Anda di halaman 1dari 11

ENG

Service
manual

ACP-09PT25HC
ACP-09PT22HC
RoHS
Explosive view of Vivax portable type models

ON/OFF

FAN SPEE MODE
D

TIMER SWING
HOLD

HOUR MIN

figure 7-2
Spare partslist of ACP-09PT25HC ACP-09PT22HC model
Table
N Part No Qt
Description
o ACP-09PT25HC ACP-09PT22HC y
1 top panel 100180206 1
2 electric installation board 109990018 1
3 up volute I 109990009 1
4 up centrifugal fan 100020001 1
5 up volute II 109990010 1
6 motor 030020334 1
7 down volute cover plate 109990008 1
8 down centrifugal fan 100020006 1
9 down volute 109990007 1
10 down volute fixed plate 029992901 1
11 forecooling drip pan assembly 990168801 1
12 partition plate 020030011 1
100440119 安装附板 1
+100440120 安装附板 2
fixing assembly
13 +109990046 排风软管接头 B 1
+109990020 排风扁嘴
+109990091 排风软管
14 water tank base 109990014 1
972600009 美芝
15 compressor 1
990011583 松下
16 support 029993022 4
17 exhaustion board 109990019 1
18 exhaustion hose joint 109990045 1
19 water tank 990160096 1
20 right panel 109990004 1
21 base 020010307 1
22 universal wheel 100350001 4
23 condenser assembly 990040411 1
24 water level switch assembly 990160094 1
25 left panel 109990003 1
26 face plate 395142006 1
27 exhaustion board assembly 990160095 1
28 filtering net assembly 100190701 1
29 PTC heater — 1
30 heater support — 1
31 evaporator assembly 990112203 2
32 remote controller 336821007 1
The data are subject to change without notice.
Function
1.Cooling

● The indoor temperature is detected by room temperature sensor of unit and the temperature controlled
by the cyclic switch of compressor under the control of the electric control board.

● blower fan is running at set speed, when the compressor is stopped by the room temperature. blower fan
continuous running two minutes after stop.

● Start up the compressor: when the room temperature is more than Ts+1℃(Ts℃ is the set temperature),
compressor → start-up

● Shut down the compressor: when the room temperature is less than the set temperature Ts℃
compressor → shutdown

a. Working curve for temperature control

¡ ã
C

¡ ã
C

2.Anti freeze protection function of evaporator (cooling)

● This function is to prevent freezing on the surface of evaporator.

● When the temperature of coil pipe of the units is less than or equal to 1℃ and the compressor has
continuous run for more than ten minutes, the compressor shut down through the electric control board
and the blower fan is running at low speed wind.

● When the temperature of coil pipe of the units is more than or equal to 7℃ and the compressor has
shutdown for more than three minutes, the compressor blower fan start to run in the set mode.
¡ ã
C

¡ ã
C

7¡ ã
C
1¡ ã
C

3.Heating

● The indoor temperature is detected by room temperature sensor of units and the temperature controlled
by the electric heating under the control of the electric control board.

● In heating mode, conditioner is heat by electric heating, compressor is forbidden to work, there have two
electric heating, Working curve for temperature control follow.

OFF

Start-up one

ON Tr(℃)

Ts -1 Ts Ts+1

● In heating mode, electric heating and blower fan work synchronously, blower fan work at set wind speed.
the blower fan shall be on for twenty seconds after the electric heating is closed.

4.Overheat protection

When the temperature of electric heating rises to 152℃, electric control board shutdown electric heating, the
blower fan shall be on for twenty seconds after the electric heating is closed. System display E8 error.
5.Dehumidification

Dehumidification running is to eliminate the water vapor in the air by using the cool circulating capacity, but
the dehumidification will not decrease the indoor temperature in great deal. The air conditioner automatically
repeats on and off circulation according the room temperature and set temperature, which is shown in the
following figure.

Room temperature

Tr
When Tr more than or equal to Ts and 20 degree, lower fan of compressor: Intermittent running (run 6
minutes and stop 4 minutes

Ts
20℃
portable air conditioner forbidden dehumidifier

Note

● In the dehumidification mode, electric heating forbidden work. System haven’t anti freeze protection
function and abnormal protection function.

6.Ventilation working mode

In the ventilation mode, the compressor and electric heating are all closed and the blower fan is running at the set
speed.

7.Automatic mode

● Conditions for entering the automatic running mode are:

1. After power-up for the first time start up and select the automatic operating mode, the working mode had
set ,it doesn’t change with Tr.

Room temperature Ts>26 26≤TR≤21 TR<21


State cooling Dehumidification Heating

Note: ① the set temperature will store to the default 25 ℃.

② When it is the single cold type air conditioner, the air conditioner will select the ventilation mode and run
when receiving heating signal.

8.Time start-up and shutdown function

When the time start-up and shutdown are used, the clock of remote controller shall be corresponding to the
current clock and the timing times is less than or equal to 12 hours; if the time start-up or time shutdown
times is get to, it will start-up or shutdown immediately.
9.self-check function

When pressing down the power key, then power up and enter the self-check program; system check all
output device.

10.Abnormality of unit

After the compressor runs five minutes in cooling mode, if the temperature of coil pips is more than 25℃ in
the continuous 40 minutes. The controller will automatically shutdown and display error code E4.

11. water tank alarm function


when water lever is over limit in water tank, water lever alarm lamp flash, conditioner enter ventilation mode.