsight (6.8)

148
(5.8)
67
(2.6)

Spark rod 4X Ø15


(0.6)
UV Scanner
Adapter or 198
Pipe Plug (7.8) 331.2
(13.0)

Vertically Mounted
Outer Tube Option 3-8 NPT

134.4
229 (5.3)
(9.0)

109
Exhaust (4.3)
Outlet 22.5
3” NPT (0.9)

Mounting Extension Length


50-250mm (2.0-9.8)
Air Inlet IN 50mm (2.0) Increments
1” NPT/Rc 1 8.5
(0.3)
B 47.1
(1.9)

Ø115.9
(4.6)
Tap
D

Tap
B Gas Inlet
1/2” NPT/Rc 0.5
311.6 B
(12.3)
420.4
(16.6) Burner Length “M” = 509mm (20.0) Effective Length
800-1400mm (31.5-55.1)
in 50mm (2.0) increments
1500-1900mm (59.1-74.8)
in 100mm (3.9) increments

Eclipse Ceramic SER Burner, Model SER450 V5, Datasheet 325-7, 12/16/2011 5